ASME BPVC VII 2013
$377.00
ASME BPVC – VII -2013 BPVC Section VII, Recommended Guidelines for the Care of Power Boilers
Published By | Publication Date | Number of Pages |
ASME | 2013 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
36 | C1.2-1 Simple Steam Drum C1.2-2 Steam Drum With Tubes |
37 | C1.2-3a Steam Drum Internals — Baffle Type C1.2-3b Steam Drum Internals — Double‐Row Arrangement, Cyclone Separator Type |
52 | C3.2-1 Typical Pilot and Gas Piping Arrangement |
54 | C3.2-2 Typical Fuel Oil Train |
56 | C3.2-3 Typical Underfeed Stoker C3.2-4 Feeder–Distributor for Firing of Coal on a Spreader Stoker |
58 | C3.2-5 Spreader Stoker, Continuous Ash Discharge Grate |
59 | C3.2-6 Typical Bowl Mill |
62 | C3.2-7 Typical Impact Mill |
63 | C3.2-8 Arrangement of Ball‐Tube Mill C3.2-9 Burner for Horizontal Firing of Coal |
65 | C3.3-1 Typical Tubular Air Heater |
66 | C3.3-2 Typical Regenerative Air Heater |
67 | C3.3-3 Details of Regenerative Air Preheater, Bisector Type |
68 | C3.4-1 Typical Economizer |
70 | C3.5-1 Typical Centrifugal Boiler Feed Pump, Water Connections |
71 | C3.6-1 Typical Motor Drive |
72 | C3.6-2 Typical Single Stage Turbine Drive |
73 | C3.6-3 Typical Turbine Drive Arrangement |
74 | C3.7-1 Airfoil Blade Centrifugal Fan With Inlet Vane Control |
75 | C3.8-1 Typical Outlet Fan Dampers |
77 | C4.1-1 Safety Valve Nameplate |
78 | C4.1-2 Typical Safety Valve |
79 | C4.1-3 Recommended Safety Valve Installation |
81 | C4.1-4 Application of Test Gag |
82 | C4.1-5 Hydraulic Lift Assist Device |
84 | C4.2-1 Test Apparatus for Seat Tightness C4.2-1 Leakage Rates for Safety Relief Valves for Set Procedures to 1,000 psig (7 MPa) |
91 | C6.1-1 Typical Boiler Water Level Gage Installation |
93 | C6.3-1 Typical Valve Lineup Prior to Inspection |
95 | C6.4-1 Typical Stays |
96 | C6.4-2 Typical Forms of Fusible Plugs |
111 | C8.4-1 Scale Causing Overheating and Tube Failure C8.4-2 Deposit Effect on Boiler Tube Versus Tube Temperature |
113 | C8.5-1 Oxygen Corrosion in an Economizer Tube |
114 | C8.5-2 Caustic Gouge‐Type Attack on Boiler Tube |
115 | C8.5-3 Chelate Attack Caused by Excessive Feed of Chemical |
116 | C8.5-4 CO2 Carbonic Acid Attack on Condensate Pipe |
117 | C8.5-5 Oxygen Attack on Condensate Pipe C8.6-1 H+ Damage on Boiler Tube |
119 | C8.8-1 Methods for Sampling of Water and Steam C8.8-2 Methods of Analysis for the Control of Water for Boilers |
120 | C8.8-3 Useful Tests for the Control of Water for Boilers |
131 | II-1 Standard Units for Use in Equations |