ASME A17.2 2012
$98.04
ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving Walks
Published By | Publication Date | Number of Pages |
ASME | 2012 | 292 |
This Guide covers recommended inspection and testing procedures for electric and hydraulic elevators, escalators, and moving walks required to conform to the Safety Code for Elevators and Escalators, A17.1-1955 and later editions and The Safety Code for Existing Elevators and Escalators, A17.3. This Guide also addresses some requirements from editions of A17.1 prior to 1955. NOTE: This Guide may not reflect the latest requirements in the current A17.1 and A17.3 Codes.
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | CONTENTS |
12 | FOREWORD |
15 | COMMITTEE ROSTER |
20 | PREFACE |
22 | Abbreviations Used in This Code |
23 | SUMMARY OF CHANGES |
25 | Introduction 1 SCOPE 2 APPLICATION |
26 | 3 QUALIFICATIONS OF INSPECTORS 4 PERSONAL SAFETY 5 DUTIES OF INSPECTORS |
27 | 6 ARRANGEMENT FOR INSPECTION 7 RECOMMENDED EQUIPMENT 8 REFERENCE DOCUMENTS |
28 | Table 1 Procurement Information |
29 | Part 1 Elevator — Inside of Car ITEM 1.1 DOOR REOPENING DEVICE 1.1.1 Periodic Inspections 1.1.2 Periodic Test 1.1.3 Acceptance 1.1.4 References ITEM 1.2 STOP SWITCHES 1.2.1 Periodic Inspections 1.2.2 Periodic Test 1.2.3 Acceptance 1.2.4 References |
30 | ITEM 1.3 OPERATING CONTROL DEVICES 1.3.1 Periodic Inspections 1.3.2 Periodic Test 1.3.3 Acceptance 1.3.4 References ITEM 1.4 SILLS AND CAR FLOOR 1.4.1 Periodic Inspections |
31 | 1.4.2 Periodic Test 1.4.3 Acceptance 1.4.4 References ITEM 1.5 CAR LIGHTING AND RECEPTACLES 1.5.1 Periodic Inspections 1.5.2 Periodic Test 1.5.3 Acceptance 1.5.4 References |
32 | ITEM 1.6 CAR EMERGENCY SIGNAL 1.6.1 Periodic Inspections 1.6.2 Periodic Test 1.6.3 Acceptance 1.6.4 References ITEM 1.7 CAR DOOR OR GATE 1.7.1 Periodic Inspections 1.7.2 Periodic Test 1.7.3 Acceptance |
33 | 1.7.4 References ITEM 1.8 DOOR CLOSING FORCE 1.8.1 Periodic Inspections 1.8.2 Periodic Test: Category 1 ( Annual) Test 1.8.3 Acceptance 1.8.4 References ITEM 1.9 POWER CLOSING OF DOORS OR GATES 1.9.1 Periodic Inspections 1.9.2 Periodic Test 1.9.3 Acceptance 1.9.4 References ITEM 1.10 POWER OPENING OF DOORS OR GATES 1.10.1 Periodic Inspections 1.10.2 Periodic Test |
34 | 1.10.3 Acceptance 1.10.4 References ITEM 1.11 CAR VISION PANELS AND GLASS CAR DOORS 1.11.1 Periodic Inspections 1.11.2 Periodic Test 1.11.3 Acceptance 1.11.4 References |
35 | Fig. 1.10.2 Door Operation Relative to Car Position |
36 | ITEM 1.12 CAR ENCLOSURE 1.12.1 Periodic Inspections 1.12.2 Periodic Test 1.12.3 Acceptance |
37 | 1.12.4 References ITEM 1.13 EMERGENCY EXIT 1.13.1 Periodic Inspections 1.13.2 Periodic Test 1.13.3 Acceptance 1.13.4 References ITEM 1.14 VENTILATION 1.14.1 Periodic Inspections 1.14.2 Periodic Test 1.14.3 Acceptance 1.14.4 References |
38 | ITEM 1.15 SIGNS AND OPERATING DEVICE SYMBOLS 1.15.1 Periodic Inspections 1.15.2 Periodic Test 1.15.3 Acceptance 1.15.4 References ITEM 1.16 RATED LOAD, PLATFORM AREA, AND DATA PLATE 1.16.1 Periodic Inspections 1.16.2 Periodic Test 1.16.3 Acceptance 1.16.4 References ITEM 1.17 STANDBY POWER OPERATION 1.17.1 Periodic Inspections 1.17.2 Periodic Test |
39 | 1.17.3 Acceptance 1.17.4 References ITEM 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS 1.18.1 Periodic Inspections |
40 | 1.18.2 Periodic Test 1.18.3 Acceptance 1.18.4 References ITEM 1.19 CAR RIDE 1.19.1 Periodic Inspections 1.19.2 Periodic Test 1.19.3 Acceptance 1.19.4 References ITEM 1.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 1.20.1 Periodic Inspections 1.20.2 Periodic Test 1.20.3 Acceptance 1.20.4 References |
41 | Part 2 Elevator — Machine Room ITEM 2.1 ACCESS TO MACHINE SPACE 2.1.1 Periodic Inspections 2.1.2 Periodic Test 2.1.3 Acceptance 2.1.4 References ITEM 2.2 HEADROOM 2.2.1 Periodic Inspections 2.2.2 Periodic Test 2.2.3 Acceptance 2.2.4 References ITEM 2.3 LIGHTING AND RECEPTACLES 2.3.1 Periodic Inspections 2.3.2 Periodic Test 2.3.3 Acceptance 2.3.4 References |
42 | ITEM 2.4 MACHINE SPACE 2.4.1 Periodic Inspections 2.4.2 Periodic Test 2.4.3 Acceptance 2.4.4 References ITEM 2.5 HOUSEKEEPING 2.5.1 Periodic Inspections 2.5.2 Periodic Test 2.5.3 Acceptance 2.5.4 References |
43 | ITEM 2.6 VENTILATION 2.6.1 Periodic Inspections 2.6.2 Periodic Test 2.6.3 Acceptance 2.6.4 References ITEM 2.7 FIRE EXTINGUISHER 2.7.1 Periodic Inspections 2.7.2 Periodic Test 2.7.3 Acceptance 2.7.4 References ITEM 2.8 PIPES, WIRING, AND DUCTS 2.8.1 Periodic Inspections 2.8.2 Periodic Test 2.8.3 Acceptance 2.8.4 References |
44 | ITEM 2.9 GUARDING OF EXPOSED AUXILIARY EQUIPMENT 2.9.1 Periodic Inspections 2.9.2 Periodic Test 2.9.3 Acceptance 2.9.4 References ITEM 2.10 NUMBERING OF ELEVATORS, MACHINES, CONTROLLERS, AND DISCONNECT SWITCHES 2.10.1 Periodic Inspections 2.10.2 Periodic Test 2.10.3 Acceptance 2.10.4 References ITEM 2.11 DISCONNECTING MEANS AND CONTROL 2.11.1 Periodic Inspections 2.11.2 Periodic Test 2.11.3 Acceptance |
45 | 2.11.4 References ITEM 2.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC. 2.12.1 Periodic Inspections |
46 | 2.12.2 Periodic Test 2.12.3 Acceptance 2.12.4 References ITEM 2.13 GOVERNOR, OVERSPEED SWITCH, AND SEAL 2.13.1 Periodic Inspections 2.13.2 Periodic Test |
48 | Tables Table 2.13.2.1 Governor Adjustment Settings |
49 | Figures Fig. 2.13.2.1 Dynamometer Connections for Testing the Pull- Through of Governor Jaws |
50 | 2.13.3 Acceptance |
51 | 2.13.4 References ITEM 2.14 CODE DATA PLATE 2.14.1 Periodic Inspections 2.14.2 Periodic Test 2.14.3 Acceptance 2.14.4 References ITEM 2.15 STATIC CONTROL 2.15.1 Periodic Inspections 2.15.2 Periodic Test 2.15.3 Acceptance 2.15.4 References |
52 | ITEM 2.16 OVERHEAD BEAM AND FASTENINGS 2.16.1 Periodic Inspections 2.16.2 Periodic Test 2.16.3 Acceptance 2.16.4 References ITEM 2.17 DRIVE MACHINE BRAKE 2.17.1 Periodic Inspections 2.17.2 Periodic Test |
53 | 2.17.3 Acceptance 2.17.4 References ITEM 2.18 TRACTION DRIVE MACHINES 2.18.1 Periodic Inspections 2.18.2 Periodic Test 2.18.3 Acceptance 2.18.4 References ITEM 2.19 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS 2.19.1 Periodic Inspections |
54 | 2.19.2 Periodic Test 2.19.3 Acceptance 2.19.4 References ITEM 2.20 WINDING DRUM MACHINE AND SLACK ROPE DEVICE, STOP MOTION SWITCH, AND ROPE FASTENING 2.20.1 Periodic Inspections |
55 | 2.20.2 Periodic Test 2.20.3 Acceptance 2.20.4 References ITEM 2.21 BELT- OR CHAIN- DRIVE MACHINE 2.21.1 Periodic Inspections 2.21.2 Periodic Test 2.21.3 Acceptance 2.21.4 References |
