AAMI TIR31:2008 – Process challenge devices/test packs for use in health care facilities

Published By Publication Date Number of Pages
AAMI 2008 46
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This technical information report provides information that will assist health care facilities in the selection and use of process challenge devices.

PDF Catalog

PDF Pages PDF Title
1 AAMI TIR31:2008,
Process challenge devices/test packs
for use in health care facilities
3 Title page
4 AAMI Technical Information Report
Copyright information
5 Contents
7 Glossary of equivalent standards
9 Committee representation
11 Foreword
12 Introduction
13 1 Scope
2 Normative references
14 3 Definitions and abbreviations
15 4 Historical development of PCDs
5 Selection and use of process challenge devices/test packs
17 6 Process challenge devices
6.1 PCDs for steam sterilization
6.1.1 Introduction
20 6.1.2 Description
6.1.3 Reference BI PCDs—AAMI challenge and routine BI PCDs
6.1.4 Types of BI PCDs
6.1.4.1 Commercial BI PCDs
21 6.1.4.2 Health care facility–prepared PCDs
6.1.5 Recommended practices—Application and frequency of use
6.1.5.1 AAMI challenge BI PCD
6.1.5.2 AAMI routine BI PCD
6.2 BI PCDs for ethylene oxide sterilization
6.2.1 Introduction
6.2.2 Description
22 6.2.3 Reference BI PCDs
6.2.3.1 AAMI challenge BI PCD
6.2.3.2 AAMI routine BI PCD
6.2.4 Types of BI PCDs
6.2.4.1 Commercial BI PCDs
6.2.4.2 Health care facility–prepared PCDs
6.2.5 Recommended practices—Application and frequency of use
6.2.5.1 AAMI challenge BI PCD
6.2.5.2 AAMI routine BI PCD
23 6.3 BI PCDs for table-top dry heat sterilization
6.3.1 Introduction
6.3.2 Description
6.3.3 Reference BI PCDs
6.3.4 Types of BI PCDs
6.3.4.1 Commercial BI PCDs
6.3.4.2 Health care facility–prepared BI PCDs
6.3.5 Recommended practices—Application and frequency of use
6.4 BI PCDs for hydrogen peroxide sterilization
6.4.1 Introduction
24 6.4.2 Description
6.4.3 Reference BI PCDs
6.4.4 Types of BI PCDs
6.4.4.1 Commercial BI PCDs
6.4.4.2 Health care facility–prepared PCDs
6.4.5 Recommended practices—Application and frequency of use
6.5 BI PCDs for ozone sterilization process
6.5.1 Introduction
6.5.2 Description
25 6.5.3 Reference BI PCDs
6.5.4 Types of BI PCDs
6.5.4.1 Commercial BI PCDs
6.5.4.2 Health care facility–prepared BI PCDs
6.5.5 Recommended practices—Application and frequency of use
26 Annex A Regulatory perspective
27 Annex B The Bowie-Dick test pack
B.1 Introduction
B.2 Description
B.3 Reference PCDs
28 B.4 Types of PCDs for the Bowie-Dick test
B.4.1 Commercial Bowie-Dick test packs
B.4.2 Health care facility–prepared Bowie-Dick test packs
B.5 Recommended practices—Application and frequency of use
B.6 Standards
B.6.1 International Standards
30 B.6.2 AAMI standards
B.7 Current trends
31 Annex C International perspectives on PCDs
C.1 Introduction
C.2 United States and Canadian PCDs
32 C.3 Australian PCDs
C.4 European PCDs
C.4.1 EN1422—Ethylene oxide
C.4.2 EN867-5—Steam
C.5 ISO standard PCDs
C.6 Summary
33 Annex D Development and qualification of the 16-towel PCD used for steam sterilization
D.1 Introduction
D.2 Survey and preliminary testing
34 D.3 Validation testing
D.3.1 Validation testing in gravity cycles
D.3.2 Validation testing in vacuum-assisted cycles
35 D.4 Direct comparison of the 12 × 12 × 20–inch and 16-towel PCDs
36 D.5 Summary of round-robin testing
37 D.6 Supplemental data for steam-flush pressure-pulse cycles
41 Annex E Development and qualification of the routine PCD used for ethylene oxide sterilization
E.1 Introduction
E.2 Materials and methods
E.2.1 Test strategy
E.2.2 Test laboratories
E.2.3 Sterilization equipment
E.2.4 PCD components and assembly
E.2.5 Exposure conditions
42 E.2.6 Test procedure
E.2.7 Data collected
E.3 Results
43 Annex F Historical perspective
45 Annex G Bibliography