Shopping Cart

No products in the cart.

ASME BPVC VI 2010

$377.00

ASME BPVC – VI -2010 BPVC Section VI, Recommended Rules for the Care and Operation of Heating Boilers

Published By Publication Date Number of Pages
ASME 2010 120
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
11 FOREWORD
13 STATEMENT OF POLICY
14 PERSONNEL
26 SUMMARY OF CHANGES
27 1. GENERAL
1.01 SCOPE
1.02 USE OF ILLUSTRATIONS
1.03 MANUFACTURER’S INFORMATION
1.04 REFERENCE TO SECTION IV
1.05 GLOSSARY OF TERMS
40 2. TYPES OF BOILERS
2.01 CLASSIFICATION
2.02 STEEL BOILERS
2.03 CAST IRON BOILERS
2.04 MODULAR BOILERS
2.05 VACUUM BOILERS
41 FIGURES
FIG. 2.02A-1 HORIZONTAL RETURN TUBE, BRICK-SET
FIG. 2.02A-2 GAS FLOW PATTERNS OF SCOTCH-TYPE BOILERS
42 FIG. 2.02A-3 TYPE C FIREBOX BOILER
FIG. 2.02A-4 THREE-PASS FIREBOX BOILER
43 FIG. 2.02A-5 LOCOMOTIVE FIREBOX BOILER
FIG. 2.02A-6 VERTICAL FIRETUBE BOILER
44 FIG. 2.03A HORIZONTALSECTIONAL CAST IRON BOILER
FIG. 2.03B VERTICALSECTIONAL CAST IRON BOILER
FIG. 2.04A MODULES CONNECTED WITH PARALLEL PIPING
FIG. 2.04B MODULES CONNECTED WITH PRIMARY-SECONDARY PIPING
45 3. ACCESSORIES AND INSTALLATION
3.01 SAFETY AND SAFETY RELIEF VALVES
3.02 LOW- WATER FUEL CUTOFFS AND WATER FEEDERS
3.03 TRAPS
3.04 AIR ELIMINATORS
FIGURES
FIG. 3.01 OFFICIAL SYMBOL
46 3.05 CONDENSATE RETURN PUMPS AND RETURN LOOP
3.06 VACUUM RETURN PUMP
3.07 CIRCULATORS ( CIRCULATING PUMPS)
3.08 EXPANSION TANK
FIG. 3.01A SAFETY VALVE
47 FIG. 3.01B SAFETY RELIEF VALVE
FIG. 3.02A FLOAT TYPE LOW-WATER CUTOFF
48 FIG. 3.02B ELECTRIC PROBE TYPE LOW-WATER CONTROL
49 3.09 OIL PREHEATERS
3.10 FUEL OIL STORAGE AND SUPPLY SYSTEMS
3.11 PRESSURE GAGE
FIG. 3.03-1 THERMOSTATIC TRAP
FIG. 3.03-4 BUCKET TRAP WITH TRAP CLOSED
FIG. 3.03-2 FLOAT TRAP
FIG. 3.03-3 FLOAT AND THERMOSTATIC TRAP
50 3.20 PRESSURE RELIEVING VALVE REQUIREMENTS
FIG. 3.05 TYPICAL RETURN LOOP
51 FIG. 3.11 PRESSURE GAGES
52 TABLES
TABLE 3.20MINIMUM POUNDS OF STEAM PER HOUR PERSQUARE FOOT OF HEATING SURFACE (kg/h/m2)
54 FIG. 3.20I SAFETY RELIEF VALVE DISCHARGE PIPE
55 3.21 STEAM GAGES
3.22 WATER GAGE GLASSES
3.23 WATER COLUMN AND WATER LEVEL CONTROL PIPES
56 3.24 PRESSURE CONTROL
3.25 PRESSURE OR ALTITUDE GAGES
3.26 THERMOMETERS
3.27 TEMPERATURE CONTROL
3.28 AUTOMATIC LOW- WATER FUEL CUTOFF AND/ OR WATER FEEDING DEVICE ( STEAM)
57 3.29 LOW- WATER FUEL CUTOFF ( HOT WATER)
3.30 PIPING
58 3.31 PROVISIONS FOR THERMAL EXPANSION IN HOT WATER SYSTEMS
3.32 STOP VALVES
B. For Single Hot Water Heating Boilers
C. For Multiple Boiler Installations.
D. Type of Stop Valve( s)
E. Identification of Stop Valves by Tags.
59 FIG. 3.30-1 SINGLE HOT WATER HEATING BOILER ā€” ACCEPTABLE PIPING INSTALLATION
60 FIG. 3.30-2 HOT WATER HEATING BOILERS IN BATTERY ā€” ACCEPTABLE PIPING INSTALLATION
61 FIG. 3.30-3 SINGLE STEAM BOILERS ā€” ACCEPTABLE PIPING INSTALLATION
62 FIG. 3.30-4A STEAM BOILERS IN BATTERY ā€” PUMPED RETURN ā€” ACCEPTABLE PIPING INSTALLATION