56 | ITEM 2.22 MOTOR GENERATOR 2.22.1 Periodic Inspections 2.22.2 Periodic Test 2.22.3 Acceptance Test of Generator Suicide Circuit 2.22.4 References ITEM 2.23 ABSORPTION OF REGENERATED POWER 2.23.1 Periodic Inspections 2.23.2 Periodic Test 2.23.3 Acceptance 2.23.4 References ITEM 2.24 AC DRIVES FROM A DC SOURCE 2.24.1 Periodic Inspections 2.24.2 Periodic Test 2.24.3 Acceptance 2.24.4 References |
57 | ITEM 2.25 TRACTION SHEAVES 2.25.1 Periodic Inspections 2.25.2 Periodic Test 2.25.3 Acceptance 2.25.4 References ITEM 2.26 SECONDARY AND DEFLECTOR SHEAVES 2.26.1 Periodic Inspections 2.26.2 Periodic Test 2.26.3 Acceptance 2.26.4 References ITEM 2.27 ROPE FASTENINGS 2.27.1 Periodic Inspections |
58 | 2.27.2 Periodic Test 2.27.3 Acceptance 2.27.4 References ITEM 2.28 TERMINAL STOPPING DEVICES 2.28.1 Periodic Inspections 2.28.2 Periodic Test 2.28.3 Acceptance 2.28.4 References |
59 | ITEM 2.29 CAR AND COUNTERWEIGHT SAFETIES 2.29.1 Periodic Inspections 2.29.2 Periodic Test Table 2.29.2( a) Maximum Safety Rope Pullout |
61 | Table 2.29.2( b) Minimum and Maximum Stopping Distances for Type B Car Safeties With Rated Load, and Type B Counterweight Safeties With No Load in the Car |
62 | Table 2.29.2( c) Gradual Wedge Clamp Safety Table 2.29.2( d) Flexible Guide Clamp Safety Table 2.29.2( e) Wedge Clamp Safety ( Constant Retarding Force) |
63 | Fig. 2.29.2( a) Safety Marks on Guide Rails, Poor Illumination Fig. 2.29.2( b) Safety Marks on Guide Rails, Good Illumination |
64 | 2.29.3 Acceptance Test of Governor and Safeties 2.29.4 References ITEM 2.30 HYDRAULIC POWER UNIT 2.30.1 Periodic Inspections 2.30.3 Acceptance 2.30.4 References ITEM 2.31 RELIEF VALVES 2.31.1 Periodic Inspections 2.31.2 Periodic Test |
65 | 2.31.3 Acceptance 2.31.4 References ITEM 2.32 CONTROL VALVE 2.32.1 Periodic Inspections 2.32.2 Periodic Test 2.32.3 Acceptance 2.32.4 References ITEM 2.33 TANKS 2.33.1 Periodic Inspections |
66 | 2.33.2 Periodic Test 2.33.3 Acceptance 2.33.4 References ITEM 2.34 FLEXIBLE HYDRAULIC HOSE AND FITTING ASSEMBLIES 2.34.1 Periodic Inspections 2.34.2 Periodic Test |
67 | 2.34.3 Acceptance Test 2.34.4 References ITEM 2.35 SUPPLY LINE AND SHUTOFF VALVE 2.35.1 Periodic Inspections 2.35.2 Periodic Test 2.35.3 Acceptance 2.35.4 References Table 2.34.3 Minimum Bend Radius for SAE 100R2 Hose |
68 | ITEM 2.36 HYDRAULIC CYLINDERS 2.36.1 Periodic Inspections 2.36.2 Periodic Test 2.36.3 Acceptance 2.36.4 References ITEM 2.37 PRESSURE SWITCH 2.37.1 Periodic Inspections 2.37.2 Periodic Test 2.37.3 Acceptance 2.37.4 References ITEM 2.38 ROPED WATER HYDRAULIC ELEVATORS 2.38.1 Periodic Inspections 2.38.2 Periodic Test: 3- Year Test ( for A17.1d– 2000 and Earlier Editions); Category 3 Test ( for A17.1– 2000/ B44- 00 and Later Editions) 2.38.3 Acceptance 2.38.4 References ITEM 2.39 LOW OIL PROTECTION 2.39.1 Periodic Inspections 2.39.2 Periodic Test |
69 | 2.39.3 Acceptance 2.39.4 References ITEM 2.40 MAINTENANCE RECORDS 2.40.1 Periodic Inspections 2.40.4 References ITEM 2.41 HYDRAULIC CONTROL 2.41.1 Periodic Inspections 2.41.2 Periodic Test 2.41.3 Acceptance 2.41.4 References ITEM 2.42 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 2.42.1 Periodic inspection 2.42.2 Periodic Test 2.42.3 Acceptance |
70 | 2.42.4 References |
71 | Part 3 Elevator — Top of Car ITEM 3.1 TOP- OF- CAR STOP SWITCH 3.1.1 Periodic Inspections 3.1.2 Periodic Test 3.1.3 Acceptance 3.1.4 References ITEM 3.2 CAR TOP LIGHT AND OUTLET 3.2.1 Periodic Inspections 3.2.2 Periodic Test 3.2.3 Acceptance 3.2.4 References ITEM 3.3 TOP- OF- CAR OPERATING DEVICE 3.3.1 Periodic Inspections 3.3.2 Acceptance 3.3.3 References |
72 | ITEM 3.4 TOP- OF- CAR CLEARANCE, REFUGE SPACE, AND STANDARD RAILING 3.4.1 Periodic Inspections 3.4.2 Periodic Test 3.4.3 Acceptance |
73 | 3.4.4 References ITEM 3.5 NORMAL TERMINAL STOPPING DEVICES 3.5.1 Periodic Inspections Fig. 3.4.1.2 Top Car Clearance and Runby ( A17.1– 1978 and Later Editions) |
74 | 3.5.2 Periodic Test 3.5.3 Acceptance 3.5.4 References ITEM 3.6 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES 3.6.1 Periodic Inspections |
75 | 3.6.2 Periodic Test 3.6.3 Acceptance 3.6.4 References ITEM 3.7 CAR LEVELING AND ANTICREEP DEVICES 3.7.1 Periodic Inspections |
76 | 3.7.2 Periodic Test 3.7.3 Acceptance 3.7.4 References ITEM 3.8 TOP EMERGENCY EXIT 3.8.1 Periodic Inspections 3.8.2 Periodic Test 3.8.3 Acceptance 3.8.4 References ITEM 3.9 FLOOR AND EMERGENCY IDENTIFICATION NUMBERING 3.9.1 Periodic Inspections 3.9.2 Periodic Test 3.9.3 Acceptance 3.9.4 References ITEM 3.10 HOISTWAY CONSTRUCTION 3.10.1 Periodic Inspections |
77 | 3.10.2 Periodic Test 3.10.3 Acceptance 3.10.4 References ITEM 3.11 HOISTWAY SMOKE CONTROL 3.11.1 Periodic Inspections 3.11.2 Periodic Test 3.11.3 Acceptance 3.11.4 References ITEM 3.12 PIPES, WIRING, AND DUCTS 3.12.1 Periodic Inspections 3.12.2 Periodic Test 3.12.3 Acceptance 3.12.4 References ITEM 3.13 WINDOWS, PROJECTIONS, RECESSES, AND SETBACKS 3.13.1 Periodic Inspections |
78 | 3.13.2 Periodic Test 3.13.3 Acceptance 3.13.4 References ITEM 3.14 HOISTWAY CLEARANCES 3.14.1 Periodic Inspections 3.14.2 Periodic Test 3.14.3 Acceptance 3.14.4 References ITEM 3.15 MULTIPLE HOISTWAYS 3.15.1 Periodic Inspections 3.15.2 Periodic Test 3.15.3 Acceptance 3.15.4 References ITEM 3.16 TRAVELING CABLES AND JUNCTION BOXES 3.16.1 Periodic Inspections |
79 | Table 3.14.3( a) Horizontal Clearances Table 3.14.3( b) Horizontal Distances |
80 | 3.16.2 Periodic Test 3.16.3 Acceptance 3.16.4 References ITEM 3.17 DOOR AND GATE EQUIPMENT 3.17.1 Periodic Inspections Fig. 3.16.1 Self- Tightening Grips |
82 | 3.17.2 Periodic Test 3.17.3 Acceptance 3.17.4 References ITEM 3.18 CAR FRAME AND STILES 3.18.1 Periodic Inspections 3.18.2 Periodic Test 3.18.3 Acceptance 3.18.4 References ITEM 3.19 GUIDE RAILS FASTENING AND EQUIPMENT 3.19.1 Periodic Inspections |
83 | 3.19.2 Periodic Test 3.19.3 Acceptance 3.19.4 References ITEM 3.20 GOVERNOR ROPE 3.20.1 Periodic Inspections 3.20.2 Periodic Test 3.20.3 Acceptance 3.20.4 References ITEM 3.21 GOVERNOR RELEASING CARRIER 3.21.1 Periodic Inspections 3.21.2 Periodic Test: 5- Year Test ( for A17.1d– 2000 and Earlier Editions); Category 5 Test ( for A17.1– 2000/ B44- 00 and Later Editions) 3.21.3 Acceptance 3.21.4 References |
84 | Fig. 3.22.1 Cross- Section Through Tapered Rope Socket Showing Maximum and Minimum Projection of Loops Above Embedment Medium ITEM 3.22 WIRE ROPE FASTENING AND HITCH PLATE 3.22.1 Periodic Inspections Table 3.22.1 Projection of Rope Strands Above Embedment Medium for 6- and 8- Strand Ropes |
85 | 3.22.2 Periodic Test 3.22.3 Acceptance 3.22.4 References ITEM 3.23 SUSPENSION ROPE 3.23.1 Periodic Inspections |
