AR ArkansasFirePreventionCode 3Vol 2012
$145.42
Arkansas Fire Prevention Code, 3 Volumes
Published By | Publication Date | Number of Pages |
AR | 2012 | 1710 |
The 3 volume set includes: 2013 Arkansas Fire Prevention Code, Volume I: Fire. Comprised of the 2012 International Fire Code®, 2013 Edition Arkansas Fire Prevention Code: Revised package and the Arkansas custom binder. 2013 Arkansas Fire Prevention Code, Volume II: Building. Comprised of the 2012 International Building Code®, 2013 Edition Arkansas Fire Prevention Code: Revision package and the Arkansas custom binder. 2013 Arkansas Fire Prevention Code, Volume III: Residential. Comprised of the 2012 International Residential Code®, 2013 Edition Arkansas Fire Prevention Code: Revision package and the Arkansas custom binder.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | WELCOME PAGE |
2 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME I FIRE |
3 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME I FIRE BASED ON THE 2012 INTERNATIONAL FIRE CODE® TITLE PAGE |
4 | COPYRIGHT |
5 | TO THE PEOPLE OF THE STATE OF ARKANSAS |
6 | FOREWORD |
8 | STATE OF ARKANSAS ARKANSAS FIRE PREVENTION CODE RULES 2012 EDITION DEFINITIONS |
9 | TABLE OF CONTENTS |
17 | PART I – ADMINISTRATIVE CHAPTER 1: SCOPE AND ADMINISTRATION PART 1—GENERAL PROVISIONS SECTION 101 SCOPE AND GENERAL REQUIREMENTS SECTION 102 APPLICABILITY |
19 | PART 2—ADMINISTRATIVE PROVISIONS SECTION 103 DEPARTMENT OF FIRE PREVENTION |
20 | SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES |
22 | SECTION 105 PERMITS SECTION 106 INSPECTIONS |
23 | SECTION 107 MAINTENANCE SECTION 108 BOARD OF APPEALS SECTION 109 VIOLATIONS |
24 | SECTION 110 UNSAFE BUILDINGS SECTION 111 STOP WORK ORDER |
25 | SECTION 112 SERVICE UTILITIES SECTION 113 FEES |
27 | CHAPTER 2: DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
57 | PART II – GENERAL SAFETY PROVISIONS CHAPTER 3: GENERAL REQUIREMENTS SECTION 301 GENERAL SECTION 302 DEFINITIONS SECTION 303 ASPHALT KETTLES SECTION 304 COMBUSTIBLE WASTE MATERIAL |
58 | SECTION 305 IGNITION SOURCES SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM |
59 | SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES SECTION 308 OPEN FLAMES |
61 | SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT SECTION 310 SMOKING |
62 | SECTION 311 VACANT PREMISES |
63 | SECTION 312 VEHICLE IMPACT PROTECTION SECTION 313 FUELED EQUIPMENT SECTION 314 INDOOR DISPLAYS SECTION 315 GENERAL STORAGE |
64 | SECTION 316 HAZARDS TO FIRE FIGHTERS |
65 | SECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS SECTION 318 LAUNDRY CARTS |
67 | CHAPTER 4: EMERGENCY PLANNING AND PREPAREDNESS SECTION 401 GENERAL SECTION 402 DEFINITIONS SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS |
68 | SECTION 404 FIRE SAFETY AND EVACUATION PLANS |
69 | SECTION 405 EMERGENCY EVACUATION DRILLS TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION |
70 | SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES SECTION 407 HAZARD COMMUNICATION SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS |
75 | PART III – BUILDING AND EQUIPMENT DESIGN FEATURES CHAPTER 5: FIRE SERVICE FEATURES SECTION 501 GENERAL SECTION 502 DEFINITIONS SECTION 503 FIRE APPARATUS ACCESS ROADS |
76 | SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS |
77 | SECTION 505 PREMISES IDENTIFICATION SECTION 506 KEY BOXES SECTION 507 FIRE PROTECTION WATER SUPPLIES |
78 | SECTION 508 FIRE COMMAND CENTER |
79 | SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE |
83 | CHAPTER 6: BUILDING SERVICES AND SYSTEMS SECTION 601 GENERAL SECTION 602 DEFINITIONS SECTION 603 FUEL-FIRED APPLIANCES |
86 | SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS |
88 | SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS |
91 | SECTION 606 MECHANICAL REFRIGERATION |
93 | SECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS |
94 | TABLE 608.1 BATTERY REQUIREMENTS |
95 | SECTION 609 COMMERCIAL KITCHEN HOODS TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY SECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE |
97 | CHAPTER 7: FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 701 GENERAL SECTION 702 DEFINITIONS SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION |
98 | SECTION 704 FLOOR OPENINGS AND SHAFTS |
99 | CHAPTER 8: INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL SECTION 802 DEFINITIONS SECTION 803 INTERIOR WALL AND CEILING FINISHAND TRIM IN EXISTING BUILDINGS |
100 | TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY |
101 | SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS |
102 | SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS |
105 | SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS |
107 | SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS |
109 | CHAPTER 9: FIRE PROTECTION SYSTEMS SECTION 901 GENERAL |
110 | TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS |
111 | SECTION 902 DEFINITIONS SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
113 | TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
115 | TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS |
117 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
121 | SECTION 905 STANDPIPE SYSTEMS |
123 | SECTION 906 PORTABLE FIRE EXTINGUISHERS TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS |
124 | TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa |
125 | SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
135 | TABLE 907.5.2.3.3 VISIBLE ALARMS |
136 | SECTION 908 EMERGENCY ALARM SYSTEMS |
137 | SECTION 909 SMOKE CONTROL SYSTEMS |
138 | EQUATION 9-1 |
139 | EQUATION 9-2 EQUATION 9-3 |
143 | SECTION 910 SMOKE AND HEAT REMOVAL TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTS |
144 | EQUATION 9-4 SECTION 911 EXPLOSION CONTROL |
145 | TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS |
146 | SECTION 912 FIRE DEPARTMENT CONNECTIONS |
147 | SECTION 913 FIRE PUMPS SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY |
149 | TABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTS |
151 | CHAPTER 10: MEANS OF EGRESS SECTION 1001 ADMINISTRATION SECTION 1002 DEFINITIONS SECTION 1003 GENERAL MEANS OF EGRESS |
153 | SECTION 1004 OCCUPANT LOAD TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT |
154 | SECTION 1005 MEANS OF EGRESS SIZING |
155 | SECTION 1006 MEANS OF EGRESS ILLUMINATION SECTION 1007 ACCESSIBLE MEANS OF EGRESS |
158 | SECTION 1008 DOORS, GATES AND TURNSTILES |
159 | TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS |
164 | SECTION 1009 STAIRWAYS |
168 | SECTION 1010 RAMPS |
170 | SECTION 1011 EXIT SIGNS |
171 | SECTION 1012 HANDRAILS |
172 | SECTION 1013 GUARDS |
173 | SECTION 1014 EXIT ACCESS |
174 | TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS |
175 | TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY SECTION 1016 EXIT ACCESS TRAVEL DISTANCE |
176 | TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCE SECTION 1017 AISLES |
177 | SECTION 1018 CORRIDORS TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING TABLE 1018.2 MINIMUM CORRIDOR WIDTH |
178 | SECTION 1019 EGRESS BALCONIES SECTION 1020 EXITS SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION |
179 | TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES |
180 | SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS |
182 | SECTION 1023 EXIT PASSAGEWAYS |
183 | SECTION 1024 LUMINOUS EGRESS PATH MARKINGS |
184 | SECTION 1025 HORIZONTAL EXITS |
185 | SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS SECTION 1027 EXIT DISCHARGE |
186 | SECTION 1028 ASSEMBLY |
187 | TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY |
190 | TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS |
191 | SECTION 1029 EMERGENCY ESCAPE AND RESCUE |
192 | SECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS |
193 | CHAPTER 11: CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS SECTION 1101 GENERAL SECTION 1102 DEFINITION SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTS |
194 | TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa —continued |
198 | SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS |
199 | TABLE 1104.9 REVOLVING DOOR SPEEDS |
201 | TABLE 1104.17.2 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy) |
202 | SECTION 1105 REQUIREMENTS FOR OUTDOOR OPERATIONS |
203 | CHAPTERS 12 THROUGH 19: RESERVED |
205 | PART IV – SPECIAL OCCUPANCIES AND OPERATIONS CHAPTER 20: AVIATION FACILITIES SECTION 2001 GENERAL SECTION 2002 DEFINITIONS SECTION 2003 GENERAL PRECAUTIONS SECTION 2004 AIRCRAFT MAINTENANCE |
206 | SECTION 2005 PORTABLE FIRE EXTINGUISHERS SECTION 2006 AIRCRAFT FUELING |
211 | SECTION 2007 HELISTOPS AND HELIPORTS |
213 | CHAPTER 21: DRY CLEANING SECTION 2101 GENERAL SECTION 2102 DEFINITIONS SECTION 2103 CLASSIFICATIONS SECTION 2104 GENERAL REQUIREMENTS SECTION 2105 OPERATING REQUIREMENTS |
214 | EQUATION 21-1 SECTION 2106 SPOTTING AND PRETREATING |
215 | SECTION 2107 DRY CLEANING SYSTEMS SECTION 2108 FIRE PROTECTION |
217 | CHAPTER 22: COMBUSTIBLE DUST-PRODUCING OPERATIONS SECTION 2201 GENERAL SECTION 2202 DEFINITION SECTION 2203 PRECAUTIONS SECTION 2204 EXPLOSION PROTECTION TABLE 2204.1 EXPLOSION PROTECTION STANDARDS |
219 | CHAPTER 23: MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2301 GENERAL SECTION 2302 DEFINITIONS SECTION 2303 LOCATION OF DISPENSING DEVICES SECTION 2304 DISPENSING OPERATIONS |
220 | SECTION 2305 OPERATIONAL REQUIREMENTS |
221 | SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES |
222 | TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS |
226 | SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES |
228 | TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES |
229 | SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES |
231 | SECTION 2311 REPAIR GARAGES |
235 | CHAPTER 24: FLAMMABLE FINISHES SECTION 2401 GENERAL SECTION 2402 DEFINITIONS SECTION 2403 PROTECTION OF OPERATIONS |
237 | SECTION 2404 SPRAY FINISHING |
240 | SECTION 2405 DIPPING OPERATIONS |
242 | SECTION 2406 POWDER COATING SECTION 2407 ELECTROSTATIC APPARATUS |
243 | SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS |
244 | SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS |
245 | CHAPTER 25: FRUIT AND CROP RIPENING SECTION 2501 GENERAL SECTION 2502 DEFINITIONS SECTION 2503 ETHYLENE GAS SECTION 2504 SOURCES OF IGNITION SECTION 2505 COMBUSTIBLE WASTE SECTION 2506 ETHYLENE GENERATORS SECTION 2507 WARNING SIGNS |
247 | CHAPTER 26: FUMIGATION AND INSECTICIDAL FOGGING SECTION 2601 GENERAL SECTION 2602 DEFINITIONS SECTION 2603 FIRE SAFETY REQUIREMENTS |
249 | CHAPTER 27: SEMICONDUCTOR FABRICATION FACILITIES SECTION 2701 GENERAL SECTION 2702 DEFINITIONS SECTION 2703 GENERAL SAFETY PROVISIONS |
253 | SECTION 2704 STORAGE |
254 | TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a |
255 | TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5 SECTION 2705 USE AND HANDLING |
256 | TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATION |
259 | CHAPTER 28: LUMBER YARDS AND WOODWORKING FACILITIES SECTION 2801 GENERAL SECTION 2802 DEFINITIONS SECTION 2803 GENERAL REQUIREMENTS SECTION 2804 FIRE PROTECTION |
260 | SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS SECTION 2806 LOG STORAGE AREAS SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES |
261 | SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS |
263 | CHAPTER 29: MANUFACTURE OF ORGANIC COATINGS SECTION 2901 GENERAL SECTION 2902 DEFINITION SECTION 2903 GENERAL PRECAUTIONS SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION |
264 | SECTION 2905 PROCESS STRUCTURES SECTION 2906 PROCESS MILLS AND KETTLES SECTION 2907 PROCESS PIPING SECTION 2908 RAW MATERIALS IN PROCESS AREAS |
265 | SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS |
267 | CHAPTER 30: INDUSTRIAL OVENS SECTION 3001 GENERAL SECTION 3002 DEFINITIONS SECTION 3003 LOCATION SECTION 3004 FUEL PIPING SECTION 3005 INTERLOCKS SECTION 3006 FIRE PROTECTION SECTION 3007 OPERATION AND MAINTENANCE |
