ASME AG 1 2019
$98.04
ASME AG-1-2019 Code on Nuclear Air and Gas Treatment
Published By | Publication Date | Number of Pages |
ASME | 2019 | 515 |
Provides requirements for the performance, design, construction, acceptance testing, and quality assurance of equipment used as components in nuclear safety-related air and gas treatment systems in nuclear facilities.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
37 | FOREWORD |
38 | COMMITTEE ROSTER |
44 | CORRESPONDENCE WITH THE COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT |
46 | ORGANIZATION OF ASME AG-1 |
48 | ASME AG-1-2019 SUMMARY OF CHANGES |
56 | Division I General Requirements SECTION AA COMMON ARTICLES AA-1100 SCOPE AA-1200 PURPOSE AA-1300 APPLICABILITY AA-1400 DEFINITIONS AND TERMS |
61 | AA-3100 GENERAL AA-3200 MATERIAL SUBSTITUTION AA-3300 MATERIAL TESTING AA-3400 CERTIFICATION OF MATERIALS AA-4100 SCOPE |
62 | Tables Table AA-3100-1 Allowable Materials |
66 | AA-4110 Environmental Qualification AA-4200 DESIGN CRITERIA AA-4210 Load Criteria |
67 | AA-4220 Stress Criteria: Limits AA-4230 Deflection Criteria: Limits AA-4240 Other Criteria Table AA-4212-1 Load Conditions Table AA-4230-1 Deflection Limits |
68 | AA-4300 DESIGN OF EQUIPMENT SYSTEMS AND THEIR SUPPORTING ELEMENTS AA-4310 General Requirements |
69 | AA-4320 Design Verification of Plate- and Shell-Type Components and Their Supporting Elements Table AA-4321-1 Plate- and Shell-Type Components: Primary Stress Allowables |
70 | AA-4330 Design Verification of Linear-Type Systems by Analysis Table AA-4323-1 Linear-Type Systems: Primary Stress Allowables |
71 | AA-4340 Functionality Requirements AA-4350 Design Verification by Seismic Qualification Testing |
74 | Figures Figure AA-4355.3-1 Sine Beat Frequency and Amplitude Figure AA-4355.4-1 Sine Amplitude Decay Rate |
75 | Figure AA-4356.4-1 Response Spectrum of Composite Excitation |
76 | AA-4360 Design of Bolts Figure AA-4356.4-2 Oscillations per Beat |
77 | AA-4400 DOCUMENTATION REQUIREMENTS AA-4410 Certification of Design Verification AA-4420 Equipment Description AA-4430 Safety-Related Features AA-4440 Report Content |
78 | AA-5100 GENERAL AA-5110 Scope and Applicability AA-5120 Responsibility for Procedures AA-5130 Measuring and Test Equipment AA-5200 VISUAL INSPECTION AA-5210 Scope AA-5220 Description of Method |
79 | AA-5230 Requirements AA-5240 Inspection Checklist AA-5250 Reports AA-5300 WELDED CONNECTIONS AA-5400 BOLTED CONNECTIONS AA-5410 Before Bolting AA-5420 After Bolting AA-5500 FABRICATION TOLERANCES AA-5600 PRESSURE AND LEAK TESTING AA-5700 PERFORMANCE AND FUNCTIONAL TESTING AA-5800 SEISMIC TESTING AA-6100 GENERAL AA-6110 Scope and Applicability AA-6120 Materials |
80 | AA-6130 Control of Fabrication and Installation Processes AA-6200 FABRICATION PROCESSES AA-6210 Cutting, Forming, and Bending AA-6220 Forming Tolerances AA-6230 Fitting and Aligning AA-6240 Welded Joints AA-6250 Mechanical Joints |
81 | AA-6300 WELDING REQUIREMENTS AA-6310 General |
82 | AA-6320 Workmanship AA-6330 Inspection and Testing of Welds |
83 | Figure AA-6324.2-1 Acceptable and Unacceptable Weld Profiles |
84 | AA-6400 BRAZING AA-6410 General AA-6420 Workmanship |
85 | AA-6430 Inspection and Testing AA-6500 CLEANING AND COATING AA-6510 General |
86 | AA-6520 Design Considerations for Coating AA-6530 Repair of Coating System AA-6540 Cleanliness |
88 | AA-6550 Quality Assurance Requirements and Documentation AA-6600 INSTALLATION REQUIREMENTS AA-6610 Handling and Rigging AA-6620 Field Assembly |
89 | AA-6630 Temporary Field Attachments AA-7100 GENERAL AA-7110 Scope and Applicability AA-7120 Responsibility AA-7200 GENERAL REQUIREMENTS AA-7210 Planning, Procedures, and Instructions AA-7220 Personnel Qualifications |
90 | AA-7230 Classification of Items AA-7300 PACKAGING AA-7310 General AA-7320 Level of Packaging AA-7400 SHIPPING AA-8100 GENERAL AA-8110 Scope and Applicability AA-8120 Responsibility AA-8130 Responsibilities of Fabricators, Material Suppliers, and Material Manufacturers |
91 | AA-8200 IDENTIFICATION AND CONTROL OF ITEMS AA-8210 Documentation AA-8220 Identification and Completed Material AA-8230 Marking Requirements for Small Products AA-8240 Certified Material Test Reports AA-8250 Records of Examinations and Tests Figure AA-8130-1 Hierarchy of Responsibility |
92 | AA-8300 QUALITY ASSURANCE RECORDS AA-9100 SCOPE AND APPLICABILITY AA-9200 REQUIREMENTS AA-9210 Attachment of Nameplates AA-9220 Location of Nameplates AA-10100 GENERAL AA-10110 Scope AA-10120 Applicability |
93 | AA-10200 WELDING AA-10300 REPAIRS AA-10400 REPLACEMENTS AA-10410 Routine Maintenance AA-10420 Suitability AA-10430 Additional Documentation |
94 | AA-10500 RECORDS AA-10510 General Requirements AA-10520 Records Index AA-10530 Lifetime Records AA-10540 Nonpermanent Records Table AA-10530-1 Lifetime Repair and Replacement Records Table AA-10540-1 Nonpermanent Repair and Replacement Records |
95 | NONMANDATORY APPENDIX AA-A DESIGN AND QUALIFICATION BY ANALYSIS Table AA-A-1000-1 Analysis Considerations |
96 | AA-A-4100 AIR HANDLING UNIT (AHU) MODEL |
97 | AA-A-4200 FAN MODEL AA-A-4300 INSTRUMENTS AND CONTROLS (I & C) CABINETS AA-A-4400 DUCT SUPPORTS AA-A-4500 EQUIPMENT SUPPORTS AA-A-5100 STATIC LOADS |
98 | Figure AA-A-4200-1 Isometric View of a Typical Fan Model |
99 | Figure AA-A-4300-1 Isometric View of a Typical I & C Cabinet Model |
100 | Figure AA-A-4400-1 Isometric View of a Typical Duct Support Model |
101 | AA-A-5200 DYNAMIC ANALYSIS AA-A-5210 Dynamic Loads AA-A-5220 Dynamic Analysis Techniques AA-A-5230 Input Motion Figure AA-A-4500-1 Isometric View of a Typical Refrigeration Equipment Support |
102 | AA-A-5240 Two-Step Analysis AA-A-6100 STRESSES AA-A-6200 DEFLECTIONS AA-A-6210 Linear AA-A-6220 Nonlinear AA-A-6300 SUPPORT LOADS AA-A-6400 CONNECTION LOADING AA-A-6500 DEVICE LOADING AA-A-7100 SCOPE AA-A-7200 SAMPLE AHU ANALYSIS |
103 | Figure AA-A-7200-1 Computer Plots of Finite Element Model of Sample AHU (Perspective View of Tri-Plate Mesh) |
105 | AA-A-7300 DUCT SUPPORT (HANGER) SAMPLE PROBLEM AA-A-7310 Hanger Model AA-A-7320 Analysis |
107 | Figure AA-A-7310-1 Typical Duct Support As-Built (Dimensions and Member Sizes Not Shown) |
108 | Figure AA-A-7311-1 Ductwork Support Baseplate Model |
109 | Figure AA-A-7324-1 Effective Duct Cross Section |
110 | Figure AA-A-7325-1 Typical Duct System Model |
111 | NONMANDATORY APPENDIX AA-B SEISMIC QUALIFICATION BY TESTING AA-B-2100 PURPOSE AA-B-2200 SCOPE AA-B-2300 TEST SPECIMENS AA-B-2400 SPECIAL EQUIPMENT OR FIXTURES (IF REQUIRED) AA-B-2500 TEST SETUP AA-B-2600 TEST REQUIREMENTS AA-B-2700 ACCEPTANCE/FAILURE CRITERIA AA-B-2800 TEST PROCEDURE |
112 | AA-B-2900 FINAL REPORT AA-B-3100 PURPOSE AA-B-3200 SCOPE AA-B-3300 TEST SPECIMENS AA-B-3400 SPECIAL EQUIPMENT OR FIXTURES AA-B-3500 TEST SETUP |
113 | AA-B-3600 TEST REQUIREMENTS |
114 | AA-B-3700 ACCEPTANCE AND FAILURE CRITERIA AA-B-3800 TEST PROCEDURE AA-B-3900 FINAL REPORT |
115 | NONMANDATORY APPENDIX AA-C QUALIFICATION BY A COMBINATION OF ANALYSIS AND TESTING AA-C-3100 TESTING PROGRAM CONSIDERATIONS AA-C-4100 COMMON APPLICATIONS AA-C-4200 DYNAMIC AND STATIC SUPPORTING TESTS AA-C-4210 Dynamic Supporting Tests |
116 | AA-C-4220 Static Supporting Tests |
117 | SECTION AB SYSTEM DESIGN GUIDE AB-1100 SCOPE AB-1200 PURPOSE AB-1300 APPLICABILITY AB-1400 DEFINITIONS AND TERMS |
118 | AB-3100 POWER GENERATION FACILITIES AB-3110 Air Treatment Systems for DBA Requirements AB-3120 Normal Operation Systems AB-4100 SYSTEM FUNCTION AB-4200 SYSTEM BOUNDARIES AB-4300 SYSTEM INTERFACES |
119 | AB-4400 SYSTEM DESIGN AB-4410 SGTS Typical Components AB-4420 SGTS Required Design Parameters |
120 | AB-4500 SYSTEM OPERATION AB-4510 Recommendation for Control of Heat of Radioactive Decay and Heat of Oxidation AB-4600 SYSTEM INTERLOCKS AND ALARMS AB-5100 FILTER TRAIN COMPONENTS AB-5110 Description AB-5120 Applications |
121 | AB-5130 Cautions and Concerns AB-5140 Recommendations for Installation AB-5150 Recommendations for Maintainability AB-5160 Recommendations for Fire Detection |
122 | AB-5170 Recommendations for Fire Protection AB-5200 HEATERS AB-5210 Description AB-5220 Applications AB-5230 Cautions and Concerns AB-5240 Recommendations for Installation |
123 | AB-5250 Recommendations for Maintainability AB-5260 Recommendations for Fire Protection AB-5300 FANS AB-5310 Description AB-5320 Applications AB-5330 Cautions and Concerns AB-5340 Recommendations for Installation |
124 | AB-5350 Recommendations for Maintainability AB-5360 Recommendations for Fire Protection AB-5400 VALVES, PIPING, COOLING COILS AB-5410 Description AB-5420 Applications AB-5430 Cautions and Concerns |
125 | AB-5440 Recommendations for Installation AB-5450 Recommendations for Maintainability AB-5460 Recommendations for Fire Protection AB-5500 DUCT AND DAMPERS AB-5510 Description AB-5520 Applications AB-5530 Cautions and Concerns AB-5540 Recommendations for Installation AB-5550 Recommendations for Maintainability AB-5560 Recommendations for Fire Protection |