86 | Fig. 3.23.1 Types of Lay |
87 | Fig. 3.23.2 Cross Sections of Typical Wire Ropes |
88 | 3.23.2 Periodic Test 3.23.3 Acceptance 3.23.4 References ITEM 3.24 TOP COUNTERWEIGHT CLEARANCE 3.24.1 Periodic Inspections 3.24.2 Periodic Test 3.24.3 Acceptance 3.24.4 References |
89 | ITEM 3.25 CAR, OVERHEAD, AND DEFLECTOR SHEAVES 3.25.1 Periodic Inspections 3.25.2 Periodic Test 3.25.3 Acceptance 3.25.4 References ITEM 3.26 BROKEN ROPE, CHAIN, OR TAPE SWITCH 3.26.1 Periodic Inspections 3.26.2 Periodic Test 3.26.3 Acceptance 3.26.4 References ITEM 3.27 CROSSHEAD DATA PLATE AND ROPE DATA TAGS 3.27.1 Periodic Inspections 3.27.2 Periodic Test 3.27.3 Acceptance 3.27.4 References ITEM 3.28 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER 3.28.1 Periodic Inspections |
90 | 3.28.2 Periodic Test 3.28.3 Acceptance 3.28.4 References ITEM 3.29 COUNTERWEIGHT SAFETIES 3.29.1 Periodic Inspections 3.29.2 Periodic Test 3.29.3 Acceptance 3.29.4 References |
91 | ITEM 3.30 SPEED TEST 3.30.1 Periodic Inspections 3.30.2 Periodic Test 3.30.3 Acceptance 3.30.4 References ITEM 3.31 SLACK ROPE DEVICE — ROPED- HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS 3.31.1 Periodic Inspections 3.31.2 Periodic Test 3.31.3 Acceptance 3.31.4 References ITEM 3.32 TRAVELING SHEAVE — ROPED-HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS 3.32.1 Periodic Inspections |
92 | 3.32.2 Periodic Test 3.32.3 Acceptance 3.32.4 References ITEM 3.33 COMPENSATING ROPES AND CHAINS 3.33.1 Periodic Inspections 3.33.2 Periodic Test 3.33.3 Acceptance 3.33.4 References ITEM 3.34 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 3.34.1 Periodic Inspection 3.34.2 Periodic Test 3.34.3 Acceptance |
93 | 3.34.4 References |
94 | Part 4 Elevator — Outside Hoistway ITEM 4.1 CAR PLATFORM GUARD 4.1.1 Periodic Inspections 4.1.2 Periodic Test 4.1.3 Acceptance 4.1.4 References ITEM 4.2 HOISTWAY DOORS 4.2.1 Periodic Inspections |
95 | 4.2.2 Periodic Test 4.2.3 Acceptance 4.2.4 References ITEM 4.3 VISION PANELS 4.3.1 Periodic Inspections 4.3.2 Periodic Test 4.3.3 Acceptance 4.3.4 References ITEM 4.4 HOISTWAY DOOR LOCKING DEVICES 4.4.1 Periodic Inspections |
96 | 4.4.2 Periodic Test 4.4.3 Acceptance 4.4.4 References ITEM 4.5 ACCESS TO HOISTWAY 4.5.1 Periodic Inspections 4.5.2 Periodic Test 4.5.3 Acceptance 4.5.4 References ITEM 4.6 POWER CLOSING OF HOISTWAY DOORS 4.6.1 Periodic Inspections 4.6.2 Periodic Test 4.6.3 Acceptance 4.6.4 References |
97 | ITEM 4.7 SEQUENCE OPERATION 4.7.1 Periodic Inspections 4.7.2 Periodic Test 4.7.3 Acceptance 4.7.4 References ITEM 4.8 HOISTWAY ENCLOSURE 4.8.1 Periodic Inspections 4.8.2 Periodic Test 4.8.3 Acceptance 4.8.4 References ITEM 4.9 ELEVATOR PARKING DEVICES 4.9.1 Periodic Inspections 4.9.2 Periodic Test 4.9.3 Acceptance 4.9.4 References |
98 | ITEM 4.10 EMERGENCY DOORS IN BLIND HOISTWAYS 4.10.1 Periodic Inspections 4.10.2 Periodic Test 4.10.3 Acceptance 4.10.4 References ITEM 4.11 SEPARATE COUNTERWEIGHT HOISTWAY 4.11.1 Periodic Inspections 4.11.2 Periodic Test 4.11.3 References ITEM 4.12 STANDBY POWER SELECTION SWITCH 4.12.1 Periodic Inspections 4.12.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions) 4.12.3 Acceptance 4.12.4 References |
100 | Part 5 Elevator — Pit ITEM 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION 5.1.1 Periodic Inspections 5.1.2 Periodic Test 5.1.3 Acceptance |
101 | 5.1.4 References ITEM 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE 5.2.1 Periodic Inspections 5.2.2 Periodic Test 5.2.3 Acceptance |
102 | 5.2.4 References Fig. 5.2.3 Bottom Car Clearance Hydraulic Elevators |
103 | ITEM 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES 5.3.1 Periodic Inspections 5.3.2 Periodic Test 5.3.3 Acceptance 5.3.4 References ITEM 5.4 NORMAL TERMINAL STOPPING DEVICES 5.4.1 Periodic Inspections 5.4.2 Periodic Test 5.4.3 Acceptance 5.4.4 References ITEM 5.5 TRAVELING CABLES 5.5.1 Periodic Inspections 5.5.2 Periodic Test 5.5.3 Acceptance 5.5.4 References |
104 | ITEM 5.6 GOVERNOR- ROPE TENSION DEVICES 5.6.1 Periodic Inspections 5.6.2 Periodic Test 5.6.3 Acceptance 5.6.4 References ITEM 5.7 CAR FRAME AND PLATFORM 5.7.1 Periodic Inspections 5.7.2 Periodic Test 5.7.3 Acceptance 5.7.4 References ITEM 5.8 CAR AND COUNTERWEIGHT SAFETIES AND GUIDING MEMBERS — INCLUDING ROPED- HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS 5.8.1 Periodic Inspections |
105 | 5.8.2 Periodic Test 5.8.3 Acceptance 5.8.4 References |
106 | ITEM 5.9 BUFFER AND EMERGENCY TERMINAL SPEED LIMITING DEVICES 5.9.1 Periodic Inspections 5.9.2 Periodic Test |
107 | 5.9.3 Acceptance 5.9.4 References ITEM 5.10 COMPENSATING CHAINS, ROPES, AND SHEAVES 5.10.1 Periodic Inspections 5.10.2 Periodic Test 5.10.3 Acceptance 5.10.4 References |
108 | ITEM 5.11 PLUNGER AND CYLINDER 5.11.1 Periodic Inspections 5.11.2 Periodic Test 5.11.3 Acceptance 5.11.4 References ITEM 5.12 CAR BUFFER 5.12.1 Periodic Inspections 5.12.2 Periodic Test 5.12.3 Acceptance 5.12.4 References ITEM 5.13 GUIDING MEMBERS 5.13.1 Periodic Inspections 5.13.2 Periodic Test 5.13.3 Acceptance 5.13.4 References ITEM 5.14 SUPPLY PIPING 5.14.1 Periodic Inspections |
109 | 5.14.2 Periodic Test 5.14.3 Acceptance 5.14.4 References ITEM 5.15 OVERSPEED VALVE 5.15.1 Periodic Inspections 5.15.2 Category 5 Periodic Test 5.15.3 Acceptance 5.15.4 References ITEM 5.16 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 5.16.1 Periodic Inspections 5.16.2 Periodic Test |
110 | 5.16.3 Acceptance 5.16.4 References |
111 | Part 6 Elevator — Firefighters’ Service ITEM 6.1 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS ( A17.1b– 1973 THROUGH A17.1b– 1980) 6.1.1 Periodic Inspections 6.1.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions) |
112 | 6.1.3 Acceptance 6.1.4 References |
113 | ITEM 6.2 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS ( A17.1– 1981 THROUGH A17.1b– 1983) 6.2.1 Periodic Inspections 6.2.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions) |
114 | 6.2.3 Acceptance 6.2.4 References |
115 | ITEM 6.3 FIREFIGHTERS’ SERVICE ( A17.1– 1984 THROUGH A17.1a– 1988 and A17.3) 6.3.1 Periodic Inspections 6.3.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions) |
117 | 6.3.3 Acceptance 6.3.4 References ITEM 6.4 FIREFIGHTERS’ SERVICE ( A17.1b– 1989 THROUGH A17.1d– 2000) 6.4.1 Periodic Inspections 6.4.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions) |
118 | Fig. 6.4.2( b)( 9) Visual Signal |
119 | Fig. 6.4.2( g)( 1) Phase I Instructions |
