ASTM-C958 2022
$29.79
C958-92(2022) Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
Published By | Publication Date | Number of Pages |
ASTM | 2022 | 3 |
ASTM C958-92-Reapproved2022
Active Standard: Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation
ASTM C958
Scope
1.1 This test method covers the determination of the particle size distribution of alumina or quartz powders in the range from 0.5āĪ¼m to 50 Ī¼m and having a median particle diameter from 2.5āĪ¼m to 10 Ī¼m using a sedimentation method. This test method is one of several found valuable for the measurement of particle size. Instruments used for this test method employ a constant intensity X-ray beam that is passed through a sedimenting dispersion of particles.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
alumina; gravity sedimentation; particle size; particle size distribution; quartz; sedimentation ;
ICS Code
ICS Number Code 81.060.10 (Raw materials)
DOI: 10.1520/C0958-92R22