{"id":233860,"date":"2024-10-19T15:15:05","date_gmt":"2024-10-19T15:15:05","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-50289-1-12017\/"},"modified":"2024-10-25T09:46:04","modified_gmt":"2024-10-25T09:46:04","slug":"bs-en-50289-1-12017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-50289-1-12017\/","title":{"rendered":"BS EN 50289-1-1:2017"},"content":{"rendered":"
This European Standard specifies the electrical test methods for cables used in analogue and digital communication systems.<\/p>\n
Part 1 of EN 50289 consists of the following documents:<\/p>\n
Part 1-1 General requirements<\/p>\n<\/li>\n
Part 1-2 DC resistance<\/p>\n<\/li>\n
Part 1-3 Dielectric strength<\/p>\n<\/li>\n
Part 1-4 Insulation resistance<\/p>\n<\/li>\n
Part 1-5 Capacitance<\/p>\n<\/li>\n
Part 1-6 Electromagnetic performance<\/p>\n<\/li>\n
Part 1-7 Velocity of propagation<\/p>\n<\/li>\n
Part 1-8 Attenuation<\/p>\n<\/li>\n
Part 1-9 Unbalance attenuation (longitudinal conversation loss, longitudinal conversion transfer loss)<\/p>\n<\/li>\n
Part 1-10 Crosstalk<\/p>\n<\/li>\n
Part 1-11 Characteristic impedance, input impedance, return loss<\/p>\n<\/li>\n
Part 1-12 Inductance<\/p>\n<\/li>\n
Part 1-13 Coupling attenuation or screening attenuation of patch cords \/ coaxial cable assemblies \/ pre-connectorised cables<\/p>\n<\/li>\n
Part 1-14 Coupling attenuation or screening attenuation of connecting hardware<\/p>\n<\/li>\n
Part 1-15 Coupling attenuation of links and channels (Laboratory conditions)<\/p>\n<\/li>\n
Part 1-16 Coupling attenuation of cable assemblies (Field conditions)<\/p>\n<\/li>\n
Part 1-17 Exogenous Crosstalk ExNEXT and ExFEXT<\/p>\n<\/li>\n<\/ul>\n
Further test details (e.g. temperature, duration) and\/or test requirements are given in the relevant cable standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 3 Terms and definitions 4 Sampling 4.1 Cable under test (CUT) 4.2 Pre-conditioning 5 Tests 6 Test conditions 6.1 Ambient temperature 6.2 Tolerance on temperature values 6.3 Frequency and waveform of test voltages for dielectric strength test <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 6.4 Frequency range and stability for frequency related measurements 6.5 Measurement on drums 7 Measurement methods and equipment 7.1 Calibration 7.2 Requirements for balanced to unbalanced converters (Baluns) <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 7.3 Balun-less test method 7.3.1 Test equipment <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 7.3.2 Measurement precautions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7.3.3 Coaxial cables and interconnect for network analysers 7.3.4 Reference loads for calibration <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 7.3.5 Calibration 7.3.6 Termination loads for termination of conductor pairs 7.3.6.1 General <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 7.3.6.2 Verification of termination loads <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7.3.7 Termination of screens 8 Test report <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex\u00a0A (informative)Example derivation of mixed mode parametersusing the modal decomposition technique <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex\u00a0B (informative)Verification artefacts <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Communication cables. Specifications for test methods – Electrical test methods. General requirements<\/b><\/p>\n |