Shopping Cart

No products in the cart.

ASME A17.2 2023

$75.42

ASME A17.2-2023 Guide for Inspection of Elevators, Escalators, and Moving Walks

Published By Publication Date Number of Pages
ASME 2023 565
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Guide covers recommended inspection and testing procedures for electric and hydraulic elevators, escalators, and moving walks required to conform to the Safety Code for Elevators and Escalators, A17.1-1955 and later editions and The Safety Code for Existing Elevators and Escalators, A17.3. This Guide also addresses some requirements from editions of A17.1 prior to 1955. NOTE: This Guide may not reflect the latest requirements in the current A17.1 and A17.3 Codes.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
19 FOREWORD
22 ASME A17 COMMITTEE ROSTER
29 CORRESPONDENCE WITH THE A17 COMMITTEE
30 PREFACE
33 ASME A17.2-2023 SUMMARY OF CHANGES
36 Introduction
1 SCOPE
2 APPLICATION
37 3 QUALIFICATIONS OF INSPECTORS
4 PERSONAL SAFETY
5 DUTIES OF INSPECTORS
6 ARRANGEMENT FOR INSPECTION
7 RECOMMENDED EQUIPMENT
38 8 REFERENCE DOCUMENTS
39 Part 1 Elevator — Inside of Car
ITEM 1.1 DOOR REOPENING DEVICE
1.1.1 Periodic Inspections
1.1.2 Periodic Test
1.1.3 Acceptance
1.1.4 References
40 ITEM 1.2 STOP SWITCHES
1.2.1 Periodic Inspections
1.2.2 Periodic Test
1.2.3 Acceptance
1.2.4 References
ITEM 1.3 OPERATING CONTROL DEVICES
1.3.1 Periodic Inspections
41 1.3.2 Periodic Test
1.3.3 Acceptance
1.3.4 References
ITEM 1.4 SILLS AND CAR FLOOR
1.4.1 Periodic Inspections
42 1.4.2 Periodic Test
1.4.3 Acceptance
1.4.4 References
ITEM 1.5 CAR LIGHTING AND RECEPTACLES
1.5.1 Periodic Inspections
1.5.2 Periodic Test
1.5.3 Acceptance
43 1.5.4 References
ITEM 1.6 CAR EMERGENCY SIGNAL AND COMMUNICATION DEVICES
1.6.1 Periodic Inspections
44 1.6.2 Periodic Test: Category 1
1.6.3 Acceptance
1.6.4 References
ITEM 1.7 CAR DOOR OR GATE
1.7.1 Periodic Inspections
45 1.7.2 Periodic Test
1.7.3 Acceptance
1.7.4 References
ITEM 1.8 DOOR CLOSING FORCE
1.8.1 Periodic Inspections
1.8.2 Periodic Test: Category 1 (Annual) Test
1.8.3 Acceptance
1.8.4 References
46 ITEM 1.9 POWER CLOSING OF DOORS OR GATES
1.9.1 Periodic Inspections
1.9.2 Periodic Test
1.9.3 Acceptance
1.9.4 References
ITEM 1.10 POWER OPENING OF DOORS OR GATES
1.10.1 Periodic Inspections
1.10.2 Periodic Test
47 Figures
Figure 1.10.2-1 Door Operation Relative to Car Position
48 1.10.3 Acceptance
1.10.4 References
ITEM 1.11 CAR VISION PANELS AND GLASS CAR DOORS
1.11.1 Periodic Inspections
49 1.11.2 Periodic Test
1.11.3 Acceptance
1.11.4 References
ITEM 1.12 CAR ENCLOSURE
1.12.1 Periodic Inspections
50 1.12.2 Periodic Test
1.12.3 Acceptance
1.12.4 References
ITEM 1.13 EMERGENCY EXIT
1.13.1 Periodic Inspections
51 1.13.2 Periodic Test
1.13.3 Acceptance
1.13.4 References
ITEM 1.14 VENTILATION
1.14.1 Periodic Inspections
1.14.2 Periodic Test
1.14.3 Acceptance
1.14.4 References
ITEM 1.15 SIGNS AND OPERATING DEVICE SYMBOLS
1.15.1 Periodic Inspections
1.15.2 Periodic Test
1.15.3 Acceptance
1.15.4 References
52 ITEM 1.16 RATED LOAD, PLATFORM AREA, AND DATA PLATE
1.16.1 Periodic Inspections
1.16.2 Periodic Test
1.16.3 Acceptance
1.16.4 References
ITEM 1.17 STANDBY POWER OPERATION
1.17.1 Periodic Inspections
1.17.2 Periodic Test
53 1.17.3 Acceptance
1.17.4 References
ITEM 1.18 RESTRICTED OPENING OF CAR OR HOISTWAY DOORS
1.18.1 Periodic Inspections
54 1.18.2 Periodic Test
1.18.3 Acceptance
1.18.4 References
55 ITEM 1.19 CAR RIDE
1.19.1 Periodic Inspections
1.19.2 Periodic Test
1.19.3 Acceptance
1.19.4 References
ITEM 1.20 EARTHQUAKE INSPECTION AND TESTS (ELEVATOR SEISMIC REQUIREMENTS)
1.20.1 Periodic Inspections
1.20.2 Periodic Test
1.20.3 Acceptance
56 1.20.4 References
57 Part 2 Elevator — Machine Room
ITEM 2.1 ACCESS TO MACHINERY SPACE
2.1.1 Periodic Inspections
2.1.2 Periodic Test
2.1.3 Acceptance
2.1.4 References
ITEM 2.2 HEADROOM
2.2.1 Periodic Inspections
2.2.2 Periodic Test
2.2.3 Acceptance
58 2.2.4 References
ITEM 2.3 LIGHTING AND RECEPTACLES
2.3.1 Periodic Inspections
2.3.2 Periodic Test
2.3.3 Acceptance
2.3.4 References
59 ITEM 2.4 MACHINERY SPACE
2.4.1 Periodic Inspections
2.4.2 Periodic Test
2.4.3 Acceptance
2.4.4 References
ITEM 2.5 HOUSEKEEPING
2.5.1 Periodic Inspections
60 2.5.2 Periodic Test
2.5.3 Acceptance
2.5.4 References
ITEM 2.6 VENTILATION
2.6.1 Periodic Inspections
2.6.2 Periodic Test
2.6.3 Acceptance
2.6.4 References
61 ITEM 2. 7 FIRE EXTINGUISHER
2.7.1 Periodic Inspections
2.7.2 Periodic Test
2.7.3 Acceptance
2.7.4 References
ITEM 2.8 PIPES, WIRING, AND DUCTS
2.8.1 Periodic Inspections
2.8.2 Periodic Test
2.8.3 Acceptance
2.8.4 References
62 ITEM 2.9 GUARDING OF EXPOSED AUXILIARY EQUIPMENT
2.9.1 Periodic Inspections
2.9.2 Periodic Test
2.9.3 Acceptance
2.9.4 References
ITEM 2.10 NUMBERING OF ELEVATORS, MACHINES, CONTROLLERS, AND DISCONNECT SWITCHES
2.10.1 Periodic Inspections
2.10.2 Periodic Test
2.10.3 Acceptance
2.10.4 References
63 ITEM 2.11 DISCONNECTING MEANS AND CONTROL
2.11.1 Periodic Inspections
2.11.2 Periodic Test
2.11.3 Acceptance
64 2.11.4 References
ITEM 2.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC.
2.12.1 Periodic Inspections
2.12.2 Periodic Test
65 2.12.3 Acceptance
2.12.4 References
ITEM 2.13 GOVERNOR, OVERSPEED SWITCH, AND SEAL
2.13.1 Periodic Inspections
2.13.2 Periodic Test
67 Tables
Table 2.13.2.1-1 Governor Adjustment Settings
68 Figure 2.13.2.1-1 Dynamometer Connections for Testing the Pull-Through of Governor Jaws
69 2.13.3 Acceptance
70 2.13.4 References
71 ITEM 2.14 CODE DATA PLATE
2.14.1 Periodic Inspections
2.14.2 Periodic Test
2.14.3 Acceptance
2.14.4 References
ITEM 2.15 STATIC CONTROL
2.15.1 Periodic Inspections
2.15.2 Periodic Test
2.15.3 Acceptance
2.15.4 References
ITEM 2.16 OVERHEAD BEAM AND FASTENINGS
2.16.1 Periodic Inspections
2.16.2 Periodic Test
2.16.3 Acceptance
72 2.16.4 References
ITEM 2.17 DRIVE MACHINE BRAKE
2.17.1 Periodic Inspections
2.17.2 Periodic Test
2.17.3 Acceptance
73 2.17.4 References
ITEM 2.18 TRACTION-DRIVE MACHINES
2.18.1 Periodic Inspections
2.18.2 Periodic Test
2.18.3 Acceptance
74 2.18.4 References
ITEM 2.19 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS
2.19.1 Periodic Inspections
2.19.2 Periodic Test
2.19.3 Acceptance
2.19.4 References
ITEM 2.20 WINDING DRUM MACHINE AND SLACK ROPE DEVICE, STOP-MOTION SWITCH, AND ROPE FASTENING
2.20.1 Periodic Inspections
75 2.20.2 Periodic Test
2.20.3 Acceptance
2.20.4 References
76 ITEM 2.21 BELT- OR CHAIN-DRIVE MACHINE
2.21.1 Periodic Inspections
2.21.2 Periodic Test
2.21.3 Acceptance
2.21.4 References
ITEM 2.22 MOTOR GENERATOR
2.22.1 Periodic Inspections
2.22.2 Periodic Test
2.22.3 Acceptance Test of Generator Suicide Circuit
77 2.22.4 References
ITEM 2.23 ABSORPTION OF REGENERATED POWER
2.23.1 Periodic Inspections
2.23.2 Periodic Test
2.23.3 Acceptance
2.23.4 References
ITEM 2.24 AC DRIVES FROM A DC SOURCE
2.24.1 Periodic Inspections
2.24.2 Periodic Test
2.24.3 Acceptance
2.24.4 References
78 ITEM 2.25 TRACTION SHEAVES
2.25.1 Periodic Inspections
2.25.2 Periodic Test
2.25.3 Acceptance
2.25.4 References
ITEM 2.26 SECONDARY AND DEFLECTOR SHEAVES
2.26.1 Periodic Inspections
2.26.2 Periodic Test
2.26.3 Acceptance
2.26.4 References
79 ITEM 2.27 ROPE FASTENINGS
2.27.1 Periodic Inspections
2.27.2 Periodic Test
2.27.3 Acceptance
2.27.4 References
ITEM 2.28 TERMINAL STOPPING DEVICES
2.28.1 Periodic Inspections
2.28.2 Periodic Test
80 2.28.3 Acceptance
2.28.4 References
ITEM 2.29 CAR AND COUNTERWEIGHT SAFETIES
2.29.1 Periodic Inspections
2.29.2 Periodic Test
81 Table 2.29.2-1 Maximum Safety Rope Pullout
83 Table 2.29.2-2 Minimum and Maximum Stopping Distances for Type B Car Safeties With Rated Load, and Type B Counterweight Safeties With No Load in the Car
84 Table 2.29.2-3 Gradual Wedge Clamp Safety
Table 2.29.2-4 Flexible Guide Clamp Safety
85 Figure 2.29.2-1 Safety Marks on Guide Rails, Poor Illumination
Figure 2.29.2-2 Safety Marks on Guide Rails, Good Illumination
Table 2.29.2-5 Wedge Clamp Safety (Constant Retarding Force)
