ASME BPVC XI 2010
$377.00
ASME BPVC – XI -2010 BPVC Section XI-Rules for Inservice Inspection of Nuclear Power Plant Components
Published By | Publication Date | Number of Pages |
ASME | 2010 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
16 | LIST OF SECTIONS |
18 | FOREWORD |
20 | STATEMENT OF POLICY |
21 | PERSONNEL |
33 | PREFACE TO SECTION XI |
34 | ORGANIZATION OF SECTION XI |
37 | SUMMARY OF CHANGES |
41 | LIST OF CHANGES IN BC ORDER |
42 | DIVISION 1 RULES FOR INSPECTION AND TESTING OF COMPONENTS OF LIGHT- WATER- COOLED PLANTS SUBSECTION IWA GENERAL REQUIREMENTS ARTICLE IWA-1000 SCOPE AND RESPONSIBILITY IWA- 1100 SCOPE IWA- 1200 JURISDICTION IWA- 1300 APPLICATION IWA- 1310 COMPONENTS SUBJECT TO INSPECTION AND TESTING |
43 | IWA- 1320 CLASSIFICATIONS IWA- 1400 OWNER’S RESPONSIBILITY |
44 | IWA- 1500 ACCESSIBILITY IWA- 1600 REFERENCED STANDARDS AND SPECIFICATIONS IWA- 1700 STANDARD UNITS TABLE IWA-1600-1 REFERENCED STANDARDS AND SPECIFICATIONS |
46 | ARTICLE IWA- 2000 EXAMINATION AND INSPECTION IWA- 2100 GENERAL IWA- 2110 DUTIES OF THE INSPECTOR IWA- 2120 QUALIFICATION OF AUTHORIZED INSPECTION AGENCIES, INSPECTORS, AND SUPERVISORS IWA- 2130 ACCESS FOR INSPECTOR |
47 | IWA- 2200 EXAMINATION METHODS IWA- 2210 VISUAL EXAMINATION TABLE IWA-2211-1 VISUAL EXAMINATIONS |
48 | IWA- 2220 SURFACE EXAMINATION IWA- 2230 VOLUMETRIC EXAMINATION |
49 | IWA- 2240 ALTERNATIVE EXAMINATIONS IWA- 2300 QUALIFICATIONS OF NONDESTRUCTIVE EXAMINATION PERSONNEL IWA- 2310 GENERAL |
51 | IWA- 2320 QUALIFICATION EXAMINATIONS IWA- 2321 Vision Tests |
52 | IWA- 2330 LEVEL I RESPONSIBILITIES IWA- 2340 LEVEL III EDUCATION IWA- 2350 LIMITED CERTIFICATION IWA- 2360 LEVEL I AND LEVEL II TRAINING AND EXPERIENCE IWA- 2370 LEVEL III EXPERIENCE IWA- 2380 NDE INSTRUCTOR IWA- 2400 INSPECTION PROGRAM IWA- 2410 APPLICATION OF CODE EDITION AND ADDENDA IWA- 2420 INSPECTION PLANS AND SCHEDULES |
53 | IWA- 2430 INSPECTION INTERVALS IWA- 2440 APPLICATION OF CODE CASES IWA- 2441 Section XI Code Cases |
54 | IWA- 2500 EXTENT OF EXAMINATION IWA- 2600 WELD REFERENCE SYSTEM IWA- 2610 GENERAL IWA- 2620 PIPING IWA- 2630 VESSELS IWA- 2640 OTHER COMPONENTS |
55 | ARTICLE IWA- 3000 STANDARDS FOR EXAMINATION EVALUATION IWA- 3100 EVALUATION IWA- 3200 SIGNIFICANT DIGITS FOR LIMITING VALUES IWA- 3300 FLAW CHARACTERIZATION IWA- 3310 SURFACE PLANAR FLAWS |
