Shopping Cart

No products in the cart.

ASME A17.2 2012

$98.04

ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving Walks

Published By Publication Date Number of Pages
ASME 2012 292
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Guide covers recommended inspection and testing procedures for electric and hydraulic elevators, escalators, and moving walks required to conform to the Safety Code for Elevators and Escalators, A17.1-1955 and later editions and The Safety Code for Existing Elevators and Escalators, A17.3. This Guide also addresses some requirements from editions of A17.1 prior to 1955. NOTE: This Guide may not reflect the latest requirements in the current A17.1 and A17.3 Codes.

PDF Catalog

PDF Pages PDF Title
5 CONTENTS
12 FOREWORD
15 COMMITTEE ROSTER
20 PREFACE
22 Abbreviations Used in This Code
23 SUMMARY OF CHANGES
25 Introduction
1 SCOPE
2 APPLICATION
26 3 QUALIFICATIONS OF INSPECTORS
4 PERSONAL SAFETY
5 DUTIES OF INSPECTORS
27 6 ARRANGEMENT FOR INSPECTION
7 RECOMMENDED EQUIPMENT
8 REFERENCE DOCUMENTS
28 Table 1 Procurement Information
29 Part 1 Elevator — Inside of Car
ITEM 1.1 DOOR REOPENING DEVICE
1.1.1 Periodic Inspections
1.1.2 Periodic Test 1.1.3 Acceptance 1.1.4 References
ITEM 1.2 STOP SWITCHES
1.2.1 Periodic Inspections
1.2.2 Periodic Test 1.2.3 Acceptance 1.2.4 References
30 ITEM 1.3 OPERATING CONTROL DEVICES
1.3.1 Periodic Inspections
1.3.2 Periodic Test 1.3.3 Acceptance 1.3.4 References
ITEM 1.4 SILLS AND CAR FLOOR
1.4.1 Periodic Inspections
31 1.4.2 Periodic Test 1.4.3 Acceptance
1.4.4 References
ITEM 1.5 CAR LIGHTING AND RECEPTACLES
1.5.1 Periodic Inspections
1.5.2 Periodic Test 1.5.3 Acceptance
1.5.4 References
32 ITEM 1.6 CAR EMERGENCY SIGNAL
1.6.1 Periodic Inspections
1.6.2 Periodic Test
1.6.3 Acceptance 1.6.4 References
ITEM 1.7 CAR DOOR OR GATE
1.7.1 Periodic Inspections
1.7.2 Periodic Test 1.7.3 Acceptance
33 1.7.4 References
ITEM 1.8 DOOR CLOSING FORCE
1.8.1 Periodic Inspections
1.8.2 Periodic Test: Category 1 ( Annual) Test
1.8.3 Acceptance 1.8.4 References
ITEM 1.9 POWER CLOSING OF DOORS OR GATES
1.9.1 Periodic Inspections
1.9.2 Periodic Test 1.9.3 Acceptance 1.9.4 References
ITEM 1.10 POWER OPENING OF DOORS OR GATES
1.10.1 Periodic Inspections
1.10.2 Periodic Test
34 1.10.3 Acceptance 1.10.4 References
ITEM 1.11 CAR VISION PANELS AND GLASS CAR DOORS
1.11.1 Periodic Inspections
1.11.2 Periodic Test 1.11.3 Acceptance
1.11.4 References
35 Fig. 1.10.2 Door Operation Relative to Car Position
36 ITEM 1.12 CAR ENCLOSURE
1.12.1 Periodic Inspections
1.12.2 Periodic Test 1.12.3 Acceptance
37 1.12.4 References
ITEM 1.13 EMERGENCY EXIT
1.13.1 Periodic Inspections
1.13.2 Periodic Test 1.13.3 Acceptance 1.13.4 References
ITEM 1.14 VENTILATION
1.14.1 Periodic Inspections
1.14.2 Periodic Test 1.14.3 Acceptance 1.14.4 References
38 ITEM 1.15 SIGNS AND OPERATING DEVICE SYMBOLS
1.15.1 Periodic Inspections
1.15.2 Periodic Test 1.15.3 Acceptance 1.15.4 References
ITEM 1.16 RATED LOAD, PLATFORM AREA, AND DATA PLATE
1.16.1 Periodic Inspections
1.16.2 Periodic Test 1.16.3 Acceptance
1.16.4 References
ITEM 1.17 STANDBY POWER OPERATION
1.17.1 Periodic Inspections
1.17.2 Periodic Test
39 1.17.3 Acceptance
1.17.4 References
ITEM 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS
1.18.1 Periodic Inspections
40 1.18.2 Periodic Test 1.18.3 Acceptance
1.18.4 References
ITEM 1.19 CAR RIDE
1.19.1 Periodic Inspections
1.19.2 Periodic Test 1.19.3 Acceptance 1.19.4 References
ITEM 1.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
1.20.1 Periodic Inspections
1.20.2 Periodic Test 1.20.3 Acceptance
1.20.4 References
41 Part 2 Elevator — Machine Room
ITEM 2.1 ACCESS TO MACHINE SPACE
2.1.1 Periodic Inspections
2.1.2 Periodic Test 2.1.3 Acceptance
2.1.4 References
ITEM 2.2 HEADROOM
2.2.1 Periodic Inspections 2.2.2 Periodic Test 2.2.3 Acceptance
2.2.4 References
ITEM 2.3 LIGHTING AND RECEPTACLES
2.3.1 Periodic Inspections
2.3.2 Periodic Test 2.3.3 Acceptance 2.3.4 References
42 ITEM 2.4 MACHINE SPACE
2.4.1 Periodic Inspections
2.4.2 Periodic Test 2.4.3 Acceptance
2.4.4 References
ITEM 2.5 HOUSEKEEPING
2.5.1 Periodic Inspections
2.5.2 Periodic Test 2.5.3 Acceptance 2.5.4 References
43 ITEM 2.6 VENTILATION
2.6.1 Periodic Inspections
2.6.2 Periodic Test 2.6.3 Acceptance
2.6.4 References
ITEM 2.7 FIRE EXTINGUISHER
2.7.1 Periodic Inspections
2.7.2 Periodic Test 2.7.3 Acceptance 2.7.4 References
ITEM 2.8 PIPES, WIRING, AND DUCTS
2.8.1 Periodic Inspections
2.8.2 Periodic Test 2.8.3 Acceptance
2.8.4 References
44 ITEM 2.9 GUARDING OF EXPOSED AUXILIARY EQUIPMENT
2.9.1 Periodic Inspections
2.9.2 Periodic Test 2.9.3 Acceptance 2.9.4 References
ITEM 2.10 NUMBERING OF ELEVATORS, MACHINES, CONTROLLERS, AND DISCONNECT SWITCHES
2.10.1 Periodic Inspections
2.10.2 Periodic Test 2.10.3 Acceptance
2.10.4 References
ITEM 2.11 DISCONNECTING MEANS AND CONTROL
2.11.1 Periodic Inspections
2.11.2 Periodic Test 2.11.3 Acceptance
45 2.11.4 References
ITEM 2.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC.