86 2.29.3 Acceptance Test of Governor and Safeties
2.29.4 References
ITEM 2.30 HYDRAULIC POWER UNIT
2.30.1 Periodic Inspections
2.30.2 Periodic Test
2.30.3 Acceptance
2.30.4 References
ITEM 2.31 RELIEF VALVES
2.31.1 Periodic Inspections
87 2.31.2 Periodic Test
2.31.3 Acceptance
2.31.4 References
ITEM 2.32 CONTROL VALVE
2.32.1 Periodic Inspections
2.32.2 Periodic Test
2.32.3 Acceptance
88 2.32.4 References
ITEM 2.33 TANKS
2.33.1 Periodic Inspections
2.33.2 Periodic Test
2.33.3 Acceptance
2.33.4 References
89 ITEM 2.34 FLEXIBLE HYDRAULIC HOSES AND FITTING ASSEMBLIES
2.34.1 Periodic Inspections
2.34.2 Periodic Test
2.34.3 Acceptance Test
2.34.4 References
ITEM 2.35 SUPPLY LINE AND SHUTOFF VALVE
2.35.1 Periodic Inspections
Table 2.34.3-1 Minimum Bend Radius for SAE 100R2 Hose
90 2.35.2 Periodic Test
2.35.3 Acceptance
2.35.4 References
ITEM 2.36 HYDRAULIC CYLINDERS
2.36.1 Periodic Inspections
2.36.2 Periodic Test
2.36.3 Acceptance
2.36.4 References
ITEM 2.37 PRESSURE SWITCH
2.37.1 Periodic Inspections
91 2.37.2 Periodic Test
2.37.3 Acceptance
2.37.4 References
ITEM 2.38 ROPED WATER HYDRAULIC ELEVATORS
2.38.1 Periodic Inspections
2.38.2 Periodic Test
2.38.3 Acceptance
2.38.4 References
ITEM 2.39 LOW OIL PROTECTION
2.39.1 Periodic Inspections
2.39.2 Periodic Test
2.39.3 Acceptance
2.39.4 References
ITEM 2.40 MAINTENANCE RECORDS
2.40.1 Periodic Inspections
92 2.40.2 Periodic Test
2.40.3 Acceptance
2.40.4 References
ITEM 2.41 HYDRAULIC CONTROL
2.41.1 Periodic Inspections
2.41.2 Periodic Test
2.41.3 Acceptance
2.41.4 References
ITEM 2.42 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
2.42.1 Periodic inspections
2.42.2 Periodic Test
2.42.3 Acceptance
93 2.42.4 References
ITEM 2.43 EMERGENCY BRAKE, ASCENDING CAR OVERSPEED, AND UNINTENDED CAR MOVEMENT PROTECTION
2.43.1 Periodic Inspections
2.43.2 Periodic Test
94 2.43.3 Acceptance
2.43.4 References
ITEM 2.44 AUXILIARY POWER LOWERING OPERATION
2.44.1 Periodic Inspections
2.44.2 Periodic Test
95 Table 2.43.3.1-1 Traction Elevator Brake Type, Function, and Performance
96 2.44.3 Acceptance
2.44.4 References
ITEM 2.45 INSPECTION OPERATION WITH OPEN DOOR CIRCUITS AND INSPECTION OPERATION HIERARCHY
2.45.1 Periodic Inspections
2.45.2 Periodic Test
2.45.3 Acceptance
2.45.4 References
Table 2.45.3-1 Operation Hierarchy
97 Part 3 Elevator — Top of Car
ITEM 3.1 TOP-OF-CAR STOP SWITCH
3.1.1 Periodic Inspections
3.1.2 Periodic Test
3.1.3 Acceptance
3.1.4 References
ITEM 3.2 CAR TOP LIGHT AND OUTLET
3.2.1 Periodic Inspections
3.2.2 Periodic Test
3.2.3 Acceptance
3.2.4 References
98 ITEM 3.3 TOP-OF-CAR OPERATING DEVICE
3.3.1 Periodic Inspections: Routine Inspections (for A17.1d-2000 and Earlier Editions); Periodic Inspections (for A17.1-2000 and Later Editions)
3.3.2 Periodic Test
3.3.3 Acceptance
3.3.4 References
ITEM 3.4 TOP-OF-CAR CLEARANCE, REFUGE SPACE, AND STANDARD RAILING
3.4.1 Periodic Inspections: Routine Inspections (for A17.1d-2000 and Earlier Editions); Periodic Inspections (for A17.1-2000 and Later Editions)
100 3.4.2 Periodic Test
3.4.3 Acceptance
3.4.4 References
Figure 3.4.1.2-1 Car Top Clearance and Runby (A17.1-1978 and Later Editions)
101 ITEM 3.5 NORMAL TERMINAL STOPPING DEVICES
3.5.1 Periodic Inspections
3.5.2 Periodic Test
3.5.3 Acceptance
3.5.4 References
102 ITEM 3.6 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
3.6.1 Periodic Inspections
3.6.2 Periodic Test
3.6.3 Acceptance
3.6.4 References
103 ITEM 3.7 CAR LEVELING AND ANTICREEP DEVICES
3.7.1 Periodic Inspections
3.7.2 Periodic Test
3.7.3 Acceptance
3.7.4 References
104 ITEM 3.8 TOP EMERGENCY EXIT
3.8.1 Periodic Inspections: Routine Inspections (for A17.1d-2000 and Earlier Editions); Periodic Inspections (for A17.1d-2000 and Later Editions)
3.8.2 Periodic Test
3.8.3 Acceptance
3.8.4 References
ITEM 3.9 FLOOR AND EMERGENCY IDENTIFICATION NUMBERING
3.9.1 Periodic Inspections
3.9.2 Periodic Test
3.9.3 Acceptance
3.9.4 References
105 ITEM 3.10 HOISTWAY CONSTRUCTION
3.10.1 Periodic Inspections
3.10.2 Periodic Test
3.10.3 Acceptance
3.10.4 References
ITEM 3.11 HOISTWAY SMOKE CONTROL
3.11.1 Periodic Inspections
3.11.2 Periodic Test
3.11.3 Acceptance
106 3.11.4 References
ITEM 3.12 PIPES, WIRING, AND DUCTS
3.12.1 Periodic Inspections
3.12.2 Periodic Test
3.12.3 Acceptance
3.12.4 References
ITEM 3.13 WINDOWS, PROJECTIONS, RECESSES, AND SETBACKS
3.13.1 Periodic Inspections
107 3.13.2 Periodic Test
3.13.3 Acceptance
3.13.4 References
ITEM 3.14 HOISTWAY CLEARANCES
3.14.1 Periodic Inspections
3.14.2 Periodic Test
3.14.3 Acceptance
Table 3.14.3-1 Horizontal Clearances
Table 3.14.3-2 Horizontal Distances
108 3.14.4 References
ITEM 3.15 MULTIPLE HOISTWAYS
3.15.1 Periodic Inspections
3.15.2 Periodic Test
3.15.3 Acceptance
3.15.4 References
ITEM 3.16 TRAVELING CABLES AND JUNCTION BOXES
3.16.1 Periodic Inspections
109 3.16.2 Periodic Test
3.16.3 Acceptance
3.16.4 References
ITEM 3.17 DOOR AND GATE EQUIPMENT
3.17.1 Periodic Inspections
Figure 3.16.1-1 Self-Tightening Grips
111 3.17.2 Periodic Test
3.17.3 Acceptance
3.17.4 References
ITEM 3.18 CAR FRAME AND STILES
3.18.1 Periodic Inspections
3.18.2 Periodic Test
3.18.3 Acceptance
3.18.4 References
112 ITEM 3.19 GUIDE RAILS, FASTENINGS, AND EQUIPMENT
3.19.1 Periodic Inspections
3.19.2 Periodic Test
3.19.3 Acceptance
3.19.4 References
ITEM 3.20 GOVERNOR ROPE
3.20.1 Periodic Inspections
113 3.20.2 Periodic Test
3.20.3 Acceptance
3.20.4 References
ITEM 3.21 GOVERNOR RELEASING CARRIER
3.21.1 Periodic Inspections
3.21.2 Periodic Test: 5-yr Test (for A17.1d-2000 and Earlier Editions); Category 5 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
3.21.3 Acceptance
3.21.4 References
ITEM 3.22 WIRE ROPE FASTENING AND HITCH PLATE
3.22.1 Periodic Inspections
114 Figure 3.22.1.1-1 Cross Section Through Tapered Rope Socket Showing Maximum and Minimum Projection of Loops Above Embedment Medium
Table 3.22.1.1-1 Projection of Rope Strands Above Embedment Medium for 6- and 8-Strand Ropes
115 3.22.2 Periodic Test
3.22.3 Acceptance
3.22.4 References
ITEM 3.23 SUSPENSION COMPENSATION AND GOVERNOR SYSTEMS
3.23.1 Periodic Inspections
117 Figure 3.23.1-1 Types of Lay
118 Figure 3.23.1-2 Cross Sections of Typical Wire Ropes
120 Figure 3.23.1-3 Inspection and Replacement of Steel Wire Ropes
121 3.23.2 Periodic Test
3.23.3 Acceptance
3.23.4 References
122 ITEM 3.24 TOP COUNTERWEIGHT CLEARANCE
3.24.1 Periodic Inspections
3.24.2 Periodic Test
3.24.3 Acceptance
3.24.4 References
ITEM 3.25 CAR, OVERHEAD, AND DEFLECTOR SHEAVES
3.25.1 Periodic Inspections
3.25.2 Periodic Test
3.25.3 Acceptance
3.25.4 References
ITEM 3.26 BROKEN ROPE, CHAIN, OR TAPE SWITCH
3.26.1 Periodic Inspections
3.26.2 Periodic Test
3.26.3 Acceptance
3.26.4 References
123 ITEM 3.27 CROSSHEAD DATA PLATE AND ROPE DATA TAGS
3.27.1 Periodic Inspections
3.27.2 Periodic Test
3.27.3 Acceptance
3.27.4 References
ITEM 3.28 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER
3.28.1 Periodic Inspections
124 3.28.2 Periodic Test
3.28.3 Acceptance
3.28.4 References
ITEM 3.29 COUNTERWEIGHT SAFETIES
3.29.1 Periodic Inspections
3.29.2 Periodic Test
3.29.3 Acceptance
3.29.4 References
125 ITEM 3.30 SPEED TEST
3.30.1 Periodic Inspections
3.30.2 Periodic Test
3.30.3 Acceptance
3.30.4 References
ITEM 3.31 SLACK ROPE DEVICE — ROPED HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b-1989 AND LATER EDITIONS
3.31.1 Periodic Inspections
3.31.2 Periodic Test
3.31.3 Acceptance
3.31.4 References
126 ITEM 3.32 TRAVELING SHEAVE — ROPED HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b-1989 AND LATER EDITIONS
3.32.1 Periodic Inspections
3.32.2 Periodic Test
3.32.3 Acceptance
3.32.4 References
ITEM 3.33 COMPENSATING ROPES AND CHAINS
3.33.1 Periodic Inspections
3.33.2 Periodic Test
3.33.3 Acceptance
3.33.4 References
ITEM 3.34 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
3.34.1 Periodic Inspection
127 3.34.2 Periodic Test
3.34.3 Acceptance
3.34.4 References
128 Part 4 Elevator — Outside Hoistway
ITEM 4.1 CAR PLATFORM GUARD
