This British Standard specifies the performance requirements and methods of test for dry-fixed ridge and hip systems connected to timber ridge/hip battens, ridge boards or hip rafters, and for dry-fixed verge systems, which are installed with slating or tiling.

PDF Catalog

PDF Pages PDF Title
5 Foreword
7 1 Scope
2 Normative references
8 3 Terms, definitions and symbols
10 4 Material specifications and durability
12 5 Mechanical resistance
6 Ventilation for ridge and hip systems (where provided)
13 7 Rain performance
8 Geometric characteristics
14 Figure 1 — Developed width ratio
9 Marking, labelling and installation instructions
15 Annex A (normative)  Tensile strength test for ridge-roll products
16 Figure A.1 — Tensile test of ridge-roll
17 Figure A.2 — Ridge and hip-roll submerged under water for freeze–thaw test
18 Annex B (normative)  Peel adhesion test for ridge-roll products
19 Figure B.1 — Prepared test specimen
20 Figure B.2 — Peel adhesion test of ridge-roll product
21 Figure B.3 — Bending the ridge-roll
22 Annex C (normative)  Determination of wind loads
23 Figure C.1 — Basic wind speed map showing the wind zones used in Table C.1
24 Table C.1 — Peak velocity wind pressure, qp (Pa), for sites at an altitude of 100 m above sea level
26 Table C.2 — Load safety factors γQ and material safety factors γM
Table C.3 — Serviceability limits
27 Annex D (informative)  Worked examples of wind uplift and resistance calculations
29 Table D.1 — Serviceability summary for worked example in D.1
Annex E (normative)  Mechanical resistance tests for ridges, hips and verges
32 Figure E.1 — Ridge batten to rafter connector and ridge batten vertical load test
33 Figure E.2 — Hip batten to hip rafter connector vertical load test
34 Figure E.3 — Continuous verge horizontal load test (verge tiles not shown)
35 Figure E.4 — General arrangement for horizontal load tests on discontinuous verge units
36 Figure E.5 — Loading points on discontinuous verge units (verge tiles not shown)
37 Annex F (normative)  Vertical load test for wind uplift resistance of verges
38 Figure F.1 — Example of the test apparatus for determination of uplift resistance of verge units
39 Figure F.2 — Hinged top batten
42 Annex G (normative)  Rain drainage from verges test method
43 Figure G.1 — Rain drainage from verges
44 Annex H (normative)  Ridge-and-hip-roll systems side-strip-elongation test method
45 Figure H.1 — Ridge assembly for side-strip extension test
Figure H.2 — Low profile template
46 Figure H.3 — High profile template
Figure H.4 — Example of fabricated low profile template
Figure H.5 — Example of fabricated high profile template
48 Bibliography