{"id":359660,"date":"2024-10-20T01:27:15","date_gmt":"2024-10-20T01:27:15","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-22232-12020\/"},"modified":"2024-10-26T02:10:12","modified_gmt":"2024-10-26T02:10:12","slug":"bs-en-iso-22232-12020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-22232-12020\/","title":{"rendered":"BS EN ISO 22232-1:2020"},"content":{"rendered":"
This document specifies methods and acceptance criteria within the frequency range of 0,5 MHz to 15 MHz, for assessing the electrical performance of digital ultrasonic instruments for pulse operation using A-scan display, for manual ultrasonic non-destructive testing with single- or dual-transducer probes. This document is also applicable for multi-channel instruments. This document can partly be applicable to ultrasonic instruments in automated systems, but other tests can be needed to ensure satisfactory performance.<\/p>\n
This document excludes ultrasonic instruments for continuous waves.<\/p>\n
This document also excludes ultrasonic phased array instruments, see e.g. ISO 18563-1<\/span><\/span>. If a phased array instrument has dedicated connectors for single- or dual-transducer probes this document is applicable for these channels.<\/p>\n Non-destructive testing. Characterization and verification of ultrasonic test equipment – Instruments<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 4<\/td>\n European foreword <\/td>\n<\/tr>\n \n 7<\/td>\n Foreword <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n\n 11<\/td>\n 4 Symbols <\/td>\n<\/tr>\n \n 12<\/td>\n 5 General requirements of conformity
6 Manufacturer\u2019s technical specification for ultrasonic instruments <\/td>\n<\/tr>\n\n 15<\/td>\n 7 Performance requirements for ultrasonic instruments <\/td>\n<\/tr>\n \n 17<\/td>\n 8 Group 1 tests
8.1 Equipment required for group 1 tests <\/td>\n<\/tr>\n\n 18<\/td>\n 8.2 Battery operational time
8.2.1 Procedure
8.2.2 Acceptance criterion
8.3 Stability after warm-up time
8.3.1 Procedure
8.3.2 Acceptance criteria <\/td>\n<\/tr>\n\n 19<\/td>\n 8.4 Stability against temperature
8.4.1 Procedure <\/td>\n<\/tr>\n\n 21<\/td>\n 8.4.2 Acceptance criterion
8.5 Stability against voltage variation
8.5.1 Procedure <\/td>\n<\/tr>\n\n 22<\/td>\n 8.5.2 Acceptance criterion
8.6 Time base deviation
8.6.1 Procedure <\/td>\n<\/tr>\n\n 24<\/td>\n 8.6.2 Acceptance criterion
8.7 Transmitter pulse parameters
8.7.1 General
8.7.2 Pulse repetition frequency
8.7.3 Effective output impedance <\/td>\n<\/tr>\n\n 25<\/td>\n 8.8 Receiver
8.8.1 General
8.8.2 Cross talk from transmitter to receiver during transmission <\/td>\n<\/tr>\n\n 26<\/td>\n 8.8.3 Dead time after transmitter pulse <\/td>\n<\/tr>\n \n 28<\/td>\n 8.8.4 Dynamic range and maximum input voltage <\/td>\n<\/tr>\n \n 29<\/td>\n 8.8.5 Receiver input impedance <\/td>\n<\/tr>\n \n 30<\/td>\n 8.8.6 Time-corrected gain (TCG) <\/td>\n<\/tr>\n \n 31<\/td>\n 8.9 Gates
8.9.1 General <\/td>\n<\/tr>\n\n 32<\/td>\n 8.9.2 Gates with value output <\/td>\n<\/tr>\n \n 34<\/td>\n 8.9.3 Gates with analogue output <\/td>\n<\/tr>\n \n 36<\/td>\n 8.9.4 Gates with alarm output <\/td>\n<\/tr>\n \n 37<\/td>\n 8.10 Highest digitized frequency
8.10.1 Procedure <\/td>\n<\/tr>\n\n 38<\/td>\n 8.10.2 Acceptance criterion
8.11 Response time of digital ultrasonic instruments
8.11.1 General
8.11.2 Procedure <\/td>\n<\/tr>\n\n 39<\/td>\n 8.11.3 Acceptance criterion
9 Group 2 tests
9.1 Equipment required for group 2 tests <\/td>\n<\/tr>\n\n 40<\/td>\n 9.2 Physical state and external aspects
9.2.1 Procedure
9.2.2 Acceptance criterion
9.3 Transmitter voltage, pulse rise time and duration
9.3.1 Procedure <\/td>\n<\/tr>\n\n 43<\/td>\n 9.3.2 Acceptance criteria
9.4 Receiver
9.4.1 General
9.4.2 Frequency response <\/td>\n<\/tr>\n\n 45<\/td>\n 9.4.3 Noise level <\/td>\n<\/tr>\n \n 46<\/td>\n 9.4.4 Gain linearity
9.4.5 Vertical display linearity <\/td>\n<\/tr>\n\n 48<\/td>\n Annex A (normative) Special conditions for ultrasonic instruments with logarithmic amplifiers <\/td>\n<\/tr>\n \n 49<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":359668,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-359660","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/359660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/359668"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=359660"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=359660"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=359660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}