4.1.1 Periodic Inspections
4.1.2 Periodic Test
4.1.3 Acceptance
4.1.4 References
ITEM 4.2 HOISTWAY DOORS
4.2.1 Periodic Inspections
129 4.2.2 Periodic Test
4.2.3 Acceptance
4.2.4 References
Table 4.2.1-1 Maximum Allowable Opening for a Hoistway Door or Gate in the Closed Position
130 ITEM 4.3 VISION PANELS
4.3.1 Periodic Inspections
4.3.2 Periodic Test
4.3.3 Acceptance
4.3.4 References
ITEM 4.4 HOISTWAY DOOR-LOCKING DEVICES
4.4.1 Periodic Inspections
4.4.2 Periodic Test
4.4.3 Acceptance
4.4.4 References
131 ITEM 4.5 ACCESS TO HOISTWAY
4.5.1 Periodic Inspections
4.5.2 Periodic Test
4.5.3 Acceptance
4.5.4 References
ITEM 4.6 POWER CLOSING OF HOISTWAY DOORS
4.6.1 Periodic Inspections
4.6.2 Periodic Test
4.6.3 Acceptance
4.6.4 References
132 ITEM 4.7 SEQUENCE OPERATION
4.7.1 Periodic Inspections
4.7.2 Periodic Test
4.7.3 Acceptance
4.7.4 References
ITEM 4.8 HOISTWAY ENCLOSURE
4.8.1 Periodic Inspections
4.8.2 Periodic Test
4.8.3 Acceptance
4.8.4 References
ITEM 4.9 ELEVATOR PARKING DEVICES
4.9.1 Periodic Inspections
133 4.9.2 Periodic Test
4.9.3 Acceptance
4.9.4 References
ITEM 4.10 EMERGENCY DOORS IN BLIND HOISTWAYS
4.10.1 Periodic Inspections
4.10.2 Periodic Test
4.10.3 Acceptance
4.10.4 References
ITEM 4.11 SEPARATE COUNTERWEIGHT HOISTWAY
4.11.1 Periodic Inspections
4.11.2 Periodic Test
4.11.3 Acceptance
4.11.4 References
ITEM 4.12 STANDBY POWER SELECTION SWITCH
4.12.1 Periodic Inspections
134 4.12.2 Periodic Test: Yearly Test (for A17.1d-2000 and Earlier Editions); Category 1 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
4.12.3 Acceptance
4.12.4 References
ITEM 4.13 EQUIPMENT IN PUBLIC LOCATIONS
4.13.1 Periodic Inspections
4.13.2 Periodic Test
4.13.3 Acceptance
4.13.4 References
135 Part 5 Elevator — Pit
ITEM 5.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
5.1.1 Periodic Inspections
5.1.2 Periodic Test
5.1.3 Acceptance
136 5.1.4 References
ITEM 5.2 BOTTOM CLEARANCE, RUNBY, AND MINIMUM REFUGE SPACE
5.2.1 Periodic Inspections
5.2.2 Periodic Test
5.2.3 Acceptance
137 Figure 5.2.3.1-1 Bottom Car Clearance for Electric and Hydraulic Elevators
138 5.2.4 References
ITEM 5.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
5.3.1 Periodic Inspections
5.3.2 Periodic Test
139 5.3.3 Acceptance
5.3.4 References
ITEM 5.4 NORMAL TERMINAL STOPPING DEVICES
5.4.1 Periodic Inspections
5.4.2 Periodic Test
5.4.3 Acceptance
5.4.4 References
ITEM 5.5 TRAVELING CABLES
5.5.1 Periodic Inspections
5.5.2 Periodic Test
5.5.3 Acceptance
5.5.4 References
ITEM 5.6 GOVERNOR-ROPE TENSION DEVICES
5.6.1 Periodic Inspections
140 5.6.2 Periodic Test
5.6.3 Acceptance
5.6.4 References
ITEM 5.7 CAR FRAME AND PLATFORM
5.7.1 Periodic Inspections
5.7.2 Periodic Test
5.7.3 Acceptance
5.7.4 References
141 ITEM 5.8 CAR AND COUNTERWEIGHT SAFETIES AND GUIDING MEMBERS — INCLUDING ROPED HYDRAULIC ELEVATORS INSTALLED UNDER A17.1b-1989 AND LATER EDITIONS
5.8.1 Periodic Inspections
5.8.2 Periodic Test
142 5.8.3 Acceptance
5.8.4 References
ITEM 5.9 CAR AND COUNTERWEIGHT BUFFERS AND EMERGENCY TERMINAL SPEED-LIMITING DEVICES
5.9.1 Periodic Inspections
Figure 5.8.1.1-1 Safety Gripping Face and Guide Rail Minimum Clearance
143 5.9.2 Periodic Test
144 5.9.3 Acceptance
5.9.4 References
145 ITEM 5.10 COMPENSATING CHAINS, ROPES, AND SHEAVES
5.10.1 Periodic Inspections
5.10.2 Periodic Test
5.10.3 Acceptance
5.10.4 References
ITEM 5.11 PLUNGER AND CYLINDER
5.11.1 Periodic Inspections
5.11.2 Periodic Test
5.11.3 Acceptance
5.11.4 References
146 ITEM 5.12 (RESERVED)
ITEM 5.13 GUIDING MEMBERS
5.13.1 Periodic Inspections
5.13.2 Periodic Test
5.13.3 Acceptance
5.13.4 References
ITEM 5.14 SUPPLY PIPING
5.14.1 Periodic Inspections
5.14.2 Periodic Test
5.14.3 Acceptance
5.14.4 References
ITEM 5.15 OVERSPEED VALVE
5.15.1 Periodic Inspections
5.15.2 Periodic Test
5.15.3 Acceptance
147 5.15.4 References
ITEM 5.16 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
5.16.1 Periodic Inspections
5.16.2 Periodic Test
5.16.3 Acceptance
5.16.4 References
148 ITEM 5.17 PLUNGER GRIPPER
5.17.1 Periodic Inspections
5.17.2 Periodic Test
5.17.3 Acceptance
149 5.17.4 References
Table 5.17.3.2-1 Plunger Gripper Stopping Distances With Rated Load in the Car
150 Part 6 Elevator — Firefighters’ Service
ITEM 6.1 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS (A17.1b-1973 THROUGH A17.1b-1980)
6.1.1 Periodic Inspections
6.1.2 Periodic Test: Yearly Test (for A17.1d-2000 and Earlier Editions); Category 1 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
151 6.1.3 Acceptance
6.1.4 References
152 ITEM 6.2 OPERATION OF ELEVATORS UNDER FIRE AND OTHER EMERGENCY CONDITIONS (A17.1-1981 THROUGH A17.1b-1983)
6.2.1 Periodic Inspections
6.2.2 Periodic Test: Yearly Test (for A17.1d-2000 and Earlier Editions); Category 1 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
154 6.2.3 Acceptance
6.2.4 References
ITEM 6.3 FIREFIGHTERS’ SERVICE (A17.1-1984 THROUGH A17.1a-1988 and ASME A17.3)
6.3.1 Periodic Inspections
6.3.2 Periodic Test: Yearly Test (for A17.1d-2000 and Earlier Editions); Category 1 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
156 6.3.3 Acceptance
6.3.4 References
ITEM 6.4 FIREFIGHTERS’ SERVICE (A17.1b-1989 THROUGH A17.1d-2000)
6.4.1 Periodic Inspections
6.4.2 Periodic Test: Yearly Test (for A17.1d-2000 and Earlier Editions); Category 1 Test (for ASME A17.1-2000/CSA B44-00 and Later Editions)
157 Figure 6.4.2-1 Visual Signal
159 Figure 6.4.2-2 Phase I Instructions
Figure 6.4.2-3 Phase II Instructions (A17.1b-1989 Through A17.1b-1995)
160 6.4.3 Acceptance
6.4.4 References
Figure 6.4.2-4 Phase II Instructions (A17.1-1996 Through A17.1d-2000)
161 ITEM 6.5 ACCEPTANCE CHECKLIST FOR FIREFIGHTERS’ SERVICE (ASME A17.1-2000/CSA B44-00): AUTOMATIC ELEVATORS
6.5.1 Emergency Signaling Devices
6.5.2 Phase I Key Switch and Instructions
6.5.3 Phase II In-Car Switch and Instructions
6.5.4 Monthly Test
6.5.5 Phase I Operation While Running
162 6.5.6 Phase I Operation With Doors Open
6.5.7 Emergency Stop Switch and/or In-Car Stop Switch and Doors Closing
6.5.8 Stop Switches and Door Buttons
6.5.9 Fire-Alarm-Initiating Device and Operation
6.5.10 Fire-Alarm-Initiating Device and Phase I Switch
163 6.5.11 Phase II Key Switch and Sign
6.5.12 Phase II Switch in the “HOLD” Position
6.5.13 Phase II Switch in the “OFF” Position and Doors Closing: Power-Operated Horizontally and Vertically Sliding Doors
6.5.14 Removal From Phase II Operation
6.5.15 Power Disconnects Open
6.5.16 Top-of-Car Operating Device
6.5.17 Automatic Elevators With Attendant Operation
164 6.5.18 Elevators on Phase I and Phase II Operation, Prevention of Operation and Disabling Not Allowed
165 Part 7 Escalator — External
ITEM 7.1 GENERAL FIRE PROTECTION
7.1.1 Periodic Inspections
7.1.2 Periodic Test
7.1.3 Acceptance
7.1.4 References
ITEM 7.2 GEOMETRY
7.2.1 Periodic Inspections
7.2.2 Periodic Test
7.2.3 Acceptance
166 Figure 7.2.1-1 Dimensions for Existing Escalators (for Escalators Installed Under A17.1-1955 and A17.1-1960 Editions)
167 Figure 7.2.1-2 Dimensions for Existing Escalators (for Escalators Installed Under A17.1-1965 Through A17.1-1981)
168 Figure 7.2.1-3 Relationship of Escalator Parts (for Escalators Installed Under A17.1a-1982 and Later Editions)
Figure 7.2.3-1 Checking Incline
169 7.2.4 References
ITEM 7.3 HANDRAILS
7.3.1 Periodic Inspections
7.3.2 Periodic Test
7.3.3 Acceptance
7.3.4 References
ITEM 7.4 ENTRANCE AND EGRESS ENDS
7.4.1 Periodic Inspections
7.4.2 Periodic Test
7.4.3 Acceptance
170 7.4.4 References
ITEM 7.5 LIGHTING
7.5.1 Periodic Inspections
7.5.2 Periodic Test
7.5.3 Acceptance
7.5.4 References
ITEM 7.6 CAUTION SIGNS
7.6.1 Periodic Inspections
7.6.2 Periodic Test
7.6.3 Acceptance
7.6.4 References
Figure 7.4.1-1 Safety Zone
171 ITEM 7.7 COMBPLATE AND COMB STEP IMPACT DEVICE
7.7.1 Periodic Inspections
7.7.2 Periodic Test
Figure 7.7.1-1 Checking Step/Combplate Mesh
172 7.7.3 Acceptance
7.7.4 References
Figure 7.7.3-1 Test of Combplate/Landing Plate Assembly
173 ITEM 7.8 DECK BARRICADES AND ANTISLIDE DEVICES
