ASTM-D3590 N/A

$40.63

D3590-11 Standard Test Methods for Total Kjeldahl Nitrogen in Water

Published By Publication Date Number of Pages
ASTM N/A 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM D3590-11-Reapproved

Historical Standard: Standard Test Methods for Total Kjeldahl Nitrogen in Water

ASTM D3590

Scope

1.1 These test methods cover the determination of total Kjeldahl nitrogen. The following test methods are included:

1.2 The analyst should be aware that precision and bias statements included may not necessarily apply to the water being tested.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

8.1 This test method covers the determination of total Kjeldahl nitrogen in water. It measures free ammonia or ammonia formed from the conversion of nitrogen components of biological origin such as amino acids and proteins. However, the procedure may not convert the nitrogenous compounds of some wastes to ammonia. Examples of such compounds that may not be measured are nitro compounds, hydrozones, oximes, nitrates, semicarbazones, pyridines, and some refractory tertiary amines.

8.2 Three alternatives are described for the final determination of the ammonia: a titrimetric method, which is applicable to concentrations above 1 mg N/L; a Nesslerization method, which is applicable to concentrations below 1 mg N/L; and a potentiometric method which is applicable to the range from 0.04 to 1000 mg N/L.

8.3 This test method is described for micro and macro systems. Micro determination can be made on sample aliquots containing up to 10 mg of nitrogen.

15.1 This test method covers the automated determination of total Kjeldahl nitrogen in water and wastewater and is based on the same principle and subject to the same limitations as the manual method (see 8.1).

15.2 This test method is a semiautomated procedure applicable to drinking water, surface water, and domestic and industrial wastes containing from 0.3 to 5 mg/L of nitrogen.