126 | AB-5600 INSTRUMENTATION AB-5610 Description AB-5620 Applications AB-5630 Cautions and Concerns AB-5640 Recommendations for Installation AB-5650 Recommendations for Maintainability AB-5660 Recommendations for Fire Protection AB-5700 HOUSINGS AB-5710 Description AB-5720 Applications AB-5730 Cautions and Concerns AB-5740 Recommendations for Installation |
127 | AB-5750 Recommendations for Maintainability AB-5760 Recommendations for Fire Protection AB-6100 SYSTEMS AB-6200 HOUSINGS AB-6300 COMPONENTS |
128 | AB-8100 Air Treatment Systems for DBA Requirements |
129 | Figure AB-8100-1 Typical Standby Gas Treatment Filtration System |
130 | Division II Ventilation Air Cleaning and Ventilation Air Conditioning SECTION BA FANS AND BLOWERS BA-1100 SCOPE BA-1200 PURPOSE BA-1300 APPLICABILITY BA-1400 DEFINITIONS AND TERMS |
132 | BA-3100 GENERAL BA-3110 Material Stress Values BA-3200 SPECIAL LIMITATIONS ON MATERIALS BA-3300 DESIGNATION OF MATERIALS BA-3400 CERTIFICATION OF MATERIALS BA-3410 Centrifugal Fans BA-3420 Axial Fans BA-3500 PURCHASED MATERIALS BA-3600 DRIVER MATERIALS BA-4100 DESIGN CONDITIONS BA-4110 Performance |
133 | BA-4120 Environmental Conditions BA-4130 Loading BA-4140 Leakage |
134 | BA-4150 Support Boundary BA-4160 Vibration BA-4200 SELECTION BA-4210 Fans Table BA-4162-1 Maximum Allowable Displacement |
135 | BA-4220 Drivers BA-4300 CONSTRUCTION BA-4310 General BA-4320 Fans BA-4330 Drivers and Drives |
136 | BA-4340 Accessories |
137 | BA-4400 REPORTS AND CALCULATIONS BA-4410 Performance Rating BA-4420 Sound Level Data Report BA-4430 Structural Verification Considerations BA-5100 FAN INSPECTION AND TESTING BA-5110 General Testing Requirements |
138 | BA-5120 Performance Acceptance Tests BA-5130 Sound Tests BA-5140 Mechanical Tests |
139 | BA-5150 Test Results and Reports BA-5200 DRIVER INSPECTION AND TESTING BA-5210 First Unit of a Design BA-5220 Succeeding Units of a Design BA-6100 FABRICATION BA-6110 Selection of Materials BA-6200 INSTALLATION BA-7100 GENERAL BA-7200 PACKAGING BA-7300 SHIPPING BA-7400 RECEIVING BA-7500 STORAGE BA-7600 DRIVERS SHIPPED SEPARATELY BA-7610 Short-Term |
140 | BA-7620 Long-Term (Over 6 Months) BA-8100 GENERAL BA-8200 REQUIRED DOCUMENTATION FOR FANS BA-8210 Certified Fan Performance Curves BA-8220 Material Certification BA-8300 DRAWINGS AND DOCUMENTATION BA-9100 GENERAL BA-9200 FANS BA-9210 Required Nameplate Data BA-9220 Drivers BA-9300 ACCEPTABLE METHODS FOR MARKING ACCESSORIES BA-9400 OPERATING AND MAINTENANCE MANUALS |
141 | NONMANDATORY APPENDIX BA-A FAN SYSTEM CONSIDERATIONS BA-A-1100 SYSTEM CHARACTERISTICS BA-A-1200 SYSTEM EFFECTS ON FAN PERFORMANCE BA-A-1300 FAN AND SYSTEM MATCHING BA-A-1400 FAN-SYSTEM CAPACITY CONTROL BA-A-1500 MULTIPLE FAN SYSTEMS |
142 | NONMANDATORY APPENDIX BA-B DIVISION OF RESPONSIBILITY |
143 | Table BA-B-1000-1 Division of Responsibility |
145 | SECTION DA DAMPERS AND LOUVERS DA-1100 SCOPE DA-1200 PURPOSE DA-1300 APPLICABILITY DA-1310 Exclusion of Items DA-1320 Exclusion of Specific Designs DA-1330 Boundary Limits DA-1400 DEFINITIONS AND TERMS DA-1410 Components DA-1420 Function |
146 | DA-1430 Configuration DA-1440 Leakage and Blade Operating Positioning DA-1450 Pressure DA-1460 Temperature DA-1470 Tests DA-1480 Construction DA-1490 Torque |
147 | DA-3100 ALLOWABLE MATERIALS DA-3110 Materials of Construction DA-3120 Allowable Stress DA-3130 Bearing Materials DA-3140 Seal Materials DA-3200 SPECIAL LIMITATIONS ON MATERIALS DA-3210 Metals DA-3220 Nonmetallic Materials DA-3230 Deterioration of Materials in Service DA-3300 CERTIFICATION OF MATERIALS |
148 | DA-4100 GENERAL DESIGN DA-4110 Requirements of Design Specifications DA-4120 Requirements of the Manufacturer DA-4130 Performance Requirements DA-4200 TECHNICAL REQUIREMENTS DA-4210 Structural |
149 | DA-4220 Thermal Expansion |
150 | DA-4230 Torque DA-4240 Linkage DA-4250 Bearings |
151 | DA-4260 Seals DA-4270 Frame Construction DA-4280 Mounting of Actuators and Accessories DA-4300 ACTUATORS DA-4310 Power-Operated Actuators |
152 | DA-4320 Manual Actuators DA-4330 Self-Contained Actuators DA-4340 Heat- or Temperature-Operated Actuators DA-4400 ACCESSORIES DA-4410 Accessory Requirements DA-4420 Auxiliary Energy Source DA-4430 Modulating Actuator Requirements DA-4440 Position Indicators DA-4450 Environmental Design Requirements DA-4460 Piping of Pneumatic Actuators DA-4470 Electrical Wiring Requirements DA-5100 TESTING |
153 | DA-5110 Pressure Drop Testing DA-5120 Cycle Time and Cycle Repetition DA-5130 Frame Leakage Testing for Frame Leakage Class A, B, or C DA-5140 Seat Leakage Testing DA-5141 Seat Leakage Test for Leakage Class 0 Dampers (Bubble Method). DA-5142 Seat Leakage Test for Leakage Class I Dampers. DA-5143 Seat Leakage Test for Leakage Class II or Class III Dampers or Louvers. DA-5144 Seat Leakage Test for Leakage Class IV Dampers and Louvers. DA-5145 Fire Damper Closure Test. DA-6100 WELDING AND BRAZING |
154 | DA-8100 DAMPER AND LOUVER PERFORMANCE DA-8300 QUALITY ASSURANCE RECORDS DA-9100 NAMEPLATES AND STAMPING DA-9200 MANUALS |
155 | MANDATORY APPENDIX DA-I SEAT AND FRAME LEAKAGE Table DA-I-1000-1 Maximum Permissible Seat Leakage Rate, scfm/ft2 (scmh/m2), of Damper or Adjustable Louver Face Area at 1 in. wg (25.4 mm wg) Differential Pressure Table DA-I-1000-2 Maximum Permissible Frame Leakage Rate Classes at Frame Design Pressure |
156 | MANDATORY APPENDIX DA-II DAMPER AND LOUVER CONFIGURATIONS Figure DA-II-1000-1 Parallel-Blade Dampers |
157 | Figure DA-II-1000-2 Wing-Blade Damper Figure DA-II-1000-3 Poppet Damper |
158 | Figure DA-II-1000-4 Opposed-Blade Damper Figure DA-II-1000-5 Single-Blade Damper |
159 | Figure DA-II-1000-6 Slide-Gate Guillotine Damper |
160 | Figure DA-II-1000-7 Curtain-Type Dampers |
161 | Figure DA-II-1000-8 Louver |
162 | NONMANDATORY APPENDIX DA-A DIVISION OF RESPONSIBILITY |
163 | Table DA-A-1000-1 Division of Responsibility |
165 | SECTION SA DUCTWORK SA-1100 SCOPE SA-1200 PURPOSE SA-1300 APPLICABILITY SA-1400 DEFINITIONS AND TERMS |
166 | Figure SA-1300-1 Ductwork and Ductwork Support — Interface Boundary |
167 | SA-3100 GENERAL SA-3200 MATERIAL SUBSTITUTION SA-3300 MATERIAL TESTING SA-3400 MATERIAL SPECIFICATIONS |
168 | SA-4100 GENERAL SA-4200 DESIGN CRITERIA SA-4210 Load Criteria |
169 | SA-4220 Stress Criteria SA-4230 Deflection Criteria SA-4240 Other Criteria SA-4300 DUCTWORK JOINTS AND SEAMS SA-4310 General SA-4320 Duct Joints and Seams |
170 | SA-4400 COMPONENTS SA-4410 Flexible Connections SA-4420 Gaskets SA-4430 Access Doors and Panels SA-4440 Ports for Testing and Maintenance SA-4450 Miscellaneous |
171 | SA-4500 PRESSURE BOUNDARY LEAKAGE SA-4510 General SA-4520 Applicability SA-4530 Evaluation |
172 | SA-4540 Leakage Testing SA-4600 DESIGN SPECIFICATION SA-5100 GENERAL SA-5110 Scope and Applicability SA-5120 Responsibility for Procedures SA-5200 VISUAL INSPECTION SA-5210 General Requirements SA-5220 Welded Connections SA-5230 Ductwork |
173 | SA-5240 Ductwork Supports SA-5300 PRESSURE BOUNDARY LEAKAGE TESTING SA-5310 General SA-5320 Systems Completeness SA-5330 Allowances for Testing System Leakage Rates by Sections SA-5340 Testing Procedures SA-5350 Documentation |
174 | SA-5360 Acceptance Criteria SA-5400 STRUCTURAL CAPABILITY TESTS SA-5410 Ductwork Pressure Test SA-5420 Longitudinal Seam Qualification Test SA-6100 GENERAL SA-6110 Scope and Applicability SA-6120 Materials SA-6130 Control of Installation and Fabrication Process SA-6140 Welding SA-6200 FABRICATION PROCESSES |
175 | SA-6300 MECHANICAL FASTENING SA-6400 FABRICATION TOLERANCES SA-6500 INSTALLATION TOLERANCES SA-6600 CLEANING, FINISHING, AND COATING SA-7100 GENERAL SA-7200 PACKAGING |
176 | Table SA-6400-1 Rectangular Ducts: Maximum Allowable Tolerances |
177 | Table SA-6400-2 Circular Ducts: Maximum Allowable Tolerances |
178 | SA-7300 SHIPPING SA-7400 RECEIVING SA-7500 STORAGE Table SA-6400-3 Flatness of Surface: Maximum Allowable Waviness Tolerance |
179 | SA-8100 GENERAL SA-8200 MATERIAL IDENTIFICATION SA-8300 DRAWINGS AND DOCUMENTATION SA-9100 GENERAL SA-9200 STAMPING/MARKING SA-9210 Ducts SA-9220 Ductwork Supports SA-9230 Air Distribution Accessories |
180 | NONMANDATORY APPENDIX SA-A DIVISION OF RESPONSIBILITY Table SA-A-1000-1 Division of Responsibility |
181 | NONMANDATORY APPENDIX SA-B PROCEDURES TO DETERMINE ALLOWABLE LEAKAGE FOR DUCTWORK SA-B-1100 PURPOSE SA-B-1200 ALLOWABLE LEAKAGE BY HEALTH PHYSICS CRITERIA SA-B-1210 General SA-B-1220 Procedure to Determine Allowable Leakage by Maximum Permissible Concentration Method |
182 | Figure SA-B-1221-1 Allowable Unit Leakage From Duct or Housing to Occupied Space |
185 | Figure SA-B-1222-1 System Parameters |
186 | SA-B-1230 Allowable Leakage by Iodine Protection Factor Reduction |
187 | Figure SA-B-1232.1-1 Control Room System Flow Diagram |