7.8.1 Periodic Inspections
7.8.2 Periodic Test
7.8.3 Acceptance
7.8.4 References
ITEM 7.9 STEPS AND UPTHRUST DEVICE
7.9.1 Periodic Inspections
Figure 7.8.1-1 Deck Barricade
174 Figure 7.8.1-2 High-Deck Balustrade Antislide Devices
175 7.9.2 Periodic Test
7.9.3 Acceptance
7.9.4 References
ITEM 7.10 OPERATING AND SAFETY DEVICES
7.10.1 Periodic Inspections
176 Figure 7.9.1-1 Smooth Riser
177 Figure 7.9.1-2 Cleated Riser
Figure 7.9.1-3 Escalator Step Riser
178 Figure 7.9.1-4 Escalator Step Tread [A17.1-1955 Through A17.1-1990, Rule 802.5 (Requirement 6.1.3.5)]
Figure 7.9.3-1 Example of Two Flat Steps
179 7.10.2 Periodic Test
7.10.3 Acceptance
7.10.4 References
ITEM 7.11 SKIRT-OBSTRUCTION DEVICE
7.11.1 Periodic Inspections
7.11.2 Periodic Test
180 Figure 7.11.2-1 Typical Skirt-Obstruction Device
181 7.11.3 Acceptance
7.11.4 References
ITEM 7.12 (RESERVED)
ITEM 7.13 EGRESS RESTRICTION (ROLLING SHUTTER) DEVICE
7.13.1 Periodic Inspections
7.13.2 Periodic Test
7.13.3 Acceptance
7.13.4 References
ITEM 7.14 SPEED
7.14.1 Periodic Inspections
7.14.2 Periodic Test
7.14.3 Acceptance
7.14.4 References
ITEM 7.15 BALUSTRADES
7.15.1 Periodic Inspections
7.15.2 Periodic Test
182 7.15.3 Acceptance
7.15.4 References
ITEM 7.16 CEILING INTERSECTION GUARDS
7.16.1 Periodic Inspections
7.16.2 Periodic Test
7.16.3 Acceptance
Figure 7.16.1-1 Ceiling or Soffit Guard [Requirements 6.1.3.3.9 and 6.2.3.3.7 (Rules 802.3g and 902.3g)]
183 7.16.4 References
ITEM 7.17 STEP/SKIRT CLEARANCES, PANELS, AND PERFORMANCE INDEX
7.17.1 Periodic Inspections
7.17.2 Periodic Test
Figure 7.17.1-1 Measuring Gap Between Step and Skirt
184 7.17.3 Acceptance
Figure 7.17.2-1 Angle of Skirt Panel
185 7.17.4 References
ITEM 7.18 OUTDOOR PROTECTION
7.18.1 Periodic Inspections
7.18.2 Periodic Test
7.18.3 Acceptance
7.18.4 References
ITEM 7.19 MAINTENANCE RECORDS
7.19.1 Periodic Inspections
7.19.2 Periodic Test
7.19.3 Acceptance
7.19.4 References
ITEM 7.20 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
7.20.1 Periodic Inspections
7.20.2 Periodic Test
186 7.20.3 Acceptance
7.20.4 References
Figure 7.18.3-1 Escalator Cover Overlap
187 Part 8 Escalator — Internal
ITEM 8.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION
8.1.1 Periodic Inspections
8.1.2 Periodic Test
8.1.3 Acceptance
8.1.4 References
ITEM 8.2 MACHINERY SPACE STOP SWITCHES AND INSPECTION CONTROL
8.2.1 Periodic Inspections
188 8.2.2 Periodic Test
8.2.3 Acceptance
8.2.4 References
ITEM 8.3 CONTROLLER AND WIRING
8.3.1 Periodic Inspections
8.3.2 Periodic Test
8.3.3 Acceptance
8.3.4 References
189 ITEM 8.4 DRIVE MACHINE AND BRAKE
8.4.1 Periodic Inspections
8.4.2 Periodic Test
190 8.4.3 Acceptance
8.4.4 References
ITEM 8.5 SPEED GOVERNOR
8.5.1 Periodic Inspections
8.5.2 Periodic Test
8.5.3 Acceptance
8.5.4 References
ITEM 8.6 BROKEN DRIVE CHAIN DEVICE AND DISCONNECTED MOTOR SAFETY DEVICE
8.6.1 Periodic Inspections
8.6.2 Periodic Test
191 8.6.3 Acceptance
8.6.4 References
ITEM 8.7 REVERSAL STOP SWITCH
8.7.1 Periodic Inspections
8.7.2 Periodic Test
8.7.3 Acceptance
8.7.4 References
ITEM 8.8 BROKEN STEP CHAIN DEVICE
8.8.1 Periodic Inspections
8.8.2 Periodic Test
8.8.3 Acceptance
8.8.4 References
ITEM 8.9 STEP UPTHRUST DEVICE
8.9.1 Periodic Inspections
8.9.2 Periodic Test
192 8.9.3 Acceptance
8.9.4 References
ITEM 8.10 MISSING STEP DEVICE
8.10.1 Periodic Inspections
8.10.2 Periodic Test
8.10.3 Acceptance
8.10.4 References
ITEM 8.11 STEP LEVEL DEVICE
8.11.1 Periodic Inspections
8.11.2 Periodic Test
Figure 8.9.2-1 Typical Step Upthrust Device
193 8.11.3 Acceptance
8.11.4 References
ITEM 8.12 STEPS, STEP CHAINS, AND TRUSSES
8.12.1 Periodic Inspections
8.12.2 Periodic Test
Figure 8.12.2-1 Positioning of Steps for Inspection of Truss
194 8.12.3 Acceptance
8.12.4 References
ITEM 8.13 HANDRAIL SYSTEMS AND SAFETY DEVICES
8.13.1 Periodic Inspections
8.13.2 Periodic Test
195 8.13.3 Acceptance
8.13.4 References
ITEM 8.14 CODE DATA PLATE
8.14.1 Periodic Inspections
8.14.2 Periodic Test
8.14.3 Acceptance
8.14.4 References
ITEM 8.15 RESPONSE TO SMOKE DETECTORS
8.15.1 Periodic Inspections
8.15.2 Periodic Test
8.15.3 Acceptance
8.15.4 References
ITEM 8.16 STEP LATERAL DISPLACEMENT DEVICE
8.16.1 Periodic Inspections
8.16.2 Periodic Test
196 8.16.3 Acceptance
8.16.4 References
ITEM 8.17 INSPECTION CONTROL
8.17.1 Periodic Inspections
8.17.2 Periodic Test
8.17.3 Acceptance
8.17.4 References
ITEM 8.18 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
8.18.1 Periodic Inspections
8.18.2 Periodic Test
8.18.3 Acceptance
8.18.4 References
197 Part 9 Moving Walk — External
ITEM 9.1 GENERAL FIRE PROTECTION
9.1.1 Periodic Inspections
9.1.2 Periodic Test
9.1.3 Acceptance
9.1.4 References
ITEM 9.2 GEOMETRY
9.2.1 Periodic Inspections
9.2.2 Periodic Test
9.2.3 Acceptance
198 Figure 9.2.1-1 Moving Walk Geometry (for Moving Walks Installed Under A17.1-1965 Through A17.1b-1980)
199 Figure 9.2.1-2 Moving Walk Geometry (for Moving Walks Installed Under A17.1-1981 Through A17.1a-1991)
200 Figure 9.2.3-1 Maximum Treadway Angle
Table 9.2.3-1 Treadway Width (A17.1-1965 Through A17.1d-1970)
Table 9.2.3-2 Treadway Width (A17.1-1971 and Later Editions)
201 9.2.4 References
ITEM 9.3 HANDRAILS
9.3.1 Periodic Inspections
9.3.2 Periodic Test
9.3.3 Acceptance
9.3.4 References
ITEM 9.4 ENTRANCE AND EGRESS ENDS
9.4.1 Periodic Inspections
Table 9.2.3-3 Minimum Treadway Width
202 9.4.2 Periodic Test
9.4.3 Acceptance
9.4.4 References
ITEM 9.5 LIGHTING
9.5.1 Periodic Inspections
9.5.2 Periodic Test
9.5.3 Acceptance
9.5.4 References
ITEM 9.6 CAUTION SIGNS
9.6.1 Periodic Inspections
Figure 9.3.3-1 Moving Walk Handrail Extension (A17.1-1971 and Later Editions)
203 9.6.2 Periodic Test
9.6.3 Acceptance
9.6.4 References
ITEM 9.7 COMBPLATE AND COMB STEP IMPACT DEVICE
9.7.1 Periodic Inspections
9.7.2 Periodic Test
9.7.3 Acceptance
9.7.4 References
ITEM 9.8 DECK BARRICADES
9.8.1 Periodic Inspections
204 9.8.2 Periodic Test
9.8.3 Acceptance
9.8.4 References
ITEM 9.9 TREADWAYS
9.9.1 Periodic Inspections
9.9.2 Periodic Test
9.9.3 Acceptance
9.9.4 References
205 ITEM 9.10 OPERATING AND SAFETY DEVICES
9.10.1 Periodic Inspections
Figure 9.9.1-1 Moving Walk Treadway Slots
206 9.10.2 Periodic Test
9.10.3 Acceptance
9.10.4 References
ITEM 9.11 (RESERVED)
ITEM 9.12 (RESERVED)
ITEM 9.13 EGRESS RESTRICTION (ROLLING SHUTTER) DEVICE
9.13.1 Periodic Inspections
9.13.2 Periodic Test
9.13.3 Acceptance
9.13.4 References
ITEM 9.14 SPEED
9.14.1 Periodic Inspections
9.14.2 Periodic Test
9.14.3 Acceptance
9.14.4 References
Table 9.14.1-1 Treadway Speed (A17.1-1981 and Later Editions)
207 ITEM 9.15 BALUSTRADES
9.15.1 Periodic Inspections
9.15.2 Periodic Test
9.15.3 Acceptance
9.15.4 References
ITEM 9.16 CEILING INTERSECTION GUARDS
9.16.1 Periodic Inspections
Table 9.14.1-2 Treadway Speed at Point of Entrance or Exit (A17.1-1965 Through A17.1b-1980)
Table 9.14.1-3 Treadway Speed at Any Point on Treadway (A17.1-1965 Through A17.1b-1980)
208 9.16.2 Periodic Test
9.16.3 Acceptance
9.16.4 References
ITEM 9.17 SKIRT PANELS
9.17.1 Periodic Inspections
Figure 9.15.1-1 Treadway Clearances
209 9.17.2 Periodic Test
9.17.3 Acceptance
9.17.4 References
ITEM 9.18 OUTDOOR PROTECTION
9.18.1 Periodic Inspections
9.18.2 Periodic Test
9.18.3 Acceptance
9.18.4 References
ITEM 9.19 MAINTENANCE RECORDS
9.19.1 Periodic Inspections
9.19.2 Periodic Test
9.19.3 Acceptance
9.19.4 References
210 ITEM 9.20 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
9.20.1 Periodic Inspections
9.20.2 Periodic Test
9.20.3 Acceptance
9.20.4 References
211 Part 10 Moving Walk — Internal
ITEM 10.1 MACHINERY SPACE ACCESS, LIGHTING, RECEPTACLE, AND CONDITION
10.1.1 Periodic Inspections
10.1.2 Periodic Test
10.1.3 Acceptance
10.1.4 References
ITEM 10.2 STOP SWITCH AND INSPECTION CONTROL
10.2.1 Periodic Inspections
10.2.2 Periodic Test
212 10.2.3 Acceptance
10.2.4 References
ITEM 10.3 CONTROLLER AND WIRING
10.3.1 Periodic Inspections
10.3.2 Periodic Test
10.3.3 Acceptance
10.3.4 References
213 ITEM 10.4 DRIVE MACHINE AND BRAKE