120 | Fig. 6.4.2( g)( 2) Phase II Instructions ( A17.1b– 1989 Through A17.1b– 1995) Fig. 6.4.2( g)( 3) Phase II Instructions ( A17.1– 1996 Through A17.1d– 2000) |
121 | 6.4.3 Acceptance 6.4.4 References ITEM 6.5 ACCEPTANCE CHECKLIST FOR FIREFIGHTERS’ SERVICE ( ASME A17.1– 2000 and CSA B44- 00): AUTOMATIC ELEVATORS 6.5.1 Emergency Signaling Devices 6.5.2 Phase I Key Switch and Instructions 6.5.3 Phase II In- Car Switch and Instruction 6.5.4 Monthly Test 6.5.5 Phase I Operation While Running |
122 | 6.5.6 Phase I Operation With Doors Open 6.5.7 Emergency Stop Switch and/ or In- Car Stop Switch and Doors Closing 6.5.8 Stop Switches and Door Buttons 6.5.9 Fire Alarm- Initiating Device and Operation 6.5.10 Fire Alarm- Initiating Device and Phase I Switch 6.5.11 Phase II Key Switch and Sign |
123 | 6.5.12 Phase II Switch in ” HOLD” Position 6.5.13 Phase II Switch in ” OFF” Position and Doors Closing: Power- Operated Horizontally and Vertically Sliding Doors 6.5.14 Removal From Phase II 6.5.15 Power Disconnects Open 6.5.16 Top- of- Car Operating Device 6.5.17 Automatic Elevators With Attendant Operation 6.5.18 Elevators on Phase I and Phase II, Prevention of Operation and Disabling Not Allowed |
124 | Part 7 Escalator — External ITEM 7.1 GENERAL FIRE PROTECTION 7.1.1 Periodic Inspections 7.1.2 Periodic Test 7.1.3 Acceptance 7.1.4 References ITEM 7.2 GEOMETRY 7.2.1 Periodic Inspections 7.2.2 Periodic Test 7.2.3 Acceptance 7.2.4 References |
125 | Fig. 7.2.1( a) Dimensions for Existing Escalators ( for Escalators Installed Under A17.1– 1955 and A17.1– 1960 Editions) |
126 | Fig. 7.2.1( b) Dimensions for Existing Escalators ( for Escalators Installed Under A17.1– 1965 Through A17.1– 1981) |
127 | Fig. 7.2.1( c) Relationship of Escalator Parts ( A17.1a– 1982 and Later Editions) Fig. 7.2.3 Checking Incline |
128 | ITEM 7.3 HANDRAILS 7.3.1 Periodic Inspections 7.3.2 Periodic Test 7.3.3 Acceptance 7.3.4 References ITEM 7.4 ENTRANCE AND EGRESS ENDS 7.4.1 Periodic Inspections Fig. 7.4.1 Safety Zone |
129 | 7.4.2 Periodic Test 7.4.3 Acceptance 7.4.4 References ITEM 7.5 LIGHTING 7.5.1 Periodic Inspections 7.5.2 Periodic Test 7.5.3 Acceptance 7.5.4 References ITEM 7.6 CAUTION SIGNS 7.6.1 Periodic Inspections 7.6.2 Periodic Test 7.6.3 Acceptance 7.6.4 References ITEM 7.7 COMBPLATE AND COMB STEP IMPACT DEVICE 7.7.1 Periodic Inspections 7.7.2 Periodic Test |
130 | 7.7.3 Acceptance 7.7.4 References Fig. 7.7.1 Checking Step/ Combplate Mesh |
131 | ITEM 7.8 DECK BARRICADES AND ANTISLIDE DEVICES 7.8.1 Periodic Inspections 7.8.2 Periodic Test 7.8.3 Acceptance 7.8.4 References Fig. 7.7.3 Test of Combplate/ Landing Plate Assembly |
132 | Fig. 7.8.1( a) Deck Barricade Fig. 7.8.1( b) High Deck Balustrade Antislide Devices |
133 | ITEM 7.9 STEPS AND UPTHRUST DEVICE 7.9.1 Periodic Inspections Fig. 7.9.1( a) Smooth Riser |
134 | Fig. 7.9.1( b) Cleated Riser Fig. 7.9.1( c) Escalator Step Riser |
135 | 7.9.2 Periodic Test 7.9.3 Acceptance 7.9.4 References ITEM 7.10 OPERATING AND SAFETY DEVICES 7.10.1 Periodic Inspections Fig. 7.9.1( d) Escalator Step Tread [ A17.1– 1955 Through A17.1– 1990, Rule 802.5 ( Requirement 6.1.3.5)] |
136 | Fig. 7.9.3 Example of Two Flat Steps |
137 | 7.10.2 Periodic Test 7.10.3 Acceptance 7.10.4 References ITEM 7.11 SKIRT OBSTRUCTION DEVICE 7.11.1 Periodic Inspections 7.11.2 Periodic Test 7.11.3 Acceptance 7.11.4 References ITEM 7.12 ( RESERVED) ITEM 7.13 EGRESS RESTRICTION ( ROLLING SHUTTER) DEVICE 7.13.1 Periodic Inspections 7.13.2 Periodic Test 7.13.3 Acceptance 7.13.4 References ITEM 7.14 SPEED 7.14.1 Periodic Inspections |
138 | Fig. 7.11.1 Typical Skirt Obstruction Device |
139 | 7.14.2 Periodic Test 7.14.3 Acceptance 7.14.4 References ITEM 7.15 BALUSTRADES 7.15.1 Periodic Inspections 7.15.2 Periodic Test 7.15.3 Acceptance 7.15.4 References ITEM 7.16 CEILING INTERSECTION GUARDS 7.16.1 Periodic Inspections 7.16.2 Periodic Test 7.16.3 Acceptance 7.16.4 References ITEM 7.17 STEP/ SKIRT CLEARANCES, PANELS, AND PERFORMANCE INDEX 7.17.1 Periodic Inspections |
140 | Fig. 7.16.1 Ceiling or Soffit Guard [ Requirements 6.1.3.3.9 and 6.2.3.3.7 ( Rules 802.3g and 902.3g)] Fig. 7.17.1 Measuring Gap Between Step and Skirt |
141 | 7.17.2 Periodic Test Fig. 7.17.2 Angle of Skirt Panel |
142 | 7.17.3 Acceptance 7.17.4 References ITEM 7.18 OUTDOOR PROTECTION 7.18.1 Periodic Inspections 7.18.2 Periodic Test 7.18.3 Acceptance 7.18.4 References ITEM 7.19 MAINTENANCE RECORDS 7.19.1 Periodic Inspections |
143 | 7.19.2 Periodic Test 7.19.3 Acceptance 7.19.4 References ITEM 7.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 7.20.1 Periodic Inspections 7.20.2 Periodic Test 7.20.3 Acceptance 7.20.4 References |
144 | Fig. 7.18.3 Escalator Cover Overlap |
145 | Part 8 Escalator — Internal ITEM 8.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION 8.1.1 Periodic Inspections 8.1.2 Periodic Test 8.1.3 Acceptance 8.1.4 References ITEM 8.2 MACHINERY SPACE STOP SWITCHES AND INSPECTION CONTROL 8.2.1 Periodic Inspections 8.2.2 Periodic Test |
146 | 8.2.3 Acceptance 8.2.4 References ITEM 8.3 CONTROLLER AND WIRING 8.3.1 Periodic Inspections 8.3.2 Periodic Test 8.3.3 Acceptance 8.3.4 References ITEM 8.4 DRIVE MACHINE AND BRAKE 8.4.1 Periodic Inspections 8.4.2 Periodic Test |
147 | 8.4.3 Acceptance 8.4.4 References |
148 | ITEM 8.5 SPEED GOVERNOR 8.5.1 Periodic Inspections 8.5.2 Periodic Test 8.5.3 Acceptance 8.5.4 References ITEM 8.6 BROKEN DRIVE CHAIN AND DISCONNECTED MOTOR SAFETY DEVICE 8.6.1 Periodic Inspections 8.6.2 Periodic Test 8.6.3 Acceptance 8.6.4 References ITEM 8.7 REVERSAL STOP SWITCH 8.7.1 Periodic Inspections 8.7.2 Periodic Test |
149 | 8.7.3 Acceptance 8.7.4 References ITEM 8.8 BROKEN STEP CHAIN DEVICE 8.8.1 Periodic Inspections 8.8.2 Periodic Test 8.8.3 Acceptance 8.8.4 References ITEM 8.9 STEP UPTHRUST DEVICE 8.9.1 Periodic Inspections 8.9.2 Periodic Test 8.9.3 Acceptance 8.9.4 References ITEM 8.10 MISSING STEP DEVICE 8.10.1 Periodic Inspections 8.10.2 Periodic Test 8.10.3 Acceptance 8.10.4 References |
150 | ITEM 8.11 STEP LEVEL DEVICE 8.11.1 Periodic Inspections 8.11.2 Periodic Test 8.11.3 Acceptance 8.11.4 References ITEM 8.12 STEPS, STEP CHAINS, AND TRUSSES 8.12.1 Periodic Inspections 8.12.2 Periodic Test Fig. 8.9.2 Typical Step Upthrust Device |
151 | 8.12.3 Acceptance 8.12.4 References Fig. 8.12.2 Positioning of Steps for Inspection of Truss |
152 | ITEM 8.13 HANDRAIL SYSTEMS AND SAFETY DEVICES 8.13.1 Periodic Inspections 8.13.2 Periodic Test 8.13.3 Acceptance 8.13.4 References ITEM 8.14 CODE DATA PLATE 8.14.1 Periodic Inspections 8.14.2 Periodic Test 8.14.3 Acceptance 8.14.4 References ITEM 8.15 RESPONSE TO SMOKE DETECTORS 8.15.1 Periodic Inspections 8.15.2 Periodic Test 8.15.3 Acceptance 8.15.4 References |