269 | CHAPTER 31: TENTS AND OTHER MEMBRANE STRUCTURES SECTION 3101 GENERAL SECTION 3102 DEFINITIONS SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES |
270 | TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS |
271 | SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES |
275 | CHAPTER 32: HIGH-PILED COMBUSTIBLE STORAGE SECTION 3201 GENERAL SECTION 3202 DEFINITIONS SECTION 3203 COMMODITY CLASSIFICATION |
277 | SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS |
278 | FIGURE 3203.7.4 MIXED COMMODITIES |
279 | SECTION 3205 HOUSEKEEPING AND MAINTENANCE SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES |
280 | TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS |
281 | SECTION 3207 SOLID-PILED AND SHELF STORAGE SECTION 3208 RACK STORAGE |
282 | TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE SECTION 3209 AUTOMATED STORAGE |
283 | SECTION 3210 SPECIALTY STORAGE |
285 | CHAPTER 33: FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION SECTION 3301 GENERAL SECTION 3302 DEFINITIONS SECTION 3303 TEMPORARY HEATING EQUIPMENT SECTION 3304 PRECAUTIONS AGAINST FIRE SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS |
286 | SECTION 3306 FLAMMABLE GASES SECTION 3307 EXPLOSIVE MATERIALS SECTION 3308 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION SECTION 3309 FIRE REPORTING SECTION 3310 ACCESS FOR FIRE FIGHTING SECTION 3311 MEANS OF EGRESS SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION |
287 | SECTION 3313 STANDPIPES SECTION 3314 AUTOMATIC SPRINKLER SYSTEM SECTION 3315 PORTABLE FIRE EXTINGUISHERS SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT SECTION 3317 SAFEGUARDING ROOFING OPERATIONS |
289 | CHAPTER 34: TIRE REBUILDING AND TIRE STORAGE SECTION 3401 GENERAL SECTION 3402 DEFINITIONS SECTION 3403 TIRE REBUILDING SECTION 3404 PRECAUTIONS AGAINST FIRE SECTION 3405 OUTDOOR STORAGE |
290 | SECTION 3406 FIRE DEPARTMENT ACCESS SECTION 3407 FENCING SECTION 3408 FIRE PROTECTION SECTION 3409 INDOOR STORAGE ARRANGEMENT |
291 | CHAPTER 35: WELDING AND OTHER HOT WORK SECTION 3501 GENERAL SECTION 3502 DEFINITIONS SECTION 3503 GENERAL REQUIREMENTS SECTION 3504 FIRE SAFETY REQUIREMENTS |
292 | SECTION 3505 GAS WELDING AND CUTTING |
293 | SECTION 3506 ELECTRIC ARC HOT WORK SECTION 3507 CALCIUM CARBIDE SYSTEMS SECTION 3508 ACETYLENE GENERATORS SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN |
295 | CHAPTER 36: MARINAS SECTION 3601 SCOPE SECTION 3602 DEFINITIONS SECTION 3603 GENERAL PRECAUTIONS SECTION 3604 FIRE PROTECTION EQUIPMENT SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES |
297 | CHAPTERS 37 THROUGH 49: RESERVED |
299 | PART V – HAZARDOUS MATERIALS CHAPTER 50: HAZARDOUS MATERIALS—GENERAL PROVISIONS SECTION 5001 GENERAL |
301 | SECTION 5002 DEFINITIONS |
302 | SECTION 5003 GENERAL REQUIREMENTS |
304 | TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
305 | TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
306 | TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
307 | TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD |
308 | TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA |
309 | TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA |
311 | TABLE 5003.8.2 DETACHED BUILDING REQUIRED |
312 | TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS |
315 | TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP MAND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS |
316 | SECTION 5004 STORAGE |
317 | TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE |
319 | SECTION 5005 USE, DISPENSING AND HANDLING |
321 | TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE |
323 | CHAPTER 51: AEROSOLS SECTION 5101 GENERAL SECTION 5102 DEFINITIONS SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES |
324 | TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES |
325 | TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS SECTION 5105 OUTSIDE STORAGE TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS SECTION 5106 RETAIL DISPLAY |
326 | TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS |
327 | TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS SECTION 5107 MANUFACTURING FACILITIES |
329 | CHAPTER 52: COMBUSTIBLE FIBERS SECTION 5201 GENERAL SECTION 5202 DEFINITIONS SECTION 5203 GENERAL PRECAUTIONS SECTION 5204 LOOSE FIBER STORAGE |
330 | SECTION 5205 BALED STORAGE |
331 | CHAPTER 53: COMPRESSED GASES SECTION 5301 GENERAL SECTION 5302 DEFINITIONS SECTION 5303 GENERAL REQUIREMENTS |
334 | SECTION 5304 STORAGE OF COMPRESSED GASES |
335 | SECTION 5305 USE AND HANDLING OF COMPRESSED GASES SECTION 5306 MEDICAL GAS SYSTEMS |
336 | SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED |
337 | CHAPTER 54: CORROSIVE MATERIALS SECTION 5401 GENERAL SECTION 5402 DEFINITION SECTION 5403 GENERAL REQUIREMENTS SECTION 5404 STORAGE SECTION 5405 USE |
339 | CHAPTER 55: CRYOGENIC FLUIDS SECTION 5501 GENERAL SECTION 5502 DEFINITIONS SECTION 5503 GENERAL REQUIREMENTS |
341 | SECTION 5504 STORAGE TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS |
342 | TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS SECTION 5505 USE AND HANDLING |
345 | CHAPTER 56: EXPLOSIVES AND FIREWORKS SECTION 5601 GENERAL |
347 | TABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVES |
348 | SECTION 5602 DEFINITIONS |
349 | SECTION 5603 RECORD KEEPING AND REPORTING SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING |
350 | TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA |
351 | TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991 |
352 | TABLE 5604.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES ASAPPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991 |
353 | TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARD TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4 |
355 | SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS |
356 | TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARD |
358 | SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS |
359 | SECTION 5607 BLASTING |
360 | SECTION 5608 FIREWORKS DISPLAY |
361 | SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS |
363 | CHAPTER 57: FLAMMABLE AND COMBUSTIBLE LIQUIDS SECTION 5701 GENERAL SECTION 5702 DEFINITIONS |
364 | SECTION 5703 GENERAL REQUIREMENTS TABLE 5703.6.2 PIPING STANDARDS |
365 | TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONS |
366 | TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONS |
368 | SECTION 5704 STORAGE |
379 | TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES |
380 | TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA |
381 | TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES |
382 | TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS |
383 | TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUTCARTONS ON CONVENTIONAL WOOD PALLETS |
384 | TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa |
385 | TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESSWITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY |
386 | TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE ANDPALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS |
387 | TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS |
388 | SECTION 5705 DISPENSING, USE, MIXING AND HANDLING |
389 | TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1) |
392 | TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS |
394 | SECTION 5706 SPECIAL OPERATIONS |
405 | CHAPTER 58: FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 5801 GENERAL SECTION 5802 DEFINITIONS SECTION 5803 GENERAL REQUIREMENTS |
406 | SECTION 5804 STORAGE SECTION 5805 USE SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS |
407 | SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS |
409 | CHAPTER 59: FLAMMABLE SOLIDS SECTION 5901 GENERAL SECTION 5902 DEFINITIONS SECTION 5903 GENERAL REQUIREMENTS SECTION 5904 STORAGE SECTION 5905 USE SECTION 5906 MAGNESIUM |
411 | CHAPTER 60: HIGHLY TOXIC AND TOXIC MATERIALS SECTION 6001 GENERAL SECTION 6002 DEFINITIONS SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS |
412 | SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES |
415 | TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS |
417 | SECTION 6005 OZONE GAS GENERATORS |
419 | CHAPTER 61: LIQUEFIED PETROLEUM GASES |
421 | CHAPTER 62: ORGANIC PEROXIDES SECTION 6201 GENERAL SECTION 6202 DEFINITION SECTION 6203 GENERAL REQUIREMENTS SECTION 6204 STORAGE |
422 | TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES |
423 | SECTION 6205 USE |
425 | CHAPTER 63: OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS SECTION 6301 GENERAL SECTION 6302 DEFINITIONS SECTION 6303 GENERAL REQUIREMENTS |
426 | SECTION 6304 STORAGE TABLE 6304.1.2 OXIDIZER LIQUIDS AND SOLIDS—DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES TABLE 6304.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERS |
427 | TABLE 6304.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS TABLE 6304.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS TABLE 6304.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS TABLE 6304.2.2 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURES |
428 | SECTION 6305 USE SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE |
431 | CHAPTER 64: PYROPHORIC MATERIALS SECTION 6401 GENERAL SECTION 6402 DEFINITION SECTION 6403 GENERAL REQUIREMENTS SECTION 6404 STORAGE |
432 | TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURES SECTION 6405 USE |
433 | CHAPTER 65: PYROXYLIN (CELLULOSE NITRATE) PLASTICS SECTION 6501 GENERAL SECTION 6502 DEFINITIONS SECTION 6503 GENERAL REQUIREMENTS SECTION 6504 STORAGE AND HANDLING |
435 | CHAPTER 66: UNSTABLE (REACTIVE) MATERIALS SECTION 6601 GENERAL SECTION 6602 DEFINITION SECTION 6603 GENERAL REQUIREMENTS SECTION 6604 STORAGE |
436 | SECTION 6605 USE |
437 | CHAPTER 67: WATER-REACTIVE SOLIDS AND LIQUIDS SECTION 6701 GENERAL SECTION 6702 DEFINITION SECTION 6703 GENERAL REQUIREMENTS SECTION 6704 STORAGE |
438 | SECTION 6705 USE |
439 | CHAPTERS 68 THROUGH 79: RESERVED |
441 | PART VI – REFERENCED STANDARDS CHAPTER 80: REFERENCED STANDARDS AASHTO AFSI API |
442 | ASME ASTM |
443 | BHMA CA CGA |
444 | CGR CPSC DOC DOL DOTn |
445 | DOTy EN EPA FCC |
446 | ICC ISO |
447 | NEMA NFPA |
449 | UL |
450 | USC |
451 | PART VII – APPENDICES APPENDIX A: BOARD OF APPEALS |
453 | APPENDIX B: FIRE-FLOW REQUIREMENTS FOR BUILDINGS SECTION B101 GENERAL SECTION B102 DEFINITIONS SECTION B103 MODIFICATIONS SECTION B104 FIRE-FLOW CALCULATION AREA SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS SECTION B106 REFERENCED STANDARDS |
454 | TABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS |
455 | APPENDIX C: FIRE HYDRANT LOCATIONS AND DISTRIBUTION SECTION C101 GENERAL SECTION C102 LOCATION SECTION C103 NUMBER OF FIRE HYDRANTS SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS SECTION C105 DISTRIBUTION OF FIRE HYDRANTS TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS |
457 | APPENDIX D: FIRE APPARATUS ACCESS ROADS SECTION D101 GENERAL SECTION D102 REQUIRED ACCESS SECTION D103 MINIMUM SPECIFICATIONS FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS |
458 | FIGURE D103.6 FIRE LANE SIGNS SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS |
459 | SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS D108 REFERENCED STANDARDS |
461 | APPENDIX E: HAZARD CATEGORIES SECTION E101 GENERAL SECTION E102 HAZARD CATEGORIES |
465 | SECTION E103 EVALUATION OF HAZARDS |
466 | E104 REFERENCED STANDARDS |
467 | APPENDIX F: HAZARD RANKING SECTION F101 GENERAL SECTION F102 REFERENCED STANDARDS |
468 | TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES |
469 | APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS SECTION G101 GENERAL |
470 | TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS |
471 | APPENDIX H: HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS APPENDIX I: FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS APPENDIX J: BUILDING INFORMATION SIGN |
473 | APPENDIX K CHILD CARE FACILITIES COMPILATION SECTION K101 GENERAL |