189 | Figure SA-B-1232.2-1 Control Room System Flow Diagram With Leakage Paths |
190 | Table SA-B-1234-1 Control Room Air Cleaning System Parameters for Leakage Analysis Table SA-B-1234-2 Control Room Air Conditioning System Parameters for Leakage Analysis |
192 | SA-B-1300 ADDITIONAL LEAKAGE CRITERIA SA-B-1310 Air Cleaning System Effectiveness SA-B-1320 Air Cooling Effectiveness SA-B-1330 System Quality SA-B-1400 AIR CLEANING SYSTEM CONFIGURATIONS AND LEAKAGE CLASSES SA-B-1410 Leakage Classes |
193 | Table SA-B-1310-1 Maximum Allowable Leakage Factors for Air Cleaning Effectiveness |
194 | Figure SA-B-1410-1 Single-Pass Air Cleaning System Configuration |
195 | Figure SA-B-1410-2 Recirculating Air Cleaning System Configurations |
196 | Figure SA-B-1410-3 Recirculating Air Cleaning System Configurations |
197 | NONMANDATORY APPENDIX SA-C ADDITIONAL GUIDELINES FOR DUCT DESIGN AND CONSTRUCTION SA-C-1100 INTRODUCTION SA-C-1200 GENERAL SA-C-1210 Access Doors SA-C-1220 Drains SA-C-1230 Duct |
198 | SA-C-1240 Access for Service, Testing, and Inspection SA-C-1300 DUCT CONSTRUCTION STANDARDS Table SA-C-1300-1 Duct Construction Standards |
199 | SECTION HA HOUSINGS HA-1100 SCOPE HA-1200 PURPOSE HA-1300 APPLICABILITY HA-1400 DEFINITIONS AND TERMS Figure HA-1300-1 Housing, Air Cleaning Unit: Walk-In Type |
200 | Figure HA-1300-2 Housing, Air Cleaning Unit: Side-Access Type Figure HA-1300-3 Housing, Air Conditioning Unit: Walk-In Type |
201 | HA-3100 ALLOWABLE MATERIALS HA-3110 General Requirements HA-3120 Protective Coatings |
202 | HA-3200 SPECIAL LIMITATIONS ON MATERIALS HA-3210 Metals HA-3300 CERTIFICATION OF MATERIAL HA-4100 GENERAL DESIGN HA-4200 DESIGN CRITERIA HA-4210 Load Criteria |
203 | HA-4220 Stress Criteria HA-4230 Deflection Criteria HA-4240 Other Criteria Table HA-4212-1 Load Combinations |
204 | HA-4300 HOUSING JOINTS AND SEAMS HA-4310 General HA-4320 Housing Joints and Seams HA-4330 Air Cleaning Unit Joints and Seams HA-4340 Air Conditioning and Air Handling Units Housing, Joints and Seams |
205 | HA-4400 ACCESSORIES HA-4410 Gaskets HA-4420 Access Doors and Panels HA-4430 Provisions for Testing and Maintenance HA-4440 Miscellaneous |
206 | HA-4500 PRESSURE BOUNDARY LEAKAGE HA-4510 General HA-4520 Applicability HA-4530 Evaluation |
207 | HA-4600 DESIGN SPECIFICATION HA-5100 GENERAL HA-5110 Scope and Applicability HA-5120 Responsibility for Procedures HA-5200 INSPECTION HA-5210 General Requirements HA-5220 Housings |
208 | HA-5230 Housing Supports HA-5240 Filter Mounting Frame to Housing Weld Inspection HA-5300 PRESSURE BOUNDARY LEAKAGE TESTING HA-5310 Allowance for Housing Leakage Rates by Sections HA-5330 Testing Procedures HA-5340 Documentation HA-5350 Acceptance Criteria HA-5400 MOUNTING FRAME TO HOUSING LEAKAGE TEST HA-5500 STRUCTURAL CAPABILITY TEST HA-5600 AIRFLOW DISTRIBUTION TESTS |
209 | HA-5700 AIR-AEROSOL MIXING UNIFORMITY TESTS HA-5800 SAMPLING MANIFOLD TESTING HA-5900 AIR CONDITIONING AND AIR HANDLING UNIT TESTING HA-6100 GENERAL HA-6110 Scope and Applicability HA-6120 Materials HA-6130 Control of Installation and Fabrication Process HA-6140 Welding HA-6200 FABRICATION PROCESS HA-6210 Cutting, Forming, Bending, Aligning, and Fitting |
210 | HA-6300 MECHANICAL FASTENING HA-6310 General HA-6400 FABRICATION TOLERANCES HA-6410 General HA-6420 Side-Access Housing and Gasket Seal Surfaces HA-6430 Side-Access Housing Filter Fluid Seal Surfaces HA-6500 CLEANING HA-7100 GENERAL HA-7200 PACKAGING HA-7210 General HA-7220 Protection HA-7300 SHIPPING |
211 | HA-7400 RECEIVING HA-7500 STORAGE HA-7510 General HA-7520 Drains and Vents HA-7530 Other Components HA-8100 GENERAL HA-8200 MATERIAL IDENTIFICATION HA-8300 DRAWINGS AND DOCUMENTATION HA-9100 GENERAL HA-9200 STAMPING AND MARKING HA-9210 Housings HA-9220 Housing Accessories |
212 | NONMANDATORY APPENDIX HA-A DIVISION OF RESPONSIBILITY Table HA-A-1000-1 Division of Responsibility |
213 | NONMANDATORY APPENDIX HA-B ADDITIONAL GUIDELINES FOR HOUSING DESIGN AND CONSTRUCTION HA-B-1100 INTRODUCTION HA-B-1200 GENERAL HA-B-1210 Access Doors HA-B-1220 Drains |
215 | NONMANDATORY APPENDIX HA-C MANIFOLD DESIGN GUIDELINES HA-C-1100 INTRODUCTION HA-C-1200 MANIFOLD REQUIREMENTS FOR IN-PLACE TESTS HA-C-1210 Airflow HA-C-1220 Challenge/Air Mixing Uniformity HA-C-1230 Multiple-Component Banks in Series HA-C-1240 Absence of Components in Series HA-C-1250 Uniformity HA-C-1300 CONSIDERATIONS FOR USE OF PERMANENTLY INSTALLED MANIFOLDS HA-C-1310 HA-C-1320 HA-C-1330 |
216 | HA-C-1340 HA-C-1350 HA-C-1400 INJECTION MANIFOLDS HA-C-1410 HA-C-1420 HA-C-1430 Figure HA-C-1230-1 Common Configurations Requiring Test Manifolds (Plan A) |
217 | HA-C-1440 General Rules Applicable to All Injection Manifolds HA-C-1450 Figure HA-C-1230-2 Common Configurations Requiring Test Manifolds (Plan B) |
218 | HA-C-1460 HA-C-1470 HA-C-1480 HA-C-1490 HA-C-1500 SAMPLE MANIFOLDS HA-C-1510 Figure HA-C-1230-3 Common Configurations Requiring Test Manifolds (Plan C) |
219 | Figure HA-C-1230-4 Common Configurations Requiring Test Manifolds (Plan D) |
220 | Figure HA-C-1230-5 Common Configurations Requiring Test Manifolds (Plan E) |
221 | HA-C-1520 HA-C-1530 HA-C-1540 |
222 | NONMANDATORY APPENDIX HA-D PERFORMANCE TEST FOR QUALIFICATION OF SAMPLING MANIFOLDS HA-D-1100 PURPOSE HA-D-1200 LIMITS HA-D-1300 TEST REQUIREMENTS HA-D-1400 TEST METHOD |
223 | HA-D-1500 ACCEPTANCE CRITERIA HA-D-1510 Single-Point Sample HA-D-1520 Sample Manifold HA-D-1600 DOCUMENTATION HA-D-1700 ACCEPTANCE OF RESULTS |
224 | SECTION RA REFRIGERATION EQUIPMENT RA-1100 SCOPE RA-1200 PURPOSE RA-1300 APPLICABILITY RA-1310 Clarification of Code Applicability RA-1320 Exclusion of Components RA-1400 DEFINITIONS AND TERMS |
225 | RA-3100 GENERAL MATERIAL REQUIREMENTS RA-3110 Pressure-Retaining Materials |
226 | RA-3120 Component Support Materials RA-3130 Materials for Nonmetallic Components RA-3140 Electrical Materials RA-3150 Pump and Compressor Materials RA-3160 Valve, Piping, and Fitting Materials RA-3170 Welding and Brazing Materials RA-4100 PURPOSE RA-4200 DESIGN SPECIFICATION |
227 | RA-4300 EQUIPMENT PERFORMANCE REQUIREMENTS RA-4400 MECHANICAL DESIGN REQUIREMENTS RA-4410 Waterside System |
228 | RA-4420 Refrigerant Side System RA-4430 Lubrication System |
229 | RA-4500 STRUCTURAL DESIGN REQUIREMENTS RA-4510 General RA-4520 Equipment Attachment Boundary RA-4600 ELECTRICAL DESIGN REQUIREMENTS RA-4610 Electric Motors RA-4620 Electric Valve and Vane Actuators RA-4630 Control Systems RA-4640 Electrical Wiring, Splices, and Connections |
230 | RA-4700 MAINTENANCE CRITERIA RA-5100 RATING RA-5200 TESTING RA-5210 Pressure Vessel Testing |
231 | RA-5220 Functional Testing of Motors |
232 | RA-5300 EXAMINATION RA-5310 Nondestructive Examination RA-6100 WELDING AND BRAZING RA-6110 Welding RA-6120 Brazing RA-6130 Welding and Brazing of Non-ASME BPVC Pressure-Retaining Components and Supports |
233 | RA-6200 CLEANING, FINISHING, AND COATING RA-6210 Cleanliness RA-6220 Cleaning and Finishing RA-6230 Finishing and Surface Preparation |
234 | RA-6240 Coating and Application RA-6300 INSTALLATION RA-7100 GENERAL REQUIREMENTS RA-7200 PACKAGING RA-7210 ASME BPVC, Section III Equipment RA-7220 ASME BPVC, Section VIII Equipment RA-7230 Motors Shipped Separately |
235 | RA-7300 SHIPPING RA-7310 ASME BPVC Section III Equipment RA-7320 ASME BPVC, Section VIII Equipment RA-7400 STORAGE RA-7410 ASME BPVC, Section III Equipment RA-7420 ASME BPVC, Section VIII Equipment RA-7500 HANDLING AND RIGGING RA-7510 ASME BPVC, Section III Equipment RA-7520 ASME BPVC Section VIII Equipment |
236 | RA-7600 ASSEMBLY, ERECTION, AND START-UP RA-7610 Field-Assembled or Field-Erected Equipment RA-7620 External Connections and Services RA-7630 Start-Up and Periodic Testing RA-8100 GENERAL RA-9100 GENERAL REQUIREMENTS RA-9200 NAMEPLATES AND STAMPING RA-9300 DATA REPORTS |
237 | Forms FORM RA-1 CENTRIFUGAL COMPRESSOR TEST RECORD |
238 | FORM RA-1a CENTRIFUGAL COMPRESSOR OIL PUMP PRESSURE TEST |
239 | FORM RA-1b CENTRIFUGAL COMPRESSOR PRESSURE TEST RECORD |
240 | FORM RA-2 RECIPROCATING SCROLL/SCREW COMPRESSOR TEST RECORD |
241 | FORMRA-2a RECIPROCATING SCROLL/SCREW COMPRESSOR PRESSURE TEST RECORD |
242 | FORM RA-3 ELECTRICAL TEST RECORD — CONTROLS AND CONTROL PANELS |
243 | FORM RA-4 PERFORMANCE TEST RECORD (U.S. CUSTOMARY) |
245 | FORM RA-M4 PERFORMANCE TEST RECORD (SI) |
247 | MANDATORY APPENDIX RA-I PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (U.S. CUSTOMARY) RA-I-1100 TEST CONDITIONS RA-I-1200 EFFECT OF FOULING FACTOR RA-I-1300 HEAT BALANCE EQUATION RA-I-1400 MEASURED HEAT BALANCE RA-I-1500 TABULATION OF CAPACITY RA-I-1600 POWER INPUT RA-I-1700 REFRIGERATION MACHINES EQUIPPED WITH SUBCOOLERS |
248 | Table RA-I-1100-1 Test Conditions Table RA-I-1200-1 Effect of Fouling Factor Table RA-I-1300-1 Heat Balance Equation |
249 | Table RA-I-1500-1 Tabulation of Capacity |
