Shopping Cart

No products in the cart.

2007 ASHRAE Handbook HVAC Applications Chapter26

$25.35

HVAC Applications Handbook – Chapter 26. Nuclear Facilities

Published By Publication Date Number of Pages
ASHRAE 2007 11
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 Basic Technology
Basic Technology
As Low as Reasonably Achievable (ALARA)
As Low as Reasonably Achievable (ALARA)
Design
Design
Normal or Power Design Basis
Normal or Power Design Basis
Safety Design Basis
Safety Design Basis
2 Outdoor Conditions
Outdoor Conditions
Indoor Conditions
Indoor Conditions
Indoor Pressures
Indoor Pressures
Airborne Radioactivity
Airborne Radioactivity
Tornado/Missile Protection
Tornado/Missile Protection
Fire Protection
Fire Protection
3 Smoke Management
Smoke Management
Control Room Habitability Zone
Control Room Habitability Zone
Air Filtration
Air Filtration
Department of Energy Facilities
Department of Energy Facilities
4 Confinement Systems
Confinement Systems
Zoning
Zoning
Air Locks
Air Locks
Zone Pressure Control
Zone Pressure Control
Cascade Ventilation
Cascade Ventilation
Differential Pressures
Differential Pressures
Ventilation
Ventilation
5 Ventilation Requirements
Ventilation Requirements
Ventilation Systems
Ventilation Systems
Control Systems
Control Systems
Air and Gaseous Effluents Containing Radioactivity
Air and Gaseous Effluents Containing Radioactivity
Commercial Facilities
Commercial Facilities
Nuclear Power Plants
Nuclear Power Plants
6 Accident Scenarios
Accident Scenarios
Major NSSS Types
Major NSSS Types
Russian Reactor Types
Russian Reactor Types
Commercial Plant License Renewal and Power Uprate
Commercial Plant License Renewal and Power Uprate
Advanced Reactor Systems: New Power Generation Plants
Advanced Reactor Systems: New Power Generation Plants
7 Plant HVAC&R Systems
Plant HVAC&R Systems
Pressurized Water Reactors
Pressurized Water Reactors
Reactor Containment Building
Reactor Containment Building
Boiling Water Reactors
Boiling Water Reactors
Primary Containment
Primary Containment
Reactor Building
Reactor Building
8 Turbine Building
Turbine Building
Heavy Water Reactors
Heavy Water Reactors
Containment Inlet Air-Conditioning/Exhaust Ventilation System
Containment Inlet Air-Conditioning/Exhaust Ventilation System
Areas Outside Primary Containment
Areas Outside Primary Containment
Auxiliary Building
Auxiliary Building
Control Room
Control Room
9 Control Cable Spreading Rooms
Control Cable Spreading Rooms
Diesel Generator Building
Diesel Generator Building
Emergency Electrical Switchgear Rooms
Emergency Electrical Switchgear Rooms
Battery Rooms
Battery Rooms
Fuel-Handling Building
Fuel-Handling Building
Personnel Facilities
Personnel Facilities
Pumphouses
Pumphouses
Radioactive Waste Building
Radioactive Waste Building
Technical Support Center
Technical Support Center
Gas-Cooled Reactor HVAC Systems
Gas-Cooled Reactor HVAC Systems
Nonpower Medical and Research Reactors
Nonpower Medical and Research Reactors
Laboratories
Laboratories
Glove Boxes
Glove Boxes
10 Laboratory Fume Hoods
Laboratory Fume Hoods
Radiobenches
Radiobenches
Decommissioning of Nuclear Facilities
Decommissioning of Nuclear Facilities
Low-Level Radioactive Waste
Low-Level Radioactive Waste
Waste Handling Facilities
Waste Handling Facilities
Reprocessing Plants
Reprocessing Plants
Codes and Standards
Codes and Standards
2007 ASHRAE Handbook HVAC Applications Chapter26
$25.35