Shopping Cart

No products in the cart.

ASHRAE D 90452 2016

$75.29

UFAD GUIDE Design, Construction and Operation of Underfloor Air Distribution Systems

Published By Publication Date Number of Pages
ASHRAE 2016 336
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The use of underfloor air distribution systems (UFAD) is increasing as a solution to space conditioning concerns. As the use of these systems increases, so does the importance of initial design and effective operation and maintenance of these systems after installation. This set includes both UFAD and The O&M Guide for complete guidance. The UFAD guide provides assistance in the planning, construction, and operation of UFAD systems, while carefully detailing the major differences between UFAD and more traditional forms of space conditioning. UFAD GUIDE: Design, Construction, and Operation of Underfloor Air Distribution Systems incorporates updated results from laboratory and field experiments. Also included are simulation studies, manufacturer’s literature, design experiences from practicing engineers, as well as other relevant guidelines from users of UFAD. As UFAD technology is applied, designers, technicians, facility managers, and building owners or their representatives also need to know how to ensure that these often mission-critical systems operate as intended. The O&M guide supplements UFAD Guide providing specific, practical advice beyond design, construction, and startup into successful ongoing operation and maintenance. For those in the construction, building commissioning, and operations and maintenance industries, these guides provide a wealth of information on an emerging technology, all while keeping in mind the typical flow of decision making.

PDF Catalog

PDF Pages PDF Title
1 UFAD GUIDE
6 Contents
10 Acknowledgments
12 Chapter 1—Introduction
16 Chapter 2—Room Air Distribution Principles
30 Chapter 3—Underfloor Air Supply Plenum Principles
70 Chapter 4—Applications
78 Chapter 5—UFAD System Configurations
104 Chapter 6—Diffusers and Terminal Units for UFAD
114 Chapter 7—Indoor Environmental Quality
124 Chapter 8—Energy Considerations
148 Chapter 9—Standards, Codes and Ratings
166 Chapter 10—Cost Considerations
178 Chapter 11—Guidance for System Design
246 Chapter 12—Controls for UFAD Systems
266 Chapter 13—Guidance for Construction
274 Chapter 14—Guidance for Building Commissioning
304 Chapter 15—Guidance for Operation and Maintenance
312 Chapter 16—References and Bibliography
320 Terms
ASHRAE D 90452 2016
$75.29