250 | MANDATORY APPENDIX RA-MI PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (SI) RA-MI-1100 TEST CONDITIONS RA-MI-1200 EFFECT OF FOULING FACTOR RA-MI-1300 HEAT BALANCE EQUATION RA-MI-1400 MEASURED HEAT BALANCE RA-MI-1500 TABULATION OF CAPACITY RA-MI-1600 POWER INPUT RA-MI-1700 REFRIGERATION MACHINES EQUIPPED WITH SUBCOOLERS |
251 | Table RA-MI-1100-1 Test Conditions Table RA-MI-1200-1 Effect of Fouling Factor |
252 | Table RA-MI-1300-1 Heat Balance Equation Table RA-MI-1500-1 Tabulation of Capacity |
253 | MANDATORY APPENDIX RA-II MANDATORY LIST OF INSTRUMENTATION FUNCTIONS AND CONTROL FUNCTIONS Table RA-II-1000-1 Mandatory List of Instrumentation Functions and Control Functions |
254 | NONMANDATORY APPENDIX RA-A DIVISION OF RESPONSIBILITY |
255 | Table RA-A-1000-1 Division of Responsibility |
257 | NONMANDATORY APPENDIX RA-B TYPICAL EXTERNAL INTERFACE DIAGRAMS Figure RA-B-1000-1 Interface Points — Typical Two-Vessel Design |
258 | SECTION CA CONDITIONING EQUIPMENT CA-1100 SCOPE CA-1200 PURPOSE CA-1300 APPLICABILITY CA-1310 Clarification of Code Applicability CA-1320 Exclusion of Components CA-1330 Interfacing Boundaries CA-1400 DEFINITIONS AND TERMS CA-1410 General CA-1420 Water, Steam, and Volatile Refrigerant Coils |
259 | CA-1440 Electric Heating Coils CA-3100 MATERIAL SPECIFICATIONS |
260 | CA-3200 WATER, STEAM, AND VOLATILE REFRIGERANT COIL MATERIALS CA-3210 Pressure-Retaining Materials for Water and Steam Coils CA-3220 Pressure-Retaining Materials for Volatile Refrigerant Coils CA-3230 Non-Pressure-Retaining Materials CA-3240 Load-Bearing Members CA-3250 Non-Load-Carrying Members CA-3400 ELECTRIC HEATING COIL MATERIALS CA-3500 CERTIFICATION OF MATERIALS |
261 | CA-4100 DESIGN CONDITIONS FOR WATER AND STEAM COILS CA-4110 Design Specification CA-4120 Technical Requirements |
262 | CA-4130 Structural Requirements for Water, Steam, and Volatile Refrigerant Coils Table CA-4122-1 Maximum Water Velocities in Water Coils |
263 | CA-4200 DESIGN CONDITIONS FOR VOLATILE REFRIGERANT COILS CA-4210 Design Specification CA-4220 Technical Requirements |
264 | CA-4400 DESIGN CONDITIONS FOR ELECTRIC HEATING COILS CA-4410 Design Specification CA-4420 Technical Requirements |
265 | CA-4430 Structural Requirements for Electric Heating Coils |
266 | CA-5100 GENERAL REQUIREMENTS CA-5200 TESTING OF WATER, STEAM, AND VOLATILE REFRIGERANT COILS CA-5210 Performance Verification and Validation |
267 | CA-5220 Pressure Testing for Water and Steam Coils CA-5230 Pressure Testing for Volatile Refrigerant Coils CA-5240 Nondestructive Examination CA-5400 TESTING OF ELECTRIC HEATING COILS CA-5410 General Requirements CA-5420 Functional Test CA-5430 Dielectric Withstand Test CA-5440 Resistance Test |
268 | CA-5450 Nondestructive Examination CA-5500 TEST REPORTS CA-6100 GENERAL REQUIREMENTS CA-6110 Introduction CA-6120 Welding CA-6130 Brazing CA-6140 Mechanical Joining CA-6200 CLEANING, FINISHING, AND COATING CA-6210 Cleaning and Finishing |
269 | CA-6220 Finishing and Surface Preparation CA-6230 Coating and Application CA-7100 GENERAL REQUIREMENTS CA-7200 PACKAGING CA-7300 SHIPPING |
270 | CA-7400 STORAGE CA-7500 HANDLING CA-8100 GENERAL REQUIREMENTS CA-8110 Introduction CA-8120 Documentation and Retention CA-9100 GENERAL REQUIREMENTS CA-9200 COILS |
271 | CA-9300 INFORMATION ON NAMEPLATES CA-9310 Water, Steam, and Volatile Refrigerant Coils CA-9320 Electric Heating Coils CA-9400 NAMEPLATE VISIBILITY Table CA-8121-1 Lifetime Quality Assurance Records Table CA-8121-2 Nonpermanent Quality Assurance Records |
272 | CA-9500 DATA REPORTS CA-9510 Coils CA-9520 Volatile Refrigerant Coils CA-10100 GENERAL |
273 | NONMANDATORY APPENDIX CA-A DIVISION OF RESPONSIBILITY Table CA-A-1000-1 Division of Responsibility |
274 | NONMANDATORY APPENDIX CA-B DESIGN RECOMMENDATIONS CA-B-1100 SCOPE CA-B-1200 GENERAL RECOMMENDATIONS |
275 | SECTION FA MOISTURE SEPARATORS FA-1100 SCOPE FA-1200 PURPOSE FA-1300 APPLICABILITY FA-1310 Moisture Separators FA-1320 Limitations FA-1400 DEFINITIONS AND TERMS FA-3100 ALLOWABLE MATERIALS FA-3110 Pads FA-3120 Filter Cases, Cross Grids, and Supports FA-3130 Rivets FA-3140 Gaskets FA-3150 Adhesive FA-3200 LIMITATIONS |
276 | FA-3300 MATERIAL CERTIFICATION FA-4100 GENERAL DESIGN FA-4200 TECHNICAL REQUIREMENTS FA-4210 Design Requirements FA-4220 Moisture Separator Assembly FA-4300 STRUCTURAL REQUIREMENTS FA-4310 General FA-4320 Load Definition FA-4330 Load Combinations FA-4340 Acceptance Criteria FA-5100 QUALIFICATION TESTS FA-5110 Moisture Separator Rough Handling Qualifications FA-5120 Moisture Separator Airflow Resistance Test |
277 | Figure FA-4100-1 Typical Moisture Separation Configuration Table FA-4100-1 Moisture Separator Performance Specifications |
278 | FA-5130 Moisture Separator Performance Test FA-5200 PRODUCTION INSPECTION AND TESTING FA-5210 Dimensional Inspection FA-5220 Welding Inspection FA-5230 Moisture Separator Airflow Resistance Test FA-6100 REPAIRS FA-6200 CLEANING FA-6300 TOLERANCES FA-6310 Flatness and Squareness FA-6320 Overall Dimensions FA-8100 RESPONSIBILITY FA-8200 DOCUMENTATION |
279 | FA-8300 CERTIFICATE OF CONFORMANCE FA-9100 MOISTURE SEPARATOR MARKING FA-9200 PACKAGE MARKING |
280 | NONMANDATORY APPENDIX FA-A DIVISION OF RESPONSIBILITY Table FA-A-1000-1 Division of Responsibility |
281 | SECTION FB MEDIUM EFFICIENCY FILTERS FB-1100 SCOPE FB-1200 PURPOSE FB-1300 APPLICABILITY FB-1310 Limitations FB-1320 Responsibility FB-1400 DEFINITIONS AND TERMS FB-3100 ALLOWABLE MATERIALS FB-3110 Media FB-3120 Filter Frames |
282 | FB-3130 Separators FB-3140 Sealants and Adhesives FB-3150 Gaskets FB-3200 SPECIAL LIMITATIONS OF MATERIALS FB-4100 GENERAL DESIGN FB-4200 DESIGN CRITERIA FB-4300 STRUCTURAL REQUIREMENTS FB-5100 INSPECTION PLAN FB-5110 Plan FB-5120 Minimum Inspection Requirements FB-5130 Rejection and Reinspection FB-5200 QUALIFICATION TESTING FB-5210 Testing Requirements |
283 | FB-5220 Certification FB-5230 Requalification FB-5240 Seismic Qualification FB-6100 GENERAL FB-6200 MANUFACTURE AND ASSEMBLY FB-6210 Flatness and Squareness FB-6220 Overall Dimensions FB-7100 GENERAL FB-8100 GENERAL FB-8200 DOCUMENTATION FB-9100 FILTER MARKINGS |
284 | FB-9200 PACKAGE MARKING |
285 | NONMANDATORY APPENDIX FB-A DIVISION OF RESPONSIBILITY Table FB-A-1000-1 Division of Responsibility |
286 | SECTION FC HEPA FILTERS FC-1100 SCOPE FC-1200 PURPOSE FC-1300 APPLICABILITY FC-1310 HEPA Filters FC-1320 Limitations FC-1400 DEFINITIONS AND TERMS |
287 | FC-3100 ALLOWABLE MATERIALS FC-3110 Case Materials FC-3120 Gasket Materials |
288 | FC-3130 Filter Media FC-3140 Faceguards FC-3150 Adhesives FC-3160 Separators FC-3170 Ancillary Accessories FC-3200 SPECIAL LIMITATIONS OF MATERIALS FC-3210 Alternate Materials FC-4100 GENERAL DESIGN FC-4110 HEPA Filters FC-4120 Filter Case FC-4130 Filter Pack |
289 | Figure FC-4110-1 Type A, C, or D Metal-Cased, Gasket-Sealed Filter Figure FC-4110-2 Type A Wood Case Separator Filter |
290 | Figure FC-4110-3 Type B Mini Pleat Filter Figure FC-4110-4 Type C Separatorless Filter |
291 | Figure FC-4110-5 Type D Thread Separator Filter Table FC-4110-1 Nominal Sizes and Ratings |
292 | FC-4140 Gaskets FC-4150 Separators Figure FC-4142-1 Gel Seal Filter Corner — Isometric |
293 | FC-4160 Face Guards FC-4200 PERFORMANCE REQUIREMENTS FC-4210 Test Aerosol Particle Penetration FC-4220 Resistance to Airflow FC-4300 SEISMIC QUALIFICATION FC-5100 QUALIFICATION TESTING |
294 | FC-5110 Resistance to Airflow FC-5120 Test Aerosol Particle Penetration FC-5130 Resistance to Rough Handling FC-5140 Resistance to Pressure Table FC-5100-1 Test Groups and Sequence Table FC-5120-1 Acceptable Test |
295 | FC-5150 Resistance to Heated Air FC-5160 Spot Flame Resistance FC-5170 Structural Requirements FC-5200 INSPECTION FC-5300 PRODUCTION TESTING FC-6100 GENERAL REQUIREMENTS Table FC-5140-1 Test Conditions and Requirements |
296 | FC-6200 MANUFACTURE AND ASSEMBLY FC-6210 Tolerances FC-6220 Medium Installation FC-6300 WORKMANSHIP FC-8100 RESPONSIBILITY FC-8200 CERTIFICATE OF CONFORMANCE FC-9100 FILTER MARKING FC-9200 PACKAGE MARKING |
297 | MANDATORY APPENDIX FC-I |
298 | NONMANDATORY APPENDIX FC-A DIVISION OF RESPONSIBILITY Table FC-A-1000-1 Division of Responsibility |
299 | SECTION FD TYPE II ADSORBER CELLS FD-1100 SCOPE FD-1200 PURPOSE FD-1300 APPLICABILITY FD-1400 DEFINITIONS AND TERMS |
300 | FD-3100 ALLOWABLE MATERIALS FD-3110 Adsorbent FD-3120 Screens FD-3130 Casing FD-3140 Gaskets and Seal Pads FD-3150 Adhesive FD-3160 Threaded Fasteners FD-3170 Rivets FD-3200 LIMITS FD-3300 CERTIFICATION OF MATERIALS FD-3310 Metal Parts FD-3320 Gaskets and Seal Pads FD-3330 Adhesive FD-3340 Threaded Fasteners FD-3350 Hardware Items (Washers and Rivets) FD-4100 GENERAL DESIGN FD-4200 TECHNICAL REQUIREMENTS FD-4210 Design Requirements |
301 | Figure FD-4100-1 Type II Adsorber Cell |