2.12.1 Periodic Inspections
46 2.12.2 Periodic Test 2.12.3 Acceptance
2.12.4 References
ITEM 2.13 GOVERNOR, OVERSPEED SWITCH, AND SEAL
2.13.1 Periodic Inspections
2.13.2 Periodic Test
48 Tables

Table 2.13.2.1 Governor Adjustment Settings
49 Figures

Fig. 2.13.2.1 Dynamometer Connections for Testing the Pull- Through of Governor Jaws
50 2.13.3 Acceptance
51 2.13.4 References
ITEM 2.14 CODE DATA PLATE
2.14.1 Periodic Inspections
2.14.2 Periodic Test 2.14.3 Acceptance 2.14.4 References
ITEM 2.15 STATIC CONTROL
2.15.1 Periodic Inspections 2.15.2 Periodic Test
2.15.3 Acceptance 2.15.4 References
52 ITEM 2.16 OVERHEAD BEAM AND FASTENINGS
2.16.1 Periodic Inspections
2.16.2 Periodic Test 2.16.3 Acceptance
2.16.4 References
ITEM 2.17 DRIVE MACHINE BRAKE
2.17.1 Periodic Inspections
2.17.2 Periodic Test
53 2.17.3 Acceptance
2.17.4 References
ITEM 2.18 TRACTION DRIVE MACHINES
2.18.1 Periodic Inspections
2.18.2 Periodic Test
2.18.3 Acceptance 2.18.4 References
ITEM 2.19 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS
2.19.1 Periodic Inspections
54 2.19.2 Periodic Test
2.19.3 Acceptance 2.19.4 References
ITEM 2.20 WINDING DRUM MACHINE AND SLACK ROPE DEVICE, STOP MOTION SWITCH, AND ROPE FASTENING
2.20.1 Periodic Inspections
55 2.20.2 Periodic Test
2.20.3 Acceptance
2.20.4 References
ITEM 2.21 BELT- OR CHAIN- DRIVE MACHINE
2.21.1 Periodic Inspections
2.21.2 Periodic Test 2.21.3 Acceptance 2.21.4 References
56 ITEM 2.22 MOTOR GENERATOR
2.22.1 Periodic Inspections
2.22.2 Periodic Test 2.22.3 Acceptance Test of Generator Suicide Circuit
2.22.4 References
ITEM 2.23 ABSORPTION OF REGENERATED POWER
2.23.1 Periodic Inspections 2.23.2 Periodic Test 2.23.3 Acceptance
2.23.4 References
ITEM 2.24 AC DRIVES FROM A DC SOURCE
2.24.1 Periodic Inspections 2.24.2 Periodic Test
2.24.3 Acceptance
2.24.4 References
57 ITEM 2.25 TRACTION SHEAVES
2.25.1 Periodic Inspections
2.25.2 Periodic Test
2.25.3 Acceptance
2.25.4 References
ITEM 2.26 SECONDARY AND DEFLECTOR SHEAVES
2.26.1 Periodic Inspections
2.26.2 Periodic Test 2.26.3 Acceptance
2.26.4 References
ITEM 2.27 ROPE FASTENINGS
2.27.1 Periodic Inspections
58 2.27.2 Periodic Test 2.27.3 Acceptance 2.27.4 References
ITEM 2.28 TERMINAL STOPPING DEVICES
2.28.1 Periodic Inspections
2.28.2 Periodic Test
2.28.3 Acceptance
2.28.4 References
59 ITEM 2.29 CAR AND COUNTERWEIGHT SAFETIES
2.29.1 Periodic Inspections
2.29.2 Periodic Test
Table 2.29.2( a) Maximum Safety Rope Pullout
61 Table 2.29.2( b) Minimum and Maximum Stopping Distances for Type B Car Safeties With Rated Load, and Type B Counterweight Safeties With No Load in the Car
62 Table 2.29.2( c) Gradual Wedge Clamp Safety
Table 2.29.2( d) Flexible Guide Clamp Safety
Table 2.29.2( e) Wedge Clamp Safety ( Constant Retarding Force)
63 Fig. 2.29.2( a) Safety Marks on Guide Rails, Poor Illumination
Fig. 2.29.2( b) Safety Marks on Guide Rails, Good Illumination
64 2.29.3 Acceptance Test of Governor and Safeties
2.29.4 References
ITEM 2.30 HYDRAULIC POWER UNIT
2.30.1 Periodic Inspections
2.30.3 Acceptance 2.30.4 References
ITEM 2.31 RELIEF VALVES
2.31.1 Periodic Inspections
2.31.2 Periodic Test
65 2.31.3 Acceptance
2.31.4 References
ITEM 2.32 CONTROL VALVE
2.32.1 Periodic Inspections
2.32.2 Periodic Test 2.32.3 Acceptance
2.32.4 References
ITEM 2.33 TANKS
2.33.1 Periodic Inspections
66 2.33.2 Periodic Test
2.33.3 Acceptance
2.33.4 References
ITEM 2.34 FLEXIBLE HYDRAULIC HOSE AND FITTING ASSEMBLIES
2.34.1 Periodic Inspections
2.34.2 Periodic Test
67 2.34.3 Acceptance Test
2.34.4 References
ITEM 2.35 SUPPLY LINE AND SHUTOFF VALVE
2.35.1 Periodic Inspections
2.35.2 Periodic Test 2.35.3 Acceptance
2.35.4 References
Table 2.34.3 Minimum Bend Radius for SAE 100R2 Hose
68 ITEM 2.36 HYDRAULIC CYLINDERS
2.36.1 Periodic Inspections 2.36.2 Periodic Test
2.36.3 Acceptance 2.36.4 References
ITEM 2.37 PRESSURE SWITCH
2.37.1 Periodic Inspections
2.37.2 Periodic Test
2.37.3 Acceptance 2.37.4 References
ITEM 2.38 ROPED WATER HYDRAULIC ELEVATORS
2.38.1 Periodic Inspections 2.38.2 Periodic Test: 3- Year Test ( for A17.1d– 2000 and Earlier Editions); Category 3 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
2.38.3 Acceptance 2.38.4 References
ITEM 2.39 LOW OIL PROTECTION
2.39.1 Periodic Inspections 2.39.2 Periodic Test
69 2.39.3 Acceptance 2.39.4 References
ITEM 2.40 MAINTENANCE RECORDS
2.40.1 Periodic Inspections
2.40.4 References
ITEM 2.41 HYDRAULIC CONTROL
2.41.1 Periodic Inspections 2.41.2 Periodic Test 2.41.3 Acceptance
2.41.4 References
ITEM 2.42 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
2.42.1 Periodic inspection
2.42.2 Periodic Test 2.42.3 Acceptance
70 2.42.4 References
71 Part 3 Elevator — Top of Car
ITEM 3.1 TOP- OF- CAR STOP SWITCH
3.1.1 Periodic Inspections
3.1.2 Periodic Test 3.1.3 Acceptance 3.1.4 References
ITEM 3.2 CAR TOP LIGHT AND OUTLET
3.2.1 Periodic Inspections
3.2.2 Periodic Test 3.2.3 Acceptance
3.2.4 References
ITEM 3.3 TOP- OF- CAR OPERATING DEVICE
3.3.1 Periodic Inspections
3.3.2 Acceptance
3.3.3 References
72 ITEM 3.4 TOP- OF- CAR CLEARANCE, REFUGE SPACE, AND STANDARD RAILING
3.4.1 Periodic Inspections
3.4.2 Periodic Test 3.4.3 Acceptance
73 3.4.4 References
ITEM 3.5 NORMAL TERMINAL STOPPING DEVICES
3.5.1 Periodic Inspections
Fig. 3.4.1.2 Top Car Clearance and Runby ( A17.1– 1978 and Later Editions)
74 3.5.2 Periodic Test
3.5.3 Acceptance
3.5.4 References
ITEM 3.6 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
3.6.1 Periodic Inspections
75 3.6.2 Periodic Test
3.6.3 Acceptance 3.6.4 References
ITEM 3.7 CAR LEVELING AND ANTICREEP DEVICES
3.7.1 Periodic Inspections
76 3.7.2 Periodic Test 3.7.3 Acceptance 3.7.4 References
ITEM 3.8 TOP EMERGENCY EXIT
3.8.1 Periodic Inspections
3.8.2 Periodic Test 3.8.3 Acceptance
3.8.4 References
ITEM 3.9 FLOOR AND EMERGENCY IDENTIFICATION NUMBERING
3.9.1 Periodic Inspections
3.9.2 Periodic Test

3.9.3 Acceptance
3.9.4 References
ITEM 3.10 HOISTWAY CONSTRUCTION
3.10.1 Periodic Inspections
77 3.10.2 Periodic Test

3.10.3 Acceptance
3.10.4 References
ITEM 3.11 HOISTWAY SMOKE CONTROL
3.11.1 Periodic Inspections
3.11.2 Periodic Test 3.11.3 Acceptance
3.11.4 References
ITEM 3.12 PIPES, WIRING, AND DUCTS
3.12.1 Periodic Inspections
3.12.2 Periodic Test 3.12.3 Acceptance
3.12.4 References
ITEM 3.13 WINDOWS, PROJECTIONS, RECESSES, AND SETBACKS
3.13.1 Periodic Inspections
78 3.13.2 Periodic Test 3.13.3 Acceptance 3.13.4 References
ITEM 3.14 HOISTWAY CLEARANCES
3.14.1 Periodic Inspections
3.14.2 Periodic Test 3.14.3 Acceptance
3.14.4 References
ITEM 3.15 MULTIPLE HOISTWAYS
3.15.1 Periodic Inspections
3.15.2 Periodic Test 3.15.3 Acceptance
3.15.4 References
ITEM 3.16 TRAVELING CABLES AND JUNCTION BOXES
3.16.1 Periodic Inspections
79 Table 3.14.3( a) Horizontal Clearances
Table 3.14.3( b) Horizontal Distances
80 3.16.2 Periodic Test 3.16.3 Acceptance
3.16.4 References
ITEM 3.17 DOOR AND GATE EQUIPMENT
3.17.1 Periodic Inspections
Fig. 3.16.1 Self- Tightening Grips
82 3.17.2 Periodic Test 3.17.3 Acceptance