153 | ITEM 8.16 STEP LATERAL DISPLACEMENT DEVICE 8.16.1 Periodic Inspections 8.16.2 Periodic Test 8.16.3 Acceptance 8.16.4 References ITEM 8.17 INSPECTION CONTROL 8.17.1 Periodic Inspections 8.17.2 Periodic Test 8.17.3 Acceptance 8.17.4 References ITEM 8.18 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 8.18.1 Periodic Inspection 8.18.2 Periodic Test 8.18.3 Acceptance 8.18.4 References |
154 | Part 9 Moving Walk — External ITEM 9.1 GENERAL FIRE PROTECTION 9.1.1 Periodic Inspections 9.1.2 Periodic Test 9.1.3 Acceptance 9.1.4 References ITEM 9.2 GEOMETRY 9.2.1 Periodic Inspections 9.2.2 Periodic Test 9.2.3 Acceptance 9.2.4 References ITEM 9.3 HANDRAILS 9.3.1 Periodic Inspections |
155 | 9.3.2 Periodic Test Fig. 9.2.1( a) Moving Walk Geometry ( for Moving Walks Installed Under A17.1– 1965 Through A17.1b– 1980) |
156 | Fig. 9.2.1( b) Moving Walk Geometry ( for Moving Walks Installed Under A17.1– 1981 Through A17.1a– 1991) Fig. 9.2.3 Maximum Treadway Angle |
157 | 9.3.3 Acceptance 9.3.4 References ITEM 9.4 ENTRANCE AND EGRESS ENDS 9.4.1 Periodic Inspections 9.4.2 Periodic Test 9.4.3 Acceptance 9.4.4 References ITEM 9.5 LIGHTING 9.5.1 Periodic Inspections Table 9.2.3( a) Treadway Width ( A17.1– 1965 Through A17.1d– 1970) Table 9.2.3( b) Treadway Width ( A17.1– 1971 and Later Editions) Table 9.2.3( c) Minimum Treadway Width |
158 | 9.5.2 Periodic Test 9.5.3 Acceptance 9.5.4 References ITEM 9.6 CAUTION SIGNS 9.6.1 Periodic Inspections 9.6.2 Periodic Test 9.6.3 Acceptance 9.6.4 References ITEM 9.7 COMBPLATE AND COMB STEP IMPACT DEVICE 9.7.1 Periodic Inspections 9.7.2 Periodic Test Fig. 9.3.3 Moving Walk Handrail Extension ( A17.1– 1971 and Later Editions) |
159 | 9.7.3 Acceptance 9.7.4 References ITEM 9.8 DECK BARRICADES 9.8.1 Periodic Inspections 9.8.2 Periodic Test 9.8.3 Acceptance 9.8.4 References ITEM 9.9 TREADWAYS 9.9.1 Periodic Inspections |
160 | 9.9.2 Periodic Test 9.9.3 Acceptance 9.9.4 References ITEM 9.10 OPERATING AND SAFETY DEVICES 9.10.1 Periodic Inspections Fig. 9.9.1 Moving Walk Treadway Slots |
161 | 9.10.2 Periodic Test 9.10.3 Acceptance 9.10.4 References ITEM 9.11 ( RESERVED) ITEM 9.12 ( RESERVED) ITEM 9.13 EGRESS RESTRICTION ( ROLLING SHUTTER) DEVICE 9.13.1 Periodic Inspections 9.13.2 Periodic Test 9.13.3 Acceptance 9.13.4 References ITEM 9.14 SPEED 9.14.1 Periodic Inspections Table 9.14.1( a) Treadway Speed ( A17.1– 1981 and Later Editions) |
162 | 9.14.2 Periodic Test 9.14.3 Acceptance 9.14.4 References ITEM 9.15 BALUSTRADES 9.15.1 Periodic Inspections 9.15.2 Periodic Test 9.15.3 Acceptance 9.15.4 References ITEM 9.16 CEILING INTERSECTION GUARDS 9.16.1 Periodic Inspections Table 9.14.1( b) Treadway Speed ( A17.1– 1965 Through A17.1b– 1980) Table 9.14.1( c) Treadway Speed ( A17.1– 1965 Through A17.1b– 1980) |
163 | Fig. 9.17.1 Treadway Clearances 9.16.2 Periodic Test 9.16.3 Acceptance 9.16.4 References ITEM 9.17 SKIRT PANELS 9.17.1 Periodic Inspections |
164 | 9.17.2 Periodic Test 9.17.3 Acceptance 9.17.4 References ITEM 9.18 OUTDOOR PROTECTION 9.18.1 Periodic Inspections 9.18.2 Periodic Test 9.18.3 Acceptance 9.18.4 References ITEM 9.19 MAINTENANCE RECORDS 9.19.1 Periodic Inspections 9.19.2 Periodic Test 9.19.3 Acceptance 9.19.4 References ITEM 9.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 9.20.1 Periodic Inspections 9.20.2 Periodic Test 9.20.3 Acceptance |
165 | 9.20.4 References |
166 | Part 10 Moving Walk — Internal ITEM 10.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION 10.1.1 Periodic Inspections 10.1.2 Periodic Test 10.1.3 Acceptance 10.1.4 References ITEM 10.2 STOP SWITCH AND INSPECTION CONTROL 10.2.1 Periodic Inspections 10.2.2 Periodic Test 10.2.3 Acceptance |
167 | 10.2.4 References ITEM 10.3 CONTROLLER AND WIRING 10.3.1 Periodic Inspections 10.3.2 Periodic Test 10.3.3 Acceptance 10.3.4 References ITEM 10.4 DRIVE MACHINE AND BRAKE 10.4.1 Periodic Inspections 10.4.2 Periodic Test |
168 | 10.4.3 Acceptance 10.4.4 References ITEM 10.5 SPEED GOVERNOR 10.5.1 Periodic Inspections 10.5.2 Periodic Test |
169 | 10.5.3 Acceptance 10.5.4 References ITEM 10.6 BROKEN DRIVE CHAIN AND DISCONNECTED MOTOR SAFETY DEVICE 10.6.1 Periodic Inspections 10.6.2 Periodic Test 10.6.3 Acceptance 10.6.4 References ITEM 10.7 REVERSAL STOP SWITCH 10.7.1 Periodic Inspections 10.7.2 Periodic Test |
170 | 10.7.3 Acceptance 10.7.4 References ITEM 10.8 BROKEN TREADWAY DEVICE 10.8.1 Periodic Inspections 10.8.2 Periodic Test 10.8.3 Acceptance 10.8.4 References ITEM 10.9 ( RESERVED) ITEM 10.10 MISSING PALLET DEVICE 10.10.1 Periodic Inspections 10.10.2 Periodic Test 10.10.3 Acceptance 10.10.4 References ITEM 10.11 PALLET LEVEL DEVICE 10.11.1 Periodic Inspections 10.11.2 Periodic Test |
171 | 10.11.3 Acceptance 10.11.4 References ITEM 10.12 PALLETS, PALLET CHAINS, AND TRUSSES 10.12.1 Periodic Inspections 10.12.2 Periodic Test 10.12.3 Acceptance 10.12.4 References |
172 | ITEM 10.13 HANDRAIL SYSTEMS AND SAFETY DEVICES 10.13.1 Periodic Inspections 10.13.2 Periodic Test 10.13.3 Acceptance 10.13.4 References ITEM 10.14 CODE DATA PLATE 10.14.1 Periodic Inspections 10.14.2 Periodic Test 10.14.3 Acceptance 10.14.4 References ITEM 10.15 RESPONSE TO SMOKE DETECTORS 10.15.1 Periodic Inspections 10.15.2 Periodic Test |
173 | 10.15.3 Acceptance 10.15.4 References ITEM 10.16 INSPECTION CONTROL 10.16.1 Periodic Inspections 10.16.2 Periodic Test 10.16.3 Acceptance 10.16.4 References ITEM 10.17 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER) 10.17.1 Periodic Inspections 10.17.2 Periodic Test 10.17.3 Acceptance 10.17.4 References |
174 | Part 11 Elevator — Machine- Room- Less ( MRL) ITEM 11.1 ACCESS TO MACHINE ROOM/ MACHINERY SPACE/ CONTROL ROOM/ CONTROL SPACE 11.1.1 Periodic Inspections 11.1.2 Periodic Test 11.1.3 Acceptance 11.1.4 References ITEM 11.2 ACCESS DOOR AND OPENINGS 11.2.1 Periodic Inspections 11.2.2 Periodic Test 11.2.3 Acceptance 11.2.4 References ITEM 11.3 ENCLOSURE OF ROOMS AND SPACES 11.3.1 Periodic Inspections 11.3.2 Periodic Test 11.3.3 Acceptance |
175 | 11.3.4 References ITEM 11.4 MAINTENANCE PATH AND CLEARANCE 11.4.1 Periodic Inspections 11.4.2 Periodic Test 11.4.3 Acceptance 11.4.4 References ITEM 11.5 MACHINE/ CONTROL ROOMS CONTAINING OVERHEAD DRIVE MACHINES 11.5.1 Periodic Inspections 11.5.2 Periodic Test 11.5.3 Acceptance 11.5.4 References ITEM 11.6 TEMPERATURE/ HUMIDITY 11.6.1 Periodic Inspections 11.6.2 Periodic Test 11.6.3 Acceptance 11.6.4 References ITEM 11.7 DISCONNECTING MEANS 11.7.1 Periodic Inspections 11.7.2 Periodic Test 11.7.3 Acceptance 11.7.4 References ITEM 11.8 REMOTE MACHINE ROOMS AND CONTROL ROOMS 11.8.1 Periodic Inspections 11.8.2 Periodic Test 11.8.3 Acceptance 11.8.4 References |