302 | FD-4220 Adsorber Bed FD-4230 Case and Assembly FD-4300 STRUCTURAL REQUIREMENTS FD-4310 General FD-4320 Load Definition FD-4330 Load Combinations FD-4340 Acceptance Criteria |
303 | FD-5100 DIMENSIONAL INSPECTION FD-5200 WELDING INSPECTION FD-5210 Spot Welds FD-5220 Other Welds FD-5300 QUALIFICATION TESTS FD-5310 Design Qualification FD-5320 Filling Method Qualification FD-5330 Acceptance Tests Table FD-5332-1 Detector Sensitivity for Leak Test |
304 | FD-6100 DIMENSIONS AND TOLERANCES FD-6200 WELDING AND BRAZING FD-6210 Testing and Inspection FD-6220 Repairs FD-6300 FILLING FD-6400 CLEANING FD-7100 PACKAGING FD-7200 LOADING FOR SHIPMENT FD-7300 STORAGE Table FD-6100-1 Cell Dimensions and Tolerances |
305 | FD-7400 CONTAINERS FD-8100 DOCUMENTATION FD-9100 PERMANENT NAMEPLATE FD-9200 FILLING LABEL |
306 | MANDATORY APPENDIX FD-I CALCULATION OF RESIDENCE TIME OF ADSORBER CELLS |
307 | MANDATORY APPENDIX FD-II SAMPLE CANISTERS FD-II-1100 SCOPE FD-II-1200 APPLICABILITY FD-II-1300 DEFINITIONS AND TERMS FD-II-2100 TECHNICAL REQUIREMENTS FD-II-2110 Design Requirements FD-II-2120 Sample Canister Casing FD-II-2130 Assembly |
308 | Figure FD-II-2000-1 Examples of Sample Canister Configurations |
309 | Figure FD-II-2110-1 Detail of a Typical 2-in. Sample Canister |
310 | NONMANDATORY APPENDIX FD-A DIVISION OF RESPONSIBILITY Table FD-A-1000-1 Division of Responsibility |
311 | SECTION FE TYPE III ADSORBERS FE-1100 SCOPE FE-1200 PURPOSE FE-1300 APPLICABILITY FE-1310 Type III Adsorbers FE-1320 Adsorbents FE-1330 Limitations FE-1340 Responsibility FE-1400 DEFINITIONS AND TERMS |
312 | FE-3100 ALLOWABLE MATERIALS FE-3110 Adsorbent FE-3120 Screens and Casing FE-3130 Gaskets and Seal Pads FE-3140 Other Components FE-4100 GENERAL FE-4110 Type III Adsorbers FE-4120 Adsorber Service Equipment FE-4200 TECHNICAL REQUIREMENTS FE-4210 Design Criteria |
313 | Figure FE-4110-1 Horizontal Section of Type III Adsorber Bed |
314 | FE-4220 Sizing FE-4300 ADSORBENT BED DETAILS FE-4400 STRUCTURAL REQUIREMENTS FE-4410 General FE-4420 Load Definition FE-4430 Load Combinations FE-4440 Acceptance Criteria |
315 | FE-4500 ADSORBENT HANDLING SUBSYSTEMS FE-4510 Adsorbent Loading System FE-4520 Adsorbent Removal System FE-4600 AUXILIARY SYSTEMS FE-4610 Sampling of Installed Adsorbents |
316 | FE-4620 Fire Protection FE-5100 GENERAL FE-5200 VISUAL INSPECTION FE-5300 DIMENSIONAL INSPECTION FE-5310 Bed Depth |
317 | FE-5320 Screens FE-5330 Adsorbent Reservoir FE-5400 WELDING INSPECTION FE-5410 Spot Welds FE-5420 Seal Welds FE-5500 FABRICATION TOLERANCES FE-5600 DESIGN QUALIFICATION FE-5610 Functional Design Qualification FE-5620 Filling Method Qualification FE-5630 Seismic Qualification FE-5700 ACCEPTANCE TESTS FE-6100 GENERAL FE-6200 WELDING FE-6300 CLEANING FE-6400 CONSTRUCTION AND INSTALLATION FE-6500 REPAIRS |
318 | FE-7100 TYPE III ADSORBERS FE-7200 ADSORBENT MATERIALS FE-8100 GENERAL FE-8200 INSPECTION REPORTS AND DOCUMENTATION FE-9100 PERMANENT NAMEPLATES FE-9200 FILLING LABEL |
319 | MANDATORY APPENDIX FE-I RESIDENCE TIME CALCULATION |
320 | MANDATORY APPENDIX FE-II SCREEN WAVINESS INSPECTION TEST |
321 | MANDATORY APPENDIX FE-III ADSORBER FILLING QUALIFICATION TEST PROCEDURE FE-III-4100 ADSORBENT CHARACTERISTICS FE-III-4110 Bed Volume FE-III-4120 Adsorbent Weight FE-III-4130 Particle Size Distribution FE-III-4200 PACKING DENSITY FE-III-4300 ADSORBENT LOSSES |
323 | MANDATORY APPENDIX FE-IV TYPE III ADSORBER QUALIFICATION TEST PROCEDURE |
324 | FE-IV-4100 APPARATUS FE-IV-4200 TEST PROCEDURE Figure FE-IV-3000-1 Adsorbate Distribution Curves |
325 | FE-IV-4300 RH MEASUREMENT FE-IV-4400 RH BREAKTHROUGH FE-IV-4500 ADSORBENT SAMPLING FE-IV-4600 MOISTURE CONTENT Figure FE-IV-4100-1 Test Adsorber Setup |
326 | MANDATORY APPENDIX FE-V SAMPLE CANISTERS FE-V-1100 SCOPE FE-V-1200 APPLICABILITY FE-V-1300 DEFINITIONS AND TERMS FE-V-2100 TECHNICAL REQUIREMENTS FE-V-2110 Design Requirements FE-V-2120 Sample Canister Casing FE-V-2130 Assembly |
328 | NONMANDATORY APPENDIX FE-A VISUAL INSPECTION RECOMMENDATIONS FOR TYPE III ADSORBERS FE-A-1100 ADSORBER SECTIONS FE-A-1200 ADSORBER ASSEMBLY FE-A-1300 ADSORBER SERVICE SYSTEMS FE-A-1400 INSPECTION OPENINGS FE-A-1500 LABELING |
329 | NONMANDATORY APPENDIX FE-B DIVISION OF RESPONSIBILITY Table FE-B-1000-1 Division of Responsibility |
330 | SECTION FF ADSORBENT MEDIA FF-1100 SCOPE FF-1200 PURPOSE FF-1300 APPLICABILITY FF-1400 DEFINITIONS AND TERMS |
331 | FF-4100 GENERAL DESIGN FF-4200 ADSORBENT DEGRADATION FF-4210 Desorption FF-4220 Degradation |
332 | FF-5100 PHYSICAL TESTING FF-5110 Before Impregnation FF-5120 After Impregnation FF-5200 RADIOACTIVE TESTING FF-5210 Qualification Tests FF-5220 Radioactive Batch Tests FF-5300 ACCEPTABLE ASTM STANDARDS FF-7100 PROTECTION OF ADSORBENT MEDIA |
333 | FF-7200 STORAGE FF-7300 CONTAINERS FF-8100 DOCUMENTATION |
334 | NONMANDATORY APPENDIX FF-A DIVISION OF RESPONSIBILITY Table FF-A-1000-1 Division of Responsibility |
335 | SECTION FG MOUNTING FRAMES FOR AIR-CLEANING EQUIPMENT FG-1100 SCOPE FG-1200 LIMITATIONS FG-1300 PURPOSE FG-1400 RESPONSIBILITY FG-3100 ALLOWABLE MATERIALS FG-3200 MATERIAL LIMITATIONS FG-4100 GENERAL DESIGN FG-4110 HEPA Filter Mounting Frames |
336 | FG-4120 Type II Adsorber Cell Mounting Frames Figure FG-4110-1 Typical Filter Mounting Frame |
337 | Figure FG-4120-1 Typical Type II Adsorber Mounting Frame |
338 | FG-4130 Medium Efficiency Filter Mounting Frames FG-4140 Moisture Separator Mounting Frames FG-4141 Moisture Separator Mounting Frame Dimensions. FG-4142 Moisture Separator Clamping. FG-4143 Moisture Separator Support. Figure FG-4140-1 Typical Moisture Separator Mounting Frame Figure FG-4140-1 Typical Moisture Separator Mounting Frame |
339 | FG-4144 Penetrations. FG-4150 Common Requirements FG-4151 Galling Prevention. FG-4200 STRUCTURAL REQUIREMENTS FG-4210 General FG-4220 Load Definition FG-4230 Load Combinations FG-4240 Acceptance Criteria FG-4300 STRUCTURAL DESIGN ANALYSIS FG-4310 Filter Mounting Frame Deflection Limits |
340 | FG-4320 Type II Adsorber Cell and Moisture Separator Mounting Frame Deflection Limits FG-4330 Pressure Impulse Loading FG-5100 DIMENSIONAL INSPECTION FG-5200 ALIGNMENT AND SURFACE FINISH FOR HEPA FILTER AND TYPE II ADSORBER CELL MOUNTING FRAMES FG-5210 HEPA Filter and Type II Adsorber Cell Mounting Frame Alignment FG-5220 HEPA Filter and Type II Adsorber Cell Mounting Frame Flatness FG-5230 HEPA Filter and Type II Adsorber Cell Mounting Frame Dimensions |
341 | FG-5240 HEPA Filter and Type II Adsorber Cell Mounting Frame Surface Finish FG-5300 ALIGNMENT AND SURFACE FINISH FOR MEDIUM EFFICIENCY FILTER AND MOISTURE SEPARATOR MOUNTING FRAMES FG-5310 Medium Efficiency Filter and Moisture Separator Mounting Frame Alignment FG-5320 Medium Efficiency Filter and Moisture Separator Mounting Frame Flatness FG-5330 Medium Efficiency Filter and Moisture Separator Mounting Frame Dimensions FG-5340 Medium Efficiency Filter and Moisture Separator Mounting Frame Surface Finish FG-5400 WELD INSPECTION FG-5500 COATING INSPECTION FG-6100 GENERAL FG-6200 WELDING FG-6300 CLAMPING DEVICES FG-6400 CLEANING FG-6500 COATING |
343 | NONMANDATORY APPENDIX FG-A DIVISION OF RESPONSIBILITY |
344 | Table FG-A-1000-1 Division of Responsibility |
346 | SECTION FH OTHER ADSORBERS FH-1100 SCOPE FH-1200 PURPOSE FH-1300 APPLICABILITY FH-1400 DEFINITIONS AND TERMS FH-3100 ALLOWABLE MATERIALS FH-3110 Adsorbent FH-3120 Screens FH-3130 Casing FH-3140 Adhesives and Sealants FH-3150 Rivets FH-3200 LIMITS FH-3300 CERTIFICATION OF MATERIALS |
347 | FH-3310 Fabricated Metal Parts FH-3320 Gaskets and Seal Pads FH-3330 Adhesives and Sealants FH-3340 Purchased Hardware Items (Washers and Rivets) FH-4100 GENERAL DESIGN Figure FH-4100-1 Type IV “V” Adsorbers Model (Fluid Seal Version) |
348 | FH-4200 TECHNICAL REQUIREMENTS FH-4210 Design Requirements Figure FH-4100-2 Type IV “V” Bed Adsorbers Model (Gasketed Version) |
349 | FH-4220 Adsorber Beds FH-4230 Case and Assembly Figure FH-4100-3 Type IV “V” Adsorbers Model, Exploded View |
350 | FH-4240 Gaskets FH-4250 Gel Seals FH-4300 STRUCTURAL REQUIREMENTS FH-4310 General FH-4320 Load Definition Figure FH-4100-4 Type IV “U” Bed Adsorbers Model (Gasketed Version) |
351 | FH-4330 Load Combinations FH-4340 Acceptance Criteria FH-5100 DIMENSIONAL INSPECTION FH-5200 WELDING INSPECTION FH-5210 Spot Welds FH-5220 Other Welds FH-5300 QUALIFICATION TESTS FH-5310 Filling Method Qualification FH-5400 ACCEPTANCE TESTS FH-5410 Airflow Resistance Test |
352 | FH-5420 Refrigerant Leak Test FH-6100 DIMENSIONS AND TOLERANCES FH-6200 WELDING FH-6210 Testing and Inspection FH-6220 Repairs FH-6300 FILLING FH-6400 CLEANING FH-7100 PACKAGING Table FH-6100-1 Dimensional Requirements |
353 | FH-7200 LOADING FOR SHIPMENT FH-7300 STORAGE FH-7400 CONTAINERS FH-8100 DOCUMENTATION FH-9100 PERMANENT NAMEPLATE FH-9200 FILLING LABEL |
354 | NONMANDATORY APPENDIX FH-A DIVISION OF RESPONSIBILITY Table FH-A-1000-1 Division of Responsibility |