3.17.4 References
ITEM 3.18 CAR FRAME AND STILES
3.18.1 Periodic Inspections
3.18.2 Periodic Test 3.18.3 Acceptance 3.18.4 References
ITEM 3.19 GUIDE RAILS FASTENING AND EQUIPMENT
3.19.1 Periodic Inspections
83 3.19.2 Periodic Test 3.19.3 Acceptance
3.19.4 References
ITEM 3.20 GOVERNOR ROPE
3.20.1 Periodic Inspections
3.20.2 Periodic Test 3.20.3 Acceptance
3.20.4 References
ITEM 3.21 GOVERNOR RELEASING CARRIER
3.21.1 Periodic Inspections
3.21.2 Periodic Test: 5- Year Test ( for A17.1d– 2000 and Earlier Editions); Category 5 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
3.21.3 Acceptance 3.21.4 References
84 Fig. 3.22.1 Cross- Section Through Tapered Rope Socket Showing Maximum and Minimum Projection of Loops Above Embedment Medium
ITEM 3.22 WIRE ROPE FASTENING AND HITCH PLATE
3.22.1 Periodic Inspections
Table 3.22.1 Projection of Rope Strands Above Embedment Medium for 6- and 8- Strand Ropes
85 3.22.2 Periodic Test 3.22.3 Acceptance 3.22.4 References
ITEM 3.23 SUSPENSION ROPE
3.23.1 Periodic Inspections
86 Fig. 3.23.1 Types of Lay
87 Fig. 3.23.2 Cross Sections of Typical Wire Ropes
88 3.23.2 Periodic Test 3.23.3 Acceptance 3.23.4 References
ITEM 3.24 TOP COUNTERWEIGHT CLEARANCE
3.24.1 Periodic Inspections
3.24.2 Periodic Test 3.24.3 Acceptance
3.24.4 References
89 ITEM 3.25 CAR, OVERHEAD, AND DEFLECTOR SHEAVES
3.25.1 Periodic Inspections
3.25.2 Periodic Test 3.25.3 Acceptance
3.25.4 References
ITEM 3.26 BROKEN ROPE, CHAIN, OR TAPE SWITCH
3.26.1 Periodic Inspections
3.26.2 Periodic Test 3.26.3 Acceptance 3.26.4 References
ITEM 3.27 CROSSHEAD DATA PLATE AND ROPE DATA TAGS
3.27.1 Periodic Inspections 3.27.2 Periodic Test 3.27.3 Acceptance
3.27.4 References
ITEM 3.28 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER
3.28.1 Periodic Inspections
90 3.28.2 Periodic Test 3.28.3 Acceptance
3.28.4 References
ITEM 3.29 COUNTERWEIGHT SAFETIES
3.29.1 Periodic Inspections
3.29.2 Periodic Test
3.29.3 Acceptance
3.29.4 References
91 ITEM 3.30 SPEED TEST
3.30.1 Periodic Inspections 3.30.2 Periodic Test 3.30.3 Acceptance
3.30.4 References
ITEM 3.31 SLACK ROPE DEVICE — ROPED- HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS
3.31.1 Periodic Inspections
3.31.2 Periodic Test
3.31.3 Acceptance
3.31.4 References
ITEM 3.32 TRAVELING SHEAVE — ROPED-HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS
3.32.1 Periodic Inspections
92 3.32.2 Periodic Test 3.32.3 Acceptance
3.32.4 References
ITEM 3.33 COMPENSATING ROPES AND CHAINS
3.33.1 Periodic Inspections
3.33.2 Periodic Test 3.33.3 Acceptance 3.33.4 References
ITEM 3.34 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
3.34.1 Periodic Inspection
3.34.2 Periodic Test 3.34.3 Acceptance
93 3.34.4 References
94 Part 4 Elevator — Outside Hoistway
ITEM 4.1 CAR PLATFORM GUARD
4.1.1 Periodic Inspections
4.1.2 Periodic Test 4.1.3 Acceptance
4.1.4 References
ITEM 4.2 HOISTWAY DOORS
4.2.1 Periodic Inspections
95 4.2.2 Periodic Test 4.2.3 Acceptance
4.2.4 References
ITEM 4.3 VISION PANELS
4.3.1 Periodic Inspections
4.3.2 Periodic Test 4.3.3 Acceptance
4.3.4 References
ITEM 4.4 HOISTWAY DOOR LOCKING DEVICES
4.4.1 Periodic Inspections
96 4.4.2 Periodic Test 4.4.3 Acceptance
4.4.4 References
ITEM 4.5 ACCESS TO HOISTWAY
4.5.1 Periodic Inspections
4.5.2 Periodic Test 4.5.3 Acceptance 4.5.4 References
ITEM 4.6 POWER CLOSING OF HOISTWAY DOORS
4.6.1 Periodic Inspections 4.6.2 Periodic Test 4.6.3 Acceptance
4.6.4 References
97 ITEM 4.7 SEQUENCE OPERATION
4.7.1 Periodic Inspections
4.7.2 Periodic Test 4.7.3 Acceptance 4.7.4 References
ITEM 4.8 HOISTWAY ENCLOSURE
4.8.1 Periodic Inspections
4.8.2 Periodic Test 4.8.3 Acceptance
4.8.4 References
ITEM 4.9 ELEVATOR PARKING DEVICES
4.9.1 Periodic Inspections
4.9.2 Periodic Test 4.9.3 Acceptance
4.9.4 References
98 ITEM 4.10 EMERGENCY DOORS IN BLIND HOISTWAYS
4.10.1 Periodic Inspections
4.10.2 Periodic Test 4.10.3 Acceptance
4.10.4 References
ITEM 4.11 SEPARATE COUNTERWEIGHT HOISTWAY
4.11.1 Periodic Inspections
4.11.2 Periodic Test 4.11.3 References
ITEM 4.12 STANDBY POWER SELECTION SWITCH
4.12.1 Periodic Inspections
4.12.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
4.12.3 Acceptance 4.12.4 References
100 Part 5 Elevator — Pit
ITEM 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
5.1.1 Periodic Inspections
5.1.2 Periodic Test 5.1.3 Acceptance
101 5.1.4 References
ITEM 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE
5.2.1 Periodic Inspections
5.2.2 Periodic Test 5.2.3 Acceptance
102 5.2.4 References
Fig. 5.2.3 Bottom Car Clearance Hydraulic Elevators
103 ITEM 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
5.3.1 Periodic Inspections
5.3.2 Periodic Test
5.3.3 Acceptance 5.3.4 References
ITEM 5.4 NORMAL TERMINAL STOPPING DEVICES
5.4.1 Periodic Inspections
5.4.2 Periodic Test
5.4.3 Acceptance 5.4.4 References
ITEM 5.5 TRAVELING CABLES
5.5.1 Periodic Inspections
5.5.2 Periodic Test 5.5.3 Acceptance 5.5.4 References
104 ITEM 5.6 GOVERNOR- ROPE TENSION DEVICES
5.6.1 Periodic Inspections
5.6.2 Periodic Test 5.6.3 Acceptance
5.6.4 References
ITEM 5.7 CAR FRAME AND PLATFORM
5.7.1 Periodic Inspections
5.7.2 Periodic Test 5.7.3 Acceptance
5.7.4 References
ITEM 5.8 CAR AND COUNTERWEIGHT SAFETIES AND GUIDING MEMBERS — INCLUDING ROPED- HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b– 1989 AND LATER EDITIONS
5.8.1 Periodic Inspections
105 5.8.2 Periodic Test
5.8.3 Acceptance
5.8.4 References
106 ITEM 5.9 BUFFER AND EMERGENCY TERMINAL SPEED LIMITING DEVICES
5.9.1 Periodic Inspections
5.9.2 Periodic Test
107 5.9.3 Acceptance
5.9.4 References
ITEM 5.10 COMPENSATING CHAINS, ROPES, AND SHEAVES
5.10.1 Periodic Inspections
5.10.2 Periodic Test 5.10.3 Acceptance
5.10.4 References
108 ITEM 5.11 PLUNGER AND CYLINDER
5.11.1 Periodic Inspections
5.11.2 Periodic Test 5.11.3 Acceptance 5.11.4 References
ITEM 5.12 CAR BUFFER
5.12.1 Periodic Inspections
5.12.2 Periodic Test 5.12.3 Acceptance
5.12.4 References
ITEM 5.13 GUIDING MEMBERS
5.13.1 Periodic Inspections
5.13.2 Periodic Test 5.13.3 Acceptance 5.13.4 References
ITEM 5.14 SUPPLY PIPING
5.14.1 Periodic Inspections
109 5.14.2 Periodic Test 5.14.3 Acceptance
5.14.4 References
ITEM 5.15 OVERSPEED VALVE
5.15.1 Periodic Inspections 5.15.2 Category 5 Periodic Test
5.15.3 Acceptance
5.15.4 References
ITEM 5.16 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
5.16.1 Periodic Inspections
5.16.2 Periodic Test
110 5.16.3 Acceptance
5.16.4 References
111 Part 6 Elevator — Firefighters’ Service
ITEM 6.1 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS ( A17.1b– 1973 THROUGH A17.1b– 1980)
6.1.1 Periodic Inspections
6.1.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
112 6.1.3 Acceptance 6.1.4 References
113 ITEM 6.2 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS ( A17.1– 1981 THROUGH A17.1b– 1983)
6.2.1 Periodic Inspections
6.2.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
114 6.2.3 Acceptance 6.2.4 References