176 | ITEM 11.9 INSPECTION AND TEST PANELS 11.9.1 Periodic Inspections 11.9.2 Periodic Test 11.9.3 Acceptance 11.9.4 References ITEM 11.10 GOVERNOR, OVERSPEED SWITCH 11.10.1 Periodic Inspections 11.10.2 Periodic Test 11.10.3 Acceptance 11.10.4 References ITEM 11.11 EMERGENCY BRAKE 11.11.1 Periodic Inspections 11.11.2 Periodic Test 11.11.3 Acceptance |
177 | 11.11.4 References ITEM 11.12 TRACTION SHEAVES 11.12.1 Periodic Inspections 11.12.2 Periodic Test 11.12.3 Acceptance 11.12.4 References ITEM 11.13 SECONDARY AND DEFLECTOR SHEAVES 11.13.1 Periodic Inspections 11.13.2 Periodic Test 11.13.3 Acceptance 11.13.4 References ITEM 11.14 TERMINAL STOPPING DEVICES 11.14.1 Periodic Inspections 11.14.2 Periodic Test 11.14.3 Acceptance 11.14.4 References ITEM 11.15 WORKING AREAS INSIDE THE HOISTWAY AND IN THE PIT 11.15.1 Periodic Inspections 11.15.2 Periodic Test 11.15.3 Acceptance |
178 | 11.15.4 References ITEM 11.16 LOCATION OF MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, CONTROL ROOMS, AND EQUIPMENT 11.16.1 Periodic Inspections 11.16.2 Periodic Test 11.16.3 Acceptance 11.16.4 References ITEM 11.17 HYDRAULIC ELEVATORS — SHUTOFF/ MANUAL LOWERING VALVES 11.17.1 Periodic Inspections 11.17.2 Periodic Test 11.17.3 Acceptance 11.17.4 References ITEM 11.18 HYDRAULIC ELEVATORS — PRESSURE GAGE FITTINGS 11.18.1 Periodic Inspections 11.18.2 Periodic Test 11.18.3 Acceptance 11.18.4 References ITEM 11.19 HYDRAULIC ELEVATORS — ATMOSPHERE STORAGE AND DISCHARGE TANKS 11.19.1 Periodic Inspections 11.19.2 Periodic Test 11.19.3 Acceptance |
179 | 11.19.4 References ITEM 11.20 HYDRAULIC ELEVATORS — PRESSURE PIPING 11.20.1 Periodic Inspections 11.20.2 Periodic Test 11.20.3 Acceptance 11.20.4 References ITEM 11.21 EXPLANATORY FIGURES FOR DEFINITIONS OF ELEVATOR MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, CONTROL ROOM, REMOTE MACHINE ROOM, OR REMOTE CONTROL ROOM ITEM 11.22 INSPECTION OPERATION AND HOISTWAY ACCESS SWITCH OPERATION HIERARCHY Fig. 11.21- 1 Configuration A Fig. 11.21- 2 Configuration B Fig. 11.21- 3 Configuration C |
180 | Fig. 11.21- 4 Configuration D Fig. 11.21- 5 Configuration E |
181 | Fig. 11.21- 6 Configuration F Table 11.21 Definitions of Elevator Machinery Space, Machine Room, Control Space, Control Room, Remote Machine Room, or Remote Control Room |
182 | Table 11.22 Inspection Operation and Hoistway Access Switch Operation Hierarchy |
183 | MANDATORY APPENDIX I GUIDE FOR INSPECTION OF INCLINED ELEVATORS FOREWORD PREFACE Part I- 1 Elevator — Inside of Car ITEM I- 1.6 CAR EMERGENCY SIGNAL ITEM I- 1.10 POWER OPENING OF DOORS |
184 | ITEM I- 1.11 CAR VISION PANELS AND CAR DOORS ITEM I- 1.13 EMERGENCY EXIT ITEM I- 1.16 RATED LOAD, PLATFORM AREA, AND DATA PLATE ITEM I- 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS |
185 | Part I- 2 Inclined Elevators — Machine Room ITEM I- 2.13 GOVERNOR, OVERSPEED SWITCH, AND SEAL ITEM I- 2.20 WINDING DRUM MACHINE AND SLACK CABLE DEVICES ITEM I- 2.28 TERMINAL STOPPING DEVICES ITEM I- 2.29 CAR AND COUNTERWEIGHT SAFETIES |
186 | Part I- 3 Elevator — Top Car/ Uphill Emergency Exit/ End- Loading Top Car Door ITEM I- 3.1 TOP- OF- CAR STOP SWITCH |
187 | ITEM I- 3.2 CAR TOP/ INSPECTION LOCATION LIGHT AND OUTLET ITEM I- 3.3 TOP- OF- CAR EXTERIOR OPERATING DEVICE ITEM I- 3.4 TOP- OF- CAR/ UPHILL- OF- CAR CLEARANCE AND REFUGE SPACE ITEM I- 3.5 NORMAL TERMINAL STOPPING DEVICES ITEM I- 3.6 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES ITEM I- 3.8 TOP/ UPHILL END EMERGENCY EXIT ITEM I- 3.10 HOISTWAY CONSTRUCTION |
188 | ITEM I- 3.16 TRAVELING CABLES, JUNCTION BOXES, AND PROTECTIVE MEANS ITEM I- 3.18 CAR FRAME ( CHASSIS) ITEM I- 3.19 GUIDE RAILS FASTENING AND EQUIPMENT ITEM I- 3.20 GOVERNOR ROPE ITEM I- 3.23 SUSPENSION ROPE |
189 | Part I- 4 Elevator — Outside Hoistway ITEM I- 4.1 CAR PLATFORM GUARD ITEM I- 3.27 CROSSHEAD/ UPHILL CHASSIS MEMBER DATA PLATE ITEM I- 4.5 ACCESS TO HOISTWAY ITEM I- 4.8 HOISTWAY ENCLOSURE |
190 | Part I- 5 Elevator Pit ITEM I- 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION ITEM I- 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE ITEM I- 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES |
191 | ITEM I- 5.4 NORMAL TERMINAL STOPPING DEVICES AND RETRACTABLE SILLS ITEM I- 5.5 TRAVELING CABLES ITEM I- 5.8 CAR SAFETIES AND GUIDING MEMBERS Part I- 6 Elevator — Firefighters’ Service ITEM I- 5.9 BUFFER AND EMERGENCY TERMINAL SPEED LIMITING DEVICES |
192 | Fig. I- 1.16.3 Net Platform Area Measurements Fig. I- 2.13.2- 1 Static Governor Rope Drive Fig. I- 2.13.2- 2 Wheel Driven Governor |
193 | Fig. I- 2.28.2 Retractable Sill Fig. I- 3.4 Uphill Clearance |
194 | Fig. I- 4.1 Car Platform Guard Fig. I- 5.1 Pits and Work Spaces |
195 | Fig. I- 5.2 Refuge Space When Conformance to Requirement 2.4.1 is Not Provided |
196 | Additional Checklist for Inclined Elevators |
197 | Additional Checklist for Inclined Elevators ( Cont’d) |
198 | MANDATORY APPENDIX II GUIDE FOR INSPECTION OF PRIVATE RESIDENCE ELECTRIC AND HYDRAULIC ELEVATORS FOREWORD PREFACE Part II- 1 Inside of Car ITEM II- 1.1 DOOR- REOPENING DEVICE II- 1.1.1 Acceptance |
199 | II- 1.1.2 References ITEM II- 1.2 STOP SWITCHES II- 1.2.1 Acceptance II- 1.2.2 References ITEM II- 1.3 OPERATING CONTROL DEVICES II- 1.3.1 Acceptance II- 1.3.2 References ITEM II- 1.4 SILLS AND CAR FLOOR II- 1.4.1 Acceptance II- 1.4.2 References ITEM II- 1.5 CAR LIGHTING II- 1.5.1 Acceptance II- 1.5.2 References ITEM II- 1.6 CAR EMERGENCY SIGNAL II- 1.6.1 Acceptance II- 1.6.2 References ITEM II- 1.7 CAR DOOR OR GATE II- 1.7.1 Acceptance |
200 | II- 1.7.2 References ITEM II- 1.8 DOOR CLOSING FORCE II- 1.8.1 Acceptance II- 1.8.2 References ITEM II- 1.9 POWER CLOSING OF DOORS OR GATES II- 1.9.1 Acceptance II- 1.9.2 References ITEM II- 1.10 POWER OPENING OF DOORS OR GATES II- 1.10.1 Acceptance II- 1.10.2 References ITEM II- 1.11 CAR VISION PANELS AND GLASS CAR DOORS ITEM II- 1.12 CAR ENCLOSURE II- 1.12.1 Acceptance II- 1.12.2 References ITEM II- 1.13 ACCESS PANELS II- 1.13.1 Acceptance |
201 | II- 1.13.2 References ITEM II- 1.14 VENTILATION ITEM II- 1.15 SIGNS AND OPERATING DEVICE SYMBOLS ITEM II- 1.16 RATED LOAD, PLATFORM AREA, AND DATA CAPACITY PLATE II- 1.16.1 Acceptance II- 1.16.2 References ITEM II- 1.17 STANDBY POWER OPERATION ITEM II- 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS ITEM II- 1.19 CAR RIDE II- 1.19.1 Acceptance II- 1.19.2 References |
