Shopping Cart

No products in the cart.

ASME BPVC III 1 ND 2017

$7.80

ASME BPVC – III – 1 – ND -2017 BPVC Section III, Rules for Constructions of Nuclear Facility Components, Division 1, Subsection ND, Class 3 Components

Published By Publication Date Number of Pages
ASME 2017 339
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
53 ND-1132.2-1 Attachments in the Component Support Load Path That Do Not Perform a Pressure-Retaining Function
54 ND-1132.2-2 Attachments That Do Not Perform a Pressure-Retaining Function and Are Not in the Component Support Load Path
55 ND-1132.2-3 Attachments That Perform a Pressure-Retaining Function
63 ND-2311-1 Exemptions From Impact Testing Under ND-2311(a)(8)
64 ND-2331(a)-1 Required Cv Lateral Expansion Values for Pressure-Retaining Material (Except Bolting)
65 ND-2331(a)-2 Required Cv Energy Values for Pressure-Retaining Material (Except Bolting)
ND-2333-1 Required Cv Values for Bolting Material
67 ND-2432.1-1 Sampling of Welding Materials for Chemical Analysis
68 ND-2432.2-1 Welding Material Chemical Analysis
69 ND-2433.1-1 Delta Ferrite Content
74 ND-2571-1 Required Examinations
77 ND-2575.2-1 Typical Pressure-Retaining Parts of Pumps and Valves
86 ND-3133.4-1 Length L of Some Typical Conical Sections
88 ND-3133.7-1 Chart for Determining Wall Thickness of Tubes Under External Pressure
89 ND-3321-1 Stress Limits for Design and Service Loadings
90 ND-3321-2 Classification of Stress in Vessels for Some Typical Cases
92 ND-3324.2-1 Principal Dimensions of Typical Heads
ND-3324.2-1 Values of Factor K
95 ND-3324.8(b)-1 Values of Factor M
96 ND-3324.11(a)(6)-1 Large Head Openings, Reverse Curve, and Conical Shell Reducer Sections
ND-3324.11(b)(2)-1 Values of Δ for Junctions at the Large Cylinder for α ≤ 30 deg
97 ND-3324.11(b)(3)-1 Values of Δ for Junctions at the Small Cylinder for α ≤ 30 deg
99 ND-3325-1 Some Acceptable Types of Unstayed Flat Heads and Covers
102 ND-3326.1-1 Spherically Dished Covers With Bolting Flanges
104 ND-3329.1(e)-1 Acceptable Proportions for Ends or Through Stays
105 ND-3329.6(b)-1 Example of Tube Spacing With Pitch of Holes Equal in Every Row
106 ND-3329.6(b)-2 Example of Tube Spacing With Pitch of Holes Unequal in Every Second Row
ND-3329.6(b)-3 Example of Tube Spacing With Pitch of Holes Varying in Every Second and Third Row
ND-3329.6(d)-1 Example of Tube Spacing With Tube Holes on Diagonal Lines
107 ND-3329.6(d)-2 Diagram for Determining the Efficiency of Longitudinal and Diagonal Ligaments Between Openings in Cylindrical Shells
109 ND-3329.6(g)-1 Diagram for Determining Equivalent Longitudinal Efficiency of Diagonal Ligaments
110 ND-3332.2-1 Chart for Determining Value of F
ND-3332.2-1 Values of Spherical Radius Factor K1
112 ND-3335.1(b)-1 Some Representative Configurations Describing the te Reinforcement Dimension
113 ND-3335.2-1 Arrangement of Multiple Openings
114 ND-3335.3(b)-1 Minimum Depth for Flange of Flued Openings
115 ND-3351-1 Welded Joint Locations Typical of Categories A, B, C, and D
116 ND-3352-1 Typical Butt Joints
120 ND-3358.1(a)-1 Heads Attached to Shells
122 ND-3361.1-1 Butt Welding of Plates of Unequal Thicknesses
ND-3361.3(a)-1 Minimum Number of Pipe Threads for Connections
125 ND-3416-1 Stress and Pressure Limits for Design and Service Loadings
126 ND-3423-1 Typical Single Volute Casing
ND-3423-2 Typical Double Volute Casing
127 ND-3433.4-1 Minimum Tangential Inlet and Outlet Wall Thicknesses
ND-3436(c)-1 External and Internal Attachments
128 ND-3441.1-1 Type a Pump
ND-3441.1-2 Type a Pump
129 ND-3441.1(a)-1 Type A Pump
ND-3441.2-1 Type B Pump
ND-3441.3-1 Type C Pump
130 ND-3441.3-2 Type C Pump