478 | [B] TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY [B] TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES |
479 | TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk |
480 | [B] TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING |
485 | INDEX |
515 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME II BULDING |
516 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME II BULDING BASED ON THE 2012 INTERNATIONAL BUILDING CODE® TITLE PAGE |
517 | COPYRIGHT |
518 | TO THE PEOPLE OF THE STATE OF ARKANSAS |
519 | FOREWORD |
521 | STATE OF ARKANSAS ARKANSAS FIRE PREVENTION CODE RULES 2012 EDITION DEFINITIONS |
522 | TABLE OF CONTENTS |
530 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
532 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
533 | SECTION 105 PERMITS |
535 | SECTION 106 FLOOR AND ROOF DESIGN LOADS SECTION 107 SUBMITTAL DOCUMENTS |
538 | SECTION 108 TEMPORARY STRUCTURES AND USES SECTION 109 FEES |
539 | SECTION 110 INSPECTIONS |
540 | SECTION 111 CERTIFICATE OF OCCUPANCY SECTION 112 SERVICE UTILITIES SECTION 113 BOARD OF APPEALS SECTION 114 VIOLATIONS |
541 | SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT |
542 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
572 | CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 301 GENERAL SECTION 302 CLASSIFICATION SECTION 303 ASSEMBLY GROUP A |
573 | SECTION 304 BUSINESS GROUP B SECTION 305 EDUCATIONAL GROUP E SECTION 306 FACTORY GROUP F |
574 | SECTION 307 HIGH-HAZARD GROUP H |
576 | [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
577 | [F] TABLE 307.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
578 | [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD |
579 | SECTION 308 INSTITUTIONAL GROUP I |
580 | SECTION 309 MERCANTILE GROUP M SECTION 310 RESIDENTIAL GROUP R |
581 | SECTION 311 STORAGE GROUP S SECTION 312 UTILITY AND MISCELLANEOUS GROUP U |
584 | CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS |
587 | EQUATION 4-1 |
588 | SECTION 403 HIGH-RISE BUILDINGS |
589 | TABLE 403.2.4 MINIMUM BOND STRENGTH |
590 | SECTION 404 ATRIUMS |
591 | SECTION 405 UNDERGROUND BUILDINGS |
592 | SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES |
594 | TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT |
596 | SECTION 407 GROUP I-2 |
598 | SECTION 408 GROUP I-3 |
600 | SECTION 409 MOTION PICTURE PROJECTION ROOMS |
601 | SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS |
603 | SECTION 411 SPECIAL AMUSEMENT BUILDINGS |
604 | SECTION 412 AIRCRAFT-RELATED OCCUPANCIES TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS |
605 | [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTSa,b,c |
606 | SECTION 413 COMBUSTIBLE STORAGE SECTION 414 HAZARDOUS MATERIALS |
607 | [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS |
608 | [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS |
609 | [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA |
610 | [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa |
611 | SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5 |
612 | [F] TABLE 415.5.2 DETACHED BUILDING REQUIRED |
616 | [F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a |
620 | SECTION 416 APPLICATION OF FLAMMABLE FINISHES SECTION 417 DRYING ROOMS |
621 | SECTION 418 ORGANIC COATINGS SECTION 419 LIVE/WORK UNITS |
622 | SECTION 420 GROUPS I-1, R-1, R-2, R-3 SECTION 421 HYDROGEN CUTOFF ROOMS |
623 | SECTION 422 AMBULATORY CARE FACIILITIES SECTION 423 STORM SHELTERS SECTION 424 CHILDREN’S PLAY STRUCTURES |
626 | CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 501 GENERAL SECTION 502 DEFINITIONS SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS SECTION 504 BUILDING HEIGHT |
627 | TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREASa, b |
628 | TABLE 503—continued ALLOWABLE BUILDING HEIGHTS AND AREASa, b SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS |
629 | SECTION 506 BUILDING AREA MODIFICATIONS EQUATION 5-1 EQUATION 5-2 EQUATION 5-3 |
630 | SECTION 507 UNLIMITED AREA BUILDINGS |
632 | SECTION 508 MIXED USE AND OCCUPANCY |
633 | SECTION 509 INCIDENTAL USES |
634 | TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) SECTION 510 SPECIAL PROVISIONS |
635 | TABLE 509 INCIDENTAL USES |
638 | CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) SECTION 602 CONSTRUCTION CLASSIFICATION |
639 | TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e, h TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES |
640 | SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION |
642 | CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 701 GENERAL SECTION 702 DEFINITIONS SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS |
643 | SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS |
645 | SECTION 705 EXTERIOR WALLS TABLE 705.2 MINIMUM DISTANCE OF PROJECTION |
646 | EQUATION 7-1 FIGURE 705.7 EQUIVALENT OPENING FACTOR |
647 | TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION |
648 | EQUATION 7-2 |
649 | SECTION 706 FIRE WALLS TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS |
651 | SECTION 707 FIRE BARRIERS |
652 | TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS |
653 | SECTION 708 FIRE PARTITIONS |
654 | SECTION 709 SMOKE BARRIERS SECTION 710 SMOKE PARTITIONS |
655 | SECTION 711 HORIZONTAL ASSEMBLIES |
656 | SECTION 712 VERTICAL OPENINGS |
657 | SECTION 713 SHAFT ENCLOSURES |
659 | SECTION 714 PENETRATIONS |
661 | SECTION 715 FIRE-RESISTANT JOINT SYSTEMS |
662 | SECTION 716 OPENING PROTECTIVES |
663 | TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES |
664 | TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
665 | TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
668 | TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS |
669 | SECTION 717 DUCTS AND AIR TRANSFER OPENINGS TABLE 717.3.2.1 FIRE DAMPER RATING |
673 | SECTION 718 CONCEALED SPACES |
675 | SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS |
676 | SECTION 721 PRESCRIPTIVE FIRE RESISTANCE |
677 | TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
678 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
679 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
680 | TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
681 | TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
682 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
683 | TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
684 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
685 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
686 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
687 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
688 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p |
689 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
690 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
691 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
692 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
693 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
694 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
695 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
696 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
697 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
698 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q |
699 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q SECTION 722 CALCULATED FIRE RESISTANCE |
700 | TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING EQUATION 7-3 EQUATION 7-4 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS |
701 | TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4 TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION |
702 | TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL |
703 | TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches) FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS EQUATION 7-5 FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS |
704 | FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS |
705 | FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches) |
706 | TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE) TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS |
707 | TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches) EQUATION 7-6 |
708 | EQUATION 7-7 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLSa,b,c,d |
709 | TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches) TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches) TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS |
710 | EQUATION 7-8 EQUATION 7-9 TABLE 722.4.1(3) VALUES OF Rn 0.59 TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a TABLE 722.4.1(5) REINFORCED MASONRY LINTELS TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS EQUATION 7-10 |
711 | EQUATION 7-11 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS EQUATION 7-12 |
712 | FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS EQUATION 7-13 FIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM |
713 | FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD EQUATION 7-14 EQUATION 7-15 FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS |
714 | FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS |
715 | TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS TABLE 722.5.1(2) PROPERTIES OF CONCRETE |
716 | TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
717 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
718 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
719 | TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
720 | TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
721 | TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS |
722 | TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] |
723 | TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] |
724 | EQUATION 7-16 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS EQUATION 7-17 |
725 | TABLE 722.6.2(1) TIME ASSIGNED TO WALL BOARD MEMBRANESa, b, c, d |
726 | TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a, b, c TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION |
727 | EQUATION 7-18 EQUATION 7-19 EQUATION 7-20 EQUATION 7-21 FIGURE 722.6.3(1) LOAD FIGURE FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS |
728 | CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL SECTION 802 DEFINITIONS SECTION 803 WALL AND CEILING FINISHES |
730 | TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk |
731 | SECTION 804 INTERIOR FLOOR FINISH SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION SECTION 806 DECORATIVE MATERIALS AND TRIM |
732 | SECTION 807 INSULATION SECTION 808 ACOUSTICAL CEILING SYSTEMS |
734 | CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL SECTION 902 DEFINITIONS |
735 | SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
737 | [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
739 | [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS |
741 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
742 | SECTION 905 STANDPIPE SYSTEMS |
745 | SECTION 906 PORTABLE FIRE EXTINGUISHERS [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE |
746 | [F]TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS [F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
756 | [F] TABLE 907.5.2.3.3 VISIBLE ALARMS |
757 | SECTION 908 EMERGENCY ALARM SYSTEMS |
758 | SECTION 909 SMOKE CONTROL SYSTEMS |
759 | EQUATION 9-1 EQUATION 9-2 |
760 | EQUATION 9-3 |
765 | SECTION 910 SMOKE AND HEAT REMOVAL |
766 | EQUATION 9-4 [F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa |
767 | SECTION 911 FIRE COMMAND CENTER |
768 | SECTION 912 FIRE DEPARTMENT CONNECTIONS SECTION 913 FIRE PUMPS |
769 | SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE |
770 | CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION SECTION 1002 DEFINITIONS SECTION 1003 GENERAL MEANS OF EGRESS |
771 | SECTION 1004 OCCUPANT LOAD |
772 | TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT |
773 | SECTION 1005 MEANS OF EGRESS SIZING |