202 | Part II- 2 Machine Room or Space ITEM II- 2.1 ACCESS TO EQUIPMENT SPACE II- 2.1.1 Acceptance II- 2.1.2 References ITEM II- 2.2 HEADROOM II- 2.2.1 Acceptance II- 2.2.2 References ITEM II- 2.3 LIGHTING AND RECEPTACLES II- 2.3.1 Acceptance II- 2.3.2 References ITEM II- 2.4 MACHINE SPACE II- 2.4.1 Acceptance II- 2.4.2 References ITEM II- 2.5 HOUSEKEEPING II- 2.5.1 Acceptance II- 2.5.2 References ITEM II- 2.6 VENTILATION ITEM II- 2.7 FIRE EXTINGUISHER ITEM II- 2.8 PIPES, WIRING, AND DUCTS II- 2.8.1 Acceptance |
203 | II- 2.8.2 References ITEM II- 2.9 GUARDING OF SUSPENSION MEANS II- 2.9.1 Acceptance II- 2.9.2 References ITEM II- 2.10 NUMBERING OF ELEVATORS, MACHINES, AND DISCONNNECT SWITCHES ITEM II- 2.11 DISCONNECTING MEANS AND CONTROL II- 2.11.1 Acceptance II- 2.11.2 References ITEM II- 2.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC. II- 2.12.1 Acceptance II- 2.12.2 References ITEM II- 2.13 GOVERNOR II- 2.13.1 Acceptance II- 2.13.2 References ITEM II- 2.14 DATA PLATE II- 2.14.1 Acceptance II- 2.14.2 References |
204 | ITEM II- 2.15 STATIC CONTROL ITEM II- 2.16 OVERHEAD BEAM AND FASTENINGS II- 2.16.1 Acceptance II- 2.16.2 References ITEM II- 2.17 DRIVE MACHINE BRAKE II- 2.17.1 Acceptance II- 2.17.2 References ITEM II- 2.18 TRACTION DRIVE MACHINES II- 2.18.1 Acceptance II- 2.18.2 References ITEM II- 2.19 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS II- 2.19.1 Acceptance II- 2.19.2 References ITEM II- 2.20 WINDING DRUM MACHINE AND SLACK CABLE DEVICE II- 2.20.1 Acceptance II- 2.20.2 References ITEM II- 2.21 CHAIN DRIVE MACHINE AND DRIVE SPROCKETS II- 2.21.1 Acceptance |
205 | II- 2.21.2 References ITEM II- 2.22 MOTOR GENERATOR ITEM II- 2.23 ABSORPTION OF REGENERATED POWER ITEM II- 2.24 AC DRIVES FROM A DC SOURCE ITEM II- 2.25 TRACTION SHEAVES II- 2.25.1 Acceptance II- 2.25.2 References ITEM II- 2.26 SECONDARY AND DEFLECTOR SHEAVES OR SPROCKETS II- 2.26.1 Acceptance II- 2.26.2 References ITEM II- 2.27 ROPE FASTENINGS II- 2.27.1 Acceptance II- 2.27.2 References ITEM II- 2.28 TERMINAL STOPPING DEVICES II- 2.28.1 Acceptance II- 2.28.2 References ITEM II- 2.29 CAR AND COUNTERWEIGHT SAFETIES II- 2.29.1 Acceptance |
206 | II- 2.29.2 References ITEM II- 2.30 HYDRAULIC POWER UNIT II- 2.30.1 Acceptance II- 2.30.2 References ITEM II- 2.31 RELIEF VALVES II- 2.31.1 Acceptance II- 2.31.2 References ITEM II- 2.32 CONTROL VALVE II- 2.32.1 Acceptance II- 2.32.2 References ITEM II- 2.33 TANKS II- 2.33.1 Acceptance II- 2.33.2 References ITEM II- 2.34 FLEXIBLE HYDRAULIC HOSE AND FITTING ASSEMBLIES II- 2.34.1 Acceptance |
207 | II- 2.34.2 References ITEM II- 2.35 SUPPLY LINE AND SHUTOFF VALVE II- 2.35.1 Acceptance II- 2.35.2 References ITEM II- 2.36 HYDRAULIC CYLINDERS II- 2.36.1 Acceptance II- 2.36.2 References ITEM II- 2.37 PRESSURE SWITCH II- 2.37.1 Acceptance II- 2.37.2 References ITEM II- 2.38 ROPED WATER HYDRAULIC ELEVATORS ITEM II- 2.39 MANUAL OPERATION II- 2.39.1 Acceptance II- 2.39.2 References ITEM II- 2.40 SLACK ROPE OR SLACK CHAIN DEVICES II- 2.40.1 Acceptance II- 2.40.2 References |
208 | Part II- 3 Top of Car ITEM II- 3.1 TOP- OF- CAR STOP SWITCH II- 3.1.1 Acceptance II- 3.1.2 References ITEM II- 3.2 CAR TOP LIGHT AND OUTLET ITEM II- 3.3 TOP- OF- CAR OPERATING DEVICE II- 3.3.1 Acceptance II- 3.3.2 References ITEM II- 3.4 TOP- OF- CAR CLEARANCE AND REFUGE SPACE II- 3.4.1 Acceptance II- 3.4.2 References ITEM II- 3.5 NORMAL TERMINAL STOPPING DEVICE II- 3.5.1 Acceptance II- 3.5.2 References ITEM II- 3.6 FINAL TERMINAL STOPPING DEVICES II- 3.6.1 Acceptance |
209 | II- 3.6.2 References ITEM II- 3.7 CAR LEVELING AND ANTICREEP DEVICES II- 3.7.1 Acceptance II- 3.7.2 References ITEM II- 3.8 TOP EMERGENCY EXIT ITEM II- 3.9 FLOOR AND EMERGENCY IDENTIFICATION NUMBERING ITEM II- 3.10 HOISTWAY CONSTRUCTION II- 3.10.1 Acceptance II- 3.10.2 References ITEM II- 3.11 HOISTWAY SMOKE CONTROL ITEM II- 3.12 PIPES WIRING AND DUCTS II- 3.12.1 Acceptance II- 3.12.2 References ITEM II- 3.13 WINDOWS PROJECTIONS, RECESSES, AND SETBACKS II- 3.13.1 Acceptance II- 3.13.2 References ITEM II- 3.14 HOISTWAY CLEARANCE II- 3.14.1 Acceptance II- 3.14.2 References ITEM II- 3.15 MULTIPLE HOISTWAYS ITEM II- 3.16 TRAVELING CABLES AND JUNCTION BOXES II- 3.16.1 Acceptance II- 3.16.2 References ITEM II- 3.17 DOOR AND GATE EQUIPMENT II- 3.17.1 Acceptance II- 3.17.2 References |
210 | ITEM II- 3.18 CAR FRAME AND STILES II- 3.18.1 Acceptance II- 3.18.2 References ITEM II- 3.19 GUIDE RAIL FASTENING AND EQUIPMENT II- 3.19.1 Acceptance II- 3.19.2 References ITEM II- 3.20 GOVERNOR ROPE II- 3.20.1 Acceptance II- 3.20.2 References ITEM II- 3.21 GOVERNOR- RELEASING CARRIER ITEM II- 3.22 WIRE ROPE OR CHAIN FASTENING AND HITCH PLATE II- 3.22.1 Acceptance II- 3.22.2 References ITEM II- 3.23 SUSPENSION ROPE OR CHAIN II- 3.23.1 Acceptance II- 3.23.2 References ITEM II- 3.24 TOP COUNTERWEIGHT CLEARANCE ITEM II- 3.25 CAR, OVERHEAD, AND DEFLECTOR SHEAVES II- 3.25.1 Acceptance II- 3.25.2 References ITEM II- 3.26 BROKEN ROPE, CHAIN, OR TAPE SELECTOR SWITCH ITEM II- 3.27 DATA PLATE II- 3.27.1 Acceptance II- 3.27.2 References ITEM II- 3.28 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER II- 3.28.1 Acceptance II- 3.28.2 References |
211 | ITEM II- 3.29 COUNTERWEIGHT SAFETIES II- 3.29.1 Acceptance II- 3.29.2 References ITEM II- 3.30 SPEED TEST II- 3.30.1 Acceptance II- 3.30.2 References Part II- 4 Outside Hoistway ITEM II- 4.1 CAR PLATFORM GUARD II- 4.1.1 Acceptance II- 4.1.2 References ITEM II- 4.2 HOISTWAY DOORS II- 4.2.1 Acceptance ITEM II- 3.31 SLACK ROPE OR SLACK CHAIN DEVICE II- 3.31.1 Acceptance II- 3.31.2 References ITEM II- 3.32 TRAVELING SHEAVE ITEM II- 3.33 COMPENSATING ROPES OR CHAINS II- 4.2.2 References ITEM II- 4.3 VISION PANELS ITEM II- 4.4 HOISTWAY DOOR- LOCKING DEVICES II- 4.4.1 Acceptance |
212 | II- 4.4.2 References ITEM II- 4.5 ACCESS TO HOISTWAY II- 4.5.1 Acceptance II- 4.5.2 References ITEM II- 4.6 POWER CLOSING OF HOISTWAY DOORS II- 4.6.1 Acceptance II- 4.6.2 References ITEM II- 4.7 SEQUENCE OPERATION ITEM II- 4.8 HOISTWAY ENCLOSURE II- 4.8.1 Acceptance II- 4.8.2 References ITEM II- 4.9 ELEVATOR PARKING DEVICES ITEM II- 4.10 EMERGENCY DOORS IN BLIND HOISTWAYS ITEM II- 4.11 SEPARATE COUNTERWEIGHT HOISTWAY II- 4.11.1 Acceptance II- 4.11.2 References ITEM II- 4.12 STANDBY POWER SELECTION SWITCH |