10.4.1 Periodic Inspections
10.4.2 Periodic Test
214 10.4.3 Acceptance
10.4.4 References
ITEM 10.5 SPEED GOVERNOR
10.5.1 Periodic Inspections
10.5.2 Periodic Test
10.5.3 Acceptance
10.5.4 References
ITEM 10.6 BROKEN DRIVE CHAIN DEVICE AND DISCONNECTED MOTOR SAFETY DEVICE
10.6.1 Periodic Inspections
10.6.2 Periodic Test
215 10.6.3 Acceptance
10.6.4 References
ITEM 10.7 REVERSAL STOP SWITCH
10.7.1 Periodic Inspections
10.7.2 Periodic Test
10.7.3 Acceptance
10.7.4 References
ITEM 10.8 BROKEN TREADWAY DEVICE
10.8.1 Periodic Inspections
10.8.2 Periodic Test
10.8.3 Acceptance
10.8.4 References
ITEM 10.9 (RESERVED)
ITEM 10.10 MISSING PALLET DEVICE
10.10.1 Periodic Inspections
10.10.2 Periodic Test
216 10.10.3 Acceptance
10.10.4 References
ITEM 10.11 PALLET LEVEL DEVICE
10.11.1 Periodic Inspections
10.11.2 Periodic Test
10.11.3 Acceptance
10.11.4 References
ITEM 10.12 PALLETS, PALLET CHAINS, AND TRUSSES
10.12.1 Periodic Inspections
10.12.2 Periodic Test
10.12.3 Acceptance
217 10.12.4 References
ITEM 10.13 HANDRAIL SYSTEMS AND SAFETY DEVICES
10.13.1 Periodic Inspections
10.13.2 Periodic Test
218 10.13.3 Acceptance
10.13.4 References
ITEM 10.14 CODE DATA PLATE
10.14.1 Periodic Inspections
10.14.2 Periodic Test
10.14.3 Acceptance
10.14.4 References
ITEM 10.15 RESPONSE TO SMOKE DETECTORS
10.15.1 Periodic Inspections
10.15.2 Periodic Test
10.15.3 Acceptance
10.15.4 References
ITEM 10.16 INSPECTION CONTROL
10.16.1 Periodic Inspections
10.16.2 Periodic Test
10.16.3 Acceptance
219 10.16.4 References
ITEM 10.17 EARTHQUAKE INSPECTION AND TESTS (SEISMIC RISK ZONE 2 OR GREATER)
10.17.1 Periodic Inspections
10.17.2 Periodic Test
10.17.3 Acceptance
10.17.4 References
220 Part 11 Elevator — Machine-Room-Less (MRL)
ITEM 11.1 ACCESS TO MACHINE ROOM/MACHINERY SPACE/ CONTROL ROOM/CONTROL SPACE
11.1.1 Periodic Inspections
11.1.2 Periodic Test
11.1.3 Acceptance
11.1.4 References
ITEM 11.2 ACCESS DOOR AND OPENINGS
11.2.1 Periodic Inspections
11.2.2 Periodic Test
11.2.3 Acceptance
11.2.4 References
221 ITEM 11.3 ENCLOSURE OF ROOMS AND SPACES
11.3.1 Periodic Inspections
11.3.2 Periodic Test
11.3.3 Acceptance
11.3.4 References
ITEM 11.4 (RESERVED)
ITEM 11.5 MACHINE/CONTROL ROOMS CONTAINING OVERHEAD DRIVE MACHINES
11.5.1 Periodic Inspections
11.5.2 Periodic Test
11.5.3 Acceptance
11.5.4 References
ITEM 11.6 (RESERVED)
ITEM 11.7 DISCONNECTING MEANS
11.7.1 Periodic Inspections
11.7.2 Periodic Test
11.7.3 Acceptance
11.7.4 References
ITEM 11.8 REMOTE MACHINE ROOMS AND CONTROL ROOMS
11.8.1 Periodic Inspections
11.8.2 Periodic Test
11.8.3 Acceptance
11.8.4 References
222 ITEM 11.9 INSPECTION AND TEST PANELS
11.9.1 Periodic Inspections
11.9.2 Periodic Test
11.9.3 Acceptance
11.9.4 References
ITEM 11.10 (RESERVED)
ITEM 11.11 (RESERVED)
ITEM 11.12 TRACTION SHEAVES
11.12.1 Periodic Inspections
11.12.2 Periodic Test
11.12.3 Acceptance
11.12.4 References
ITEM 11.13 SECONDARY AND DEFLECTOR SHEAVES
11.13.1 Periodic Inspections
223 11.13.2 Periodic Test
11.13.3 Acceptance
11.13.4 References
ITEM 11.14 TERMINAL STOPPING DEVICES
11.14.1 Periodic Inspections
11.14.2 Periodic Test
11.14.3 Acceptance
11.14.4 References
ITEM 11.15 WORKING AREAS INSIDE THE HOISTWAY AND IN THE PIT
11.15.1 Periodic Inspections
11.15.2 Periodic Test
11.15.3 Acceptance
224 11.15.4 References
ITEM 11.16 LOCATION OF MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, CONTROL ROOMS, AND EQUIPMENT
11.16.1 Periodic Inspections
11.16.2 Periodic Test
11.16.3 Acceptance
11.16.4 References
ITEM 11.17 HYDRAULIC ELEVATORS — SHUTOFF/MANUAL LOWERING VALVES
11.17.1 Periodic Inspections
11.17.2 Periodic Test
11.17.3 Acceptance
11.17.4 References
ITEM 11.18 HYDRAULIC ELEVATORS — PRESSURE GAGE FITTINGS
11.18.1 Periodic Inspections
11.18.2 Periodic Test
11.18.3 Acceptance
11.18.4 References
225 ITEM 11.19 HYDRAULIC ELEVATORS — ATMOSPHERE STORAGE AND DISCHARGE TANKS
11.19.1 Periodic Inspections
11.19.2 Periodic Test
11.19.3 Acceptance
11.19.4 References
ITEM 11.20 HYDRAULIC ELEVATORS — PRESSURE PIPING
11.20.1 Periodic Inspections
11.20.2 Periodic Test
11.20.3 Acceptance
11.20.4 References
ITEM 11.21 EXPLANATORY FIGURES FOR DEFINITIONS OFELEVATOR MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, CONTROL ROOM, REMOTE MACHINE ROOM, OR REMOTE CONTROL ROOM
ITEM 11.22 INSPECTION OPERATION AND HOISTWAY ACCESS SWITCH OPERATION HIERARCHY
ITEM 11.23 MOTOR CONTROLLER NOT INSTALLED IN A MACHINE ROOM, CONTROL ROOM, CONTROSPACE, OR MACHINERY SPACE
11.23.1 Periodic Inspections
11.23.2 Periodic Test
11.23.3 Acceptance
11.23.4 References
226 Figure 11.21-1 Configuration A
Figure 11.21-2 Configuration B
Figure 11.21-3 Configuration C
Figure 11.21-4 Configuration D
227 Figure 11.21-5 Configuration E
Figure 11.21-6 Configuration F
228 Table 11.21-1 Definitions of Elevator Machinery Space, Machine Room, Control Space, Control Room, Remote Machine Room, or Remote Control Room
229 Table 11.22-1 Inspection Operation and Hoistway Access Switch Operation Hierarchy
230 Part 12 Dumbwaiter — Car
ITEM 12.1 DOOR REOPENING DEVICE
12.1.1 Periodic Inspections
12.1.2 Periodic Test
12.1.3 Acceptance
12.1.4 References
ITEM 12.2 OPERATING CONTROL DEVICES
12.2.1 Periodic Inspections
12.2.2 Periodic Test
12.2.3 Acceptance
12.2.4 References
ITEM 12.3 SILLS AND CAR FLOOR
12.3.1 Periodic Inspections
12.3.2 Periodic Test
12.3.3 Acceptance
231 12.3.4 References
ITEM 12.4 CAR LIGHTING
12.4.1 Periodic Inspections
12.4.2 Periodic Test
12.4.3 Acceptance
12.4.4 References
ITEM 12.5 CAR DOOR OR GATE
12.5.1 Periodic Inspections
12.5.2 Periodic Test
12.5.3 Acceptance
12.5.4 References
ITEM 12.6 POWER CLOSING OF DOORS OR GATES
12.6.1 Periodic Inspections
12.6.2 Periodic Test
12.6.3 Acceptance
12.6.4 References
ITEM 12.7 POWER OPENING OF DOORS OR GATES
12.7.1 Periodic Inspections
12.7.2 Periodic Test
12.7.3 Acceptance
12.7.4 References
232 ITEM 12.8 CAR VISION PANELS
12.8.1 Periodic Inspections
12.8.2 Periodic Test
12.8.3 Acceptance
12.8.4 References
ITEM 12.9 CAR ENCLOSURE
12.9.1 Periodic Inspections
12.9.2 Periodic Test
12.9.3 Acceptance
12.9.4 References
ITEM 12.10 SIGNS AND OPERATING DEVICE SYMBOLS
12.10.1 Periodic Inspections
12.10.2 Periodic Test
12.10.3 Acceptance
12.10.4 References
ITEM 12.11 RATED LOAD, PLATFORM VOLUME, AND DATA CAPACITY PLATE
12.11.1 Periodic Inspections
12.11.2 Periodic Test
12.11.3 Acceptance
12.11.4 References
ITEM 12.12 CAR RIDE
12.12.1 Periodic Inspections
12.12.2 Periodic Test
12.12.3 Acceptance
12.12.4 References
233 Part 13 Dumbwaiter — Machinery Space, Machine Room, Control Space, and Control Room
ITEM 13.1 ACCESS TO EQUIPMENT SPACE
13.1.1 Periodic Inspections
13.1.2 Periodic Test
13.1.3 Acceptance
13.1.4 References
ITEM 13.2 HEADROOM
13.2.1 Periodic Inspections
13.2.2 Periodic Test
13.2.3 Acceptance
13.2.4 References
ITEM 13.3 LIGHTING AND RECEPTACLES
13.3.1 Periodic Inspections
13.3.2 Periodic Test
13.3.3 Acceptance
13.3.4 References
ITEM 13.4 MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, AND CONTROL ROOM
13.4.1 Periodic Inspections
13.4.2 Periodic Test
13.4.3 Acceptance
13.4.4 References
234 ITEM 13.5 HOUSEKEEPING
13.5.1 Periodic Inspections
13.5.2 Periodic Test
13.5.3 Acceptance
13.5.4 References
ITEM 13.6 VENTILATION
13.6.1 Periodic Inspections
13.6.2 Periodic Test
13.6.3 Acceptance
13.6.4 References
ITEM 13.7 FIRE EXTINGUISHER
13.7.1 Periodic Inspections
13.7.2 Periodic Test
13.7.3 Acceptance
13.7.4 References
ITEM 13.8 PIPES, WIRING, AND DUCTS
13.8.1 Periodic Inspections
13.8.2 Periodic Test
13.8.3 Acceptance
13.8.4 References
ITEM 13.9 GUARDING OF EQUIPMENT
13.9.1 Periodic Inspections
13.9.2 Periodic Test
13.9.3 Acceptance
13.9.4 References
235 ITEM 13.10 NUMBERING OF DUMBWAITERS, MACHINES, AND DISCONNECT SWITCHES
13.10.1 Periodic Inspections
13.10.2 Periodic Test
13.10.3 Acceptance
13.10.4 References
ITEM 13.11 DISCONNECTING MEANS AND CONTROL
13.11.1 Periodic Inspections
13.11.2 Periodic Test
13.11.3 Acceptance
13.11.4 References
ITEM 13.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC.
