ASME B89.1.14 2018 R2023

$98.04

ASME B89.1.14 – 2018(R2023): Calipers

Published By Publication Date Number of Pages
ASME 2018
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Standard provides the essential requirements for the specification, verification, and calibration of calipers, including vernier, dial, electronic digital, and specialty calipers. ISO 13385-1 provides for the international definition of the design and metrological characteristics of calipers important in the specification, manufacture, and purchase of calipers; however, ISO 13385-1 does not provide specification values, detailed test methods, or sufficient discussion of traceability and measurement uncertainty to ensure consistent practice in the calibration of calipers. This Standard is intended to complement, not contradict, ISO 13385-1.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
5 FOREWORD
6 COMMITTEE ROSTER
7 CORRESPONDENCE WITH THE B89 COMMITTEE
10 1 SCOPE
2 DEFINITIONS
3 REFERENCES
4 CALIPER DESIGN
4.1 General
4.2 Least Count
5 MAXIMUM PERMISSIBLE ERRORS
5.1 General
11 5.2 Operator
5.3 Zero Setting
5.4 Indication
5.5 Temperature
5.6 Measurement Uncertainty and Decision Rules
5.7 Traceability
5.8 Specifications
5.9 Specialty Calipers
5.10 Metrological Characteristics
12 Tables
Table 5.8-1 Maximum Permissible Errors of Calipers With Measuring Range Up to 1 000 mm (40 in.)
13 Table 5.10.4-1 Number of Test Points for EMPE
14 Figures
Figure 5.10.4-1 Testing Partial Surface Contact Error — Example Test Points on Two Calipers Showing Different Lengths and Different Distances From the Beam
Figure 5.10.6-1 Testing Line Contact Error
15 Figure 5.10.7-1 Testing Scale Shift Error — Inside Measurement
Figure 5.10.7-2 Testing Scale Shift Error — Depth Measurement
Figure 5.10.7-3 Testing Scale Shift Error — Step Measurement
Figure 5.10.8-1 Effect of Crossed Knife-Edge Internal Measuring Faces
Figure 5.10.8-2 Testing Scale Shift Error — Internal Measurement With Crossed Knife-Edge
16 NONMANDATORY APPENDIX A GOOD OPERATING PROCEDURES
A-1 GENERAL
A-2 VERNIER CALIPER
17 A-3 DIAL CALIPER
A-4 ELECTRONIC DIGITAL CALIPER
18 NONMANDATORY APPENDIX B ENVIRONMENTAL CONSIDERATIONS
B-1 GENERAL
B-2 TEMPERATURE
B-3 HUMIDITY
B-4 CLEANLINESS
19 NONMANDATORY APPENDIX C MEASUREMENT UNCERTAINTY
C-1 GENERAL
C-2 SOURCES OF ERROR
C-3 COMMON PRACTICES
C-4 EXAMPLE UNCERTAINTY BUDGET
21 Table C-4.1-1 Uncertainty Budget for Performance Verification of the Partial Surface Contact Error for a 0-mm to 150-mm Digital Caliper
C-5 CONCLUSION
ASME B89.1.14 2018 R2023
$98.04