63 FIG. 3.30-4B STEAM BOILERS IN BATTERY ā€” GRAVITY RETURN ā€” ACCEPTABLE PIPING INSTALLATION
64 3.33 BOTTOM BLOWOFF AND DRAIN VALVES
3.34 OIL HEATERS
3.35 SHUTDOWN SWITCHES AND CIRCUIT BREAKERS
TABLE 3.31C-1EXPANSION TANK CAPACITIES FOR GRAVITYHOT WATER SYSTEMS
TABLE 3.31C-2EXPANSION TANK CAPACITIES FOR FORCEDHOT WATER SYSTEMS
TABLE 3.33SIZE OF BOTTOM BLOWOFF PIPING,VALVES, AND COCKS
65 3.36 MODULAR BOILERS
3.37 VACUUM BOILERS
3.38 STORAGE TANKS FOR HOT WATER SUPPLY SYSTEMS
66 4. FUELS
4.01 GAS ā€” NATURAL, MANUFACTURED, MIXED
4.02 LIQUEFIED PETROLEUM GAS ( LPG)
4.03 FUEL OILS
67 4.04 COAL
4.05 ELECTRICITY
68 5. FUEL BURNING EQUIPMENT AND FUEL BURNING CONTROLS
5.01 GAS BURNING EQUIPMENT
5.02 OIL BURNING EQUIPMENT
FIGURES
FIG. 5.01A ATMOSPHERIC GAS BURNER
69 FIG. 5.01C COMBINATION FUEL BURNERS
FIG. 5.02A HIGH-PRESSURE ATOMIZING BURNER
70 5.03 COAL BURNING EQUIPMENT
5.04 CONTROLS
FIG. 5.02D HORIZONTAL ROTARY CUP FUEL OIL BURNER
71 FIG. 5.03-1 UNDERFEED SINGLE-RETORT STOKER
FIG. 5.03-2 OVERTHROW RECIPROCATING PLATE-FEED TYPE SPREADER STOKER
72 FIG. 5.03-3 CHAIN GRATE STOKER WITH SECTION SHOWING LINKS
74 6. BOILER ROOM FACILITIES
6.01 GENERAL
6.02 SAFETY
6.03 LIGHTING
6.04 VENTILATION
6.05 WATER AND DRAIN CONNECTIONS
6.06 FIRE PROTECTION
6.07 HOUSEKEEPING
75 6.08 POSTING OF CERTIFICATES AND/ OR LICENSES
6.09 RECORDKEEPING, LOGS, ETC.
76 7. OPERATION, MAINTENANCE, AND REPAIR ā€” STEAM BOILERS
7.01 STARTING A NEW BOILER AND HEATING SYSTEM
77 7.02 STARTING A BOILER AFTER LAYUP ( SINGLE BOILER INSTALLATION)
7.03 CONDENSATION
7.04 CUTTING IN AN ADDITIONAL BOILER
7.05 OPERATION
79 7.06 REMOVAL OF BOILER FROM SERVICE
7.07 MAINTENANCE
81 7.08 BOILER REPAIRS
7.09 TESTS AND INSPECTIONS OF STEAM HEATING BOILERS
85 8. OPERATION, MAINTENANCE, AND REPAIR ā€” HOT WATER BOILERS AND HOT WATER HEATING BOILERS
8.01 STARTING A NEW BOILER AND HEATING SYSTEM
8.02 STARTING A BOILER AFTER LAYUP ( SINGLE BOILER INSTALLATION) A. Procedure.
86 8.03 CONDENSATION
8.04 CUTTING IN AN ADDITIONAL BOILER
8.05 OPERATION A. Check of Pressure and Temperature.
87 8.06 REMOVAL OF BOILER FROM SERVICE
8.07 MAINTENANCE
89 8.08 BOILER REPAIRS
90 8.09 TESTS AND INSPECTIONS OF HOT WATER HEATING AND SUPPLY BOILERS
93 9. WATER TREATMENT
9.01 SCOPE
9.02 CONSIDERATIONS
9.03 SERVICES OF WATER TREATMENT SPECIALISTS
9.04 CONFORMITY WITH LOCAL ORDINANCES
9.05 BOILER WATER TROUBLES
9.06 CHEMICALS USED
94 9.07 FUNCTIONS OF CHEMICALS
9.08 TREATMENT ALTERNATIVES
9.09 BLOWDOWN
95 9.10 FEEDERS
9.11 PROCEDURES
9.12 GLOSSARY OF WATER TREATMENT TERMS
97 MANDATORY APPENDIX I EXHIBITS
108 MANDATORY APPENDIX II SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE
110 MANDATORY APPENDIX III STANDARD UNITS FOR USE IN EQUATIONS
111 NONMANDATORY APPENDIX A GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE
114 INDEX
ASME BPVC VI 2010