774 | SECTION 1006 MEANS OF EGRESS ILLUMINATION SECTION 1007 ACCESSIBLE MEANS OF EGRESS |
777 | SECTION 1008 DOORS, GATES AND TURNSTILES |
778 | TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS |
783 | SECTION 1009 STAIRWAYS |
787 | SECTION 1010 RAMPS |
788 | SECTION 1011 EXIT SIGNS |
789 | SECTION 1012 HANDRAILS |
790 | SECTION 1013 GUARDS |
792 | SECTION 1014 EXIT ACCESS |
793 | TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY |
794 | SECTION 1016 EXIT ACCESS TRAVEL DISTANCE TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa |
795 | SECTION 1017 AISLES SECTION 1018 CORRIDORS TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING |
796 | TABLE 1018.2 MINIMUM CORRIDOR WIDTH SECTION 1019 EGRESS BALCONIES |
797 | SECTION 1020 EXITS SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION |
798 | TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS |
800 | SECTION 1023 EXIT PASSAGEWAYS |
801 | SECTION 1024 LUMINOUS EGRESS PATH MARKINGS |
802 | SECTION 1025 HORIZONTAL EXITS |
803 | SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS |
804 | SECTION 1027 EXIT DISCHARGE |
805 | SECTION 1028 ASSEMBLY |
806 | TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY |
808 | TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS |
809 | SECTION 1029 EMERGENCY ESCAPE AND RESCUE |
812 | CHAPTER 11 ACCESSIBILITY SECTION 1101 GENERAL SECTION 1102 DEFINITIONS SECTION 1103 SCOPING REQUIREMENTS |
813 | SECTION 1104 ACCESSIBLE ROUTE |
814 | SECTION 1105 ACCESSIBLE ENTRANCES SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES |
815 | TABLE 1106.1 ACCESSIBLE PARKING SPACES SECTION 1107 DWELLING UNITS AND SLEEPING UNITS |
817 | TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS |
819 | SECTION 1108 SPECIAL OCCUPANCIES TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES |
820 | TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES |
821 | SECTION 1109 OTHER FEATURES AND FACILITIES |
823 | TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES |
824 | SECTION 1110 SIGNAGE |
826 | CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL SECTION 1202 DEFINITIONS SECTION 1203 VENTILATION |
827 | SECTION 1204 TEMPERATURE CONTROL SECTION 1205 LIGHTING |
828 | SECTION 1206 YARDS OR COURTS SECTION 1207 SOUND TRANSMISSION SECTION 1208 INTERIOR SPACE DIMENSIONS |
829 | SECTION 1209 ACCESS TO UNOCCUPIED SPACES SECTION 1210 TOILET AND BATHROOM REQUIREMENTS |
832 | CHAPTER 13 ENERGY EFFICIENCY SECTION 1301 GENERAL |
834 | CHAPTER 14 EXTERIOR WALLS SECTION 1401 GENERAL SECTION 1402 DEFINITIONS SECTION 1403 PERFORMANCE REQUIREMENTS |
835 | SECTION 1404 MATERIALS SECTION 1405 INSTALLATION OF WALL COVERINGS |
836 | TABLE 1405.3.1 CLASS III VAPOR RETARDERS TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS |
840 | SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS |
841 | TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS SECTION 1407 METAL COMPOSITE MATERIALS (MCM) |
843 | TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS |
844 | SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL) |
846 | CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL SECTION 1502 DEFINITIONS SECTION 1503 WEATHER PROTECTION |
847 | SECTION 1504 PERFORMANCE REQUIREMENTS TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION SECTION 1505 FIRE CLASSIFICATION |
848 | TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION SECTION 1506 MATERIALS SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS |
849 | TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 |
850 | TABLE 1507.2.9.2 VALLEY LINING MATERIAL |
852 | TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa, b, c |
853 | TABLE 1507.4.3(1) METAL ROOF COVERINGS TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE |
855 | TABLE 1507.7.6 SLATE SHINGLE HEADLAP |
856 | TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION |
857 | TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
858 | TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS |
859 | TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS |
860 | SECTION 1508 ROOF INSULATION TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION 1509 ROOFTOP STRUCTURES |
862 | SECTION 1510 REROOFING |
863 | SECTION 1511 SOLAR PHOTOVOLTAIC PANELS/MODULES |
864 | CHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL SECTION 1602 DEFINITIONS AND NOTATIONS SECTION 1603 CONSTRUCTION DOCUMENTS |
865 | SECTION 1604 GENERAL DESIGN REQUIREMENTS |
866 | TABLE 1604.3 DEFLECTION LIMITS |
867 | TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES |
868 | SECTION 1605 LOAD COMBINATIONS |
869 | EQUATION 16-1 EQUATION 16-2 EQUATION 16-3 EQUATION 16-4 EQUATION 16-5 EQUATION 16-6 EQUATION 16-7 EQUATION 16-8 EQUATION 16-9 EQUATION 16-10 EQUATION 16-11 EQUATION 16-12 EQUATION 16-13 EQUATION 16-14 EQUATION 16-15 EQUATION 16-16 |
870 | EQUATION 16-17 EQUATION 16-18 EQUATION 16-19 EQUATION 16-20 EQUATION 16-21 EQUATION 16-22 SECTION 1606 DEAD LOADS SECTION 1607 LIVE LOADS |
871 | TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg |
872 | TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg |
873 | TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg EQUATION 16-23 |
874 | TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR, KLL EQUATION 16-24 EQUATION 16-25 |
875 | EQUATION 16-26 EQUATION 16-27 EQUATION 16-28 EQUATION 16-29 EQUATION 16-30 EQUATION 16-31 EQUATION 16-32 |
876 | SECTION 1608 SNOW LOADS TABLE 1608.2 GROUND SNOW LOADS, pg , FOR ALASKAN LOCATIONS |
877 | FIGURE 1608.2— GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf) |
878 | FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf) |
879 | SECTION 1609 WIND LOADS |
880 | TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS EQUATION 16-33 TABLE 1609.3.1 WIND SPEED CONVERSIONSa, b, c |
881 | FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES |
882 | FIGURE 1609B ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY III AND IV BUILDINGS AND OTHER STRUCTURES |
883 | FIGURE 1609C ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES |
884 | EQUATION 16-34 |
885 | EQUATION 16-35 |
886 | TABLE 1609.6.2 NET PRESSURE COEFFICIENTS, Cneta, b |
887 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b |
888 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b |
889 | TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cnet a, b SECTION 1610 SOIL LATERAL LOADS |
890 | TABLE 1610.1 LATERAL SOIL LOAD SECTION 1611 RAIN LOADS EQUATION 16-36 |
891 | [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES |
892 | [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES |
893 | [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
894 | [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA |
895 | [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII |
896 | SECTION 1612 FLOOD LOADS |
897 | SECTION 1613 EARTHQUAKE LOADS EQUATION 16-37 EQUATION 16-38 TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa a |
898 | EQUATION 16-39 EQUATION 16-40 TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT FV a TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATIONS TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION |
899 | FIGURE 1613.3.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
900 | FIGURE 1613.3.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
901 | FIGURE 1613.3.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
902 | FIGURE 1613.3.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
903 | FIGURE 1613.3.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
904 | FIGURE 1613.3.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
905 | FIGURE 1613.3.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
906 | FIGURE 1613.3.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B |
907 | SECTION 1614 ATMOSPHERIC ICE LOADS SECTION 1615 STRUCTURAL INTEGRITY |
908 | EQUATION 16-41 EQUATION 16-42 |
909 | FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES |
910 | CHAPTER 17 SPECIAL INSPECTIONS AND TESTS SECTION 1701 GENERAL SECTION 1702 DEFINITIONS SECTION 1703 APPROVALS |
911 | SECTION 1704 SPECIAL INSPECTIONS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATIONS |
913 | SECTION 1705 REQUIRED VERIFICATION AND INSPECTION TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL |
914 | TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION |
915 | TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS |
916 | TABLE 1705.7 REQUIRED VERIFICATION AND INSPECTION OF DRIVEN DEEP FOUNDATION ELEMENTS |
917 | TABLE 1705.8 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS |
920 | SECTION 1706 DESIGN STRENGTHS OF MATERIALS |
921 | SECTION 1707 ALTERNATIVE TEST PROCEDURE SECTION 1708 TEST SAFE LOAD SECTION 1709 IN-SITU LOAD TESTS SECTION 1710 PRECONSTRUCTION LOAD TESTS |
922 | SECTION 1711 MATERIAL AND TEST STANDARDS |
924 | CHAPTER 18 SOILS AND FOUNDATIONS SECTION 1801 GENERAL SECTION 1802 DEFINITIONS SECTION 1803 GEOTECHNICAL INVESTIGATIONS |
926 | SECTION 1804 EXCAVATION, GRADING AND FILL |
927 | SECTION 1805 DAMPPROOFING AND WATERPROOFING |
928 | SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS |
929 | TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES |
930 | TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c |
931 | TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c |
932 | TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c |
933 | TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES a, b, c |
934 | EQUATION 18-1 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c |
935 | EQUATION 18-2 EQUATION 18-3 SECTION 1808 FOUNDATIONS |
936 | FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES |
937 | TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′C OF CONCRETE OR GROUT TABLE 1808.8.2 MINIMUM CONCRETE COVER |
938 | SECTION 1809 SHALLOW FOUNDATIONS TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION |
939 | SECTION 1810 DEEP FOUNDATIONS |
942 | TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS |
943 | EQUATION 18-4 |
945 | EQUATION 18-5 |
946 | EQUATION 18-6 EQUATION 18-7 EQUATION 18-8 EQUATION 18-9 EQUATION 18-10 EQUATION 18-11 |
952 | CHAPTER 19 CONCRETE SECTION 1901 GENERAL SECTION 1902 DEFINITIONS SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS SECTION 1904 DURABILITY REQUIREMENTS |
953 | TABLE 1904.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f ′c) FIGURE 1904.2 WEATHERING PROBABILITY MAP FOR CONCRETE |
954 | SECTION 1905 MODIFICATIONS TO ACI 318 |
957 | SECTION 1906 STRUCTURAL PLAIN CONCRETE SECTION 1907 MINIMUM SLAB PROVISIONS SECTION 1908 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN EQUATION 19-1 SECTION 1909 ANCHORAGE TO CONCRETE—STRENGTH DESIGN |
958 | TABLE 1908.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS (pounds) SECTION 1910 SHOTCRETE |
959 | SECTION 1911 REINFORCED GYPSUM CONCRETE SECTION 1912 CONCRETE-FILLED PIPE COLUMNS |
962 | CHAPTER 20 ALUMINUM SECTION 2001 GENERAL SECTION 2002 MATERIALS |
964 | CHAPTER 21 MASONRY SECTION 2101 GENERAL SECTION 2102 DEFINITIONS AND NOTATIONS |
966 | SECTION 2103 MASONRY CONSTRUCTION MATERIALS TABLE 2103.11 CERAMIC TILE MORTAR COMPOSITIONS |
967 | SECTION 2104 CONSTRUCTION SECTION 2105 QUALITY ASSURANCE |
968 | TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY |
969 | SECTION 2106 SEISMIC DESIGN SECTION 2107 ALLOWABLE STRESS DESIGN EQUATION 21-1 SECTION 2108 STRENGTH DESIGN OF MASONRY SECTION 2109 EMPIRICAL DESIGN OF MASONRY |
970 | TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS EQUATION 21-2 |
971 | TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY SECTION 2110 GLASS UNIT MASONRY |
972 | SECTION 2111 MASONRY FIREPLACES |
973 | FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION |
974 | SECTION 2112 MASONRY HEATERS SECTION 2113 MASONRY CHIMNEYS |
977 | TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES |
978 | FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS |
979 | FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION |
