{"id":564398,"date":"2024-11-05T18:47:37","date_gmt":"2024-11-05T18:47:37","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iec-60335-2-402018\/"},"modified":"2024-11-05T18:47:37","modified_gmt":"2024-11-05T18:47:37","slug":"iec-60335-2-402018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iec\/iec-60335-2-402018\/","title":{"rendered":"IEC 60335-2-40:2018"},"content":{"rendered":"
IEC 60335-2-40:2018 deals with the safety of electric heat pumps, including sanitary hot water heat pumps, air conditioners, and dehumidifiers incorporating motor-compressors and hydronic fan coils units, their maximum rated voltages being not more than 250 V for single phase appliances and 600 V for all other appliances. Partial units are within the scope of this International Standard.
\nAppliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. The appliances referenced above may consist of one or more factory-made assemblies. If provided in more than one assembly, the separate assemblies are to be used together, and the requirements are based on the use of matched assemblies. This standard does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817 classification, A2L refrigerants are limited to those of a molar mass of more than or equal to 42 kg\/kmol based on WCF \u2013 Worst Case Formulation as specified in ISO 817. This standard specifies particular requirements for the use of flammable refrigerants. Unless specifications are covered by this standard, including the annexes, requirements for refrigerating safety are covered by ISO 5149. Supplementary heaters, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance. For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; for appliances subjected to pressure, additional requirements may be necessary; This standard does not apply to: humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88); appliances designed exclusively for industrial processing or appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas). This sixth edition cancels and replaces the fifth edition published in 2013 and its Amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
\n– Clause 1 \u2013 limiting A2L refrigerants to those of a molar mass of more than or equal to 42 kg\/kmol;
\n– Clause 7 \u2013 added requirements for A2L refrigerants,
\n– Clause 7 \u2013 added requirement for pre-charge pipe sets, detection systems, ventilation and the resulting charge;
\n– Clause 7 \u2013 added requirements for UV-C systems;
\n– Clause 7 \u2013 added requirements for transcritical refrigerating systems;
\n– Subclause 19.7 \u2013 amended text to match the intention of the subclause;
\n– Clause 21 \u2013 added requirements for transcritical refrigerating systems;
\n– Subclause 22 \u2013 added requirements for A2L refrigerants;
\n– Subclause 22\u2013 added detection systems;
\n– Subclause 22 \u2013 added new requirements for enhanced tightness refrigerating systems;
\n– Subclause 22 \u2013 added new requirements for UV-C;
\n– Clause 23 \u2013 added new requirements for UV-C;Clause
\n– Clause 24 \u2013 added requirements for transcritical refrigerating systems;
\n– Subclause 24 \u2013 added requirements for detection systems and airflow;
\n– Clause 32 added new requirements for UV-C;
\n– Annex BB \u2013 revised to add surface temperatures;
\n– Annex DD \u2013 added requirements for A2L refrigerants and amended requirements for flammable refrigerants to exempt A2L refrigerants;
\n– Annex GG \u2013 added requirements for A2L refrigerants;
\n– Annex GG.1 \u2013 amended Table GG.1 and related wording
\n– Annex GG.7 \u2013 added requirement to test;
\n– Annex GG.8 to GG.13 \u2013 new coverage for A2L refrigerants;
\n– Annex HH \u2013 revised to take into account A2L refrigerants;
\n– Annex JJ \u2013 new coverage of allowable opening of relays and similar components to prevent ignition of A2L refrigerants;
\n– Annex KK \u2013 new coverage of test method for hot surface ignition temperature for A2L;
\n– Annex LL \u2013 new coverage of refrigerant detection systems for A2L Refrigerants;
\n– Annex MM \u2013 new coverage of refrigerant sensor location confirmation test;
\n– Annex NN \u2013 new coverage of flame arrest enclosure verification test for A2L refrigerants;
\n– Annex OO \u2013 new coverage of UV radiation conditioning
\n– Bibliography \u2013 added new references.
\nThis part 2-40 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of IEC 60335-1:2010, its Amendment 1:2013 and its Amendment 2:2016.<\/p>\n","protected":false},"excerpt":{"rendered":"
Household and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n IEC<\/b><\/a><\/td>\n 2018-01-26<\/td>\n 246<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":564411,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[374,2636],"product_tag":[],"class_list":{"0":"post-564398","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-23-120","7":"product_cat-iec","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/564398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/564411"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=564398"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=564398"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=564398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}