ASME B30.19 – 2016(R2021) Cableways

Published By Publication Date Number of Pages
ASME 2016 38
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

B30.19 applies to the construction, installation, operation inspection, and maintenance of all load transporting hoisting and lowering cable supported systems operating on and supported from track cable(s). This volume does not apply to skyline systems as used in the logging industry or slackline systems used for excavating.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
5 FOREWORD
7 ASME B30 COMMITTEE ROSTER
9 B30 STANDARD INTRODUCTION
SECTION I: SCOPE
SECTION II: SCOPE EXCLUSIONS
SECTION III: PURPOSE
SECTION IV: USE BY REGULATORY AGENCIES
SECTION V: EFFECTIVE DATE
10 SECTION VI: REQUIREMENTS AND RECOMMENDATIONS
SECTION VII: USE OF MEASUREMENT UNITS
SECTION VIII: REQUESTS FOR REVISION
SECTION IX: REQUESTS FOR INTERPRETATION
SECTION X: ADDITIONAL GUIDANCE
12 ASME B30.19-2016 SUMMARY OF CHANGES
14 CABLEWAYS
Chapter 19-0 Scope, Definitions, Personnel Competence, and References
SECTION 19-0.1: SCOPE OF B30.19
SECTION 19-0.2: DEFINITIONS
19-0.2.1 Types of Cableways
19-0.2.2 General
15 SECTION 19-0.3: PERSONNEL COMPETENCE
16 SECTION 19-0.4: REFERENCES
17 Figures
Fig. 19-0.2.1-1 Fixed Cableway
18 Fig. 19-0.2.1-2 Luffing Cableway
19 Fig. 19-0.2.1-3 Parallel Cableway
20 Fig. 19-0.2.1-4 Radial Cableway
21 Fig. 19-0.2.2-1 Two-Drum Cableway Hoist
Fig. 19-0.2.2-2 Trolley Hoist Unit
Fig. 19-0.2.2-3 Multisheave Endless Rope Trolley Hoist Unit
22 Fig. 19-0.2.2-4 Luffing Hoist Unit
23 Chapter 19-1 Construction and Characteristics
SECTION 19-1.1: LOAD RATINGS
19-1.1.1 Basis
19-1.1.2 Load Rating Chart
SECTION 19-1.2: DESIGN AND MANUFACTURE
19-1.2.1 General
19-1.2.2 Structures
19-1.2.3 Foundations
SECTION 19-1.3: CONSTRUCTION AND ERECTION
19-1.3.1 Foundations, Anchors, and Guys
24 19-1.3.2 Rigging and Reeving
19-1.3.3 Ropes
19-1.3.4 Sheaves
19-1.3.5 Hoists
25 19-1.3.6 Guards for Moving Parts
19-1.3.7 Load Hook and Lower Load Block Assembly
19-1.3.8 Slack Carriers and Upper Load Block Carriage
19-1.3.9 Assembly Construction Procedure
26 19-1.3.10 Cabs and Machinery Enclosures
19-1.3.11 Controls
19-1.3.12 Monitoring Devices
19-1.3.13 Traveling Towers
27 Fig. 19-1.3.12-1 Standard Hand Signals for Controlling Cableway Operations
28 19-1.3.14 Aids to Aviation
19-1.3.15 Personal Protection Ropes
19-1.3.16 Luffing Hoist
29 Chapter 19-2 Inspection, Testing, and Maintenance
SECTION 19-2.1: INSPECTION
19-2.1.1 Inspection Classification
19-2.1.2 Frequent Inspection
19-2.1.3 Periodic Inspection
19-2.1.4 Cableways Not in Regular Use
30 SECTION 19-2.2: TESTING
19-2.2.1 Operational Tests
19-2.2.2 Load Test
SECTION 19-2.3: MAINTENANCE
19-2.3.1 Preventive Maintenance
19-2.3.2 Maintenance Procedures
19-2.3.3 Adjustments and Repairs
31 19-2.3.4 Lubrication
SECTION 19-2.4: ROPE INSPECTION, REPLACEMENT, AND MAINTENANCE
19-2.4.1 General
19-2.4.2 Inspection
19-2.4.3 Rope Replacement
32 19-2.4.4 Rope Maintenance
33 Chapter 19-3 Operation
SECTION 19-3.1: OPERATOR QUALIFICATIONS AND OPERATING PRACTICE
19-3.1.1 Operators
19-3.1.2 Qualifications for Operators
19-3.1.3 Operating Practices
34 SECTION 19-3.2: OPERATING PRACTICES
19-3.2.1 Handling the Load
19-3.2.1.1 Size of Load
19-3.2.1.2 Attaching the Load
19-3.2.1.3 Moving the Load
19-3.2.1.4 Holding the Load
19-3.2.2 Personnel Lifting
35 SECTION 19-3.3: SIGNALS
19-3.3.1 Standard Signals
19-3.3.2 Hand Signals
19-3.3.3 Special Signals
19-3.3.4 Instructions
SECTION 19-3.4: MISCELLANEOUS
19-3.4.1 Ballast or Counterweight
19-3.4.2 Aerial Marking
19-3.4.3 Hoist, Ropes, and Rope Anchors
19-3.4.4 Operating Near Electric Power Lines
36 19-3.4.5 Cabs
19-3.4.6 Refueling
19-3.4.7 Fire Extinguishers
Fig. 19-3.4.4-1 Danger Zone for Cableways and Lifted Loads Operating Near Electrical Transmission Lines
Table
Table 19-3.4.4-1 Required Clearance for Normal Voltage in Operation Near High Voltage Power Lines
37 19-3.4.8 Cableway Lockout/Tagout
ASME B30.19 2016 R2021