115 ITEM 6.3 FIREFIGHTERS’ SERVICE ( A17.1– 1984 THROUGH A17.1a– 1988 and A17.3)
6.3.1 Periodic Inspections
6.3.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
117 6.3.3 Acceptance 6.3.4 References
ITEM 6.4 FIREFIGHTERS’ SERVICE ( A17.1b– 1989 THROUGH A17.1d– 2000)
6.4.1 Periodic Inspections
6.4.2 Periodic Test: Yearly Test ( for A17.1d– 2000 and Earlier Editions); Category 1 Test ( for A17.1– 2000/ B44- 00 and Later Editions)
118 Fig. 6.4.2( b)( 9) Visual Signal
119 Fig. 6.4.2( g)( 1) Phase I Instructions
120 Fig. 6.4.2( g)( 2) Phase II Instructions ( A17.1b– 1989 Through A17.1b– 1995)
Fig. 6.4.2( g)( 3) Phase II Instructions ( A17.1– 1996 Through A17.1d– 2000)
121 6.4.3 Acceptance 6.4.4 References
ITEM 6.5 ACCEPTANCE CHECKLIST FOR FIREFIGHTERS’ SERVICE ( ASME A17.1– 2000 and CSA B44- 00): AUTOMATIC ELEVATORS
6.5.1 Emergency Signaling Devices
6.5.2 Phase I Key Switch and Instructions
6.5.3 Phase II In- Car Switch and Instruction
6.5.4 Monthly Test
6.5.5 Phase I Operation While Running
122 6.5.6 Phase I Operation With Doors Open
6.5.7 Emergency Stop Switch and/ or In- Car Stop Switch and Doors Closing
6.5.8 Stop Switches and Door Buttons
6.5.9 Fire Alarm- Initiating Device and Operation
6.5.10 Fire Alarm- Initiating Device and Phase I Switch
6.5.11 Phase II Key Switch and Sign
123 6.5.12 Phase II Switch in ” HOLD” Position
6.5.13 Phase II Switch in ” OFF” Position and Doors Closing: Power- Operated Horizontally and Vertically Sliding Doors
6.5.14 Removal From Phase II
6.5.15 Power Disconnects Open
6.5.16 Top- of- Car Operating Device
6.5.17 Automatic Elevators With Attendant Operation
6.5.18 Elevators on Phase I and Phase II, Prevention of Operation and Disabling Not Allowed
124 Part 7 Escalator — External
ITEM 7.1 GENERAL FIRE PROTECTION
7.1.1 Periodic Inspections
7.1.2 Periodic Test 7.1.3 Acceptance
7.1.4 References
ITEM 7.2 GEOMETRY
7.2.1 Periodic Inspections
7.2.2 Periodic Test
7.2.3 Acceptance
7.2.4 References
125 Fig. 7.2.1( a) Dimensions for Existing Escalators ( for Escalators Installed Under A17.1– 1955 and A17.1– 1960 Editions)
126 Fig. 7.2.1( b) Dimensions for Existing Escalators ( for Escalators Installed Under A17.1– 1965 Through A17.1– 1981)
127 Fig. 7.2.1( c) Relationship of Escalator Parts ( A17.1a– 1982 and Later Editions)
Fig. 7.2.3 Checking Incline
128 ITEM 7.3 HANDRAILS
7.3.1 Periodic Inspections
7.3.2 Periodic Test
7.3.3 Acceptance
7.3.4 References
ITEM 7.4 ENTRANCE AND EGRESS ENDS
7.4.1 Periodic Inspections
Fig. 7.4.1 Safety Zone
129 7.4.2 Periodic Test 7.4.3 Acceptance
7.4.4 References
ITEM 7.5 LIGHTING
7.5.1 Periodic Inspections
7.5.2 Periodic Test 7.5.3 Acceptance 7.5.4 References
ITEM 7.6 CAUTION SIGNS
7.6.1 Periodic Inspections
7.6.2 Periodic Test 7.6.3 Acceptance 7.6.4 References
ITEM 7.7 COMBPLATE AND COMB STEP IMPACT DEVICE
7.7.1 Periodic Inspections
7.7.2 Periodic Test
130 7.7.3 Acceptance
7.7.4 References
Fig. 7.7.1 Checking Step/ Combplate Mesh
131 ITEM 7.8 DECK BARRICADES AND ANTISLIDE DEVICES
7.8.1 Periodic Inspections
7.8.2 Periodic Test
7.8.3 Acceptance
7.8.4 References
Fig. 7.7.3 Test of Combplate/ Landing Plate Assembly
132 Fig. 7.8.1( a) Deck Barricade
Fig. 7.8.1( b) High Deck Balustrade Antislide Devices
133 ITEM 7.9 STEPS AND UPTHRUST DEVICE
7.9.1 Periodic Inspections
Fig. 7.9.1( a) Smooth Riser
134 Fig. 7.9.1( b) Cleated Riser
Fig. 7.9.1( c) Escalator Step Riser
135 7.9.2 Periodic Test
7.9.3 Acceptance
7.9.4 References
ITEM 7.10 OPERATING AND SAFETY DEVICES
7.10.1 Periodic Inspections
Fig. 7.9.1( d) Escalator Step Tread [ A17.1– 1955 Through A17.1– 1990, Rule 802.5 ( Requirement 6.1.3.5)]
136 Fig. 7.9.3 Example of Two Flat Steps
137 7.10.2 Periodic Test 7.10.3 Acceptance
7.10.4 References
ITEM 7.11 SKIRT OBSTRUCTION DEVICE
7.11.1 Periodic Inspections
7.11.2 Periodic Test 7.11.3 Acceptance 7.11.4 References
ITEM 7.12 ( RESERVED) ITEM 7.13 EGRESS RESTRICTION ( ROLLING SHUTTER) DEVICE
7.13.1 Periodic Inspections
7.13.2 Periodic Test 7.13.3 Acceptance 7.13.4 References
ITEM 7.14 SPEED
7.14.1 Periodic Inspections
138 Fig. 7.11.1 Typical Skirt Obstruction Device
139 7.14.2 Periodic Test 7.14.3 Acceptance
7.14.4 References
ITEM 7.15 BALUSTRADES
7.15.1 Periodic Inspections
7.15.2 Periodic Test
7.15.3 Acceptance
7.15.4 References
ITEM 7.16 CEILING INTERSECTION GUARDS
7.16.1 Periodic Inspections
7.16.2 Periodic Test 7.16.3 Acceptance
7.16.4 References
ITEM 7.17 STEP/ SKIRT CLEARANCES, PANELS, AND PERFORMANCE INDEX
7.17.1 Periodic Inspections
140 Fig. 7.16.1 Ceiling or Soffit Guard [ Requirements 6.1.3.3.9 and 6.2.3.3.7 ( Rules 802.3g and 902.3g)]
Fig. 7.17.1 Measuring Gap Between Step and Skirt
141 7.17.2 Periodic Test
Fig. 7.17.2 Angle of Skirt Panel
142 7.17.3 Acceptance
7.17.4 References
ITEM 7.18 OUTDOOR PROTECTION
7.18.1 Periodic Inspections
7.18.2 Periodic Test
7.18.3 Acceptance
7.18.4 References
ITEM 7.19 MAINTENANCE RECORDS
7.19.1 Periodic Inspections
143 7.19.2 Periodic Test 7.19.3 Acceptance 7.19.4 References
ITEM 7.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
7.20.1 Periodic Inspections 7.20.2 Periodic Test
7.20.3 Acceptance
7.20.4 References
144 Fig. 7.18.3 Escalator Cover Overlap
145 Part 8 Escalator — Internal
ITEM 8.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION
8.1.1 Periodic Inspections
8.1.2 Periodic Test
8.1.3 Acceptance
8.1.4 References
ITEM 8.2 MACHINERY SPACE STOP SWITCHES AND INSPECTION CONTROL
8.2.1 Periodic Inspections
8.2.2 Periodic Test
146 8.2.3 Acceptance
8.2.4 References
ITEM 8.3 CONTROLLER AND WIRING
8.3.1 Periodic Inspections
8.3.2 Periodic Test
8.3.3 Acceptance
8.3.4 References
ITEM 8.4 DRIVE MACHINE AND BRAKE
8.4.1 Periodic Inspections 8.4.2 Periodic Test
147 8.4.3 Acceptance
8.4.4 References
148 ITEM 8.5 SPEED GOVERNOR
8.5.1 Periodic Inspections 8.5.2 Periodic Test
8.5.3 Acceptance
8.5.4 References
ITEM 8.6 BROKEN DRIVE CHAIN AND DISCONNECTED MOTOR SAFETY DEVICE
8.6.1 Periodic Inspections 8.6.2 Periodic Test
8.6.3 Acceptance 8.6.4 References
ITEM 8.7 REVERSAL STOP SWITCH
8.7.1 Periodic Inspections 8.7.2 Periodic Test
149 8.7.3 Acceptance 8.7.4 References
ITEM 8.8 BROKEN STEP CHAIN DEVICE
8.8.1 Periodic Inspections 8.8.2 Periodic Test
8.8.3 Acceptance 8.8.4 References
ITEM 8.9 STEP UPTHRUST DEVICE
8.9.1 Periodic Inspections 8.9.2 Periodic Test
8.9.3 Acceptance 8.9.4 References
ITEM 8.10 MISSING STEP DEVICE
8.10.1 Periodic Inspections 8.10.2 Periodic Test
8.10.3 Acceptance 8.10.4 References
150 ITEM 8.11 STEP LEVEL DEVICE
8.11.1 Periodic Inspections 8.11.2 Periodic Test
8.11.3 Acceptance
8.11.4 References
ITEM 8.12 STEPS, STEP CHAINS, AND TRUSSES
8.12.1 Periodic Inspections 8.12.2 Periodic Test
Fig. 8.9.2 Typical Step Upthrust Device
151 8.12.3 Acceptance
8.12.4 References
Fig. 8.12.2 Positioning of Steps for Inspection of Truss
152 ITEM 8.13 HANDRAIL SYSTEMS AND SAFETY DEVICES
8.13.1 Periodic Inspections 8.13.2 Periodic Test
8.13.3 Acceptance 8.13.4 References
ITEM 8.14 CODE DATA PLATE
8.14.1 Periodic Inspections