355 | SECTION FI METAL MEDIA FILTERS |
356 | SECTION FJ LOW EFFICIENCY FILTERS FJ-1100 SCOPE FJ-1200 PURPOSE FJ-1300 APPLICABILITY FJ-1310 Limitations FJ-1320 Responsibility FJ-1400 DEFINITIONS AND TERMS FJ-3100 ALLOWABLE MATERIALS FJ-3110 Filter Media |
357 | FJ-3120 Filter Frame FJ-3130 Separators FJ-3140 Sealants and Adhesives FJ-3150 Gaskets FJ-3200 SPECIAL LIMITATIONS OF MATERIALS FJ-4100 GENERAL DESIGN FJ-4110 MERV 1–5 Filters FJ-4120 MERV 6–8 Filters FJ-4200 DESIGN CRITERIA FJ-4300 STRUCTURAL REQUIREMENTS FJ-5100 INSPECTION PLAN FJ-5110 Inspection Requirements FJ-5120 Rejection and Reinspection FJ-5200 QUALIFICATION TESTING |
358 | FJ-5210 Testing Requirements FJ-5220 Certification FJ-5230 Requalification FJ-5240 Seismic Qualification FJ-6100 GENERAL FJ-6200 MANUFACTURE AND ASSEMBLY FJ-6210 Tolerances FJ-7100 GENERAL FJ-8100 GENERAL FJ-8200 DOCUMENTATION FJ-9100 FILTER MARKINGS |
359 | FJ-9200 PACKAGE MARKINGS |
360 | NONMANDATORY APPENDIX FJ-A DIVISION OF RESPONSIBILITY Table FJ-A-1000-1 Division of Responsibility |
361 | SECTION FK SPECIAL HEPA FILTERS FK-1100 SCOPE FK-1200 PURPOSE FK-1300 APPLICABILITY FK-1310 Special HEPA Filters FK-1320 Limitations FK-1330 Service Life FK-1340 Division of Responsibility FK-1400 DEFINITIONS AND TERMS |
363 | FK-3100 ALLOWABLE MATERIALS FK-3110 Cases, End Caps, Grilles, and Flange Materials FK-3120 Gasket Material FK-3130 Filter Media FK-3140 Face guards FK-3150 Adhesives FK-3160 Separators |
364 | FK-3170 Grilles FK-3200 GENERAL MATERIAL REQUIREMENTS FK-3210 Special Limitations of Materials FK-3220 Alternate Materials FK-4100 GENERAL DESIGN FK-4110 Special HEPA Filters Table FK-4111-1 Type 1 Radial Flow HEPA Filter — Nominal Rating |
365 | Figure FK-4111-1 Type 1 Radial Flow HEPA Filter (Internal Gasket), Midsection View |
366 | FK-4120 Filter End Cap, Grilles, and Flange FK-4130 Filter Pack Figure FK-4111-2 Type 1 Radial Flow HEPA Filter (Internal Gelatinous Seal), Midsection View |
367 | Figure FK-4111-3 Type 1 Radial Flow HEPA Filter (External Gasket), Midsection View |
368 | FK-4140 Gaskets Figure FK-4111-4 Type 1 Radial Flow HEPA Filter (External Gelatinous Seal), Midsection View |
369 | Figure FK-4112-1 Type 2 Axial Flow Circular HEPA Filters |
370 | FK-4150 Grilles FK-4160 Face guards FK-4200 PERFORMANCE REQUIREMENTS FK-4300 STRUCTURAL REQUIREMENTS FK-5100 QUALIFICATION TESTING FOR TYPE 1 RADIAL FLOW FILTERS Table FK-4112-1 Type 2 Axial Flow Circular HEPA Filter — Nominal Rating |
371 | FK-5110 Resistance to Airflow FK-5120 Test Aerosol Particle Penetration Table FK-4200-1 Performance Requirements |
372 | FK-5130 Resistance to Rough Handling FK-5140 Resistance to Pressure Table FK-5100-1 Test Groups and Sequence — Type 1 Radial Flow HEPA Filters Table FK-5140-1 Test Conditions and Requirements |
373 | FK-5150 Resistance to Heated Air FK-5160 Spot Flame Resistance FK-5200 QUALIFICATION TESTING FOR TYPE 2 AXIAL FLOW CIRCULAR FILTERS |
374 | FK-5210 Resistance to Airflow FK-5220 Test Aerosol Particle Penetration FK-5230 Resistance to Rough Handling FK-5240 Resistance to Pressure Table FK-5200-1 Test Groups and Sequence — Type 2 Axial Flow Circular HEPA Filters |
375 | FK-5250 Resistance to Heated Air FK-5260 Spot Flame Resistance FK-5400 QUALIFICATION TESTING FOR TYPE 4 AXIAL FLOW RECTANGULAR FILTERS |
376 | FK-5410 Resistance to Airflow FK-5420 Test Aerosol Particle Penetration FK-5430 Resistance to Rough Handling FK-5440 Resistance to Pressure FK-5450 Resistance to Heated Air Table FK-5400-1 Test Groups and Sequence — Type 4 Axial Flow Rectangular HEPA Filters |
377 | FK-5460 Spot Flame Resistance FK-5500 INSPECTION FK-5600 PRODUCTION TESTING FK-6100 GENERAL FK-6200 MANUFACTURE AND ASSEMBLY FK-6210 Tolerances FK-6220 Media Installation |
378 | FK-6300 WORKMANSHIP FK-8100 RESPONSIBILITY FK-8200 CERTIFICATE OF CONFORMANCE FK-9100 FILTER MARKING FK-9200 PACKAGE MARKING |
379 | NONMANDATORY APPENDIX FK-A DETERMINATION OF HEPA FILTER SERVICE LIFE |
380 | NONMANDATORY APPENDIX FK-B DIVISION OF RESPONSIBILITY Table FK-B-1000-1 Division of Responsibility |
381 | SECTION FL DEEP BED SAND FILTERS FL-1100 SCOPE FL-1200 PURPOSE FL-1300 APPLICABILITY FL-1310 Limitations FL-1320 Division of Responsibility FL-1400 DEFINITIONS AND TERMS |
382 | FL-3100 ALLOWABLE MATERIALS FL-3110 General Requirements FL-3120 Filter Media FL-3130 DBS Filter Structure and Distribution Channels |
383 | FL-3140 Distribution Support Structure FL-3150 Monitoring, Sampling, and Instrumentation Lines FL-3160 Gaskets FL-3200 SPECIAL LIMITATIONS OF MATERIALS FL-3300 CERTIFICATION OF MATERIALS FL-4100 GENERAL DEEP BED SAND FILTER DESIGN FL-4110 DBS Filter Design FL-4120 General Arrangement FL-4200 DESIGN CRITERIA |
384 | FL-4210 Design Features Figure FL-4120-1 Typical DBS Filter Cross Section, DOE-HDBK-1169-2003 |
385 | FL-4220 Monitoring Capabilities FL-4230 Particle Removal Efficiency FL-4300 STRUCTURAL REQUIREMENTS FL-4310 General FL-4320 Natural Phenomena FL-5100 ACCEPTANCE TESTS FL-5110 Filter Media Acceptance Tests |
386 | FL-5120 Distribution Support Structure Acceptance Tests FL-5130 DBS Filter Structure Acceptance Tests FL-5200 INSPECTION PLAN FL-5210 Plan FL-5220 Minimum Filter Media Inspection Requirements FL-5230 Minimum Distribution Support Structure Inspection Requirements |
387 | FL-5240 Minimum Monitoring and Sampling Line Inspection Requirements FL-5250 Minimum DBS Filter Structure Inspection Requirements FL-5260 Rejection and Reinspection FL-5300 QUALIFICATION AND VERIFICATION TESTING FL-5310 Filter Media Verification Testing FL-5320 DBS Filter Performance Qualification and Verification Testing |
388 | FL-6100 GENERAL FL-6200 FABRICATION AND ASSEMBLY FL-6210 Reinforcing Steel and Concrete FL-6220 Distribution Support Structure FL-6230 Structural Steel FL-6300 INSTALLATION FL-6310 Concrete Installation FL-6320 Distribution Support Structure Installation FL-6330 Monitoring and Sampling Line Installation FL-6340 Structural Steel Installation FL-6350 Filter Media Installation FL-6400 TOLERANCES FL-6410 Concrete Tolerances |
389 | FL-6420 Distribution Support Structure Tolerances FL-6430 Monitoring and Sampling Line Tolerances FL-6440 Reinforcing Steel Placing Tolerances FL-6450 Filter Media Tolerances FL-7100 GENERAL REQUIREMENTS FL-7200 FILTER MEDIA FL-8100 GENERAL FL-8110 Scope and Applicability FL-8200 IDENTIFICATION AND COMPLETED MATERIAL FL-9100 DEEP BED SAND FILTER MARKINGS FL-9200 PACKAGE MARKING FL-9300 FILTER MEDIA |
390 | MANDATORY APPENDIX FL-I AIR-AEROSOL MIXING TEST PROCEDURES FL-I-1100 SYSTEM TEST FL-I-1200 SUMMARY OF METHOD FL-I-1300 INJECTION PORT SELECTION CRITERIA FL-I-1400 DOWNSTREAM SAMPLE PORT SELECTION CRITERIA FL-I-4100 GENERAL |
391 | FL-I-4200 DOWNSTREAM SAMPLE PORT QUALIFICATION |
392 | MANDATORY APPENDIX FL-II DEEP BED SAND FILTER IN-PLACE LEAK TEST PROCEDURES FL-II-1100 SUMMARY OF METHOD FL-II-3100 TEST EQUIPMENT FL-II-3200 PROCEDURES |
393 | NONMANDATORY APPENDIX FL-A DIVISION OF RESPONSIBILITY Table FL-A-1000-1 Division of Responsibility |
394 | NONMANDATORY APPENDIX FL-B GUIDELINES FOR DEEP BED SAND FILTERS FL-B-1100 GENERAL FL-B-1200 FILTER MEDIA FL-B-1210 Purity FL-B-1220 Aggregate Types FL-B-1300 DBS FILTER STRUCTURE AND DISTRIBUTION CHANNELS |
395 | FL-B-2100 GENERAL FL-B-2200 DESIGN ATTRIBUTES FL-B-2210 Provision for Inspections and Maintenance FL-B-2220 Allowance of Bypass Channel FL-B-2300 EXAMPLES OF SUPPORT STRUCTURE ARRANGEMENT FL-B-2400 END OF LIFE FL-B-3100 FILTER MEDIA ACCEPTANCE TEST PROCEDURES FL-B-3110 Water Extractable Test |
396 | FL-B-3120 Particle Size Distribution Test Figure FL-B-2300-1 Sand-Filter Cross Sections |
397 | FL-B-3130 Resistance to Airflow Test FL-B-3140 Friable Material Test FL-B-3150 Corrosion-Resistance Test |
398 | FL-B-3200 SEISMIC FL-B-3300 SMOKE LOADING FL-B-4100 GENERAL FL-B-4200 FILTER MEDIA PLACEMENT FL-B-4210 Type A Media FL-B-4220 Types B and C Media FL-B-4230 Types D, E, F, G, and H Media |
399 | SECTION FM HIGH-STRENGTH HEPA FILTERS |
400 | SECTION FN FILTER MEDIA: HIGH EFFICIENCY FN-1100 SCOPE FN-1110 PURPOSE FN-1120 Applicability FN-1130 Definitions and Terms |
401 | FN-3100 ALLOWABLE MATERIALS FN-3110 Fiber FN-3120 Binder FN-3130 Water Repellent FN-3140 Additional Fibers FN-3150 Nonpermissable Materials FN-4100 GENERAL DESIGN REQUIREMENTS FN-4110 Form FN-4120 Size FN-4130 Splices FN-4200 PHYSICAL AND CHEMICAL FN-4210 Airflow Resistance FN-4220 Test Aerosol Penetration FN-4230 Tensile Strength |
402 | FN-4240 Water Repellency FN-4250 Thickness FN-4260 Combustible Material FN-4270 Flexing Characteristics FN-4280 Mildew Resistance FN-4300 WORKMANSHIP FN-5100 QUALIFICATION TESTING FN-5110 Sample FN-5200 TEST PROCEDURES FN-5210 Airflow Resistance and Test Aerosol Penetration FN-5220 Tensile Strength |
403 | FN-5230 Water Repellency FN-5240 Thickness FN-5250 Combustible Material FN-5260 Flexing Characteristics FN-5270 Mildew Resistance |