13.12.1 Periodic Inspections
13.12.2 Periodic Test
13.12.3 Acceptance — Inspection Made With Power Off
13.12.4 References
ITEM 13.13 GOVERNOR
13.13.1 Periodic Inspections
13.13.2 Periodic Test
13.13.3 Acceptance
13.13.4 References
236 ITEM 13.14 CODE DATA PLATE
13.14.1 Periodic Inspections
13.14.2 Periodic Test
13.14.3 Acceptance
13.14.4 References
ITEM 13.15 OVERHEAD BEAM AND FASTENINGS
13.15.1 Periodic Inspections
13.15.2 Periodic Test
13.15.3 Acceptance
13.15.4 References
ITEM 13.16 DRIVE MACHINE BRAKE
13.16.1 Periodic Inspections
13.16.2 Periodic Test
13.16.3 Acceptance
13.16.4 References
ITEM 13.17 TRACTION DRIVE MACHINES
13.17.1 Periodic Inspections
13.17.2 Periodic Test
13.17.3 Acceptance
13.17.4 References
ITEM 13.18 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS
13.18.1 Periodic Inspections
13.18.2 Periodic Test
13.18.3 Acceptance
13.18.4 References
237 ITEM 13.19 WINDING DRUM MACHINE
13.19.1 Periodic Inspections
13.19.2 Periodic Test
13.19.3 Acceptance
13.19.4 References
ITEM 13.20 CHAIN DRIVE MACHINE AND DRIVE SPROCKETS
13.20.1 Periodic Inspections
13.20.2 Periodic Test
13.20.3 Acceptance
13.20.4 References
ITEM 13.21 ABSORPTION OF REGENERATED POWER
13.21.1 Periodic Inspections
13.21.2 Periodic Test
13.21.3 Acceptance
13.21.4 References
ITEM 13.22 AC DRIVE FROM A DC SOURCE
13.22.1 Periodic Inspections
13.22.2 Periodic Test
13.22.3 Acceptance
238 13.22.4 References
ITEM 13.23 TRACTION SHEAVES
13.23.1 Periodic Inspections
13.23.2 Periodic Test
13.23.3 Acceptance
13.23.4 References
ITEM 13.24 SECONDARY AND DEFLECTOR SHEAVES OR SPROCKETS
13.24.1 Periodic Inspections
13.24.2 Periodic Test
13.24.3 Acceptance
13.24.4 References
ITEM 13.25 ROPE AND CHAIN FASTENINGS
13.25.1 Periodic Inspections
13.25.2 Periodic Test
13.25.3 Acceptance
13.25.4 References
ITEM 13.26 TERMINAL STOPPING DEVICES
13.26.1 Periodic Inspections
13.26.2 Periodic Test
13.26.3 Acceptance
13.26.4 References
239 ITEM 13.27 CAR AND COUNTERWEIGHT SAFETIES
13.27.1 Periodic Inspections
13.27.2 Periodic Test
13.27.3 Acceptance
13.27.4 References
ITEM 13.28 HYDRAULIC POWER UNIT
13.28.1 Periodic Inspections
13.28.2 Periodic Test
13.28.3 Acceptance
13.28.4 References
ITEM 13.29 RELIEF VALVES
13.29.1 Periodic Inspections
13.29.2 Periodic Test
13.29.3 Acceptance
13.29.4 References
240 ITEM 13.30 CONTROL VALVE
13.30.1 Periodic Inspections
13.30.2 Periodic Test
13.30.3 Acceptance
13.30.4 References
ITEM 13.31 TANKS
13.31.1 Periodic Inspections
13.31.2 Periodic Test
13.31.3 Acceptance
13.31.4 References
ITEM 13.32 FLEXIBLE HYDRAULIC HOSES AND FITTING ASSEMBLIES
13.32.1 Periodic Inspections
13.32.2 Periodic Test
13.32.3 Acceptance
13.32.4 References
ITEM 13.33 SUPPLY LINE AND SHUTOFF VALVE
13.33.1 Periodic Inspections
13.33.2 Periodic Test
13.33.3 Acceptance
13.33.4 References
ITEM 13.34 HYDRAULIC CYLINDERS
13.34.1 Periodic Inspections
13.34.2 Periodic Test
13.34.3 Acceptance
241 13.34.4 References
ITEM 13.35 PRESSURE SWITCH
13.35.1 Periodic Inspections
13.35.2 Periodic Test
13.35.3 Acceptance
13.35.4 References
ITEM 13.36 CONTROLS FOR HYDRAULIC AND ROPE OR CHAIN HYDRAULIC DUMBWAITERS
13.36.1 Periodic Inspections
13.36.2 Periodic Test
13.36.3 Acceptance
13.36.4 References
242 Part 14 Dumbwaiter — Top of Car
ITEM 14.1 TOP-OF-CAR SWITCH
14.1.1 Periodic Inspections
14.1.2 Periodic Test
14.1.3 Acceptance
14.1.4 References
ITEM 14.2 TOP-OF-CAR OPERATING DEVICE
14.2.1 Periodic Inspections
14.2.2 Periodic Test
14.2.3 Acceptance
14.2.4 References
ITEM 14.3 TOP-OF-CAR CLEARANCE AND REFUGE SPACE
14.3.1 Periodic Inspections
14.3.2 Periodic Test
14.3.3 Acceptance
14.3.4 References
ITEM 14.4 NORMAL TERMINAL STOPPING DEVICE
14.4.1 Periodic Inspections
14.4.2 Periodic Test
14.4.3 Acceptance
243 14.4.4 References
ITEM 14.5 FINAL TERMINAL STOPPING AND TERMINAL SPEED-REDUCING DEVICES
14.5.1 Periodic Inspections
14.5.2 Periodic Test
14.5.3 Acceptance
14.5.4 References
ITEM 14.6 CAR LEVELING AND ANTICREEP DEVICES
14.6.1 Periodic Inspections
14.6.2 Periodic Test
14.6.3 Acceptance
14.6.4 References
244 ITEM 14.7 HOISTWAY CONSTRUCTION
14.7.1 Periodic Inspections
14.7.2 Periodic Test
14.7.3 Acceptance
14.7.4 References
ITEM 14.8 PIPES, WIRING, AND DUCTS
14.8.1 Periodic Inspections
14.8.2 Periodic Test
14.8.3 Acceptance
14.8.4 References
ITEM 14.9 WINDOWS, PROJECTIONS, RECESSES, AND SETBACKS
14.9.1 Periodic Inspections
14.9.2 Periodic Test
14.9.3 Acceptance
14.9.4 References
ITEM 14.10 HOISTWAY CLEARANCE
14.10.1 Periodic Inspections
14.10.2 Periodic Test
14.10.3 Acceptance
14.10.4 References
ITEM 14.11 MULTIPLE HOISTWAYS
14.11.1 Periodic Inspections
14.11.2 Periodic Test
14.11.3 Acceptance
14.11.4 References
ITEM 14.12 TRAVELING CABLES AND JUNCTION BOXES
14.12.1 Periodic Inspections
14.12.2 Periodic Test
14.12.3 Acceptance
14.12.4 References
245 ITEM 14.13 DOOR AND GATE EQUIPMENT
14.13.1 Periodic Inspections
14.13.2 Periodic Test
14.13.3 Acceptance
14.13.4 References
ITEM 14.14 CAR FRAME AND STILES
14.14.1 Periodic Inspections
14.14.2 Periodic Test
14.14.3 Acceptance
14.14.4 References
ITEM 14.15 GUIDE RAILS, FASTENING, AND EQUIPMENT
14.15.1 Periodic Inspections
14.15.2 Periodic Test
14.15.3 Acceptance
14.15.4 References
ITEM 14.16 GOVERNOR ROPE
14.16.1 Periodic Inspections
14.16.2 Periodic Test
14.16.3 Acceptance
14.16.4 References
ITEM 14.17 WIRE ROPE OR CHAIN FASTENING AND HITCH PLATE
14.17.1 Periodic Inspections
14.17.2 Periodic Test
14.17.3 Acceptance
14.17.4 References
ITEM 14.18 SUSPENSION ROPE OR CHAIN
14.18.1 Periodic Inspections
14.18.2 Periodic Test
14.18.3 Acceptance
246 14.18.4 References
ITEM 14.19 TOP COUNTERWEIGHT CLEARANCE
14.19.1 Periodic Inspections
14.19.2 Periodic Test
14.19.3 Acceptance
14.19.4 References
ITEM 14.20 CAR, OVERHEAD, AND DEFLECTOR SHEAVES
14.20.1 Periodic Inspections
14.20.2 Periodic Test
14.20.3 Acceptance
14.20.4 References
ITEM 14.21 BROKEN ROPE, CHAIN, OR TAPE SELECTOR SWITCH
14.21.1 Periodic Inspections
14.21.2 Periodic Test
14.21.3 Acceptance
14.21.4 References
ITEM 14.22 DATA PLATES
14.22.1 Periodic Inspections
14.22.2 Periodic Test
14.22.3 Acceptance
14.22.4 References
ITEM 14.23 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER
14.23.1 Periodic Inspections
14.23.2 Periodic Test
14.23.3 Acceptance
14.23.4 References
247 ITEM 14.24 COUNTERWEIGHT SAFETY
14.24.1 Periodic Inspections
14.24.2 Periodic Test
14.24.3 Acceptance
14.24.4 References
ITEM 14.25 SPEED TEST
14.25.1 Periodic Inspections
14.25.2 Periodic Test
14.25.3 Acceptance
14.25.4 References
ITEM 14.26 SLACK ROPE OR SLACK CHAIN DEVICE
14.26.1 Periodic Inspections
14.26.2 Periodic Test
14.26.3 Acceptance
14.26.4 References
ITEM 14.27 TRAVELING SHEAVE
ITEM 14.28 COMPENSATING ROPES OR CHAINS
14.28.1 Periodic Inspections
14.28.2 Periodic Test
14.28.3 Acceptance
14.28.4 References
248 Part 15 Dumbwaiter — Outside Hoistway
ITEM 15.1 CAR GUARDS
15.1.1 Periodic Inspections
15.1.2 Periodic Test
15.1.3 Acceptance
15.1.4 References
ITEM 15.2 HOISTWAY DOORS
15.2.1 Periodic Inspections
15.2.2 Periodic Test
15.2.3 Acceptance
15.2.4 References
ITEM 15.3 VISION PANELS
15.3.1 Periodic Inspections
15.3.2 Periodic Test
15.3.3 Acceptance
15.3.4 References
ITEM 15.4 HOISTWAY DOOR-LOCKING DEVICES
15.4.1 Periodic Inspections
15.4.2 Periodic Test
15.4.3 Acceptance
249 15.4.4 References
ITEM 15.5 ACCESS TO HOISTWAY
15.5.1 Periodic Inspections
15.5.2 Periodic Test
15.5.3 Acceptance
15.5.4 References
ITEM 15.6 POWER CLOSING OF HOISTWAY DOORS
15.6.1 Periodic Inspections
15.6.2 Periodic Test
15.6.3 Acceptance
15.6.4 References
ITEM 15.7 HOISTWAY ENCLOSURE
15.7.1 Periodic Inspections
15.7.2 Periodic Test
15.7.3 Acceptance
15.7.4 References
ITEM 15.8 SEPARATE COUNTERWEIGHT HOISTWAY
15.8.1 Periodic Inspections
15.8.2 Periodic Test
15.8.3 Acceptance
15.8.4 References
250 Part 16 Dumbwaiter — Pit
ITEM 16.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
16.1.1 Periodic Inspections
16.1.2 Periodic Test
16.1.3 Acceptance
16.1.4 References
ITEM 16.2 BOTTOM CLEARANCE AND RUNBY
16.2.1 Periodic Inspections
16.2.2 Periodic Test
16.2.3 Acceptance
16.2.4 References
ITEM 16.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
ITEM 16.4 NORMAL TERMINAL STOPPING DEVICES
ITEM 16.5 TRAVELING CABLES
16.5.1 Periodic Inspections
16.5.2 Periodic Test
16.5.3 Acceptance
16.5.4 References
ITEM 16.6 GOVERNOR-ROPE TENSION DEVICE
16.6.1 Periodic Inspections
16.6.2 Periodic Test
16.6.3 Acceptance
16.6.4 References
ITEM 16.7 CAR FRAME AND PLATFORM
251 ITEM 16.8 CAR SAFETIES AND GUIDING MEMBERS
16.8.1 Periodic Inspections
16.8.2 Periodic Test
16.8.3 Acceptance
16.8.4 References
ITEM 16.9 BUFFER
16.9.1 Periodic Inspections
16.9.2 Periodic Test
16.9.3 Acceptance
16.9.4 References
ITEM 16.10 PLUNGER AND CYLINDER
16.10.1 Periodic Inspections
16.10.2 Periodic Test
16.10.3 Acceptance
16.10.4 References
ITEM 16.11 CAR BUFFER
ITEM 16.12 GUIDING MEMBERS
16.12.1 Periodic Inspections
16.12.2 Periodic Test
16.12.3 Acceptance
16.12.4 References
ITEM 16.13 SUPPLY PIPING
16.13.1 Periodic Inspections
16.13.2 Periodic Test
16.13.3 Acceptance
16.13.4 References
252 Part 17 Material Lift — Car
ITEM 17.1 DOOR REOPENING DEVICE
17.1.1 Periodic Inspection
17.1.2 Periodic Test
17.1.3 Acceptance
17.1.4 References
ITEM 17.2 STOP SWITCHES
17.2.1 Periodic Inspection
17.2.2 Periodic Test
17.2.3 Acceptance
17.2.4 References
ITEM 17.3 OPERATING CONTROL DEVICES
253 17.3.1 Periodic Inspection
17.3.2 Periodic Test
17.3.3 Acceptance
17.3.4 References
ITEM 17.4 SILLS AND CAR FLOOR
17.4.1 Periodic Inspection
17.4.2 Periodic Test
17.4.3 Acceptance
17.4.4 References
ITEM 17.5 CAR LIGHTING
17.5.1 Periodic Inspection
17.5.2 Periodic Test
17.5.3 Acceptance
17.5.4 References
ITEM 17.6 CAR DOOR OR GATE
17.6.1 Periodic Inspection
17.6.2 Periodic Test
17.6.3 Acceptance
17.6.4 References
254 ITEM 17.7 POWER CLOSING OF DOORS OR GATES
17.7.1 Periodic Inspection
17.7.2 Periodic Test
17.7.3 Acceptance
17.7.4 References
ITEM 17.8 POWER OPENING OF DOORS OR GATES
17.8.1 Periodic Inspection
17.8.2 Periodic Test
17.8.3 Acceptance
17.8.4 References
ITEM 17.9 CAR VISION PANELS
17.9.1 Periodic Inspection
17.9.2 Periodic Test
17.9.3 Acceptance
17.9.4 References
ITEM 17.10 CAR ENCLOSURE
17.10.1 Periodic Inspection
17.10.2 Periodic Test
17.10.3 Acceptance
17.10.4 References
255 ITEM 17.11 SIGNS AND OPERATING DEVICE SYMBOLS
17.11.1 Periodic Inspection
17.11.2 Periodic Test
17.11.3 Acceptance
17.11.4 References
ITEM 17.12 RATED LOAD, PLATFORM AREA, AND CAPACITY AND DATA PLATES
17.12.1 Periodic Inspection
17.12.2 Periodic Test
17.12.3 Acceptance
17.12.4 References
ITEM 17.13 CAR RIDE
17.13.1 Periodic Inspection
17.13.2 Periodic Test
17.13.3 Acceptance
17.13.4 References
256 Part 18 Material Lift — Machinery Spaces, Machine Rooms, Control Spaces, and Control Rooms
ITEM 18.1 ACCESS TO EQUIPMENT SPACE
18.1.1 Periodic Inspection
18.1.2 Periodic Test
18.1.3 Acceptance
18.1.4 References
ITEM 18.2 HEADROOM
18.2.1 Periodic Inspection
18.2.2 Periodic Test
18.2.3 Acceptance
18.2.4 References
ITEM 18.3 LIGHTING AND RECEPTACLES
18.3.1 Periodic Inspection
18.3.2 Periodic Test
18.3.3 Acceptance
257 18.3.4 References
ITEM 18.4 EQUIPMENT IN MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, AND CONTROL ROOMS
18.4.1 Periodic Inspection
18.4.2 Periodic Test
18.4.3 Acceptance
18.4.4 References
ITEM 18.5 HOUSEKEEPING
18.5.1 Periodic Inspection
18.5.2 Periodic Test
18.5.3 Acceptance
18.5.4 References
ITEM 18.6 VENTILATION
18.6.1 Periodic Inspection
18.6.2 Periodic Test
18.6.3 Acceptance
18.6.4 References
ITEM 18.7 FIRE EXTINGUISHER
18.7.1 Periodic Inspection
258 18.7.2 Periodic Test
18.7.3 Acceptance
18.7.4 References
ITEM 18.8 PIPES, WIRING, AND DUCTS
18.8.1 Periodic Inspection
18.8.2 Periodic Test
18.8.3 Acceptance
18.8.4 References
ITEM 18.9 GUARDING OF EQUIPMENT
18.9.1 Periodic Inspection
18.9.2 Periodic Test
18.9.3 Acceptance
18.9.4 References
ITEM 18.10 NUMBERING OF MATERIAL LIFTS, MACHINES, AND DISCONNNECT SWITCHES
18.10.1 Periodic Inspection
18.10.2 Periodic Test
18.10.3 Acceptance
18.10.4 References
ITEM 18.11 DISCONNECTING MEANS AND CONTROL
18.11.1 Periodic Inspection
18.11.2 Periodic Test
18.11.3 Acceptance
259 18.11.4 References
ITEM 18.12 CONTROLLER WIRING, FUSES, GROUNDING, ETC.