8.14.2 Periodic Test 8.14.3 Acceptance 8.14.4 References
ITEM 8.15 RESPONSE TO SMOKE DETECTORS
8.15.1 Periodic Inspections 8.15.2 Periodic Test
8.15.3 Acceptance 8.15.4 References
153 ITEM 8.16 STEP LATERAL DISPLACEMENT DEVICE
8.16.1 Periodic Inspections 8.16.2 Periodic Test
8.16.3 Acceptance 8.16.4 References
ITEM 8.17 INSPECTION CONTROL
8.17.1 Periodic Inspections 8.17.2 Periodic Test
8.17.3 Acceptance
8.17.4 References
ITEM 8.18 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
8.18.1 Periodic Inspection 8.18.2 Periodic Test 8.18.3 Acceptance
8.18.4 References
154 Part 9 Moving Walk — External
ITEM 9.1 GENERAL FIRE PROTECTION
9.1.1 Periodic Inspections
9.1.2 Periodic Test 9.1.3 Acceptance
9.1.4 References
ITEM 9.2 GEOMETRY
9.2.1 Periodic Inspections
9.2.2 Periodic Test 9.2.3 Acceptance
9.2.4 References
ITEM 9.3 HANDRAILS
9.3.1 Periodic Inspections
155 9.3.2 Periodic Test
Fig. 9.2.1( a) Moving Walk Geometry ( for Moving Walks Installed Under A17.1– 1965 Through A17.1b– 1980)
156 Fig. 9.2.1( b) Moving Walk Geometry ( for Moving Walks Installed Under A17.1– 1981 Through A17.1a– 1991)
Fig. 9.2.3 Maximum Treadway Angle
157 9.3.3 Acceptance
9.3.4 References
ITEM 9.4 ENTRANCE AND EGRESS ENDS
9.4.1 Periodic Inspections
9.4.2 Periodic Test 9.4.3 Acceptance
9.4.4 References
ITEM 9.5 LIGHTING
9.5.1 Periodic Inspections
Table 9.2.3( a) Treadway Width ( A17.1– 1965 Through A17.1d– 1970)
Table 9.2.3( b) Treadway Width ( A17.1– 1971 and Later Editions)
Table 9.2.3( c) Minimum Treadway Width
158 9.5.2 Periodic Test 9.5.3 Acceptance 9.5.4 References
ITEM 9.6 CAUTION SIGNS
9.6.1 Periodic Inspections
9.6.2 Periodic Test 9.6.3 Acceptance 9.6.4 References
ITEM 9.7 COMBPLATE AND COMB STEP IMPACT DEVICE
9.7.1 Periodic Inspections
9.7.2 Periodic Test
Fig. 9.3.3 Moving Walk Handrail Extension ( A17.1– 1971 and Later Editions)
159 9.7.3 Acceptance
9.7.4 References
ITEM 9.8 DECK BARRICADES
9.8.1 Periodic Inspections
9.8.2 Periodic Test
9.8.3 Acceptance
9.8.4 References
ITEM 9.9 TREADWAYS
9.9.1 Periodic Inspections
160 9.9.2 Periodic Test 9.9.3 Acceptance
9.9.4 References
ITEM 9.10 OPERATING AND SAFETY DEVICES
9.10.1 Periodic Inspections
Fig. 9.9.1 Moving Walk Treadway Slots
161 9.10.2 Periodic Test 9.10.3 Acceptance
9.10.4 References
ITEM 9.11 ( RESERVED) ITEM 9.12 ( RESERVED) ITEM 9.13 EGRESS RESTRICTION ( ROLLING SHUTTER) DEVICE
9.13.1 Periodic Inspections
9.13.2 Periodic Test 9.13.3 Acceptance 9.13.4 References
ITEM 9.14 SPEED
9.14.1 Periodic Inspections
Table 9.14.1( a) Treadway Speed ( A17.1– 1981 and Later Editions)
162 9.14.2 Periodic Test 9.14.3 Acceptance
9.14.4 References
ITEM 9.15 BALUSTRADES
9.15.1 Periodic Inspections
9.15.2 Periodic Test 9.15.3 Acceptance
9.15.4 References
ITEM 9.16 CEILING INTERSECTION GUARDS
9.16.1 Periodic Inspections
Table 9.14.1( b) Treadway Speed ( A17.1– 1965 Through A17.1b– 1980)
Table 9.14.1( c) Treadway Speed ( A17.1– 1965 Through A17.1b– 1980)
163 Fig. 9.17.1 Treadway Clearances
9.16.2 Periodic Test 9.16.3 Acceptance
9.16.4 References
ITEM 9.17 SKIRT PANELS
9.17.1 Periodic Inspections
164 9.17.2 Periodic Test 9.17.3 Acceptance
9.17.4 References
ITEM 9.18 OUTDOOR PROTECTION
9.18.1 Periodic Inspections
9.18.2 Periodic Test
9.18.3 Acceptance
9.18.4 References
ITEM 9.19 MAINTENANCE RECORDS
9.19.1 Periodic Inspections
9.19.2 Periodic Test 9.19.3 Acceptance 9.19.4 References
ITEM 9.20 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
9.20.1 Periodic Inspections 9.20.2 Periodic Test
9.20.3 Acceptance
165 9.20.4 References
166 Part 10 Moving Walk — Internal
ITEM 10.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION
10.1.1 Periodic Inspections
10.1.2 Periodic Test
10.1.3 Acceptance
10.1.4 References
ITEM 10.2 STOP SWITCH AND INSPECTION CONTROL
10.2.1 Periodic Inspections
10.2.2 Periodic Test
10.2.3 Acceptance
167 10.2.4 References
ITEM 10.3 CONTROLLER AND WIRING
10.3.1 Periodic Inspections
10.3.2 Periodic Test
10.3.3 Acceptance
10.3.4 References
ITEM 10.4 DRIVE MACHINE AND BRAKE
10.4.1 Periodic Inspections 10.4.2 Periodic Test
168 10.4.3 Acceptance
10.4.4 References
ITEM 10.5 SPEED GOVERNOR
10.5.1 Periodic Inspections 10.5.2 Periodic Test
169 10.5.3 Acceptance
10.5.4 References
ITEM 10.6 BROKEN DRIVE CHAIN AND DISCONNECTED MOTOR SAFETY DEVICE
10.6.1 Periodic Inspections 10.6.2 Periodic Test
10.6.3 Acceptance 10.6.4 References
ITEM 10.7 REVERSAL STOP SWITCH
10.7.1 Periodic Inspections 10.7.2 Periodic Test
170 10.7.3 Acceptance 10.7.4 References
ITEM 10.8 BROKEN TREADWAY DEVICE
10.8.1 Periodic Inspections 10.8.2 Periodic Test
10.8.3 Acceptance 10.8.4 References
ITEM 10.9 ( RESERVED) ITEM 10.10 MISSING PALLET DEVICE
10.10.1 Periodic Inspections 10.10.2 Periodic Test
10.10.3 Acceptance 10.10.4 References
ITEM 10.11 PALLET LEVEL DEVICE
10.11.1 Periodic Inspections 10.11.2 Periodic Test
171 10.11.3 Acceptance
10.11.4 References
ITEM 10.12 PALLETS, PALLET CHAINS, AND TRUSSES
10.12.1 Periodic Inspections 10.12.2 Periodic Test
10.12.3 Acceptance
10.12.4 References
172 ITEM 10.13 HANDRAIL SYSTEMS AND SAFETY DEVICES
10.13.1 Periodic Inspections 10.13.2 Periodic Test
10.13.3 Acceptance 10.13.4 References
ITEM 10.14 CODE DATA PLATE
10.14.1 Periodic Inspections
10.14.2 Periodic Test 10.14.3 Acceptance 10.14.4 References
ITEM 10.15 RESPONSE TO SMOKE DETECTORS
10.15.1 Periodic Inspections 10.15.2 Periodic Test
173 10.15.3 Acceptance 10.15.4 References
ITEM 10.16 INSPECTION CONTROL
10.16.1 Periodic Inspections 10.16.2 Periodic Test
10.16.3 Acceptance
10.16.4 References
ITEM 10.17 EARTHQUAKE INSPECTION AND TESTS ( SEISMIC RISK ZONE 2 OR GREATER)
10.17.1 Periodic Inspections 10.17.2 Periodic Test 10.17.3 Acceptance
10.17.4 References
174 Part 11 Elevator — Machine- Room- Less ( MRL)
ITEM 11.1 ACCESS TO MACHINE ROOM/ MACHINERY SPACE/ CONTROL ROOM/ CONTROL SPACE
11.1.1 Periodic Inspections 11.1.2 Periodic Test 11.1.3 Acceptance
11.1.4 References
ITEM 11.2 ACCESS DOOR AND OPENINGS
11.2.1 Periodic Inspections
11.2.2 Periodic Test 11.2.3 Acceptance
11.2.4 References
ITEM 11.3 ENCLOSURE OF ROOMS AND SPACES
11.3.1 Periodic Inspections 11.3.2 Periodic Test 11.3.3 Acceptance
175 11.3.4 References
ITEM 11.4 MAINTENANCE PATH AND CLEARANCE
11.4.1 Periodic Inspections
11.4.2 Periodic Test 11.4.3 Acceptance
11.4.4 References
ITEM 11.5 MACHINE/ CONTROL ROOMS CONTAINING OVERHEAD DRIVE MACHINES
11.5.1 Periodic Inspections 11.5.2 Periodic Test 11.5.3 Acceptance
11.5.4 References
ITEM 11.6 TEMPERATURE/ HUMIDITY
11.6.1 Periodic Inspections 11.6.2 Periodic Test 11.6.3 Acceptance
11.6.4 References
ITEM 11.7 DISCONNECTING MEANS
11.7.1 Periodic Inspections 11.7.2 Periodic Test 11.7.3 Acceptance
11.7.4 References
ITEM 11.8 REMOTE MACHINE ROOMS AND CONTROL ROOMS
11.8.1 Periodic Inspections 11.8.2 Periodic Test 11.8.3 Acceptance
11.8.4 References
176 ITEM 11.9 INSPECTION AND TEST PANELS
11.9.1 Periodic Inspections 11.9.2 Periodic Test 11.9.3 Acceptance
11.9.4 References
ITEM 11.10 GOVERNOR, OVERSPEED SWITCH
11.10.1 Periodic Inspections 11.10.2 Periodic Test 11.10.3 Acceptance