131 ND-3441.4(a)-1 Type D Pump
ND-3441.5-1 Type E Pump
ND-3441.6(a)-1 Type F Pump
132 ND-3441.7(a)-1 Axially Split Casing, Volute Pump, Type G
ND-3441.7(a)-2 Axially Split Casing, Volute Pump, Type G
133 ND-3441.7(c)-1 Axially Split Casing, Volute Pump, Type G
ND-3441.7(c)(2)-1 Typical Section of Type G Pump
ND-3441.7(c)(2)-2 Typical Section of Type G Pump
134 ND-3441.7(c)(2)-3 Typical Loads on Type G Pump
135 ND-3441.8-1 Longitudinal Section Through Type H Pump
136 ND-3441.8-2 Transverse Section Through Type H Pump
137 ND-3441.9-1 Type K Pump
138 ND-3441.9-2 Type K Pump
141 ND-3441.10-1 Type L Pump
144 ND-3441.10-2 Type L Pump Bowl
146 ND-3451(a)-1 Horizontal Single‐Acting Power Pump Liquid Ends
149 ND-3521-1 Typical Sections of Valve Bodies
150 ND-3521-1 Level A, Level B, Level C, and Level D Service Limits
152 ND-3591.1-1 Typical Pressure Relief Devices
153 ND-3591.1-2 Typical Pressure Relief Devices
154 ND-3592.2(b)-1 Class 3 Pressure Relief Devices: Level B, C, and D Service Loadings
155 ND-3595.3-1 Valve Nozzle
156 ND-3611.2(e)-1 Stress Range Reduction Factors
158 ND-3613.4-1 Weld Joint Efficiency Factor
159 ND-3622-1 Examples of Reversing and Nonreversing Dynamic Loads
160 ND-3641.1(a)-1 Values of A
162 ND-3643.2(b)-1 Typical Welded Branch Connections
163 ND-3643.2(b)-2 Typical Right Angle Branch Connections Made Using a Fillet Weld or a Partial Penetration Weld
165 ND-3643.3(c)(1)-1 Reinforcement of Branch Connections
166 ND-3643.3(c)(1)-2 Some Representative Configurations Describing the te Reinforcement Dimension
168 ND-3643.4(a)-1 Reinforced Extruded Outlets
171 ND-3647.2-1 Types of Permanent Blanks
176 ND-3653.3-1 Reducing or Full Outlet Branch Connections, or Tees
183 ND-3673.2(b)-1 Stress Indices, Flexibility, and Stress Intensification Factors
189 ND-3673.2(b)-2 Branch Connection Nomenclature
192 ND-3821.5-1 Design and Service Limits
196 ND-3852.7-1 Allowable Tensile Stresses for Roof Supports
197 ND-3852.7-2 Allowable Axial Compression Stresses for Roof Supports
199 ND-3852.7-3 Allowable Bending Stresses for Roof Supports
201 ND-3852.7-4 Allowable Shear Stresses for Roof Supports
202 ND-3852.7-5 Allowable Shear and Tension Stresses for Bolts for Roof Supports
ND-3852.7-6 Allowable Bearing Stresses for Bolts for Roof Supports
204 ND-3861-1 Roof Manholes
205 ND-3862(a)-1 Flanged Roof Nozzles
ND-3861-1 Roof Manholes
206 ND-3862(a)-2 Screwed or Socket Weld Roof Nozzles
ND-3862(a)-1 Flanged Roof Nozzles
207 ND-3863-1 Welded Bottom Outlet Elbow
ND-3862(a)-2 Screwed or Socket Weld Roof Nozzles
208 ND-3863-1 Welded Bottom Outlet Elbow
ND-3865-1 Platforms and Walkways
ND-3865-2 Stairways
209 ND-3865-3 Stairway Rise, Run, and Angle Relationships
210 ND-3921.8-1 Design and Service Limits for Steel Tanks
212 ND-3922.1-1 Biaxial Stress Chart for Combined Tension and Compression, 30,000 psi to 38,000 psi (205 MPa to 260 MPa) Yield Strength Steels
213 ND-3922.1-2 Reduction of Design Stresses Required to Allow for Biaxial Stresses of Opposite Sign
215 ND-3923.1-1 Maximum Allowable Stress Values for Structural Members
219 ND-3932.1-1 Some Typical Free Body Diagrams for Certain Shapes of Tanks
220 ND-3932.2(d)-1 Factors for Determining Values of R1 and R2 for 2:1 Ellipsoidal Roofs and Bottoms
223 ND-3933.4(a)-1 Compression Ring Region
225 ND-3933.5(d)-1 Permissible Details of Compression Ring Construction
227 ND-3933.5(h)-1 Some Values for k Based on n, θ
230 ND-3944-1 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 25 ksi at Temperatures ≤ 300°F
231 ND-3944-1M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 175 MPa at Temperatures ≤ 150°C
232 ND-3944-2 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 30 ksi at Temperatures ≤ 300°F
