ASME A112.1070 2020
$98.04
ASSE 1070-2020 / ASME A112.1070-2020 / CSA B125.70:20 Performance Requirements for Water Temperature Limiting Devices
Published By | Publication Date | Number of Pages |
ASME | 2020 |
This Standard covers water temperature limiting devices intended to limit the hot or tempered water temperature supplied to fittings for fixtures such as sinks, bidets, lavatories, and bathtubs to reduce the risk of scalding. These devices are not designed to address thermal shock.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ASSE 1070-2020/ ASME A112.1070-2020/ CSA B125.70:20, Performance requirements for water temperature limiting devices |
3 | Standards Update Service |
9 | ASME A112 Standards Committee on Plumbing Materials and Equipment |
13 | ASSE Product Standards Committee |
15 | CSA Technical Committee on Plumbing Fittings |
21 | Preface |
24 | Section I 1 Scope |
25 | Section II 2 Reference publications and definitions 2.1 Reference publications 2.2 Definitions |
26 | Section III 3 Design and general requirements 3.1 Rated pressure, flow rate, and temperature range 3.1.1 Rated pressure 3.1.2 Flow rate 3.1.3 Temperature range 3.2 End connections 3.3 Function |
27 | 3.4 Cross-flow 3.5 Toxicity and lead content 3.6 Devices incorporating electrical features |
28 | 3.7 Servicing Section IV 4 Performance requirements and test methods 4.1 General 4.1.1 Preconditioning 4.1.2 Installation for testing 4.1.3 Test sequence 4.2 High-temperature conditioning test 4.2.1 Purpose 4.2.2 Procedure |
29 | 4.2.3 Failure criteria 4.3 Working pressure and temperature test 4.3.1 General 4.3.2 Purpose 4.3.3 Procedure with the valve closed 4.3.4 Procedure with the valve opened and the outlet(s) blocked 4.3.5 Test temperatures and pressures 4.3.6 Failure criteria |
30 | 4.4 Cross-flow test 4.4.1 Purpose 4.4.2 Procedures 4.4.3 Failure criteria 4.5 Life cycle test 4.5.1 Purpose 4.5.2 Procedure 4.5.3 Failure criteria |
31 | 4.6 Pressure and temperature variation test 4.6.1 Data gathering (see Figure ) 4.6.2 Procedure (see Figure ) |
32 | 4.6.3 Failure criteria 4.7 Cold water supply failure test 4.7.1 Purpose 4.7.2 Procedure |
33 | 4.7.3 Failure criteria 4.8 Hydrostatic pressure test 4.8.1 Purpose 4.8.2 Procedure 4.8.3 Failure criteria Section V 5 Markings, packaging, instructions, and literature 5.1 Product markings 5.2 Temperature control setting identification |
34 | 5.3 Packaging 5.4 Installation and maintenance instructions 5.5 Rated flow 5.6 Water temperature |
36 | Annex A (informative)Unit conversion and rounding criteria |
37 | Annex B (informative)Verifying the time constant of the temperature-measuring equipment |