11.10.4 References
ITEM 11.11 EMERGENCY BRAKE
11.11.1 Periodic Inspections 11.11.2 Periodic Test 11.11.3 Acceptance
177 11.11.4 References
ITEM 11.12 TRACTION SHEAVES
11.12.1 Periodic Inspections
11.12.2 Periodic Test 11.12.3 Acceptance
11.12.4 References
ITEM 11.13 SECONDARY AND DEFLECTOR SHEAVES
11.13.1 Periodic Inspections
11.13.2 Periodic Test 11.13.3 Acceptance
11.13.4 References
ITEM 11.14 TERMINAL STOPPING DEVICES
11.14.1 Periodic Inspections 11.14.2 Periodic Test 11.14.3 Acceptance
11.14.4 References
ITEM 11.15 WORKING AREAS INSIDE THE HOISTWAY AND IN THE PIT
11.15.1 Periodic Inspections 11.15.2 Periodic Test 11.15.3 Acceptance
178 11.15.4 References
ITEM 11.16 LOCATION OF MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, CONTROL ROOMS, AND EQUIPMENT
11.16.1 Periodic Inspections 11.16.2 Periodic Test 11.16.3 Acceptance 11.16.4 References
ITEM 11.17 HYDRAULIC ELEVATORS — SHUTOFF/ MANUAL LOWERING VALVES
11.17.1 Periodic Inspections 11.17.2 Periodic Test 11.17.3 Acceptance
11.17.4 References
ITEM 11.18 HYDRAULIC ELEVATORS — PRESSURE GAGE FITTINGS
11.18.1 Periodic Inspections 11.18.2 Periodic Test 11.18.3 Acceptance
11.18.4 References
ITEM 11.19 HYDRAULIC ELEVATORS — ATMOSPHERE STORAGE AND DISCHARGE TANKS
11.19.1 Periodic Inspections 11.19.2 Periodic Test 11.19.3 Acceptance
179 11.19.4 References
ITEM 11.20 HYDRAULIC ELEVATORS — PRESSURE PIPING
11.20.1 Periodic Inspections 11.20.2 Periodic Test 11.20.3 Acceptance
11.20.4 References
ITEM 11.21 EXPLANATORY FIGURES FOR DEFINITIONS OF ELEVATOR MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, CONTROL ROOM, REMOTE MACHINE ROOM, OR REMOTE CONTROL ROOM
ITEM 11.22 INSPECTION OPERATION AND HOISTWAY ACCESS SWITCH OPERATION HIERARCHY
Fig. 11.21- 1 Configuration A
Fig. 11.21- 2 Configuration B
Fig. 11.21- 3 Configuration C
180 Fig. 11.21- 4 Configuration D
Fig. 11.21- 5 Configuration E
181 Fig. 11.21- 6 Configuration F
Table 11.21 Definitions of Elevator Machinery Space, Machine Room, Control Space, Control Room, Remote Machine Room, or Remote Control Room
182 Table 11.22 Inspection Operation and Hoistway Access Switch Operation Hierarchy
183 MANDATORY APPENDIX I GUIDE FOR INSPECTION OF INCLINED ELEVATORS
FOREWORD
PREFACE
Part I- 1 Elevator — Inside of Car
ITEM I- 1.6 CAR EMERGENCY SIGNAL
ITEM I- 1.10 POWER OPENING OF DOORS
184 ITEM I- 1.11 CAR VISION PANELS AND CAR DOORS
ITEM I- 1.13 EMERGENCY EXIT
ITEM I- 1.16 RATED LOAD, PLATFORM AREA, AND DATA PLATE
ITEM I- 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS
185 Part I- 2 Inclined Elevators — Machine Room
ITEM I- 2.13 GOVERNOR, OVERSPEED SWITCH, AND SEAL
ITEM I- 2.20 WINDING DRUM MACHINE AND SLACK CABLE DEVICES
ITEM I- 2.28 TERMINAL STOPPING DEVICES
ITEM I- 2.29 CAR AND COUNTERWEIGHT SAFETIES
186 Part I- 3 Elevator — Top Car/ Uphill Emergency Exit/ End- Loading Top Car Door
ITEM I- 3.1 TOP- OF- CAR STOP SWITCH
187 ITEM I- 3.2 CAR TOP/ INSPECTION LOCATION LIGHT AND OUTLET
ITEM I- 3.3 TOP- OF- CAR EXTERIOR OPERATING DEVICE
ITEM I- 3.4 TOP- OF- CAR/ UPHILL- OF- CAR CLEARANCE AND REFUGE SPACE
ITEM I- 3.5 NORMAL TERMINAL STOPPING DEVICES
ITEM I- 3.6 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
ITEM I- 3.8 TOP/ UPHILL END EMERGENCY EXIT
ITEM I- 3.10 HOISTWAY CONSTRUCTION
188 ITEM I- 3.16 TRAVELING CABLES, JUNCTION BOXES, AND PROTECTIVE MEANS
ITEM I- 3.18 CAR FRAME ( CHASSIS)
ITEM I- 3.19 GUIDE RAILS FASTENING AND EQUIPMENT
ITEM I- 3.20 GOVERNOR ROPE
ITEM I- 3.23 SUSPENSION ROPE
189 Part I- 4 Elevator — Outside Hoistway
ITEM I- 4.1 CAR PLATFORM GUARD
ITEM I- 3.27 CROSSHEAD/ UPHILL CHASSIS MEMBER DATA PLATE
ITEM I- 4.5 ACCESS TO HOISTWAY
ITEM I- 4.8 HOISTWAY ENCLOSURE
190 Part I- 5 Elevator Pit
ITEM I- 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
ITEM I- 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE
ITEM I- 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
191 ITEM I- 5.4 NORMAL TERMINAL STOPPING DEVICES AND RETRACTABLE SILLS
ITEM I- 5.5 TRAVELING CABLES
ITEM I- 5.8 CAR SAFETIES AND GUIDING MEMBERS
Part I- 6 Elevator — Firefighters’ Service
ITEM I- 5.9 BUFFER AND EMERGENCY TERMINAL SPEED LIMITING DEVICES
192 Fig. I- 1.16.3 Net Platform Area Measurements
Fig. I- 2.13.2- 1 Static Governor Rope Drive
Fig. I- 2.13.2- 2 Wheel Driven Governor
193 Fig. I- 2.28.2 Retractable Sill
Fig. I- 3.4 Uphill Clearance
194 Fig. I- 4.1 Car Platform Guard
Fig. I- 5.1 Pits and Work Spaces
195 Fig. I- 5.2 Refuge Space When Conformance to Requirement 2.4.1 is Not Provided
196 Additional Checklist for Inclined Elevators
197 Additional Checklist for Inclined Elevators ( Cont’d)
198 MANDATORY APPENDIX II GUIDE FOR INSPECTION OF PRIVATE RESIDENCE ELECTRIC AND HYDRAULIC ELEVATORS
FOREWORD
PREFACE
Part II- 1 Inside of Car
ITEM II- 1.1 DOOR- REOPENING DEVICE
II- 1.1.1 Acceptance
199 II- 1.1.2 References
ITEM II- 1.2 STOP SWITCHES
II- 1.2.1 Acceptance
II- 1.2.2 References
ITEM II- 1.3 OPERATING CONTROL DEVICES
II- 1.3.1 Acceptance
II- 1.3.2 References
ITEM II- 1.4 SILLS AND CAR FLOOR
II- 1.4.1 Acceptance
II- 1.4.2 References
ITEM II- 1.5 CAR LIGHTING
II- 1.5.1 Acceptance
II- 1.5.2 References
ITEM II- 1.6 CAR EMERGENCY SIGNAL
II- 1.6.1 Acceptance
II- 1.6.2 References
ITEM II- 1.7 CAR DOOR OR GATE
II- 1.7.1 Acceptance
200 II- 1.7.2 References
ITEM II- 1.8 DOOR CLOSING FORCE
II- 1.8.1 Acceptance
II- 1.8.2 References
ITEM II- 1.9 POWER CLOSING OF DOORS OR GATES
II- 1.9.1 Acceptance
II- 1.9.2 References
ITEM II- 1.10 POWER OPENING OF DOORS OR GATES
II- 1.10.1 Acceptance
II- 1.10.2 References
ITEM II- 1.11 CAR VISION PANELS AND GLASS CAR DOORS
ITEM II- 1.12 CAR ENCLOSURE
II- 1.12.1 Acceptance
II- 1.12.2 References
ITEM II- 1.13 ACCESS PANELS
II- 1.13.1 Acceptance
201 II- 1.13.2 References
ITEM II- 1.14 VENTILATION
ITEM II- 1.15 SIGNS AND OPERATING DEVICE SYMBOLS
ITEM II- 1.16 RATED LOAD, PLATFORM AREA, AND DATA CAPACITY PLATE
II- 1.16.1 Acceptance
II- 1.16.2 References
ITEM II- 1.17 STANDBY POWER OPERATION
ITEM II- 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS
ITEM II- 1.19 CAR RIDE
II- 1.19.1 Acceptance
II- 1.19.2 References
202 Part II- 2 Machine Room or Space
ITEM II- 2.1 ACCESS TO EQUIPMENT SPACE
II- 2.1.1 Acceptance
II- 2.1.2 References
ITEM II- 2.2 HEADROOM
II- 2.2.1 Acceptance
II- 2.2.2 References
ITEM II- 2.3 LIGHTING AND RECEPTACLES
II- 2.3.1 Acceptance
II- 2.3.2 References
ITEM II- 2.4 MACHINE SPACE
II- 2.4.1 Acceptance
II- 2.4.2 References
ITEM II- 2.5 HOUSEKEEPING
II- 2.5.1 Acceptance
II- 2.5.2 References
ITEM II- 2.6 VENTILATION
ITEM II- 2.7 FIRE EXTINGUISHER
ITEM II- 2.8 PIPES, WIRING, AND DUCTS
II- 2.8.1 Acceptance
203 II- 2.8.2 References
ITEM II- 2.9 GUARDING OF SUSPENSION MEANS
II- 2.9.1 Acceptance
II- 2.9.2 References
ITEM II- 2.10 NUMBERING OF ELEVATORS, MACHINES, AND DISCONNNECT SWITCHES
ITEM II- 2.11 DISCONNECTING MEANS AND CONTROL
II- 2.11.1 Acceptance
II- 2.11.2 References
ITEM II- 2.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC.
