ASHRAE Standard 211 2018

$54.17

ASHRAE Standard 211-2018 Standard for Commercial Building Energy Audits ANSI Approved/ACCA Co-sponsored)

Published By Publication Date Number of Pages
ASHRAE 2018 32
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASHRAE/ACCA Standard 211 establishes consistent practices for conducting and reporting energy audits for commercial buildings. The standard defines the procedures required to perform Energy Audit Levels 1, 2, and 3; provides a common scope of work for these audit levels for use by building owners and others; c. establishes consistent methodology and minimum rigor of analysis required; and establishes minimum reporting requirements for the results of energy audits

PDF Catalog

PDF Pages PDF Title
1 ANSI/ASHRAE/ACCA Standard 211-2018
3 CONTENTS
4 FOREWORD
5 1. PURPOSE
2. SCOPE
2.1 This standard applies to all buildings except single-family houses, multifamily structures of three stories or fewer above grade, manufactured houses (mobile homes), and manufactured houses (modular).
3. DEFINITIONS
3.1 General. Certain terms, abbreviations, and acronyms are defined in this section for the purposes of this standard. These definitions are applicable to all sections of this standard. Terms that are not defined herein, but that are defined in stand…
3.2 Abbreviations and Acronyms
6 4. COMPLIANCE REQUIREMENTS
4.1 Compliance
5. PROCEDURES
5.1 Scope of Systems
7 Figure 1 Relationship of site energy (Esite) and building energy (Ebld).
5.2 General Procedures
8 5.3 Level 1 Procedures
9 Table 1 Building Size (Total Number of Dwelling or Commercial Units)
10 5.4 Level 2 Procedures. The Level 2 audit shall follow, and consider the findings of, a Level 1 audit. If no separate Level 1 audit has been conducted, the Level 2 audit shall comply with all of the procedural requirements for a Level 1 audit, as def…
14 5.5 Level 3 Procedures
15 6. REPORTING
6.1 Level 1 Required Elements
16 6.2 Level 2 Required Elements. The following elements are required of Level 2 energy audits. If a Level 1 energy audit has not been conducted for the site, the Level 2 required elements shall include the Level 1 requirements, in addition to the follo…
21 6.3 Level 3 Reporting. The Level 3 reporting requirements are guided by Levels 1 and 2 reporting and the selection of measures for greater definition. The information and estimates required by this section shall be included in the narrative report pr…
7. REFERENCES
22 NORMATIVE ANNEX A—COMPLIANCE FORM
23 NORMATIVE ANNEX B—ENERGY SAVINGS CALCULATIONS
24 NORMATIVE ANNEX C—REPORTING FORMS
25 INFORMATIVE ANNEX D—REPORT OUTLINES
27 INFORMATIVE ANNEX E—RECOMMENDED DATA EXCHANGE FORMATS
28 INFORMATIVE ANNEX F—BUILDING ENERGY MODEL CALIBRATION
29 INFORMATIVE ANNEX G—RISK ANALYSIS AND ASSESSMENT METHODS
30 INFORMATIVE ANNEX H—INFORMATIVE REFERENCES
ASHRAE Standard 211 2018