980 | CHAPTER 22 STEEL SECTION 2201 GENERAL SECTION 2202 DEFINITIONS SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES SECTION 2204 CONNECTIONS SECTION 2205 STRUCTURAL STEEL SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES |
981 | SECTION 2207 STEEL JOISTS SECTION 2208 STEEL CABLE STRUCTURES |
982 | SECTION 2209 STEEL STORAGE RACKS SECTION 2210 COLD-FORMED STEEL SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION |
984 | CHAPTER 23 WOOD SECTION 2301 GENERAL SECTION 2302 DEFINITIONS SECTION 2303 MINIMUM STANDARDS AND QUALITY |
988 | SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS |
989 | TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa, b, c |
990 | TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHINGa, b TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE |
991 | TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa, b TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a, b (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports) |
992 | TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)a, b |
994 | TABLE 2304.9.1 FASTENING SCHEDULE |
995 | TABLE 2304.9.1—continued FASTENING SCHEDULE |
996 | TABLE 2304.9.1—continued FASTENING SCHEDULE |
998 | SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS EQUATION 23-1 TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c EQUATION 23-2 |
999 | TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS SECTION 2306 ALLOWABLE STRESS DESIGN |
1001 | TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION |
1002 | TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf |
1003 | TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf |
1004 | TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, g, h |
1005 | TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING |
1006 | TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, f, g, i TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLYa, b, c, d, e |
1007 | TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES |
1010 | TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/Δ = 360) |
1011 | TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/Δ = 360) |
1012 | TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/Δ = 360) |
1013 | TABLE 2308.8(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/Δ = 360) |
1014 | TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS |
1015 | FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM |
1016 | TABLE 2308.9.3(1) BRACED WALL PANELSa TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below) |
1017 | TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs) TABLE 2308.9.3(5) HARDBOARD SIDING |
1019 | FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING |
1020 | TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs) |
1021 | TABLE 2308.9.5—continued HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs) |
1022 | TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs) |
1023 | TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds) |
1024 | TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240) |
1025 | TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240) |
1026 | TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240) |
1027 | TABLE 2308.10.2(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240) |
1028 | TABLE 2308.10.3(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1029 | TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1030 | TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1031 | TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1032 | TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1033 | TABLE 2308.10.3(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1034 | TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1035 | TABLE 2308.10.3(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180) |
1036 | TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1037 | TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1038 | TABLE 2308.10.3(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1039 | TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240) |
1040 | TABLE 2308.10.4.1 RAFTER TIE CONNECTIONSg |
1042 | TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING |
1043 | TABLE 2308.10.9—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING |
1044 | FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS |
1045 | TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Percentage of Wall Bracing per each Braced Wall Linea) |
1047 | FIGURE 2308.12.6(1) BRACED WALL PANELS OUT OF PLANE FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES |
1048 | FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY |
1049 | FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS |
1050 | CHAPTER 24 GLASS AND GLAZING SECTION 2401 GENERAL SECTION 2402 DEFINITIONS SECTION 2403 GENERAL REQUIREMENTS FOR GLASS SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS EQUATION 24-1 EQUATION 24-2 EQUATION 24-3 EQUATION 24-4 |
1051 | EQUATION 24-5 EQUATION 24-6 EQUATION 24-7 EQUATION 24-8 EQUATION 24-9 EQUATION 24-10 EQUATION 24-11 EQUATION 24-12 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS |
1053 | EQUATION 24-13 EQUATION 24-14 EQUATION 24-15 SECTION 2406 SAFETY GLAZING TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201 |
1054 | TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 |
1055 | SECTION 2407 GLASS IN HANDRAILS AND GUARDS SECTION 2408 GLAZING IN ATHLETIC FACILITIES |
1056 | SECTION 2409 GLASS IN ELEVATOR HOISTWAYS AND ELEVATOR CARS |
1058 | CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL SECTION 2502 DEFINITIONS SECTION 2503 INSPECTION SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES SECTION 2505 SHEAR WALL CONSTRUCTION SECTION 2506 GYPSUM BOARD MATERIALS |
1059 | TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES SECTION 2507 LATHING AND PLASTERING TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES SECTION 2508 GYPSUM CONSTRUCTION TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION |
1060 | TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO) |
1061 | SECTION 2511 INTERIOR PLASTER TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION SECTION 2512 EXTERIOR PLASTER |
1062 | TABLE 2512.6 CEMENT PLASTERS SECTION 2513 EXPOSED AGGREGATE PLASTER |
1064 | CHAPTER 26 PLASTIC SECTION 2601 GENERAL SECTION 2602 DEFINITIONS SECTION 2603 FOAM PLASTIC INSULATION |
1067 | FIGURE 2603.9 TERMITE INFESTATION PROBABILITY MAP SECTION 2604 INTERIOR FINISH AND TRIM |
1068 | SECTION 2605 PLASTIC VENEER SECTION 2606 LIGHT-TRANSMITTING PLASTICS |
1069 | SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS |
1070 | TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS |
1071 | TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING |
1072 | SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS SECTION 2612 FIBER-REINFORCED POLYMER |
1073 | SECTION 2613 REFLECTIVE PLASTIC CORE INSULATION |
1074 | CHAPTER 27 ELECTRICAL CHAPTER 28 MECHANICAL SYSTEMS CHAPTER 29 PLUMBING SYSTEMS |
1076 | CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS SECTION 3001 GENERAL SECTION 3002 HOISTWAY ENCLOSURES SECTION 3003 EMERGENCY OPERATIONS |
1077 | SECTION 3004 HOISTWAY VENTING SECTION 3005 CONVEYING SYSTEMS |
1078 | SECTION 3006 MACHINE ROOMS SECTION 3007 FIRE SERVICE ACCESS ELEVATOR |
1079 | FIGURE 3007.7.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL |
1080 | SECTION 3008 OCCUPANT EVACUATION ELEVATORS |
1082 | CHAPTER 31 SPECIAL CONSTRUCTION SECTION 3101 GENERAL SECTION 3102 MEMBRANE STRUCTURES |
1083 | SECTION 3103 TEMPORARY STRUCTURES SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS |
1084 | SECTION 3105 AWNINGS AND CANOPIES SECTION 3106 MARQUEES |
1085 | SECTION 3107 SIGNS SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES |
1086 | SECTION 3110 AUTOMATIC VEHICULAR GATES SECTION 3111 SOLAR PHOTOVOLTAIC PANELS/MODULES |
1088 | CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY SECTION 3201 GENERAL SECTION 3202 ENCROACHMENTS |
1090 | CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION SECTION 3301 GENERAL SECTION 3302 CONSTRUCTION SAFEGUARDS SECTION 3303 DEMOLITION SECTION 3304 SITE WORK |
1091 | SECTION 3305 SANITARY SECTION 3306 PROTECTION OF PEDESTRIANS TABLE 3306.1 PROTECTION OF PEDESTRIANS |
1092 | SECTION 3307 PROTECTION OF ADJOINING PROPERTY SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY SECTION 3309 FIRE EXTINGUISHERS SECTION 3310 MEANS OF EGRESS SECTION 3311 STANDPIPES |
1093 | SECTION 3312 AUTOMATIC SPRINKLER SYSTEM SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION |
1094 | CHAPTER 34 EXISTING STRUCTURES SECTION 3401 GENERAL |
1095 | SECTION 3402 DEFINITIONS SECTION 3403 ADDITIONS SECTION 3404 ALTERATIONS |
1096 | SECTION 3405 REPAIRS |
1097 | SECTION 3406 FIRE ESCAPES |
1098 | SECTION 3407 GLASS REPLACEMENT SECTION 3408 CHANGE OF OCCUPANCY SECTION 3409 HISTORIC BUILDINGS SECTION 3410 MOVED STRUCTURES SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS |
1100 | TABLE 3411.8.5 RAMPS SECTION 3412 COMPLIANCE ALTERNATIVES |
1102 | EQUATION 34-1 EQUATION 34-2 EQUATION 34-3 EQUATION 34-4 |
1103 | TABLE 3412.6.3 COMPARTMENTATION VALUES TABLE 3412.6.4 SEPARATION VALUES TABLE 3412.6.5 CORRIDOR WALL VALUES |
1104 | TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALUE TABLE 3412.6.6(2) CONSTRUCTION-TYPE FACTOR EQUATION 34-5 TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES |
1105 | TABLE 3412.6.10 SMOKE CONTROL VALUES TABLE 3412.6.11 MEANS OF EGRESS VALUES |
1106 | TABLE 3412.6.12 DEAD-END VALUES EQUATION 34-6 TABLE 3412.6.14 ELEVATOR CONTROL VALUES |
1107 | TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES TABLE 3412.6.16 MIXED OCCUPANCY VALUESa TABLE 3412.6.17 SPRINKLER SYSTEM VALUES |
1108 | TABLE 3412.6.18 STANDPIPE SYSTEM VALUES TABLE 3412.6.19 INCIDENTAL USE AREA VALUESa |
1109 | TABLE 3412.7 SUMMARY SHEET—BUILDING CODE |
1110 | TABLE 3412.8 MANDATORY SAFETY SCORESa TABLE 3412.9 EVALUATION FORMULASa |
1112 | CHAPTER 35 REFERENCED STANDARDS AA AAMA ACI |
1113 | AF&PA AISC AISI |
1114 | AITC ALI AMCA ANSI |
1115 | APA APSP |
1116 | ASABE ASCE/SEI ASME |
1117 | ASTM |
1123 | AWCI AWPA AWS BHMA |
1124 | CGSB CPA CPSC CSA |
1125 | CSSB DASMA DOC DOJ |
1126 | DOL DOTn EN FEMA FM |
1127 | GA HPVA HUD ICC |
1128 | ISO NAAMM NCMA |
1129 | NFPA |
1130 | PCI PTI RMI |
1131 | SDI SJI SPRI TIA TMS |
1132 | TPI UL |
1133 | ULC USC |
1134 | WDMA WRI |
1136 | APPENDIX A EMPLOYEE QUALIFICATIONS APPENDIX B BOARD OF APPEALS |
1138 | APPENDIX C GROUP U—AGRICULTURAL BUILDINGS SECTION C101 GENERAL SECTION C102 ALLOWABLE HEIGHT AND AREA TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY SECTION C103 MIXED OCCUPANCIES SECTION C104 EXITS |
1140 | APPENDIX D FIRE DISTRICTS SECTION D101 GENERAL SECTION D102 BUILDING RESTRICTIONS |
1141 | SECTION D103 CHANGES TO BUILDINGS SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT |
1142 | SECTION D106 REFERENCED STANDARDS |
1144 | APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS SECTION E101 GENERAL SECTION E102 DEFINITIONS SECTION E103 ACCESSIBLE ROUTE SECTION E104 SPECIAL OCCUPANCIES TABLE E104.3.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES |
1145 | SECTION E105 OTHER FEATURES AND FACILITIES SECTION E106 TELEPHONES TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES |
1146 | SECTION E107 SIGNAGE SECTION E108 BUS STOPS |
1147 | SECTION E109 TRANSPORTATION FACILITIES AND STATIONS |
1148 | SECTION E110 AIRPORTS SECTION E111 REFERENCED STANDARDS |
1150 | APPENDIX F RODENTPROOFING APPENDIX G FLOOD-RESISTANT CONSTRUCTION APPENDIX H SIGNS APPENDIX I PATIO COVERS APPENDIX J GRADING APPENDIX K ADMINISTRATIVE PROVISIONS APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD |
1152 | INDEX |
1190 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME III RESIDENTIAL |
1191 | 2012 ARKANSAS FIRE PREVENTION CODE VOLUME III RESIDENTIAL BASED ON THE 2012 INTERNATIONAL RESIDENTIAL CODE® TITLE PAGE |
1192 | COPYRIGHT |
1193 | TO THE PEOPLE OF THE STATE OF ARKANSAS |
1194 | FOREWORD |
1196 | STATE OF ARKANSAS ARKANSAS FIRE PREVENTION CODE RULES 2012 EDITION DEFINITIONS |
