ASHRAE Standard 15-2016 (packaged w/ Standard 34-2016) — Safety Standard for Refrigeration Systems and Designation and Classification of Refrigerants (ANSI Approved)

Published By Publication Date Number of Pages
ASHRAE 2016 88
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASHRAE Standard 15 establishes safeguards for life, limb, health, and property and prescribes safety requirements. This standard is directed toward the safety of persons and property on or near the premises where refrigeration facilities are located. It includes specifications for fabrication of tight systems but does not address the effects of refrigerant emissions on the environment. This standard applies to (a) the design, construction, test, installation, operation, and inspection of mechanical and absorption refrigeration systems, including heat pump systems used in stationary applications; (b) modifications including replacement of parts or components if they are not identical in function and capacity; and (c) substitutions of refrigerant having a different designation. The 2016 edition incorporates Addenda a, b, c, e, g to ASHRAE Standard 15-2013, which comprise the following changes to the 2013 edition: Incorporated changes to improve in the safe design, construction,installation, and operation of refrigeration systems. Updated requirements for safety relief systems, including revisions to relief vent pipe discharge locations and design provisions for headered relief vent systems Updated design pressure requirements applicable to systems using carbon dioxide; Modified overpressure protection for heat exchangers and pressure limiting devices for positive displacement compressors. ASHRAE Standard 34 is intended to establish a simple means of referring to common refrigerants instead of using the chemical name, formula, or trade name. It establishes a uniform system for assigning reference numbers, safety classifications, and refrigerant concentration limits to refrigerants. The standard also identifies requirements to apply for designations and safety classifications for refrigerants and to determine refrigerant concentration limits. This standard provides an unambiguous system for numbering refrigerants and assigning composition-designating prefixes for refrigerants. Safety classifications based on toxicity and flammability data are included along with refrigerant concentration limits for the refrigerants. This standard does not imply endorsement or concurrence that individual refrigerant blends are suitable for any particular application. The 2016 edition incorporates the 35 approved and published addenda to Standard 34-2013. Among the key changes to the 2016 edition are the following: Added thirty new refrigerants. Changed the source of the WEEL (Workplace Environmental Exposure Levels) values from AIHA (American Industrial Hygiene Association) to TERA OARS-WEEL (Toxicology Excellence for Risk Assessment/Occupational Alliance for Risk Science). Changed requirements for the refrigerant application process. Changed the requirement for submission of standard test result data to validate the method used to determine burning velocity. Changed units required for refrigerant designation to require the submission of dual units. Revised R-744 toxicity data for the RCL, LC 50, cardiac sensitization NOEL, anesthesia NOEL, ATEL, RCL, and ATEL source.

PDF Catalog

PDF Pages PDF Title
1 ASHRAE-15-2016
ANSI/ASHRAE Standard 15-2016
3 CONTENTS
4 FOREWORD
5 1. PURPOSE
2. SCOPE
3. DEFINITIONS
8 4. OCCUPANCY CLASSIFICATION
9 5. REFRIGERATING SYSTEM CLASSIFICATION
6. REFRIGERANT SAFETY CLASSIFICATION
7. RESTRICTIONS ON REFRIGERANT USE
11 8. INSTALLATION RESTRICTIONS
13 9. DESIGN AND CONSTRUCTION OF EQUIPMENT AND SYSTEMS
25 10. OPERATION AND TESTING
26 11. GENERAL REQUIREMENTS
27 12. PRECEDENCE WITH CONFLICTING REQUIREMENTS
28 INFORMATIVE APPENDIX A—INFORMATIVE REFERENCES
29 NORMATIVE APPENDIX B—NORMATIVE REFERENCES
30 INFORMATIVE APPENDIX C—METHOD FOR CALCULATING DISCHARGE CAPACITY OF POSITIVE DISPLACEMENT COMPRESSOR PRESSURE RELIEF DEVICE
32 INFORMATIVE APPENDIX D—TYPICAL MOODY FRICTION FACTORS FOR USE IN RELIEF PIPING LINE LENGTH LIMIT
33 INFORMATIVE APPENDIX E—EMERGENCIES IN REFRIGERATING MACHINERY ROOMS
35 INFORMATIVE APPENDIX F—ADDENDA DESCRIPTION INFORMATION
41 ASHRAE-34-2016
ANSI/ASHRAE Standard 34-2016
43 CONTENTS
44 FOREWORD
1. PURPOSE
2. SCOPE
3. DEFINITIONS OF TERMS
47 4. NUMBERING OF REFRIGERANTS
56 5. DESIGNATION
57 6. SAFETY GROUP CLASSIFICATIONS
60 7. REFRIGERANT CONCENTRATION LIMIT (RCL)
61 8. REFRIGERANT CLASSIFICATIONS
9. APPLICATION INSTRUCTIONS
64 10. REFERENCES
66 INFORMATIVE APPENDIX A—ISOMER DESIGNATION EXAMPLES
68 NORMATIVE APPENDIX B—DETAILS OF TESTING—FLAMMABILITY
71 INFORMATIVE APPENDIX C—BIBLIOGRAPHY
72 INFORMATIVE APPENDIX D—REFRIGERANT DATA
78 INFORMATIVE APPENDIX E—TOXICITY AND FLAMMABILITY DATA FOR SINGLE-COMPOUND REFRIGERANTS
81 INFORMATIVE APPENDIX A—EXAMPLE CALCULATIONS FOR HEATS OF COMBUSTION
82 INFORMATIVE APPENDIX G—CALCULATION OF RCL AND ATEL FOR BLENDS
83 INFORMATIVE APPENDIX H—ADDENDA DESCRIPTION INFORMATION