ASME BPVC IV 2013
$377.00
ASME BPVC – IV -2013 BPVC Section IV, Rules for Construction of Heating Boilers
Published By | Publication Date | Number of Pages |
ASME | 2013 | 318 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
46 | HG-307 Some Acceptable Types of Unstayed Flat Heads and Covers |
50 | HG-309 Spherically Dished Steel Plate Covers with Bolting Flanges |
52 | HG-312.4 Acceptable Type of Ring Reinforced Furnace |
53 | HG-312.7 Connection Between Plain and Corrugated Furnace |
54 | HG-312.8 Acceptable Type of Semicircular Furnace Reinforcement |
56 | HG-321 Chart for Determining Values of F HG-321 Values of Spherical Radius Factor K1 |
58 | HG-326.1 Some Representative Configurations Describing the Reinforcement Dimension, te, and the Finished Opening Dimension, d |
59 | HG-326.2 Nomenclature and Formulas for Reinforced Openings |
62 | HG-340.1 Pitch of Staybolts Adjacent to Upper Corners of Fireboxes HG-340.2 Acceptable Proportions for Ends of ThroughāStays HG-340.3 Examples of Acceptable Corner Welds for Pressures Not Over 30 psi |
63 | HG-340 Allowable Pitch of Stays, in. (mm) (Limited by HG-340.3) |
65 | HG-343 Details of Installation of Diagonal Stays |
66 | HG-345.1(a) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
67 | HG-345.1(b) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
68 | HG-350.1 Example of Tube Spacing with Pitch of Holes Equal in Every Row |
69 | HG-350.2 Example of Tube Spacing with Pitch of Holes Unequal in Every Second Row HG-350.3 Example of Tube Spacing with Pitch of Holes Varying in Every Second and Third Row |
70 | HG-350.4 Example of Tube Spacing with Tube Holes on Diagonal Lines |
71 | HG-360 Permitted OāRing Materials HG-370 Minimum Thickness of Material for Threaded Connections to Boilers |
72 | HG-400.1 Minimum Pounds of Steam per Hour (kg/hr) per Square Foot (Meter) of Heating Surface |
75 | HG-402 Official Certification Mark to Denote the American Society of Mechanical Engineersā Standard |
85 | HG-530.1 Official Certification Mark to Denote the American Society of Mechanical Engineersā Standard HG-530.2 Steam and Water Boilers Form of Stamping on Completed Boilers or their Nameplates |
86 | HG-530.3 Boilers Suitable for Water Only HG-530.4 Steam and Water Boilers |
87 | HG-530.5 Boilers Suitable for Water Only HG-530.6 Boilers Suitable for Water Only |
88 | HG-530.7 Steam and Water Boilers HG-530.8 Boilers Suitable for Water Only |
98 | HG-703.1(a) Steam Boilers in Battery ā Pumped Return ā Acceptable Piping Installation |
99 | HG-703.1(b) Steam Boilers in Battery ā Gravity Return ā Acceptable Piping Installation |
100 | HG-703.2 Hot Water Boilers in Battery ā Acceptable Piping Installation |
102 | HG-709.2 Expansion Tank Capacities for Forced Hot Water Systems |
103 | HG-715 Size of Bottom Blowoff Piping, Valves, and Cocks |
104 | HG-725(a) Spacing and Weld Details for Supporting Lugs in Pairs on HorizontalāReturn Tubular Boiler |
105 | HG-725(b) Welded Bracket Connection for HorizontalāReturn Tubular Boiler |
112 | HF-300.1 Maximum Allowable Stress Values for Ferrous Materials, ksi |
118 | HF-300.1M Maximum Allowable Stress Values for Ferrous Materials, MPa |
124 | HF-300.2 Maximum Allowable Stress Values for Nonferrous Materials, ksi |
129 | HF-300.2M Maximum Allowable Stress Values for Nonferrous Materials, MPa |
137 | HW-701.1 Butt Welding of Plates of Unequal Thickness |
139 | HW-701.3 Some Forms of Attachments of Pressure Parts to Flat Plates to Form a Corner Joint (Tee Joint) |