404 | FN-5280 Workmanship FN-5300 PRODUCTION TESTING FN-5310 Production Lot FN-5320 Sampling FN-5330 Testing FN-6100 GENERAL REQUIREMENTS FN-6200 MANUFACTURE AND ASSEMBLY FN-6210 Tolerances FN-6300 WORKMANSHIP FN-7100 PACKAGING Table FN-5330-1 Filter Media Qualification and Production Tests |
405 | FN-7200 SHIPPING FN-7300 STORAGE FN-8100 RESPONSIBILITY FOR INSPECTION FN-8110 Supplier’s Responsibility FN-8120 Objective Evidence FN-9100 MEDIA ROLL MARKING FN-9200 PACKAGE MARKING |
406 | NONMANDATORY APPENDIX FN-A DIVISION OF RESPONSIBILITY Table FN-A-1000-1 Division of Responsibility |
407 | SECTION IA INSTRUMENTATION AND CONTROLS IA-1100 SCOPE IA-1200 PURPOSE IA-1300 APPLICABILITY IA-1400 DEFINITIONS AND TERMS |
408 | IA-3100 MATERIALS OF CONSTRUCTION IA-3200 NONPERMISSIBLE MATERIALS |
409 | IA-3300 RESTRICTED MATERIALS IA-3400 CERTIFICATION OF MATERIAL IA-4100 GENERAL DESIGN IA-4110 Purpose IA-4120 Design Specification IA-4130 Manufacturer’s Documentation Requirements Table IA-3100-1 Allowable Materials |
410 | IA-4140 Clarification of Code Applicability IA-4200 SINGLE-FAILURE CRITERIA IA-4210 Common Cause Failure IA-4300 SEPARATION CRITERIA IA-4310 Circuits and Devices IA-4320 Instrument-Sensing Lines IA-4400 QUALIFICATION OF EQUIPMENT IA-4410 Normal Operating Conditions IA-4420 Environmental Qualification IA-4430 Seismic Qualification |
411 | IA-4440 Qualification Documentation IA-4500 PANELS IA-4510 General IA-4520 Structures and Enclosure Materials IA-4530 Panel Wiring |
412 | IA-4540 Power Supply and Fuses IA-4550 Panel Piping, Tubing, Valves, and Fittings IA-4560 Instrument Air-Supply Header Assembly IA-4570 Instrument Tags IA-4600 MOUNTED INSTRUMENTS AND SENSORS IA-4700 INTERCONNECTING WIRING FOR SKID-MOUNTED COMPONENTS IA-4800 INSTRUMENT-SENSING LINES AND FIELD-INSTALLED TUBING IA-4810 Pressure Boundary and Mechanical Design Requirements |
413 | IA-4820 Tube Pitch and Condensate Trap IA-4830 Support System IA-4840 Root Valves and Isolation Valves IA-4900 INSTRUMENT SET POINTS IA-4910 IA-4920 IA-5100 GENERAL IA-5110 Procedures for Inspection and Testing IA-5120 Test Reports IA-5200 VISUAL INSPECTION IA-5220 Methods of Visual Examination IA-5230 Written Procedures IA-5300 CALIBRATION AND TESTING IA-5310 Panel-Mounted Instruments |
414 | IA-5320 Local Mounted Instruments IA-5330 Pressure Testing of Tubing and Sensing Lines IA-6100 GENERAL REQUIREMENTS IA-6110 Materials IA-6200 FABRICATION PROCESS IA-6300 WELDING IA-6400 BRAZING IA-6500 CLEANING AND COATING IA-6600 INSTALLATION REQUIREMENTS: HANDLING AND RIGGING IA-6700 MATERIAL IDENTIFICATION IA-7100 GENERAL REQUIREMENTS IA-7200 PACKAGING |
415 | IA-7300 SHIPPING IA-7400 RECEIVING IA-7410 Inspection IA-7420 Disposition IA-7500 STORAGE IA-8100 GENERAL IA-8200 TEST REPORTS AND DATA IA-8210 IA-8220 IA-9100 GENERAL IA-9200 REQUIREMENTS IA-9300 NAMEPLATE SPECIFICATIONS IA-9310 Material IA-9320 Size |
416 | IA-9330 Information |
417 | NONMANDATORY APPENDIX IA-A DIVISION OF RESPONSIBILITY Table IA-A-1000-1 Division of Responsibility |
418 | NONMANDATORY APPENDIX IA-B SAMPLE CHECKLIST FOR VISUAL EXAMINATION OF CONTROL PANELS/ENCLOSURES, INSTRUMENTS, AND CONTROL DEVICES Table IA-B-1000-1 Sample Checklist for Visual Examination of Control Panels/Enclosures, Instruments, and Control Devices |
419 | NONMANDATORY APPENDIX IA-C INSTRUMENTATION FOR NUCLEAR AIR AND GAS TREATMENT SYSTEMS IA-C-1100 PURPOSE IA-C-1200 FUNCTIONAL DESIGN IA-C-1210 General IA-C-1220 Recommended System Parameters Table IA-C-1220-1 Instrumentation for Nuclear Air and Gas Treatment Systems |
420 | Division III Process Gas Treatment SECTION GA HEAT EXCHANGERS GA-1100 SCOPE GA-1200 PURPOSE GA-1300 APPLICABILITY GA-1310 Clarification of Code Applicability GA-1320 Exclusion of Components GA-1330 Interfacing Boundaries GA-1400 DEFINITIONS AND TERMS |
422 | GA-3100 GENERAL REQUIREMENTS GA-3110 Material Specifications GA-3200 MATERIALS FOR HEAT EXCHANGERS GA-3210 Materials for Pressure-Retaining Heat Exchanger Components GA-3220 Materials for Nonmetallic Heat Exchanger Components GA-3300 CERTIFICATION OF MATERIALS GA-3310 General Requirements |
423 | GA-4100 DESIGN SPECIFICATIONS GA-4200 STRUCTURAL REQUIREMENTS FOR HEAT EXCHANGERS GA-4210 General GA-4220 Load Definition GA-4230 Structural Verification |
424 | GA-4300 DESIGN CONDITIONS FOR SHELL-AND-TUBE HEAT EXCHANGERS GA-4310 Design Specification GA-4320 Technical Requirements Figure GA-4311-1 Typical Shell-and-Tube Heat Exchanger |
426 | GA-4400 DESIGN CONDITIONS FOR GASKETED PLATE AND FRAME HEAT EXCHANGERS GA-4410 Design Specification GA-4420 Technical Requirements Figure GA-4411-1 Gasketed Plate and Frame Heat Exchanger |
427 | GA-4430 Structural Requirements GA-4500 DESIGN CONDITIONS FOR BRAZED-PLATE HEAT EXCHANGERS GA-4510 Design Specification Figure GA-4510-1 Brazed-Plate Heat Exchanger |
428 | GA-4520 Technical Requirements GA-4530 Structural Requirements GA-4600 DESIGN CONDITIONS FOR WELDED-PLATE HEAT EXCHANGERS GA-4610 Design Specification |
429 | GA-4620 Technical Requirements Figure GA-4611-1 Typical Welded-Plate Heat Exchanger |
430 | GA-4630 Structural Requirements GA-5100 GENERAL REQUIREMENTS GA-5200 TESTING GA-5210 Performance Verification GA-5220 Leak Testing for Heat Exchangers |
431 | GA-5300 NONDESTRUCTIVE EXAMINATION GA-5310 Material Examination GA-5320 Visual Examination of Brazed Joints GA-6100 GENERAL REQUIREMENTS GA-6200 WELDING GA-6300 BRAZING GA-6400 MECHANICAL JOINING |
432 | GA-6500 CLEANING, FINISHING, AND COATING GA-6510 General GA-6520 Finishing and Surface Preparation GA-6530 Coating and Application GA-6600 INSTALLATION GA-7100 GENERAL REQUIREMENTS |
433 | GA-7200 PACKAGING GA-7210 ASME BPVC, Section III Heat Exchangers GA-7220 ASME BPVC, Section VIII Heat Exchangers GA-7300 SHIPPING GA-7310 ASME BPVC, Section III Heat Exchangers GA-7320 ASME BPVC, Section VIII Heat Exchangers |
434 | GA-7400 STORAGE GA-7410 ASME BPVC, Section III Heat Exchangers GA-7420 ASME BPVC, Section VIII Heat Exchangers GA-7500 HANDLING GA-7510 General Requirements GA-7520 ASME BPVC, Section III Heat Exchangers GA-7530 ASME BPVC, Section VIII Heat Exchangers GA-8100 GENERAL REQUIREMENTS |
435 | GA-8200 DOCUMENTATION AND RETENTION GA-9100 GENERAL REQUIREMENTS GA-9200 HEAT EXCHANGERS GA-9300 INFORMATION ON HEAT EXCHANGER NAMEPLATES GA-9400 NAMEPLATE VISIBILITY GA-9500 DATA REPORTS GA-10100 GENERAL |
436 | NONMANDATORY APPENDIX GA-A DIVISION OF RESPONSIBILITY Table GA-A-1000-1 Division of Responsibility |
437 | NONMANDATORY APPENDIX GA-B DESIGN RECOMMENDATIONS FOR GASKETED PLATE AND FRAME HEAT EXCHANGERS |
438 | SECTION GB NOBLE GAS HOLD-UP EQUIPMENT |
439 | SECTION GC GAS COMPRESSORS AND EXHAUSTERS GC-1100 SCOPE GC-1200 PURPOSE GC-1300 APPLICABILITY GC-1400 DEFINITIONS AND TERMS |
440 | GC-3100 GENERAL GC-3110 Material Stress Values GC-3200 SPECIAL LIMITATIONS ON MATERIALS GC-3300 CERTIFICATION OF MATERIALS GC-3310 Centrifugal and Axial Compressors GC-3320 Rotary Screw and Reciprocating Compressors GC-3400 PURCHASED MATERIALS |
441 | GC-3500 DRIVER MATERIALS GC-4100 DESIGN CONDITIONS GC-4110 Performance GC-4120 Environmental Conditions GC-4130 Loading and Conditions GC-4140 Leakage |
442 | GC-4150 Equipment and Support Boundary GC-4160 Vibration GC-4200 SPECIFICATION DESIGN REQUIREMENTS GC-4210 Compressors |
443 | GC-4220 Drivers GC-4300 CONSTRUCTION GC-4310 General GC-4320 Centrifugal and Axial Compressors GC-4330 Reciprocating Compressors GC-4340 Rotary Screw Compressors GC-4350 Drivers and Drives GC-4360 Accessories |
444 | GC-4400 REPORTS AND CALCULATIONS GC-4410 Performance Rating GC-4420 Equipment Sound Production GC-4430 Structural Verification Considerations |
445 | GC-5100 COMPRESSOR INSPECTION AND TESTING GC-5110 General Testing Requirements GC-5120 Performance Acceptance Tests GC-5130 Sound Tests GC-5140 Mechanical Tests |
446 | GC-5150 Test Results and Reports GC-5200 DRIVER INSPECTION AND TESTING GC-5210 First Unit of a Design GC-5220 Succeeding Units of a Design GC-6100 GENERAL GC-6200 FABRICATION GC-6210 Selection of Materials GC-6300 INSTALLATION GC-7100 GENERAL GC-7200 PACKAGING GC-7300 SHIPPING |
447 | GC-7400 RECEIVING GC-7500 STORAGE GC-8100 GENERAL GC-8200 REQUIRED DOCUMENTATION GC-8210 Certified Performance Curves GC-8220 Material Certification GC-8300 DRAWINGS AND DOCUMENTATION GC-9100 GENERAL GC-9200 REQUIRED NAMEPLATE DATA GC-9210 Compressor Nameplate Data GC-9220 Driver Nameplate Data GC-9300 ACCESSORIES GC-9310 Acceptable Marking Methods GC-9400 INSTALLATION, OPERATION, AND MAINTENANCE MANUALS |
449 | MANDATORY APPENDIX GC-I SHAFT LEAKAGE Table GC-I-1000-1 Maximum Permissible Shaft Leakage Rate, scfm, at Pressure Differential Between Operating and Ambient |
450 | MANDATORY APPENDIX GC-II SYSTEM CONSIDERATIONS GC-II-1100 SYSTEM CHARACTERISTICS GC-II-1200 SYSTEM EFFECTS ON PERFORMANCE GC-II-1300 EQUIPMENT AND SYSTEM MATCHING GC-II-1400 SYSTEM CAPACITY CONTROL GC-II-1500 MULTIPLE-UNIT SYSTEMS |