II- 2.12.1 Acceptance
II- 2.12.2 References
ITEM II- 2.13 GOVERNOR
II- 2.13.1 Acceptance
II- 2.13.2 References
ITEM II- 2.14 DATA PLATE
II- 2.14.1 Acceptance
II- 2.14.2 References
204 ITEM II- 2.15 STATIC CONTROL
ITEM II- 2.16 OVERHEAD BEAM AND FASTENINGS
II- 2.16.1 Acceptance
II- 2.16.2 References
ITEM II- 2.17 DRIVE MACHINE BRAKE
II- 2.17.1 Acceptance
II- 2.17.2 References
ITEM II- 2.18 TRACTION DRIVE MACHINES
II- 2.18.1 Acceptance
II- 2.18.2 References
ITEM II- 2.19 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS
II- 2.19.1 Acceptance
II- 2.19.2 References
ITEM II- 2.20 WINDING DRUM MACHINE AND SLACK CABLE DEVICE
II- 2.20.1 Acceptance
II- 2.20.2 References
ITEM II- 2.21 CHAIN DRIVE MACHINE AND DRIVE SPROCKETS
II- 2.21.1 Acceptance
205 II- 2.21.2 References
ITEM II- 2.22 MOTOR GENERATOR
ITEM II- 2.23 ABSORPTION OF REGENERATED POWER
ITEM II- 2.24 AC DRIVES FROM A DC SOURCE
ITEM II- 2.25 TRACTION SHEAVES
II- 2.25.1 Acceptance
II- 2.25.2 References
ITEM II- 2.26 SECONDARY AND DEFLECTOR SHEAVES OR SPROCKETS
II- 2.26.1 Acceptance
II- 2.26.2 References
ITEM II- 2.27 ROPE FASTENINGS
II- 2.27.1 Acceptance
II- 2.27.2 References
ITEM II- 2.28 TERMINAL STOPPING DEVICES
II- 2.28.1 Acceptance
II- 2.28.2 References
ITEM II- 2.29 CAR AND COUNTERWEIGHT SAFETIES
II- 2.29.1 Acceptance
206 II- 2.29.2 References
ITEM II- 2.30 HYDRAULIC POWER UNIT
II- 2.30.1 Acceptance
II- 2.30.2 References
ITEM II- 2.31 RELIEF VALVES
II- 2.31.1 Acceptance
II- 2.31.2 References
ITEM II- 2.32 CONTROL VALVE
II- 2.32.1 Acceptance
II- 2.32.2 References
ITEM II- 2.33 TANKS
II- 2.33.1 Acceptance
II- 2.33.2 References
ITEM II- 2.34 FLEXIBLE HYDRAULIC HOSE AND FITTING ASSEMBLIES
II- 2.34.1 Acceptance
207 II- 2.34.2 References
ITEM II- 2.35 SUPPLY LINE AND SHUTOFF VALVE
II- 2.35.1 Acceptance
II- 2.35.2 References
ITEM II- 2.36 HYDRAULIC CYLINDERS
II- 2.36.1 Acceptance
II- 2.36.2 References
ITEM II- 2.37 PRESSURE SWITCH
II- 2.37.1 Acceptance
II- 2.37.2 References
ITEM II- 2.38 ROPED WATER HYDRAULIC ELEVATORS
ITEM II- 2.39 MANUAL OPERATION
II- 2.39.1 Acceptance
II- 2.39.2 References
ITEM II- 2.40 SLACK ROPE OR SLACK CHAIN DEVICES
II- 2.40.1 Acceptance
II- 2.40.2 References
208 Part II- 3 Top of Car
ITEM II- 3.1 TOP- OF- CAR STOP SWITCH
II- 3.1.1 Acceptance
II- 3.1.2 References
ITEM II- 3.2 CAR TOP LIGHT AND OUTLET
ITEM II- 3.3 TOP- OF- CAR OPERATING DEVICE
II- 3.3.1 Acceptance
II- 3.3.2 References
ITEM II- 3.4 TOP- OF- CAR CLEARANCE AND REFUGE SPACE
II- 3.4.1 Acceptance
II- 3.4.2 References
ITEM II- 3.5 NORMAL TERMINAL STOPPING DEVICE
II- 3.5.1 Acceptance
II- 3.5.2 References
ITEM II- 3.6 FINAL TERMINAL STOPPING DEVICES
II- 3.6.1 Acceptance
209 II- 3.6.2 References
ITEM II- 3.7 CAR LEVELING AND ANTICREEP DEVICES
II- 3.7.1 Acceptance
II- 3.7.2 References
ITEM II- 3.8 TOP EMERGENCY EXIT
ITEM II- 3.9 FLOOR AND EMERGENCY IDENTIFICATION NUMBERING
ITEM II- 3.10 HOISTWAY CONSTRUCTION
II- 3.10.1 Acceptance
II- 3.10.2 References
ITEM II- 3.11 HOISTWAY SMOKE CONTROL
ITEM II- 3.12 PIPES WIRING AND DUCTS
II- 3.12.1 Acceptance
II- 3.12.2 References
ITEM II- 3.13 WINDOWS PROJECTIONS, RECESSES, AND SETBACKS
II- 3.13.1 Acceptance
II- 3.13.2 References
ITEM II- 3.14 HOISTWAY CLEARANCE
II- 3.14.1 Acceptance
II- 3.14.2 References
ITEM II- 3.15 MULTIPLE HOISTWAYS
ITEM II- 3.16 TRAVELING CABLES AND JUNCTION BOXES
II- 3.16.1 Acceptance
II- 3.16.2 References
ITEM II- 3.17 DOOR AND GATE EQUIPMENT
II- 3.17.1 Acceptance
II- 3.17.2 References
210 ITEM II- 3.18 CAR FRAME AND STILES
II- 3.18.1 Acceptance
II- 3.18.2 References
ITEM II- 3.19 GUIDE RAIL FASTENING AND EQUIPMENT
II- 3.19.1 Acceptance
II- 3.19.2 References
ITEM II- 3.20 GOVERNOR ROPE
II- 3.20.1 Acceptance
II- 3.20.2 References
ITEM II- 3.21 GOVERNOR- RELEASING CARRIER
ITEM II- 3.22 WIRE ROPE OR CHAIN FASTENING AND HITCH PLATE
II- 3.22.1 Acceptance
II- 3.22.2 References
ITEM II- 3.23 SUSPENSION ROPE OR CHAIN
II- 3.23.1 Acceptance
II- 3.23.2 References
ITEM II- 3.24 TOP COUNTERWEIGHT CLEARANCE
ITEM II- 3.25 CAR, OVERHEAD, AND DEFLECTOR SHEAVES
II- 3.25.1 Acceptance
II- 3.25.2 References
ITEM II- 3.26 BROKEN ROPE, CHAIN, OR TAPE SELECTOR SWITCH
ITEM II- 3.27 DATA PLATE
II- 3.27.1 Acceptance
II- 3.27.2 References
ITEM II- 3.28 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER
II- 3.28.1 Acceptance
II- 3.28.2 References
211 ITEM II- 3.29 COUNTERWEIGHT SAFETIES
II- 3.29.1 Acceptance
II- 3.29.2 References
ITEM II- 3.30 SPEED TEST
II- 3.30.1 Acceptance
II- 3.30.2 References
Part II- 4 Outside Hoistway
ITEM II- 4.1 CAR PLATFORM GUARD
II- 4.1.1 Acceptance
II- 4.1.2 References
ITEM II- 4.2 HOISTWAY DOORS
II- 4.2.1 Acceptance
ITEM II- 3.31 SLACK ROPE OR SLACK CHAIN DEVICE
II- 3.31.1 Acceptance
II- 3.31.2 References
ITEM II- 3.32 TRAVELING SHEAVE
ITEM II- 3.33 COMPENSATING ROPES OR CHAINS
II- 4.2.2 References
ITEM II- 4.3 VISION PANELS
ITEM II- 4.4 HOISTWAY DOOR- LOCKING DEVICES
II- 4.4.1 Acceptance
212 II- 4.4.2 References
ITEM II- 4.5 ACCESS TO HOISTWAY
II- 4.5.1 Acceptance
II- 4.5.2 References
ITEM II- 4.6 POWER CLOSING OF HOISTWAY DOORS
II- 4.6.1 Acceptance
II- 4.6.2 References
ITEM II- 4.7 SEQUENCE OPERATION
ITEM II- 4.8 HOISTWAY ENCLOSURE
II- 4.8.1 Acceptance
II- 4.8.2 References
ITEM II- 4.9 ELEVATOR PARKING DEVICES
ITEM II- 4.10 EMERGENCY DOORS IN BLIND HOISTWAYS
ITEM II- 4.11 SEPARATE COUNTERWEIGHT HOISTWAY
II- 4.11.1 Acceptance
II- 4.11.2 References
ITEM II- 4.12 STANDBY POWER SELECTION SWITCH
213 Part II- 5 Pit
ITEM II- 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
II- 5.1.1 Acceptance
II- 5.1.2 References
ITEM II- 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE
ITEM II- 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
ITEM II- 5.4 NORMAL TERMINAL STOPPING DEVICES
ITEM II- 5.5 TRAVELING CABLES
II- 5.5.1 Acceptance
II- 5.5.2 References
ITEM II- 5.6 GOVERNOR ROPE- TENSIONING DEVICE
II- 5.6.1 Acceptance
II- 5.6.2 References
ITEM II- 5.7 CAR FRAME AND PLATFORM
ITEM II- 5.8 CAR SAFETIES AND GUIDING MEMBERS
II- 5.8.1 Acceptance
II- 5.8.2 References
ITEM II- 5.9 BUFFER
II- 5.9.1 Acceptance
II- 5.9.2 References
ITEM II- 5.10 COMPENSATING CHAINS, ROPES, AND SHEAVES
ITEM II- 5.11 PLUNGER AND CYLINDER
II- 5.11.1 Acceptance
II- 5.11.2 References