18.12.1 Periodic Inspection
18.12.2 Periodic Test
18.12.3 Acceptance
18.12.4 References
260 ITEM 18.13 GOVERNOR
18.13.1 Periodic Inspection
18.13.2 Periodic Test
261 18.13.3 Acceptance
18.13.4 References
ITEM 18.14 CODE DATA PLATE
18.14.1 Periodic Inspection
18.14.2 Periodic Test
18.14.3 Acceptance
18.14.4 References
ITEM 18.15 OVERHEAD BEAM AND FASTENINGS
18.15.1 Periodic Inspection
18.15.2 Periodic Test
18.15.3 Acceptance
18.15.4 References
ITEM 18.16 DRIVE MACHINE BRAKE
18.16.1 Periodic Inspection
262 18.16.2 Periodic Test
18.16.3 Acceptance
18.16.4 References
ITEM 18.17 TRACTION DRIVE MACHINES AND SHEAVE
18.17.1 Periodic Inspection
18.17.2 Periodic Test
18.17.3 Acceptance
18.17.4 References
ITEM 18.18 GEARS, BEARINGS, AND FLEXIBLE COUPLINGS
18.18.1 Periodic Inspection — Electric Material Lifts
263 18.18.2 Periodic Test
18.18.3 Acceptance
18.18.4 References
ITEM 18.19 WINDING DRUM MACHINE
18.19.1 Periodic Inspection
18.19.2 Periodic Test
18.19.3 Acceptance
18.19.4 References
264 ITEM 18.20 CHAIN DRIVE MACHINE AND DRIVE SPROCKETS
18.20.1 Periodic Inspection
18.20.2 Periodic Test
18.20.3 Acceptance
18.20.4 References
ITEM 18.21 (RESERVED)
ITEM 18.22 (RESERVED)
ITEM 18.23 (RESERVED)
ITEM 18.24 SECONDARY AND DEFLECTOR SHEAVES OR SPROCKETS
18.24.1 Periodic Inspection
18.24.2 Periodic Test
18.24.3 Acceptance
18.24.4 References
ITEM 18.25 ROPE AND CHAIN FASTENINGS
18.25.1 Periodic Inspection
Figure 18.20.1-1 Link-Plate Wear
265 18.25.2 Periodic Test
18.25.3 Acceptance
18.25.4 References
ITEM 18.26 TERMINAL STOPPING DEVICES
18.26.1 Periodic Inspection — Electric Material Lifts
18.26.2 Periodic Test
18.26.3 Acceptance
18.26.4 References
ITEM 18.27 CAR AND COUNTERWEIGHT SAFETIES
18.27.1 Periodic Inspection
18.27.2 Periodic Test
266 18.27.3 Acceptance
18.27.4 References
ITEM 18.28 HYDRAULIC POWER UNIT
18.28.1 Periodic Inspection
18.28.2 Periodic Test
18.28.3 Acceptance
18.28.4 References
ITEM 18.29 RELIEF VALVES
18.29.1 Periodic Inspection
18.29.2 Periodic Test
18.29.3 Acceptance
18.29.4 References
267 ITEM 18.30 CONTROL VALVE
18.30.1 Periodic Inspection
18.30.2 Periodic Test
18.30.3 Acceptance
18.30.4 References
ITEM 18.31 TANKS
18.31.1 Periodic Inspection
18.31.2 Periodic Test
18.31.3 Acceptance
18.31.4 References
ITEM 18.32 FLEXIBLE HYDRAULIC HOSE AND FITTING ASSEMBLIES
18.32.1 Periodic Inspection
18.32.2 Periodic Test
18.32.3 Acceptance
268 18.32.4 References
ITEM 18.33 SUPPLY LINE AND SHUTOFF VALVE
18.33.1 Periodic Inspection
18.33.2 Periodic Test
18.33.3 Acceptance
18.33.4 References
ITEM 18.34 HYDRAULIC CYLINDERS
18.34.1 Periodic Inspection
18.34.2 Periodic Test
18.34.3 Acceptance
18.34.4 References
ITEM 18.35 PRESSURE SWITCH
18.35.1 Periodic Inspection
18.35.2 Periodic Test
269 18.35.3 Acceptance
18.35.4 References
ITEM 18.36 LOW OIL PROTECTION
18.36.1 Periodic Inspection
18.36.2 Periodic Test
18.36.3 Acceptance
18.36.4 References
ITEM 18.37 MAINTENANCE RECORDS
ITEM 18.38 CONTROLS FOR HYDRAULIC AND ROPE OR CHAIN HYDRAULIC MATERIAL LIFTS
18.38.1 Periodic Inspection
18.38.2 Periodic Test
18.38.3 Acceptance
18.38.4 References
270 Part 19 Material Lift — Top of Car
ITEM 19.1 TOP-OF-CAR STOP SWITCH
19.1.1 Periodic Inspection
19.1.2 Periodic Test
19.1.3 Acceptance
19.1.4 References
ITEM 19.2 TOP-OF-CAR OPERATING DEVICE — TYPE A MANDATORY, TYPE B OPTIONAL
19.2.1 Periodic Inspection
19.2.2 Periodic Test
19.2.3 Acceptance
19.2.4 References
ITEM 19.3 TOP-OF-CAR CLEARANCE
19.3.1 Periodic Inspection
19.3.2 Periodic Test
19.3.3 Acceptance
19.3.4 References
271 ITEM 19.4 NORMAL AND FINAL TERMINAL STOPPING DEVICE
19.4.1 Periodic Inspection
19.4.2 Periodic Test
19.4.3 Acceptance
19.4.4 References
ITEM 19.5 FINAL TERMINAL STOPPING AND TERMINAL SPEED REDUCING DEVICES
19.5.1 Periodic Inspection
19.5.2 Periodic Test
19.5.3 Acceptance
272 19.5.4 References
ITEM 19.6 CAR LEVELING AND ANTICREEP DEVICES
19.6.1 Periodic Inspection
19.6.2 Periodic Test
19.6.3 Acceptance
19.6.4 References
ITEM 19.7 HOISTWAY CONSTRUCTION
19.7.1 Periodic Inspection
19.7.2 Periodic Test
19.7.3 Acceptance
19.7.4 References
ITEM 19.8 PIPES, WIRING, AND DUCTS
19.8.1 Periodic Inspection
19.8.2 Periodic Test
19.8.3 Acceptance
19.8.4 References
273 ITEM 19.9 WINDOWS, PROJECTIONS, RECESSES, AND SETBACKS
19.9.1 Periodic Inspection
19.9.2 Periodic Test
19.9.3 Acceptance
19.9.4 References
ITEM 19.10 HOISTWAY CLEARANCE
19.10.1 Periodic Inspection
19.10.2 Periodic Test
19.10.3 Acceptance
19.10.4 References
ITEM 19.11 MULTIPLE HOISTWAYS
19.11.1 Periodic Inspection
19.11.2 Periodic Test
19.11.3 Acceptance
19.11.4 References
ITEM 19.12 TRAVELING CABLES AND JUNCTION BOXES
19.12.1 Periodic Inspection
19.12.2 Periodic Test
19.12.3 Acceptance
19.12.4 References
ITEM 19.13 DOOR AND GATE EQUIPMENT
19.13.1 Periodic Inspection
19.13.2 Periodic Test
19.13.3 Acceptance
19.13.4 References
ITEM 19.14 CAR FRAME AND STILES
19.14.1 Periodic Inspection
19.14.2 Periodic Test
19.14.3 Acceptance
274 19.14.4 References
ITEM 19.15 GUIDE RAIL FASTENING AND EQUIPMENT
19.15.1 Periodic Inspection
19.15.2 Periodic Test
19.15.3 Acceptance
19.15.4 References
ITEM 19.16 GOVERNOR ROPE
19.16.1 Periodic Inspection
19.16.2 Periodic Test
19.16.3 Acceptance
19.16.4 References
ITEM 19.17 WIRE ROPE OR CHAIN FASTENING AND HITCH PLATE
19.17.1 Periodic Inspection
19.17.2 Periodic Test
19.17.3 Acceptance
19.17.4 References
ITEM 19.18 SUSPENSION ROPE OR CHAIN
19.18.1 Periodic Inspection
19.18.2 Periodic Test
19.18.3 Acceptance
19.18.4 References
ITEM 19.19 TOP COUNTERWEIGHT CLEARANCE
19.19.1 Periodic Inspection
19.19.2 Periodic Test
19.19.3 Acceptance
19.19.4 References
ITEM 19.20 CAR, OVERHEAD, AND DEFLECTOR SHEAVES
19.20.1 Periodic Inspection
19.20.2 Periodic Test
19.20.3 Acceptance
275 19.20.4 References
ITEM 19.21 BROKEN ROPE, CHAIN, OR TAPE SELECTOR SWITCH
19.21.1 Periodic Inspection
19.21.2 Periodic Test
19.21.3 Acceptance
19.21.4 References
ITEM 19.22 DATA PLATES
19.22.1 Periodic Inspection
19.22.2 Periodic Test
19.22.3 Acceptance
19.22.4 References
ITEM 19.23 COUNTERWEIGHT AND COUNTERWEIGHT BUFFER
19.23.1 Periodic Inspection
19.23.2 Periodic Test
19.23.3 Acceptance
19.23.4 References
ITEM 19.24 COUNTERWEIGHT SAFETIES
19.24.1 Periodic Inspection
19.24.2 Periodic Test
19.24.3 Acceptance
19.24.4 References
ITEM 19.25 SPEED TEST
19.25.1 Periodic Inspection
19.25.2 Periodic Test
19.25.3 Acceptance
19.25.4 References
276 ITEM 19.26 SLACK ROPE OR SLACK CHAIN DEVICE
19.26.1 Periodic Inspection
19.26.2 Periodic Test
19.26.3 Acceptance
19.26.4 References
ITEM 19.27 TRAVELING SHEAVE
ITEM 19.28 COMPENSATING ROPES OR CHAINS
19.28.1 Periodic Inspection
19.28.2 Periodic Test
19.28.3 Acceptance
19.28.4 References
277 Part 20 Material Lift — Outside Hoistway
ITEM 20.1 CAR GUARDS
20.1.1 Periodic Inspection
20.1.2 Periodic Test
20.1.3 Acceptance
20.1.4 References
ITEM 20.2 HOISTWAY DOORS
20.2.1 Periodic Inspection
20.2.2 Periodic Test
20.2.3 Acceptance
20.2.4 References
ITEM 20.3 VISION PANELS
20.3.1 Periodic Inspection