1197 | TABLE OF CONTENTS |
1199 | PART I—ADMINISTRATIVE CHAPTER 1: SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION R101 GENERAL SECTION R102 APPLICABILITY |
1200 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION R103 DEPARTMENT OF BUILDING SAFETY SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL |
1201 | SECTION R105 PERMITS |
1203 | SECTION R106 CONSTRUCTION DOCUMENTS |
1204 | SECTION R107 TEMPORARY STRUCTURES AND USES SECTION R108 FEES SECTION R109 INSPECTIONS |
1205 | SECTION R110 CERTIFICATE OF OCCUPANCY SECTION R111 SERVICE UTILITIES |
1206 | SECTION R112 BOARD OF APPEALS SECTION R113 VIOLATIONS SECTION R114 STOP WORK ORDER |
1207 | PART II-DEFINITIONS CHAPTER 2: DEFINITIONS SECTION R201 GENERAL SECTION R202 DEFINITIONS |
1221 | PART III-BUILDING PLANNING AND CONSTRUCTION CHAPTER 3: BUILDING PLANNING SECTION R301 DESIGN CRITERIA |
1222 | TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA |
1223 | TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B |
1224 | TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) FIGURE R301.2(1) ISOLINES OF THE 97 1/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES |
1225 | FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D |
1226 | FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D |
1227 | FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D |
1228 | FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D |
1229 | FIGURE R301.2 (2) —continuedSEISMIC DESIGN CATEGORIES—SITE CLASS D |
1230 | FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE |
1231 | FIGURE R301.2(4)A BASIC WIND SPEEDS |
1232 | FIGURE R301.2(4)B REGIONS WHERE WIND DESIGN IS REQUIRED |
1233 | FIGURE R301.2(4)C WIND-BORNE DEBRIS REGIONS |
1234 | FIGURE R301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES |
1235 | FIGURE R301.2(5)—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES |
1236 | FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP |
1237 | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDS |
1238 | TABLE R301.2.1.5.1 BASIC WIND MODIFICATION FOR TOPOGRAPHIC WIND EFFECT |
1239 | FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION |
1240 | TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa |
1243 | TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION |
1244 | TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS SECTION R302 FIRE-RESISTANT CONSTRUCTION TABLE R302.1(1) EXTERIOR WALLS |
1245 | TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS WITH FIRE SPRINKLERS |
1247 | TABLE R302.6 DWELLING/GARAGE SEPARATION |
1249 | SECTION R303 LIGHT, VENTILATION AND HEATING |
1250 | SECTION R304 MINIMUM ROOM AREAS SECTION R305 CEILING HEIGHT SECTION R306 SANITATION SECTION R307 TOILET, BATH AND SHOWER SPACES |
1251 | SECTION R308 GLAZING FIGURE R307.1 MINIMUM FIXTURE CLEARANCES |
1252 | TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201 TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 |
1254 | SECTION R309 GARAGES AND CARPORTS SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS |
1255 | SECTION R311 MEANS OF EGRESS |
1258 | SECTION R312 GUARDS AND WINDOW FALL PROTECTION SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS |
1259 | SECTION R314 SMOKE ALARMS SECTION R315 CARBON MONOXIDE ALARMS |
1260 | SECTION R316 FOAM PLASTIC |
1261 | SECTION R317 PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY |
1263 | SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES |
1264 | SECTION R319 SITE ADDRESS SECTION R320 ACCESSIBILITY SECTION R321 ELEVATORS AND PLATFORM LIFTS SECTION R322 FLOOD-RESISTANT CONSTRUCTION |
1267 | SECTION R323 STORM SHELTERS |
1269 | CHAPTER 4: FOUNDATIONS SECTION R401 GENERAL TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa SECTION R402 MATERIALS |
1270 | TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SECTION R403 FOOTINGS |
1271 | FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS |
1272 | FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
1273 | FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
1274 | TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS (inches) FIGURE R403.1.3.2 DOWELS FOR SLABS-ON-GROUND WITH TURNED-DOWN FOOTINGS |
1276 | FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES |
1278 | FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST PROTECTED FOOTINGS IN HEATED BUILDINGS TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS |
1279 | FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD |
1280 | TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY |
1281 | TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY |
1282 | TABLE R403.3(2)—continuedAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY |
1283 | TABLE R403.3(2) —continuedAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY |
1284 | TABLE R403.3(2)— edAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY |
1285 | FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE |
1286 | FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches) |
1287 | FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING SECTION R404 FOUNDATION AND RETAINING WALLS |
1288 | TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS |
1289 | TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHES |
1290 | TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHES |
1291 | TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHES |
1292 | TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS |
1293 | TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
1294 | TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS |
1295 | TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
1296 | TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS |
1297 | TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS |
1298 | TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS |
1299 | TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLS |
1300 | TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
1302 | FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS |
1304 | TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure) |
1305 | SECTION R405 FOUNDATION DRAINAGE TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM |
1306 | SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING |
1307 | SECTION R407 COLUMNS SECTION R408 UNDER-FLOOR SPACE |
1309 | CHAPTER 5: FLOORS SECTION R501 GENERAL SECTION R502 WOOD FLOOR FRAMING |
1310 | FIGURE R502.2 FLOOR CONSTRUCTION |
1311 | TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
1312 | TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
1313 | TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
1314 | TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES |
1315 | TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCON TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY |
1317 | TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS |
1318 | TABLE R502.5(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS TABLE R502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS |
1319 | FIGURE R502.8 CUTTING, NOTCHING AND DRILLING |
1320 | SECTION R503 FLOOR SHEATHING TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENT |
1321 | TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND) |
1322 | SECTION R505 STEEL FLOOR FRAMING TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES |
1323 | TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS FIGURE R505.1.2 IN-LINE FRAMING FIGURE R505.2(1) C-SHAPED SECTION |
1324 | FIGURE R505.2(2) TRACK SECTION TABLE R505.2.4 SCREW SUBSTITUTION FACTOR |
1325 | FIGURE R505.2.5.1 FLOOR JOIST WEB HOLES FIGURE R505.2.5.3 WEB HOLE PATCH |
1326 | TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION |
1327 | TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION |
1328 | FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION |
1329 | FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION |
1330 | FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL |
1331 | FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS |
1332 | TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANS |
1333 | TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANS |
1334 | TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANS |
1335 | FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID) FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP) |
1336 | FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS |
1337 | FIGURE R505.3.4(2) BEARING STIFFENER TABLE R505.3.4(1) CLIP ANGLE BEARING STIFFENERS |
1338 | TABLE R505.3.4(2) CLIP ANGLE BEARING STIFFENERS TABLE R505.3.4(3) CLIP ANGLE BEARING STIFFENERS |
1339 | TABLE R505.3.4(4) CLIP ANGLE BEARING STIFFENERS FIGURE R505.3.7 TRACK SPLICE |
1340 | FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING SECTION R506 CONCRETE FLOORS (ON GROUND) |
1341 | FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING |
1342 | FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING SECTION R507 DECKS |
1343 | TABLE R507.2 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGER AND A 2-INCH-NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOIST TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS FIGURE R507.2.1(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS |
1344 | FIGURE R507.2.1(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS FIGURE 507.2.3 DECK ATTACHMENT FOR LATERAL LOADS |
1345 | CHAPTER 6: WALL CONSTRUCTION SECTION R601 GENERAL SECTION R602 WOOD WALL FRAMING |
1346 | TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
1347 | TABLE R602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
1348 | TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1) |
1349 | TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS |
1350 | FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING |
1351 | FIGURE R602.3(2) FRAMING DETAILS |
1352 | TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESSIN SEISMIC DESIGN CATEGORIES |
1353 | TABLE R602.3.1—continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 MPH OR LESSIN SEISMIC DESIGN CATEGORIES |
1355 | FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
1356 | FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING |
1357 | TABLE R602.7.1 SPANS FOR MINIMUM No.2 GRADE SINGLE HEADER |
1358 | FIGURE R602.7.1(1) SINGLE MEMBER HEADER IN EXTERIOR BEARING WAL FIGURE R602.7.1(2) ALTERNATIVE SINGLE MEMBER HEADER WITHOUT CRIPPLE |
1359 | TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERS FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION |
1360 | FIGURE R602.10.1.1 BRACED WALL LINES TABLE R602.10.1.3 BRACED WALL LINE SPACING |
1361 | FIGURE R602.10.1.4 ANGLED WALLS |
1362 | FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS |
1363 | TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED |
1364 | TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED |
1365 | TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING |
1366 | TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY |
1367 | TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY |
1368 | TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING |
1369 | TABLE R602.10.4 BRACING METHODS |
1370 | TABLE R602.10.4—continued BRACING METHODS |
1372 | TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS |
1373 | FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS |
1374 | FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS |
1375 | FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C |
1376 | FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION |
1377 | TABLE R602.10.6.4 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHOD PFH, PFG AND CS-PF BRACED WALL PANELS |
1378 | TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS |
1379 | FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2 |
1380 | FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING |
1381 | FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMINGFor SI: 1 inch = 25.4 mm.FIGURE R602.10.8(2)BRACED WALL FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING |
1382 | FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS |
1383 | FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES FIGURE R602.10.8.2 (3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES |
1384 | FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS |
1385 | FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION |
1386 | FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING |
1387 | TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE |
1388 | FIGURE R602.12.5 BRACING UNIT DISTRIBUTION SECTION R603 STEEL WALL FRAMING |
1389 | FIGURE R603.1.2 IN-LINE FRAMING FIGURE R603.2(1) C-SHAPED SECTION FIGURE R603.2(2) TRACK SECTION |
1390 | TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS TABLE R603.2.4 SCREW SUBSTITUTION FACTOR |
1391 | FIGURE R603.2.5.1 WEB HOLES FIGURE R603.2.5.3 STUD WEB HOLE PATCH |
1392 | TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS |
1393 | TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTSa, b, c FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION |
1394 | FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION |
1395 | TABLE R603.3.2(1) WALL FASTENING SCHEDULE TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL |
1396 | TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL |
1397 | TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL |
1398 | TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL |
1399 | TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL |
1400 | TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL |
1401 | TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL |
1402 | TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL |
1403 | TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 KSI STEEL |
1404 | TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 50 KSI STEEL |
1405 | TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1406 | TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1407 | TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1408 | TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1409 | TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1410 | TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1411 | TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1412 | TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1413 | TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1414 | TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1415 | TABLE R603.3.2 (22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1416 | TABLE R603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1417 | TABLE R603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1418 | TABLE R603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1419 | TABLE R603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1420 | TABLE R603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1421 | TABLE R603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1422 | TABLE R603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1423 | TABLE R603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 33 KSI STEEL |
1424 | TABLE R603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c 50 KSI STEEL |
1425 | TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c 33 KSI STEEL |
1426 | TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c 50 KSI STEEL |
1427 | TABLE R603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c 33 KSI STEEL |
1428 | TABLE R603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c 50 KSI STEEL |
1429 | FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL |
1430 | FIGURE R603.3.5 TRACK SPLICE FIGURE R603.4 CORNER FRAMING |
1431 | FIGURE R603.6(1) BOX BEAM HEADER FIGURE R603.6(2) BACK-TO-BACK HEADER |
1432 | TABLE R603.6(1) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b |
1433 | TABLE R603.6(2) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b |
1434 | TABLE R603.6(3) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b |
1435 | TABLE R603.6(4) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b |
1436 | TABLE R603.6(5) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b |
1437 | TABLE R603.6(6) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b |
1438 | TABLE R603.6(7) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b |
1439 | TABLE R603.6(8) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b |
1440 | TABLE R603.6(9) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b |
1441 | TABLE R603.6(10) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b |
1442 | TABLE R603.6(11) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b |
1443 | TABLE R603.6(12) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a,b |
1444 | TABLE R603.6(13) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a,b |
1445 | TABLE R603.6(14) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a,b |
1446 | TABLE R603.6(15) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 Ksi steel)a, b |
1447 | TABLE R603.6(16) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 Ksi steel)a, b |
1448 | TABLE R603.6(17) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b |
1449 | TABLE R603.6(18) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b |
1450 | TABLE R603.6(19) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 Ksi steel)a, b |
1451 | TABLE R603.6(20) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 Ksi steel)a, b |
1452 | TABLE R603.6(21) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b |
1453 | TABLE R603.6(22) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b |
1454 | TABLE R603.6(23) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 Ksi steel)a, b |
1455 | TABLE R603.6(24) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 Ksi steel)a, b |
1456 | FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL |
1457 | TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTS FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN |
1458 | TABLE R603.8 HEAD AND SILL TRACK SPAN FIGURE R603.9.2 CORNER STUD HOLD-DOWN DETAIL |
1459 | TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS TABLE R603.9.2(2) FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS |
1460 | SECTION R604 WOOD STRUCTURAL PANELS SECTION R605 PARTICLEBOARD SECTION R606 GENERAL MASONRY CONSTRUCTION |
1461 | TABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY |
1462 | TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS |
1463 | FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF |
1464 | FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C |
1465 | FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D2 |
1466 | TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES |
1467 | TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1 TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 |
1468 | TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 TABLE R606.15.1 MINIMUM CORROSION PROTECTION SECTION R607 UNIT MASONRY |
1469 | TABLE R607.1 MORTAR PROPORTIONSa, b SECTION R608 MULTIPLE-WYTHE MASONRY |
1470 | SECTION R609 GROUTED MASONRY |
1471 | TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS |
1472 | SECTION R610 GLASS UNIT MASONRY |
1473 | FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE SECTION R611 EXTERIOR CONCRETE WALL CONSTRUCTION |
1474 | TABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLSa, b |
1475 | FIGURE R611.3(1) FLAT WALL SYSTEM FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM |
1477 | TABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS FIGURE R611.5.4(1) LAP SPLICES |
1478 | FIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION FIGURE R611.5.4(3) STANDARD HOOKS |
1479 | TABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND/OR ALTERNATIVE GRADE OF STEEL |
1480 | FIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY |
1481 | FIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING |
1482 | TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS |
1483 | TABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS |
1484 | TABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS |
1485 | TABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS |
1486 | EQUATION R6-1 |
1487 | EQUATION R6-2 TABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY |
1488 | TABLE R611.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY |
1489 | TABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY |
1490 | TABLE R611.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY |
1491 | TABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE |
1492 | TABLE R611.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE |
1493 | TABLE R611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEET TABLE R611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEET |
1494 | TABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLS |
1495 | FIGURE R611.7(1) MINIMUM SOLID WALL LENGTH |
1497 | FIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL |
1498 | FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS |
1499 | FIGURE R611.8(1) REINFORCEMENT OF OPENINGS |
1500 | FIGURE R611.8(2) LINTEL FOR FLAT WALLS FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS |
1501 | FIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS |
1502 | TABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONS |
1503 | TABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1504 | TABLE R611.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1505 | TABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1506 | TABLE R611.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1507 | TABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1508 | TABLE R611.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1509 | TABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1510 | TABLE R611.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1511 | TABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET |
1512 | TABLE R611.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET |
1513 | TABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
1514 | TABLE R611.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
1515 | TABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
1516 | TABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS |
1517 | TABLE R611.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD BEARING WALLS |
1519 | FIGURE R611.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
1520 | TABLE R611.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
1521 | FIGURE R611.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL |
1522 | TABLE R611.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
1523 | FIGURE R611.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
1524 | TABLE R611.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
1525 | FIGURE R611.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL |
1526 | TABLE R611.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1527 | FIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
1528 | TABLE R611.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
1529 | FIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
1530 | TABLE R611.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
1531 | FIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
1532 | TABLE R611.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
1533 | FIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1534 | TABLE R611.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1535 | FIGURE R611.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
1536 | TABLE R611.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULA |
1537 | FIGURE R611.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL |
1538 | TABLE R611.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1539 | FIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
1540 | TABLE R611.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
1541 | FIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1542 | TABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
1543 | SECTION R612 EXTERIOR WINDOWS AND DOORS |