214 ITEM II- 5.12 CAR BUFFER
ITEM II- 5.13 GUIDING MEMBERS
II- 5.13.1 Acceptance
II- 5.13.2 References
ITEM II- 5.14 SUPPLY PIPING
II- 5.14.1 Acceptance
II- 5.14.2 References
ITEM II- 5.15 OVERSPEED VALVE
II- 5.15.1 Acceptance
II- 5.15.2 References
215 MANDATORY APPENDIX III
GUIDE FOR INSPECTION OF PRIVATE RESIDENCE INCLINED ELEVATORS
FOREWORD
PREFACE
Part III- 1 Inside of Car
ITEM III- 1.1 DOOR- REOPENING DEVICE
III- 1.1.4 References
ITEM III- 1.2 STOP SWITCHES
III- 1.2.4 References
216 ITEM III- 1.3 OPERATING CONTROL DEVICES
III- 1.3.3 Acceptance
III- 1.3.4 References
ITEM III- 1.4 SILLS AND CAR FLOOR
ITEM III- 1.5 CAR LIGHTING
ITEM III- 1.6 CAR DOOR OR GATE
III- 1.6.3 Acceptance
III- 1.6.4 References
ITEM III- 1.7 CAR ENCLOSURE
III- 1.7.3 Acceptance
III- 1.7.4 References
ITEM III- 1.8 RATED LOAD, PLATFORM AREA, AND DATA PLATE
III- 1.8.3 Acceptance
III- 1.8.4 References
ITEM III- 1.9 CAR RIDE
III- 1.9.3 Acceptance
III- 1.9.4 References
217 Part III- 2 Machine Room
Part III- 3 Top of Car
Part III- 4 Outside Hoistway
ITEM III- 4.1 NORMAL TERMINAL STOPPING DEVICES
III- 4.1.3 Acceptance
III- 4.1.4 References
ITEM III- 4.2 FINAL TERMINAL STOPPING DEVICES
III- 4.2.3 Acceptance
III- 4.2.4 References
ITEM III- 4.3 HOISTWAY CONSTRUCTION
III- 4.3.3 Acceptance
III- 4.3.4 References
ITEM III- 4.4 HOISTWAY CLEARANCES
III- 4.4.3 Acceptance
III- 4.4.4 References
218 ITEM III- 4.5 CAR FRAMES AND CHASSIS
III- 4.5.3 Acceptance
III- 4.5.4 References
ITEM III- 4.6 GUIDE RAILS FASTENING AND EQUIPMENT
III- 4.6.3 Acceptance
III- 4.6.4 References
ITEM III- 4.7 WIRE ROPE AND FASTENING
III- 4.7.3 Acceptance
III- 4.7.4 References
ITEM III- 4.8 CAR, TRAVELING, AND DEFLECTOR SHEAVES
III- 4.8.3 Acceptance
III- 4.8.4 References
ITEM III- 4.9 COUNTERWEIGHT
III- 4.9.3 Acceptance
III- 4.9.4 References
ITEM III- 4.10 HOISTWAY DOORS OR GATES
III- 4.10.3 Acceptance
III- 4.10.4 References
ITEM III- 4.11 HOISTWAY DOOR- OR GATE- LOCKING DEVICES
III- 4.11.3 Acceptance
III- 4.11.4 References
219 NONMANDATORY APPENDIX A INSPECTION CHECKLISTS
Checklist for Electric Elevators
220 Checklist for Electric Elevators ( Cont’d)
221 Checklist for Electric Elevators ( Cont’d)
222 Checklist for Electric Elevators ( Cont’d)
223 Checklist for Electric Elevators ( Cont’d)
224 Checklist for Electric Elevators ( Cont’d)
225 Checklist for Electric Elevators ( Cont’d)
226 Checklist for Electric Elevators ( Cont’d)
227 Checklist for Electric Elevators ( Cont’d)
228 Checklist for Electric Elevators ( Cont’d)
229 Checklist for Hydraulic Elevators
230 Checklist for Hydraulic Elevators ( Cont’d)
231 Checklist for Hydraulic Elevators ( Cont’d)
232 Checklist for Hydraulic Elevators ( Cont’d)
233 Checklist for Hydraulic Elevators ( Cont’d)
234 Checklist for Hydraulic Elevators ( Cont’d)
235 Checklist for Hydraulic Elevators ( Cont’d)
236 Checklist for Hydraulic Elevators ( Cont’d)
237 Checklist for Hydraulic Elevators ( Cont’d)
238 Checklist for Hydraulic Elevators ( Cont’d)
239 Checklist for Escalators
240 Checklist for Escalators ( Cont’d)
241 Checklist for Escalators ( Cont’d)
242 Checklist for Moving Walks
243 Checklist for Moving Walks ( Cont’d)
244 Checklist for Moving Walks ( Cont’d)
245 NONMANDATORY APPENDIX B ACCEPTANCE CHECKLIST
Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators
246 Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d)
247 Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d)
248 Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d)
249 Acceptance Checklist for Firefighters’ Service ( A17.1– 2000 and B44- 00): Automatic Elevators ( Cont’d)
250 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators
251 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d)
252 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d)
253 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d)
254 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d)
255 Acceptance Checklist for Firefighters’ Service ( A17.1– 2002 and B44- 02): Automatic Elevators ( Cont’d)
256 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators
257 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
258 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
259 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
260 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
261 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
262 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
263 Acceptance Checklist for Firefighters’ Service ( A17.1– 2004 and B44- 04): Automatic Elevators ( Cont’d)
264 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators
265 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
266 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
267 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
268 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
269 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
270 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
271 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
272 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
273 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
274 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1– 2007 and B44- 07): Automatic Elevators ( Cont’d)
275 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators
276 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
277 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
278 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
279 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
280 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
281 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
282 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
283 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
284 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
285 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
286 Acceptance Checklist for Firefighters’ Operation and Emergency Signaling Devices ( A17.1- 2010 and B44- 10): Automatic and Nonautomatic Elevators ( Cont’d)
287 NONMANDATORY APPENDIX C GUIDELINES FOR B44.1/ A17.5– 2004
C- 1 GENERAL
C- 2 GUIDELINES FOR ELECTRICAL DEVICES REQUIRING LABELING/ MARKING
ASME A17.2 2012
$98.04