140 | HW-710.4(a) Some Acceptable Types of Diagonal Stays for Installation by Welding HW-710.4(b) Unacceptable Types of Diagonal Stays for Installation by Welding |
142 | HW-715.1 Heads Attached to Shells HW-713 Firetube Extension Through Tubesheets for Welded Construction |
144 | HW-731 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells, Drums, and Headers |
147 | HW-740 ThreeāPly Joint Assemblies |
149 | HW-745 TwoāPly Joint Assemblies |
159 | HB-1305 Recommended Joint Clearances at Brazing Temperature |
164 | HC-205.1 Dimensions of Tensile Test Specimen HC-206.1 Cast Test Bars |
166 | HC-210 Correction Factors for Transverse Test Bars HC-213 Pipe Plug Size for Minimum Wall Thickness |
167 | HC-300 Maximum Allowable Stress Values in Tension for Cast Iron, ksi (MPa) |
168 | HC-311 Spherically Shaped Covers with Bolting Flanges |
192 | HLW-300 Maximum Allowable Stress Values in Tension for Lined Water Heater Materials, ksi (MPa) |
194 | HLW-301 Maximum Allowable Stress Values in Tension for Unlined Water Heater Materials ksi (MPa) |
197 | HLW-401.1 Butt Welding of Plates of Unequal Thickness |
198 | HLW-401.2 Typical Corner Joints |
199 | HLW-411 Typical Water Heater Welded Joints |
201 | HLW-413 Tubes Attached by Welding |
203 | HLW-415 Heads Attached to Shells |
204 | HLW-431.1 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
206 | HLW-431.5 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
208 | HLW-432.1 Some Acceptable Types of Brazed Fittings, Nozzles, and Other Connections to CopperāLined Shells and Heads |
214 | HLW-602.1 Official Symbol to Denote The American Society of Mechanical Engineersā Standard HLW-602.2 Form of Stamping on Completed Water Heaters |
218 | HLW-809.1 Expansion Tank Capacities for a Water Heater |
219 | HLW-809.1 A Typical Acceptable Piping Installation for Storage Water Heaters in Battery |
220 | HLW-809.2 A Typical Acceptable Piping Installation for Flow Through Water Heater with Provisions for Piping Expansion |
230 | 8-1 Certificate of Conformance for Reapplication of the Certification Mark |
256 | L-1 Guide for the Preparation of Section IV Manufacturerās Data Report Forms |
259 | H-2 Manufacturerās Data Report for all Types of Boilers Except Watertube and those Made of Cast Iron |
261 | H-3 Manufacturerās Data Report for Watertube Boilers |
263 | H-4 Manufacturerās Partial Data Report |
265 | H-5 Manufacturerās Master Data Report for Boilers Constructed from Cast Iron |
267 | H-5A Manufacturerās Master Data Report for Boilers Constructed from Cast Aluminum |
269 | H-6 Manufacturerās Data Report Supplementary Sheet |
270 | HC-1 Manufacturerās Material Certificate of Conformance for Cast Iron Boiler Sections |
271 | HC-2 Manufacturerās Material Certificate of Conformance for Hydrostatic Testing of Cast Iron Boiler Sections |
272 | HA-1 Manufacturerās Material Certificate of Conformance for Cast Aluminum Boiler Sections |
273 | HA-2 Manufacturerās Material Certificate of Conformance for Hydrostatic Testing of Cast Aluminum Boiler Sections |
274 | HLW-6 Manufacturerās Data Report for Water Heaters or Storage Tanks |
276 | HLW-7 Manufacturerās Partial Data Report for Water Heaters and Storage Tanks |
278 | HLW-8 Manufacturerās Master Data Proof Test Report for Water Heaters or Storage Tanks |
284 | HV-1 Manufacturerās Certificate of Conformance for Pressure Relief Valves |
307 | INTERPRETATIONS Volume 62 |