1544 | FIGURE R612.7.2(1) THROUGH THE FRAME FIGURE R612.7.2(2) FRAME CLIP FIGURE R612.7.2(3) THROUGH THE FRAME FIGURE R612.7.2 (4) FRAME CLIP |
1545 | FIGURE R612.7.2(5) THROUGH THE FLANGE FIGURE R612.7.2(6) THROUGH THE FLANGE FIGURE R612.7.2(7) FRAME CLIP FIGURE R612.7.2(8) THROUGH THE FLANGE |
1546 | SECTION R613 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION TABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE TABLE R613.3.2 MINIMUM PROPERTIESa FOR ORIENTED STRAND BOARD FACER MATERIAL IN SIP WALLS |
1547 | FIGURE R613.4 SIP WALL PANEL |
1548 | TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches) |
1549 | TABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches) |
1550 | FIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS |
1551 | FIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION FIGURE R613.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION |
1552 | FIGURE R613.5(5) SIP WALL-TO-WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only) FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION |
1553 | FIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT FIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS |
1554 | FIGURE R613.9 SIP CORNER FRAMING DETAIL TABLE R613.10 MAXIMUM SPANS FOR 117/8-INCH-DEEP SIP HEADERS (feet)a |
1555 | CHAPTER 7: WALL COVERING SECTION R701 GENERAL SECTION R702 INTERIOR COVERING TABLE R702.1(1) THICKNESS OF PLASTER |
1556 | TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME |
1557 | TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
1558 | TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES |
1559 | TABLE R702.7.1 CLASS III VAPOR RETARDERS SECTION R703 EXTERIOR COVERING |
1560 | TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c (Dimensions are in inches) |
1561 | TABLE R703.4 WEATHER-RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
1562 | TABLE R703.4—continued WEATHER-RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
1564 | FIGURE R703.7 MASONRY VENEER WALL DETAILS |
1565 | FIGURE R703.7—continued MASONRY VENEER WALL DETAILS |
1566 | TABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C TABLE R703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, WOOD FRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2 |
1567 | FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS |
1568 | TABLE R703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER TABLE R703.7.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING FIGURE R703.7.3.2 MASONRY VENEER OPENING |
1569 | TABLE R703.7.4 TIE ATTACHMENT AND AIR SPACE REQUIREMENTS |
1573 | CHAPTER 8: ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL SECTION R802 WOOD ROOF FRAMING |
1575 | TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240) |
1576 | TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240) |
1577 | TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240) |
1578 | TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240) |
1579 | TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) |
1580 | TABLE R802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180) |
1581 | TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240) |
1582 | TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240) |
1583 | TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180) |
1584 | TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180) |
1585 | TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180) |
1586 | TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180) |
1587 | TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240) |
1588 | TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240) |
1589 | TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240) |
1590 | TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240) |
1591 | TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180) |
1592 | TABLE R802.5.1(7)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180) |
1593 | TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240) |
1594 | TABLE R802.5.1(8)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240) |
1595 | TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS |
1596 | FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION |
1597 | FIGURE R802.7.1.1 RAFTER NOTCH FIGURE R802.7.1.2 CEILING JOIST TAPER CUT |
1599 | SECTION R803 ROOF SHEATHING TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING SECTION R804 STEEL ROOF FRAMING |
1600 | TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTION) |
1601 | TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTION) |
1602 | FIGURE R804.1.2 IN-LINE FRAMING TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS |
1603 | TABLE R804.2.4 SCREW SUBSTITUTION FACTOR FIGURE R804.2(1) C-SHAPED SECTION FIGURE R804.2(2) TRACK SECTION |
1604 | FIGURE R804.2.5.1 WEB HOLES FIGURE R804.2.5.3 WEB HOLE PATCH |
1605 | FIGURE R804.3 STEEL ROOF CONSTRUCTION |
1606 | TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE TABLE R804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 KSI STEEL |
1607 | TABLE R804.3.1.1(2) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 KSI STEEL |
1608 | TABLE R804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 KSI STEEL |
1609 | TABLE R804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 KSI STEEL |
1610 | TABLE R804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b 33 KSI STEEL |
1611 | TABLE R804.3.1.1(6) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a,b 33 KSI STEEL |
1612 | TABLE R804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 KSI STEEL |
1613 | TABLE R804.3.1.1(8) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 KSI STEEL |
1614 | TABLE R804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTION FIGURE R804.3.1.1(1) JOIST TO RAFTER CONNECTION |
1615 | FIGURE R804.3.1.1(2) BEARING STIFFENER FIGURE R804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL |
1617 | FIGURE R804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING FIGURE R804.3.1.5 SPLICED CEILING JOISTS |
1618 | TABLE R804.3.2.1(1) ROOF RAFTER SPANSa, b, c 33 KSI STEEL |
1619 | TABLE R804.3.2.1(2) ROOF RAFTER SPANSa, b, c 50 KSI STEEL |
1620 | TABLE R804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS |
1621 | FIGURE R804.3.2.4 HIP MEMBER OR RIDGE MEMBER CONNECTION TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTER TO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTION |
1622 | TABLE R804.3.3.2 HIP MEMBER SIZES, 33 ksi STEEL TABLE R804.3.3.3 HIP SUPPORT COLUMN SIZES |
1624 | TABLE R804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE FIGURE R804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE |
1625 | TABLE R804.3.3.4(2) CONNECTION REQUIREMENTS HIP MEMBER TO HIP SUPPORT COLUMN FIGURE R804.3.3.4(2) HIP SUPPORT COLUMN |
1626 | TABLE R804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL FIGURE R804.3.3.4(3) HIP CONNECTIONS AT RIDGE |
1627 | FIGURE R804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND BOX COLUMN |
1628 | FIGURE R804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER FIGURE R804.3.6(1) ROOF OR CEILING OPENING |
1629 | FIGURE R804.3.6(2) HEADER TO TRIMMER CONNECTION TABLE R804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEET |
1630 | FIGURE R804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL TABLE R804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FEET |
1631 | FIGURE R804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL TABLE R804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FEET |
1632 | FIGURE R804.3.8(3) ROOF BLOCKING DETAIL SECTION R805 CEILING FINISHES SECTION R806 ROOF VENTILATION |
1633 | TABLE R806.5 INSULATION FOR CONDENSATION CONTROL SECTION R807 ATTIC ACCESS |
1635 | CHAPTER 9: ROOF ASSEMBLIES SECTION R901 GENERAL SECTION R902 ROOF CLASSIFICATION SECTION R903 WEATHER PROTECTION SECTION R904 MATERIALS |
1636 | SECTION R905 REQUIREMENTS FOR ROOF COVERINGS TABLE R905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158 TABLE R905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 |
1638 | TABLE R905.2.8.2 VALLEY LINING MATERIAL |
1639 | TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
1641 | TABLE R905.6.5 SLATE SHINGLE HEADLAP TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS |
1642 | TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
1643 | TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
1644 | TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS |
1645 | TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS |
1646 | TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS SECTION R906 ROOF INSULATION TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION R907 REROOFING |
1649 | CHAPTER 10: CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES |
1650 | TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
1651 | FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS |
1652 | FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES SECTION R1002 MASONRY HEATERS |
1653 | SECTION R1003 MASONRY CHIMNEYS |
1655 | TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES |
1656 | FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS |
1657 | FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES FIGURE R1003.20 CHIMNEY CRICKET TABLE R1003.20 CRICKET DIMENSIONS SECTION R1004 FACTORY-BUILT FIREPLACES |
1658 | SECTION R1005 FACTORY-BUILT CHIMNEYS SECTION R1006 EXTERIOR AIR SUPPLY |
1659 | PART IV-ENERGY CONSERVATION CHAPTER 11: [RE] ENERGY EFFICIENCY |
1661 | PART V MECHANICAL CHAPTER 12: MECHANICAL ADMINISTRATION CHAPTER 13: GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 14: HEATING AND COOLING EQUIPMENT AND APPLIANCES CHAPTER 15: EXHAUST SYSTEMS CHAPTER 16: DUCT SYSTEMS CHAPTER 17: COMBUSTION AIR |
1662 | CHAPTER 18: CHIMNEYS AND VENTS CHAPTER 19: SPECIAL APPLIANCES, EQUIPMENT AND SYSTEMS CHAPTER 20: BOILERS AND WATER HEATERS CHAPTER 21: HYDRONIC PIPING CHAPTER 22: SPECIAL PIPING AND STORAGE SYSTEMS CHAPTER 23: SOLAR ENERGY SYSTEMS |
1663 | PART VI-FUEL GAS CHAPTER 24: FUEL GAS |
1665 | PART VII-PLUMBING CHAPTER 25: PLUMBING ADMINISTRATION CHAPTER 26: GENERAL PLUMBING REQUIREMENTS CHAPTER 27: PLUMBING FIXTURES CHAPTER 28: WATER HEATERS CHAPTER 29: WATER SUPPLY AND DISTRIBUTION CHAPTER 30: SANITARY DRAINAGE |
1666 | CHAPTER 31: VENTS CHAPTER 32: TRAPS CHAPTER 33: STORM DRAINAGE |
1667 | PART VIII-ELECTRICAL CHAPTER 34: GENERAL REQUIREMENTS CHAPTER 35: ELECTRICAL DEFINITIONS CHAPTER 36: SERVICES CHAPTER 37: BRANCH CIRCUIT AND FEEDER REQUIREMENTS CHAPTER 38: WIRING METHODS CHAPTER 39: POWER AND LIGHTING DISTRIBUTION CHAPTER 40: DEVICES AND LUMINAIRES |
1668 | CHAPTER 41: APPLIANCE INSTALLATION CHAPTER 42: SWIMMING POOLS CHAPTER 43: CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS |
1669 | PART IX-REFERENCED STANDARDS CHAPTER 44 REFERENCED STANDARDS AAMA ACI ACCA |
1670 | AFPA AISI AITC ANSI |
1671 | APA |
1672 | APSP ASCE/SEI ASHRAE ASME |
1674 | ASSE ASTM |
1683 | AWPA AWS AWWA |
1684 | CGSB CISPI CPA CPSC |
1685 | CSA |
1686 | CSSB DASMA DOC |
1687 | DOTn FEMA FM GA |
1688 | HPVA HVI ICC ISO MSS |
1689 | NAIMA NCMA NFPA NSF |
1690 | PCA SBCA SMACNA TMS TPI |
1691 | UL |
1692 | ULC US-FTC WDMA |
1693 | APPENDIX A: SIZING AND CAPACITIES OF GAS PIPING APPENDIX B: SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS APPENDIX C: EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS APPENDIX D: RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION APPENDIX E: MANUFACTURED HOUSING USED AS DWELLINGS APPENDIX F: RADON CONTROL METHODS |
1694 | APPENDIX G: SWIMMING POOLS, SPAS AND HOT TUBS APPENDIX H: PATIO COVERS APPENDIX I: PRIVATE SEWAGE DISPOSAL APPENDIX J EXISTING BUILDINGS AND STRUCTURES APPENDIX K: SOUND TRANSMISSION APPENDIX L: PERMIT FEES APPENDIX M: HOME DAY CARE—R-3 OCCUPANCY |
1695 | APPENDIX N: VENTING METHODS APPENDIX O: AUTOMATIC VEHICULAR GATES APPENDIX P: SIZING OF WATER PIPING SYSTEM APPENDIX Q: ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS/NATIONAL ELECTRICAL CODE CROSS REFERENCE |
1697 | INDEX |