213 | Part II- 5 Pit ITEM II- 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION II- 5.1.1 Acceptance II- 5.1.2 References ITEM II- 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE ITEM II- 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES ITEM II- 5.4 NORMAL TERMINAL STOPPING DEVICES ITEM II- 5.5 TRAVELING CABLES II- 5.5.1 Acceptance II- 5.5.2 References ITEM II- 5.6 GOVERNOR ROPE- TENSIONING DEVICE II- 5.6.1 Acceptance II- 5.6.2 References ITEM II- 5.7 CAR FRAME AND PLATFORM ITEM II- 5.8 CAR SAFETIES AND GUIDING MEMBERS II- 5.8.1 Acceptance II- 5.8.2 References ITEM II- 5.9 BUFFER II- 5.9.1 Acceptance II- 5.9.2 References ITEM II- 5.10 COMPENSATING CHAINS, ROPES, AND SHEAVES ITEM II- 5.11 PLUNGER AND CYLINDER II- 5.11.1 Acceptance II- 5.11.2 References |
214 | ITEM II- 5.12 CAR BUFFER ITEM II- 5.13 GUIDING MEMBERS II- 5.13.1 Acceptance II- 5.13.2 References ITEM II- 5.14 SUPPLY PIPING II- 5.14.1 Acceptance II- 5.14.2 References ITEM II- 5.15 OVERSPEED VALVE II- 5.15.1 Acceptance II- 5.15.2 References |
215 | MANDATORY APPENDIX III GUIDE FOR INSPECTION OF PRIVATE RESIDENCE INCLINED ELEVATORS FOREWORD PREFACE Part III- 1 Inside of Car ITEM III- 1.1 DOOR- REOPENING DEVICE III- 1.1.4 References ITEM III- 1.2 STOP SWITCHES III- 1.2.4 References |
216 | ITEM III- 1.3 OPERATING CONTROL DEVICES III- 1.3.3 Acceptance III- 1.3.4 References ITEM III- 1.4 SILLS AND CAR FLOOR ITEM III- 1.5 CAR LIGHTING ITEM III- 1.6 CAR DOOR OR GATE III- 1.6.3 Acceptance III- 1.6.4 References ITEM III- 1.7 CAR ENCLOSURE III- 1.7.3 Acceptance III- 1.7.4 References ITEM III- 1.8 RATED LOAD, PLATFORM AREA, AND DATA PLATE III- 1.8.3 Acceptance III- 1.8.4 References ITEM III- 1.9 CAR RIDE III- 1.9.3 Acceptance III- 1.9.4 References |
217 | Part III- 2 Machine Room Part III- 3 Top of Car Part III- 4 Outside Hoistway ITEM III- 4.1 NORMAL TERMINAL STOPPING DEVICES III- 4.1.3 Acceptance III- 4.1.4 References ITEM III- 4.2 FINAL TERMINAL STOPPING DEVICES III- 4.2.3 Acceptance III- 4.2.4 References ITEM III- 4.3 HOISTWAY CONSTRUCTION III- 4.3.3 Acceptance III- 4.3.4 References ITEM III- 4.4 HOISTWAY CLEARANCES III- 4.4.3 Acceptance III- 4.4.4 References |
218 | ITEM III- 4.5 CAR FRAMES AND CHASSIS III- 4.5.3 Acceptance III- 4.5.4 References ITEM III- 4.6 GUIDE RAILS FASTENING AND EQUIPMENT III- 4.6.3 Acceptance III- 4.6.4 References ITEM III- 4.7 WIRE ROPE AND FASTENING III- 4.7.3 Acceptance III- 4.7.4 References ITEM III- 4.8 CAR, TRAVELING, AND DEFLECTOR SHEAVES III- 4.8.3 Acceptance III- 4.8.4 References ITEM III- 4.9 COUNTERWEIGHT III- 4.9.3 Acceptance III- 4.9.4 References ITEM III- 4.10 HOISTWAY DOORS OR GATES III- 4.10.3 Acceptance III- 4.10.4 References ITEM III- 4.11 HOISTWAY DOOR- OR GATE- LOCKING DEVICES III- 4.11.3 Acceptance III- 4.11.4 References |
219 | NONMANDATORY APPENDIX A INSPECTION CHECKLISTS Checklist for Electric Elevators |
220 | Checklist for Electric Elevators ( Cont’d) |
221 | Checklist for Electric Elevators ( Cont’d) |
222 | Checklist for Electric Elevators ( Cont’d) |
223 | Checklist for Electric Elevators ( Cont’d) |
224 | Checklist for Electric Elevators ( Cont’d) |
225 | Checklist for Electric Elevators ( Cont’d) |
226 | Checklist for Electric Elevators ( Cont’d) |
227 | Checklist for Electric Elevators ( Cont’d) |
228 | Checklist for Electric Elevators ( Cont’d) |
229 | Checklist for Hydraulic Elevators |
230 | Checklist for Hydraulic Elevators ( Cont’d) |
231 | Checklist for Hydraulic Elevators ( Cont’d) |
232 | Checklist for Hydraulic Elevators ( Cont’d) |
233 | Checklist for Hydraulic Elevators ( Cont’d) |
234 | Checklist for Hydraulic Elevators ( Cont’d) |
235 | Checklist for Hydraulic Elevators ( Cont’d) |
236 | Checklist for Hydraulic Elevators ( Cont’d) |
237 | Checklist for Hydraulic Elevators ( Cont’d) |
238 | Checklist for Hydraulic Elevators ( Cont’d) |
239 | Checklist for Escalators |
240 | Checklist for Escalators ( Cont’d) |
241 | Checklist for Escalators ( Cont’d) |
242 | Checklist for Moving Walks |
243 | Checklist for Moving Walks ( Cont’d) |
244 | Checklist for Moving Walks ( Cont’d) |
245 | NONMANDATORY APPENDIX B ACCEPTANCE CHECKLIST Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators |
246 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d) |
247 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d) |
248 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d) |
249 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d) |
250 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators |
251 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d) |
252 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d) |
253 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d) |
254 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d) |
255 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d) |
256 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators |
257 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
258 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
259 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
260 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
261 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
262 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
263 | Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d) |
264 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators |
265 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
266 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
267 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
268 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
269 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
270 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
271 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
272 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
273 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
274 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d) |
275 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators |
276 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
277 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
278 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
279 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
280 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
281 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
282 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
283 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
284 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
285 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
286 | Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d) |
287 | NONMANDATORY APPENDIX C GUIDELINES FOR B44.1/ A17.5– 2004 C- 1 GENERAL C- 2 GUIDELINES FOR ELECTRICAL DEVICES REQUIRING LABELING/ MARKING |