Shopping Cart

No products in the cart.

BS EN ISO 10548:2003:2009 Edition

$102.76

Carbon fibre. Determination of size content

Published By Publication Date Number of Pages
BSI 2009 18
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
5 TitlePage – Carbon fibre�— Determination of size content
7 TableofContent – Contents Page
8 Foreword – Foreword
9 Scope – 1��� Scope
NormativeReference – 2��� Normative reference
Clause1 – 4��� Principle
10 Clause1 – 5��� Test specimens
Clause1 – 6��� Conditioning
Clause1 – 7��� Test methods
Subclause2 – 7.1��� Method�A: Solvent extraction
Subclause3 – 7.1.1��� Apparatus and materials
UntitledSubclause4 – 7.1.1.1��� Balance
UntitledSubclause4 – 7.1.1.2��� Hot-air oven
UntitledSubclause4 – 7.1.1.3��� Desiccator
UntitledSubclause4 – 7.1.1.4��� Soxhlet extractor
UntitledSubclause4 – 7.1.1.5��� Soxhlet extraction thimbles
UntitledSubclause4 – 7.1.1.6��� Rubber gloves
UntitledSubclause4 – 7.1.1.7��� Cutting blade
UntitledSubclause4 – 7.1.1.8��� Heating mantle
UntitledSubclause4 – 7.1.1.9��� Distilled water
11 Subclause3 – 7.1.2��� Procedure�1
UntitledSubclause4 – 7.1.2.1��� Dry an extraction thimble (
UntitledSubclause4 – 7.1.2.2��� Weigh the thimble to the nearest
UntitledSubclause4 – 7.1.2.3��� Place a test specimen in the thimble and weigh to the nearest
UntitledSubclause4 – 7.1.2.4��� Place the thimble and its contents in the siphon chamber of the S…
UntitledSubclause4 – 7.1.2.5��� Extract for
UntitledSubclause4 – 7.1.2.6��� Turn off the heating mantle. Wait
UntitledSubclause4 – 7.1.2.7��� Dry the thimble and contents for
UntitledSubclause4 – 7.1.2.8��� Repeat the drying and weighing procedure until the difference in …
Subclause3 – 7.1.3��� Procedure�2
UntitledSubclause4 – 7.1.3.1��� If the specimen is free of loose fibre and can be coiled into a f…
UntitledSubclause4 – 7.1.3.2��� Weigh the test specimen to the nearest
UntitledSubclause4 – 7.1.3.3��� Carry out the extraction as described in
UntitledSubclause4 – 7.1.3.4��� Dry the specimen for
UntitledSubclause4 – 7.1.3.5��� Repeat the drying and weighing procedure until the difference in …
Subclause3 – 7.1.4��� Expression of results
Subclause4 – 7.1.4.1��� Procedure�1
12 Subclause4 – 7.1.4.2��� Procedure�2
Subclause2 – 7.2��� Method�B: Digestion with sulfuric acid and hydrogen peroxide
Subclause3 – 7.2.1��� Apparatus and reagents
UntitledSubclause4 – 7.2.1.1��� Balance
UntitledSubclause4 – 7.2.1.2��� Hot-air oven
UntitledSubclause4 – 7.2.1.3��� Desiccator
UntitledSubclause4 – 7.2.1.4��� Fume cupboard
UntitledSubclause4 – 7.2.1.5��� Rubber gloves
UntitledSubclause4 – 7.2.1.6��� Sintered-glass filters
UntitledSubclause4 – 7.2.1.7��� Cutting blade
UntitledSubclause4 – 7.2.1.8��� Dry-block heater
UntitledSubclause4 – 7.2.1.9��� Concentrated sulfuric acid
UntitledSubclause4 – 7.2.1.10��� Hydrogen peroxide solution
UntitledSubclause4 – 7.2.1.11��� Sodium hydroxide solution
14 Subclause3 – 7.2.2��� Procedure
UntitledSubclause4 – 7.2.2.1��� Pre-heat the heating block (
UntitledSubclause4 – 7.2.2.2��� Fill each of the dropping funnels with approximately
UntitledSubclause4 – 7.2.2.3��� Weigh a test specimen of carbon fibre yarn to the nearest
UntitledSubclause4 – 7.2.2.4��� Place the exhaust hood (see
UntitledSubclause4 – 7.2.2.5��� Start the suction pump (see
UntitledSubclause4 – 7.2.2.6��� Slowly open the dropping funnels containing the hydrogen peroxide…
UntitledSubclause4 – 7.2.2.7��� Use the laboratory jack to raise the heating block round the dige…
UntitledSubclause4 – 7.2.2.8��� Allow the digestion tubes to remain in the heating block at
UntitledSubclause4 – 7.2.2.9��� Lower the heating block away from the digestion tubes. If a solut…
UntitledSubclause4 – 7.2.2.10��� Allow the digested specimens to cool to room temperature.
UntitledSubclause4 – 7.2.2.11��� Heat sintered-glass filters (
UntitledSubclause4 – 7.2.2.12��� Filter each solution slowly through a sintered-glass filter and …
UntitledSubclause4 – 7.2.2.13��� Dry the sintered-glass filters and specimens for
UntitledSubclause4 – 7.2.2.14��� Repeat the drying and weighing procedure until the difference in…
UntitledSubclause4 – 7.2.2.15��� A correction factor will be required if the digestion causes a s…
Subclause3 – 7.2.3��� Expression of results
15 Subclause2 – 7.3��� Method�C: Decomposition by pyrolysis
Subclause3 – 7.3.1��� Principle
Subclause3 – 7.3.2��� Apparatus
UntitledSubclause4 – 7.3.2.1��� Balance
UntitledSubclause4 – 7.3.2.2��� Electric furnace
UntitledSubclause4 – 7.3.2.3��� Nitrogen supply unit
UntitledSubclause4 – 7.3.2.4��� Specimen holder
Subclause3 – 7.3.3��� Procedure
UntitledSubclause4 – 7.3.3.1��� Heat the specimen holder (
UntitledSubclause4 – 7.3.3.2��� Weigh a test specimen to the nearest
UntitledSubclause4 – 7.3.3.3��� Adjust the flow of nitrogen to the furnace so that the furnace wi…
UntitledSubclause4 – 7.3.3.4��� Place the specimen in the weighed specimen holder and place in th…
UntitledSubclause4 – 7.3.3.5��� Decompose the size on the specimen for the specified time at the …
UntitledSubclause4 – 7.3.3.6��� Either switch off the furnace and allow the specimen to cool in t…
UntitledSubclause4 – 7.3.3.7��� Allow the specimen plus specimen holder to cool to room temperatu…
16 UntitledSubclause4 – 7.3.3.8��� A correction factor will be required if the temperature and time …
UntitledSubclause4 – 7.3.3.9��� If the nature of the material under test permits, the procedure m…
Subclause3 – 7.3.4��� Expression of results
Clause1 – 8��� Precision
Clause1 – 9��� Test report
BS EN ISO 10548:2003