ASHRAE UserManual 62.2 2019
$41.17
ASHRAE Standard 62.2 User’s Manual (Based on ANSI/ASHRAE Standard 62.2-2019, Ventilation And Acceptable Indoor Air Quality In Residential Buildings)
Published By | Publication Date | Number of Pages |
ASHRAE | 2019 |
This companion guide provides detailed information on the requirements of Standard 62.2-2019 and includes tables, illustrations, and examples to aid users in providing for acceptable indoor air quality in residential systems. The provisions of Standard 62.2 address mechanical and natural ventilation as well as air leakage in these buildings, and this user’s manual provides concrete examples on how to apply the criteria set out by the standard.Standard 62.2 User’s Manual does not reproduce the requirements of the standard but rather paraphrases and elaborates upon them. Intended to be used in conjunction with the standard, this manual provides: * Information on the intent and application of Standard 62.2 * Sample calculations and examples * Best practices for avoiding foul odors and irritating contaminants * Guidance for whole-building and local exhaust ventilation * Valuable information on air-moving equipment * Specific examples and background material * Useful reference material This manual is intended for residential HVAC contractors and installers, as well as residential builders, developers, and architects. It may also be useful to code officials and even discerning and technically savvy homeowners, real estate agents, and home appraisal professionals. This manual is written in clear, direct language, making it understandable to professionals and laymen alike. Standard 62.2 User’s Manual is an essential supplement for professionals concerned with ventilation and indoor air quality in residences. Use it alongside your copy of ANSI/ASHRAE Standard 62.2-2019.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Standard 62.2 User’s Manual (Based on ANSI/ASHRAE Standard 62.2-2019, Ventilation and Acceptable Indoor Air Quality in Residential Buildings) |
5 | Contents |
8 | Preface |
10 | Acknowledgements |
11 | 1 Purpose |
12 | 2 Scope |
14 | 2.1 2.2 |
16 | 3 Definitions |
17 | 4. Dwelling-Unit Ventilation |
18 | 4.1 Ventilation Rate 4.1.1 Total Ventilation Rate |
21 | 4.1.2 Infiltration Credit |
32 | 4.1.3 Different Occupant Density |
34 | 4.1.4 Ventilation-Rate Reduction for Particle Filtration |
37 | 4.2 System Type |
42 | 4.3 Airflow Measurement |
44 | 4.4 Control and Operation |
45 | 4.5 Variable Mechanical Ventilation |
47 | 4.5.1 Short-Term Ventilation |
48 | 4.5.2 Scheduled Ventilation |
52 | 4.5.3 Real-Time Control |
54 | 4.6 Equivalent Ventilation |
55 | 5 Local Exhaust 5.1 Local Mechanical Exhaust |
57 | 5.2 Demand-Controlled Mechanical Exhaust 5.2.1 Control and Operation 5.2.2 Ventilation Rate |
58 | 5.3 Continuous Mechanical Exhaust |
59 | 5.3.1 Control and Operation 5.3.2 Ventilation Rate |
60 | 5.4 Airflow Measurement |
62 | 6. Other Requirements 6.1 Adjacent Spaces and Transfer Air 6.1.1 Compliance for Attached Dwelling Units |
63 | 6.2 Instructions and Labeling |
64 | 6.3 Clothes Dryers |
65 | 6.4 Combustion and Solid-Fuel-Burning Appliances |
69 | 6.5 Airtightness Requirements 6.5.1 Garages 6.5.2 Space-Conditioning System Ducts |
70 | 6.6 Ventilation Opening Area 6.6.1 Habitable Spaces |
71 | 6.6.2 Toilets and Utility Rooms |
72 | 6.7 Minimum Filtration |
73 | 6.7.1 Filter Pressure Drop |
74 | 6.8 Air Inlets 6.8.1 Ventilation Openings |
75 | 6.9 Carbon Monoxide Alarms |
76 | 7 Air-Moving Equipment 7.1 Selection and Installation 7.2 Sound Ratings for Fans |
77 | 7.2.1 Dwelling-Unit Ventilation or Continuous Local Exhaust Fans 7.2.2 Demand-Controlled Local Exhaust Fans |
79 | 7.3 Exhaust Ducts 7.3.1 Multiple Exhaust Fans Using One Duct 7.3.2 Single Exhaust Fan Ducted to Multiple Inlets |
80 | 7.4 Supply Ducts |
81 | 8 Climate Data |
83 | 9 References |
84 | Normative Appendix A: Existing Buildings A1 Summary |
85 | A2 Dwelling-Unit Mechanical Ventilation Rate A3 Local Exhaust |
86 | A3.1 Initial Room Airflow Deficit A3.2 Window Opening Credit A3.3 Required Additional Airflow |
92 | A4 Air-Moving Equipment A4.1 Selection, Installation, and Sound Rating A4.2 Airflow Rating |
94 | A5 Dwelling-Unit Air Sealing |
96 | A6 Control and Operation of Dwelling-Unit Ventilation |
97 | Normative Appendix B: Infiltration Effectiveness Weather and Shielding Factors |
98 | Normative Appendix C: Relative Exposure C1 Summary C1.1 Target Ventilation C1.2 Time Step |
99 | C1.3 Peak Exposure Limitation C1.4 Space Volume C2 Time-Varying Total Ventilation C2.1 Mechanical Ventilation |
100 | C2.2 Infiltration |
105 | C2.3 Combination of Infiltration and Mechanical Ventilation |
106 | C3 Relative Exposure Calculation C3.1 Nonzero Ventilation C3.2 Zero Ventilation |
107 | C3.3 Initial Conditions |
108 | Informative Appendix D: Informative References |
109 | Informative Appendix E: Addenda Description Information |