20.3.2 Periodic Test
20.3.3 Acceptance
278 20.3.4 References
ITEM 20.4 HOISTWAY DOOR LOCKING DEVICES
20.4.1 Periodic Inspection
20.4.2 Periodic Test
20.4.3 Acceptance
20.4.4 References
ITEM 20.5 ACCESS TO HOISTWAY
20.5.1 Periodic Inspection
20.5.2 Periodic Test
20.5.3 Acceptance
20.5.4 References
ITEM 20.6 POWER CLOSING OF HOISTWAY DOORS
20.6.1 Periodic Inspection
20.6.2 Periodic Test
20.6.3 Acceptance
20.6.4 References
ITEM 20.7 SEQUENCE OPERATION
20.7.1 Periodic Inspection
20.7.2 Periodic Test
20.7.3 Acceptance
20.7.4 References
279 ITEM 20.8 HOISTWAY ENCLOSURE
20.8.1 Periodic Inspection
20.8.2 Periodic Test
20.8.3 Acceptance
20.8.4 References
ITEM 20.9 SEPARATE COUNTERWEIGHT HOISTWAY
20.9.1 Periodic Inspection
20.9.2 Periodic Test
20.9.3 Acceptance
20.9.4 References
280 Part 21 Material Lift — Pit
ITEM 21.1 PIT ACCESS, LIGHTING, STOP SWITCH, AND CONDITION
21.1.1 Periodic Inspection
21.1.2 Periodic Test
21.1.3 Acceptance
21.1.4 References
ITEM 21.2 BOTTOM CLEARANCE AND RUNBY
21.2.1 Periodic Inspection
21.2.2 Periodic Test
21.2.3 Acceptance
21.2.4 References
ITEM 21.3 FINAL AND EMERGENCY TERMINAL STOPPING DEVICES
ITEM 21.4 NORMAL TERMINAL STOPPING DEVICES
281 ITEM 21.5 TRAVELING CABLES
21.5.1 Periodic Inspection
21.5.2 Periodic Test
21.5.3 Acceptance
21.5.4 References
ITEM 21.6 GOVERNOR ROPE TENSIONING DEVICE
21.6.1 Periodic Inspection
21.6.2 Periodic Test
21.6.3 Acceptance
21.6.4 References
ITEM 21.7 CAR FRAME AND PLATFORM
ITEM 21.8 CAR SAFETIES AND GUIDING MEMBERS
21.8.1 Periodic Inspection
21.8.2 Periodic Test
21.8.3 Acceptance
21.8.4 References
ITEM 21.9 BUFFER
21.9.1 Periodic Inspection
21.9.2 Periodic Test
21.9.3 Acceptance
21.9.4 References
ITEM 21.10 COMPENSATING CHAINS, ROPES, AND SHEAVES
21.10.1 Periodic Inspection
282 21.10.2 Periodic Test
21.10.3 Acceptance
21.10.4 References
ITEM 21.11 PLUNGER AND CYLINDER
21.11.1 Periodic Inspection
21.11.2 Periodic Test
21.11.3 Acceptance
21.11.4 References
ITEM 21.12 CAR BUFFER
ITEM 21.13 GUIDING MEMBERS
21.13.1 Periodic Inspection
21.13.2 Periodic Test
21.13.3 Acceptance
21.13.4 References
ITEM 21.14 SUPPLY PIPING
21.14.1 Periodic Inspection
21.14.2 Periodic Test
21.14.3 Acceptance
21.14.4 References
283 MANDATORY APPENDICES
MANDATORY APPENDIX I GUIDE FOR INSPECTION OF INCLINED ELEVATORS
284 Part I-1 Inclined Elevator — Inside of Car
286 Figure I-1.16.3.3-1 Net Platform Area Measurements
287 Part I-2 Inclined Elevator — Machine Room
289 Figure I-2.13.2.3-1 Static Governor-Rope Drive
Figure I-2.13.2.3-2 Wheel-Driven Governor
Figure I-2.28.2.3-1 Retractable Sill
290 Part I-3 Inclined Elevator — Top-of-Car/Uphill Emergency Exit/End-Loading Top-of-Car Door
295 Part I-4 Inclined Elevator — Outside Hoistway
296 Figure I-4.1-1 Car Platform Guard
297 Part I-5 Inclined Elevator — Pit
299 Figure I-5.1.1.3-1 Pits and Work Spaces
Figure I-5.2.1.3-1 Refuge Space When Conformance to ASME A17.1/CSA B44, Requirement 2.4.1 Is Not Provided
300 Part I-6 Inclined Elevator — Firefighters’ Service
301 Table I-6-1 Additional Checklist for Inclined Elevators
303 MANDATORY APPENDIX II GUIDE FOR INSPECTION OF PRIVATE RESIDENCE ELECTRIC AND HYDRAULIC ELEVATORS
304 Part II-1 Private Residence Elevator — Inside of Car
306 Table II-1.7.3-1 Maximum Distance Between Hoistway Face of Landing Door and Car Door or Gate, Private Residence Elevator (ASME A17.1-2016/CSA B44-16 and Later Editions)
308 Part II-2 Private Residence Elevator — Machine Room or Machinery Space
315 Part II-3 Private Residence Elevator — Top of Car
319 Part II-4 Private Residence Elevator — Outside Hoistway
321 Part II-5 Private Residence Elevator — Pit
323 MANDATORY APPENDIX III GUIDE FOR INSPECTION OF PRIVATE RESIDENCE INCLINED ELEVATORS
324 Part III-1 Private Residence Inclined Elevators — Inside of Car
326 Part III-2 Private Residence Inclined Elevators — Machine Room
327 Part III-3 Private Residence Inclined Elevators — Top of Car
328 Part III-4 Private Residence Inclined Elevators — Outside Hoistway
330 NONMANDATORY APPENDICES
NONMANDATORY APPENDIX A INSPECTION CHECKLISTS
331 Table A-1 Checklist for Electric Elevators
346 Table A-2 Checklist for Hydraulic Elevators
360 Table A-3 Checklist for Escalators
364 Table A-4 Checklist for Moving Walks
367 NONMANDATORY APPENDIX B ACCEPTANCE CHECKLISTS
368 Table B-1
373 Table B-2
379 Table B-3
387 Table B-4
398 Table B-5
411 Table B-6
427 Table B-7
443 NONMANDATORY APPENDIX C GUIDELINES FOR CSA B44.1/ASME A17.5-2004
C-1 GENERAL
C-2 GUIDELINES FOR ELECTRICAL DEVICES REQUIRING LABELING/MARKING
445 NONMANDATORY APPENDIX D CHECKLISTS FOR ELECTRIC AND HYDRAULIC ELEVATORS, ESCALATORS, AND MOVING WALKS
D-1 CHECKLISTS BASED ON ASME A17.1-2013/CSA B44-13
D-2 CHECKLISTS BASED ON ASME A17.1-2019/CSA B44-19 and ASME A17.2-2020
446 Table D-1-1 Electric Elevator Checklist (Based on ASME A17.1-2013/CSA B44-13)
465 Table D-1-2 Hydraulic Elevator Checklist (Based on ASME A17.1-2013/CSA B44-13)
479 Table D-1-3 Escalator and Moving Walk Checklist (Based on ASME A17.1-2013/CSA B44-13 and ASME A17.3-2011)
485 Table D-2-1 Electric Elevator Checklist (Based on ASME A17.1-2019/CSA B44-19 and ASME A17.2-2020)
504 Table D-2-2 Hydraulic Elevator Checklist (Based on ASME A17.1-2019/CSA B44-19 and ASME A17.2-2020)
518 Table D-2-3 Escalator and Moving Walk Checklist (Based on ASME A17.1-2019/CSA B44-19 and ASME A17.2-2020)
524 NONMANDATORY APPENDIX E CHECKLISTS AND REPORTS FOR INSPECTION OF ELECTRIC AND HYDRAULIC ELEVATORS, ESCALATORS, AND MOVING WALKS
525 Forms
Form E-1 Checklist and Report for Inspection of Electric Elevators
526 Form E-2 Checklist and Report for Inspection of Hydraulic Elevators
527 Form E-3 Checklist and Report for Inspection of Escalators
528 Form E-4 Checklist and Report for Inspection of Moving Walks
529 NONMANDATORY APPENDIX F INSPECTION CHECKLISTS FOR LIMITED-USE/LIMITED-APPLICATION ELECTRIC AND HYDRAULIC ELEVATORS
530 Table F-1 Checklist for Electric LU/LA Elevators
538 Table F-2 Checklist for Hydraulic LU/LA Elevators
549 Table G-1 Guidelines for Mass and Closing Time of Elevator Horizontally Sliding Doors (See ASME A17.1/CSA B44, Requirements 2.13.4.2.4, 8.6.3.8, 8.6.4.19.8, and 8.6.5.14.6.)
NONMANDATORY APPENDIX G GUIDE FOR TYPICAL DOOR CLOSING TIMES
550 NONMANDATORY APPENDIX H EXAMPLES OF SUSPENSION MEMBER TENSION MEASUREMENT DATA AND CALCULATIONS FOR ADJUSTMENT
H-1 EXAMPLE 1: FIVE-SUSPENSION-MEMBER SYSTEM
H-2 EXAMPLE 2: SEVEN-SUSPENSION-MEMBER SYSTEM
551 NONMANDATORY APPENDIX I ACCEPTANCE CHECKLIST FOR OCCUPANT EVACUATION OPERATION (ASME A17.1-2013/CSA B44-13)
552 Table I-1 Acceptance Checklist for Occupant Evacuation Operation (ASME A17.1-2013/CSA B44-13)
559 NONMANDATORY APPENDIX J ACCEPTANCE CHECKLIST FOR STANDBY/EMERGENCY POWER
560 Table J-1 Acceptance Checklist for Standby Emergency Power
562 NONMANDATORY APPENDIX K CHECKLIST FOR SEISMIC REQUIREMENTS
563 Table K-1 Acceptance Checklist for Seismic Requirements — Hydraulic Elevators (ASME A17.1-2019/CSA B44-19)
ASME A17.2 2023