233 ND-3944-2M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 210 MPa at Temperatures ≤ 150°C
234 ND-3944-3 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 35 ksi at Temperatures ≤ 300°F
235 ND-3944-3M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 245 MPa at Temperatures ≤ 150°C
236 ND-3944-4 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 40 ksi at Temperatures ≤ 300°F
237 ND-3944-4M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 280 MPa at Temperatures ≤ 150°C
238 ND-3944-5 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 45 ksi at Temperatures ≤ 300°F
239 ND-3944-5M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 315 MPa at Temperatures ≤ 150°C
240 ND-3944-6 Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 50 ksi at Temperatures ≤ 300°F
241 ND-3944-6M Design Factor Times Allowable Axial Membrane Compressive Stress Versus Radius Over Thickness for Ferrous Materials With Yield Strengths of 350 MPa at Temperatures ≤ 150°C
242 ND-3947-1 Meridional Straightness Tolerance
246 ND-4221.1-1 Maximum Difference in Cross‐Sectional Diameters
247 ND-4221.2(a)-1 Maximum Permissible Deviation e From a True Circular Form
248 ND-4221.2(a)-2 Maximum Arc Length for Determining Plus or Minus Deviation
249 ND-4232(a)-1 Maximum Allowable Offset in Final Welded Joints
250 ND-4233-1 Butt Weld Alignment and Mismatch Tolerances for Unequal I.D. and O.D. When Components Are Welded From One Side and Fairing Is Not Performed
252 ND-4243-1 Attachment of Pressure Parts to Plates to Form a Corner Joint
254 ND-4243.1-1 Typical Flat Heads, and Supported and Unsupported Tubesheets With Hubs
255 ND-4244(a)-1 Nozzles, and Branch and Piping Connections Joined by Full Penetration Butt Welds
256 ND-4244(b)-1 Nozzles, and Branch and Piping Connections Joined by Full Penetration Corner Welds
257 ND-4244(c)-1 Deposited Weld Metal Used as Reinforcement of Openings for Nozzles, and Branch and Piping Connections
258 ND-4244(d)-1 Some Acceptable Types of Welded Nozzles, and Branch and Piping Connections
259 ND-4244(e)-1 Some Acceptable Types of Welded Nozzles
260 ND-4244(e)-2 Some Acceptable Types of Small Fittings
261 ND-4244(f)-1 Tube Connections
262 ND-4244(g)-1 Some Acceptable Types of Welded Nozzles, and Branch and Piping Connections
263 ND-4245-1
264 ND-4245-1 Attachment Welds
266 ND-4246.1(a)-1 Typical Bottom and Bottom‐to‐Shell Joints
267 ND-4246.3-1 Typical Roof and Roof‐to‐Shell Joints
268 ND-4246.5-1 Roof Manholes
269 ND-4246.5-2 Flanged Roof Nozzles
ND-4246.5-3 Screwed or Socket Weld Roof Nozzles
270 ND-4246.5-4 Welded Bottom Outlet Elbow
271 ND-4247.6(d)-1 Minimum Size for Fillet Welds
272 ND-4250-1 Welding End Transitions Maximum Envelope
279 ND-4427-1 Fillet and Socket Weld Details and Dimensions
280 ND-4433-1 Types of Attachment Welds
281 ND-4437.2(b)-1 Some Acceptable Methods of Attaching Stiffening Rings to Shells of Cylindrical Vessels Subjected to External Pressure
283 ND-4470-1 Welded Stayed Construction
284 ND-4511-1 Brazed Connections for Appurtenances and Piping, NPS 4
ND-4524-1 Maximum Design Temperatures for Brazing Filler Metal, °F (°C)
286 ND-4622.1-1 Mandatory Requirements for Postweld Heat Treatment of Welds
287 ND-4622.4(c)-1 Alternative Holding Temperatures and Times
288 ND-4622.7(b)-1 Exemptions to Mandatory PWHT
291 ND-4730-1 Penetration Assembly
292 ND-4810(c)-1 Permissible Attachment Welds for Bellows
294 ND-5211.2-1 Thickness Above Which Full Radiographic Examination of Butt-Welded Joint is Mandatory
325 ND-7734.2(a)-1 Values of F for Nonchoking Flow
329 ND-7754.2(a)-1 Values of F for Nonchoking Flow
ASME BPVC III 1 ND 2017
$7.80