451 | NONMANDATORY APPENDIX GC-A DIVISION OF RESPONSIBILITY |
452 | Table GC-A-1000-1 Division of Responsibility |
454 | SECTION GD |
455 | SECTION GE HYDROGEN RECOMBINERS AND IGNITERS GE-1100 SCOPE GE-1200 PURPOSE GE-1300 APPLICABILITY GE-1310 Limitations GE-1320 Responsibility GE-1400 DEFINITIONS AND TERMS |
457 | GE-3100 GENERAL REQUIREMENTS GE-3110 Materials GE-3120 Welding and Brazing Material GE-3200 PAR |
458 | GE-3300 IGNITER GE-4100 GENERAL DESIGN GE-4110 Design Specification GE-4200 PAR GE-4300 IGNITER |
459 | GE-4400 STRUCTURAL REQUIREMENTS GE-4410 Load Criteria GE-4420 Stress Criteria GE-4430 Deflection Criteria GE-5100 GENERAL GE-5200 PERFORMANCE TESTING GE-5210 PAR Performance Testing Table GE-4410-1 Load Conditions — Housing and Support |
460 | GE-5220 Igniter Performance Testing GE-6100 GENERAL REQUIREMENTS GE-6200 FABRICATION PROCESSES GE-6300 WELDING GE-6400 BRAZING GE-6500 CLEANING AND COATING GE-6510 General |
461 | GE-6520 Housing Cleaning and Finishing, Coating, and Application GE-6600 INSTALLATION REQUIREMENTS GE-7100 GENERAL REQUIREMENTS GE-7200 PACKAGING GE-7300 SHIPPING GE-7400 STORAGE GE-7500 RECEIVING GE-7600 HANDLING AND RIGGING GE-7700 ASSEMBLY, ERECTION, AND START-UP GE-8100 GENERAL REQUIREMENTS GE-8200 IDENTIFICATION AND CONTROL OF ITEMS GE-8300 DOCUMENTATION |
462 | GE-9100 GENERAL REQUIREMENTS GE-9200 INFORMATION ON NAMEPLATES GE-9300 PAR NAMEPLATE LOCATION GE-9400 DATA REPORTS GE-10100 GENERAL REQUIREMENTS |
463 | NONMANDATORY APPENDIX GE-A DIVISION OF RESPONSIBILITY Table GE-A-1000-1 Division of Responsibility |
464 | NONMANDATORY APPENDIX GE-B ILLUSTRATIONS OF COMPONENTS Figure GE-B-1000-1 Typical PAR |
465 | Figure GE-B-1000-2 Typical Igniter |
466 | NONMANDATORY APPENDIX GE-C PERIODIC TESTING GUIDELINES GE-C-1100 IN-SERVICE TEST REQUIREMENTS GE-C-1110 PAR Testing GE-C-1120 Igniter Testing GE-C-1200 STRUCTURAL INSPECTION |
467 | SECTION GF GAS SAMPLING |
468 | SECTION GG SCRUBBERS |
469 | SECTION GH CYCLONES |
470 | SECTION GI |
471 | SECTION GJ FILTERS |
472 | SECTION GK MIST ELIMINATORS |
473 | SECTION GL |
474 | SECTION GM NOBLE GAS HOLD-UP MEDIA GM-1100 SCOPE GM-1200 APPLICABILITY GM-1300 DEFINITIONS AND TERMS |
475 | GM-3100 ACTIVATED CARBON GM-4100 ACTIVATED CARBON GM-5100 INTRODUCTION GM-5200 ACTIVATED CARBON FOR NOBLE GAS DELAY GM-5210 Physical Testing GM-5220 Performance Testing GM-6100 FABRICATION GUIDELINES GM-7100 GENERAL REQUIREMENTS |
476 | GM-7200 PROTECTION OF CARBON MEDIA GM-7300 PACKAGING GM-7310 General GM-7320 Polyethylene Barrier Material GM-7400 STORAGE GM-7500 HANDLING GM-7600 SHIPPING GM-7610 General GM-7620 Post-loading Inspection GM-7630 Sealed Openings GM-7640 Stacking GM-7700 MARKING |
477 | GM-8100 GENERAL REQUIREMENTS GM-8200 DOCUMENTATION GM-9100 NAMEPLATE, CERTIFICATION, AND SHIPPING INFORMATION |
478 | NONMANDATORY APPENDIX GM-A DIVISION OF RESPONSIBILITY Table GM-A-1000-1 Division of Responsibility |
479 | NONMANDATORY APPENDIX GM-B DETERMINATION OF THE DYNAMIC ADSORPTION COEFFICIENT — RADIOACTIVE TRACER METHOD GM-B-1100 SCOPE GM-B-1200 APPLICABLE DOCUMENTS |
480 | Figure GM-B-3000-1 Schematic of Noble Gas Delay Test Apparatus |
481 | GM-B-7100 SYSTEM DEAD TIME DETERMINATION GM-B-7200 DETERMINATION OF AVERAGE DELAY TIME |
483 | Figure GM-B-7100-1 Typical Traces for Measurement of Delay Time, Tdelay, for Dynamic K Determination |
484 | Division IV Testing Procedures SECTION TA FIELD TESTING OF AIR TREATMENT SYSTEMS TA-1100 SCOPE TA-1200 PURPOSE TA-1300 APPLICABILITY TA-1400 DEFINITIONS AND TERMS |
485 | TA-3100 GENERAL TA-3200 TEST INSTRUMENTS TA-3210 Range Requirements TA-3220 Instrument Fluctuation TA-3230 Evaluation Following Test Instrument Loss, Damage, or Calibration Failure |
486 | TA-3240 Specific Instrument Accuracy Requirements TA-3300 ESTABLISHMENT OF REFERENCE VALUES TA-3400 INSPECTIONS AND TEST REQUIREMENTS Table TA-3200-1 Instrument Accuracy Requirements |
487 | TA-3410 Inspection and Test Parameters TA-3420 System Operating Conditions TA-3430 Procedure Requirements TA-3440 Test Reports TA-3500 GENERIC TESTS TA-3510 Visual Inspections TA-3520 Pressure Boundary Tests TA-3530 Functional Tests |
488 | TA-3600 ACCEPTANCE CRITERIA TA-3610 Visual Inspection TA-3620 Pressure Boundary Tests TA-3630 Functional Tests TA-4100 FAN ACCEPTANCE TESTS TA-4110 Acceptance Test Requirements TA-4120 Visual Inspection Table TA-4110-1 Fan Acceptance Tests |
489 | TA-4130 Pressure Boundary Tests TA-4140 Component Functional Tests TA-4150 System Functional Tests TA-4160 Acceptance Criteria |
490 | TA-4200 DAMPER ACCEPTANCE TESTS TA-4210 Acceptance Test Requirements TA-4220 Visual Inspection TA-4230 Pressure Boundary Tests TA-4240 Component Functional Tests Table TA-4210-1 Damper Acceptance Tests |
491 | TA-4250 System Functional Tests TA-4300 DUCT, HOUSING, AND MOUNTING FRAME ACCEPTANCE TESTS TA-4310 Acceptance Test Requirements TA-4320 Visual Inspection TA-4330 Pressure Boundary Tests TA-4400 REFRIGERATION EQUIPMENT ACCEPTANCE TESTS TA-4410 Acceptance Test Requirements Table TA-4310-1 Duct, Housing, and Frame Acceptance Tests |
492 | TA-4420 Visual Inspection TA-4430 Pressure Boundary Tests TA-4440 Component Functional Tests TA-4450 System Functional Tests Table TA-4410-1 Refrigeration Equipment Acceptance Tests |
493 | TA-4500 CONDITIONING EQUIPMENT ACCEPTANCE TESTS TA-4510 Acceptance Test Requirements TA-4520 Visual Inspection TA-4530 Hydrostatic Test for Hydronic Piping and Coils TA-4540 Component Functional Tests Table TA-4510-1 Conditioning Equipment Acceptance Tests |
494 | TA-4550 System Functional Tests TA-4560 Hydronic System Heating and Cooling Performance Test TA-4570 Acceptance Criteria TA-4600 MOISTURE SEPARATOR, PREFILTER, AND HEPA FILTER BANK ACCEPTANCE TESTS TA-4610 Acceptance Test Requirements Table TA-4610-1 Moisture Separator, Prefilter, and HEPA Filter Acceptance Tests |
495 | TA-4620 Visual Inspection TA-4630 System Functional Tests TA-4640 Acceptance Criteria TA-4700 TYPES II, III, AND IV ADSORBER BANK ACCEPTANCE TESTS TA-4710 Acceptance Test Requirements TA-4720 Visual Inspection TA-4730 Component Functional Tests TA-4740 System Functional Tests Table TA-4710-1 Types II, III, and IV Adsorber Bank Acceptance Tests |
496 | TA-4750 Acceptance Criteria TA-4800 ADSORBENT ACCEPTANCE TESTS TA-4810 Acceptance Test Requirements TA-4820 Laboratory Analysis of Adsorbent TA-4900 INTEGRATED SYSTEM TESTS |
497 | TA-4910 Fan-Integrated System Test Requirements TA-4920 Damper-Integrated System Test Requirements TA-4930 Refrigeration and Conditioning Integrated System Test Requirements TA-4940 HEPA and Adsorber Bank Integrated System Test Requirements TA-4950 Integrated System Habitability Envelope Test Requirements TA-6100 GENERAL TA-6200 PERSONNEL TA-6300 DOCUMENTATION TA-6310 Procedures |
498 | TA-6320 Reports |
499 | MANDATORY APPENDIX TA-I VISUAL INSPECTION CHECKLIST TA-I-1100 FAN INSPECTION ITEMS TA-I-1200 DAMPER INSPECTION ITEMS TA-I-1300 DUCT, HOUSING, AND MOUNTING FRAME INSPECTION ITEMS TA-I-1400 REFRIGERATION EQUIPMENT INSPECTION ITEMS |
500 | TA-I-1500 CONDITIONING EQUIPMENT INSPECTION ITEMS TA-I-1600 MOISTURE SEPARATOR BANK, PREFILTER BANK, AND HEPA FILTER BANK INSPECTION ITEMS TA-I-1700 TYPES II, III, AND IV ADSORBER BANK INSPECTION ITEMS |
501 | MANDATORY APPENDIX TA-II STRUCTURAL CAPABILITY TEST PROCEDURES TA-II-1100 SUMMARY OF METHOD |
502 | MANDATORY APPENDIX TA-III DUCT AND HOUSING LEAK TEST PROCEDURES TA-III-1100 SUMMARY OF METHOD TA-III-4100 CONSTANT PRESSURE TEST |
503 | TA-III-4200 PRESSURE DECAY TEST TA-III-4300 ACCEPTANCE CRITERIA TA-III-4400 BUBBLE LEAK LOCATION METHOD TA-III-4500 AUDIBLE LEAK LOCATION METHOD |
504 | MANDATORY APPENDIX TA-IV AIRFLOW DISTRIBUTION TEST PROCEDURES TA-IV-1100 SUMMARY OF METHOD |
505 | MANDATORY APPENDIX TA-V AIR-AEROSOL MIXING TEST PROCEDURES TA-V-1100 SYSTEM TEST TA-V-1200 SUMMARY OF METHOD TA-V-1300 INJECTION PORT SELECTION CRITERIA TA-V-1400 DOWNSTREAM SAMPLE PORT SELECTION CRITERIA TA-V-4100 GENERAL |
506 | TA-V-4200 DOWNSTREAM SAMPLE PORT QUALIFICATION |
507 | MANDATORY APPENDIX TA-VI HEPA FILTER BANK IN-PLACE LEAK TEST PROCEDURES TA-VI-1100 SUMMARY OF METHOD |
508 | MANDATORY APPENDIX TA-VII ADSORBER BANK IN-PLACE LEAK TEST PROCEDURES TA-VII-1100 SUMMARY OF METHOD |
509 | MANDATORY APPENDIX TA-VIII REFRIGERANT PIPING AND COIL SYSTEM LEAK TEST PROCEDURES TA-VIII-1100 SUMMARY OF METHOD TA-VIII-4100 LEAK TEST PROCEDURES TA-VIII-4200 EVACUATION AND DEHYDRATION PROCEDURE |
511 | NONMANDATORY APPENDIX TA-A MOUNTING FRAME PRESSURE LEAK TEST PROCEDURES TA-A-1100 SUMMARY OF METHOD |
512 | NONMANDATORY APPENDIX TA-B CORRECTIVE ACTION GUIDANCE |
513 | NONMANDATORY APPENDIX TA-C CHALLENGE GAS AND AEROSOL SUBSTITUTE SELECTION CRITERIA TA-C-1100 ALTERNATIVE CHALLENGE GASES TA-C-1200 ALTERNATIVE CHALLENGE AEROSOLS |
514 | SECTION TB FIELD TESTING OF GAS-PROCESSING SYSTEMS |