56 | IWA- 3320 SUBSURFACE PLANAR FLAWS IWA- 3330 MULTIPLE PLANAR FLAWS IWA- 3340 NONPLANAR FLAWS IWA- 3350 PARALLEL PLANAR FLAWS IWA- 3360 LAMINAR FLAWS IWA- 3370 RADIOGRAPHIC EXAMINATION IWA- 3380 MULTIPLE NONALIGNED COPLANAR FLAWS |
57 | IWA- 3390 MULTIPLE ALIGNED SEPARATE FLAWS IWA- 3400 LINEAR FLAWS DETECTED BY SURFACE OR VOLUMETRIC EXAMINATIONS |
58 | FIGURES FIG. IWA-3310-1 SURFACE PLANAR FLAWS ORIENTED IN PLANE NORMAL TOPRESSURE RETAINING SURFACE |
59 | FIG. IWA-3320-1 SUBSURFACE PLANAR FLAWS ORIENTED IN PLANE NORMAL TOPRESSURE RETAINING SURFACE |
61 | FIG. IWA-3340-1 NONPLANAR ELLIPTICAL SUBSURFACE FLAWS |
62 | FIG. IWA-3350-1 PARALLEL PLANAR FLAWS |
63 | FIG. IWA-3360-1 LAMINAR FLAWS |
65 | FIG. IWA-3390-1 MULTIPLE ALIGNED PLANAR FLAWS |
66 | FIG. IWA-3400-1 LINEAR SURFACE FLAWS |
67 | ARTICLE IWA- 4000 REPAIR/ REPLACEMENT ACTIVITIES IWA- 4100 GENERAL REQUIREMENTS IWA- 4110 SCOPE IWA- 4120 APPLICABILITY |
68 | IWA- 4130 ALTERNATIVE REQUIREMENTS |
69 | IWA- 4140 RESPONSIBILITIES |
70 | IWA- 4150 REPAIR/ REPLACEMENT PROGRAM AND PLAN IWA- 4160 VERIFICATION OF ACCEPTABILITY IWA- 4170 INSPECTION |
71 | IWA- 4180 DOCUMENTATION IWA- 4190 APPLICATION OF SECTION XI CODE CASES IWA- 4200 ITEMS FOR REPAIR/ REPLACEMENT ACTIVITIES IWA- 4210 GENERAL REQUIREMENTS IWA- 4220 CODE APPLICABILITY |
73 | IWA- 4230 Helical- Coil Threaded Inserts, Classes 1, 2, and 3 IWA- 4300 DESIGN IWA- 4310 GENERAL REQUIREMENTS IWA- 4320 PIPING |
74 | IWA- 4330 RERATING IWA- 4340 MITIGATION OF DEFECTS BY MODIFICATION IWA- 4400 WELDING, BRAZING, METAL REMOVAL, FABRICATION, AND INSTALLATION IWA- 4410 GENERAL REQUIREMENTS |
75 | IWA- 4420 DEFECT REMOVAL REQUIREMENTS |
76 | IWA- 4440 WELDING AND WELDER QUALIFICATION ( INCLUDING WELDING OPERATORS) IWA- 4460 METAL REMOVAL PROCESSES IWA- 4461 Thermal Removal Processes |
77 | IWA- 4500 EXAMINATION AND TESTING IWA- 4510 GENERAL REQUIREMENTS IWA- 4520 EXAMINATION TABLES TABLE IWA-4461.1-1 MINIMUM PREHEAT TEMPERATURE, °F (°C) |
78 | IWA- 4530 PRESERVICE INSPECTION IWA- 4540 PRESSURE TESTING OF CLASSES 1, 2, AND 3 ITEMS |
79 | IWA- 4550 CLASS MC AND METALLIC PORTIONS OF CLASS CC CONTAINMENTS IWA- 4600 ALTERNATIVE WELDING METHODS IWA- 4610 GENERAL REQUIREMENTS FOR TEMPER BEAD WELDING |
80 | IWA- 4620 TEMPER BEAD WELDING OF SIMILAR MATERIALS IWA- 4621 General Requirements |
81 | FIGURES FIG. IWA-4622-1 QUALIFICATION TEST PLATE |
82 | FIG. IWA-4623.1-1 TEMPER BEAD WELDING AND WELD TEMPER BEAD REINFORCEMENT |
83 | IWA- 4630 TEMPER BEAD WELDING OF DISSIMILAR MATERIALS |
85 | IWA- 4640 CLADDING |
86 | FIG. IWA-4633.1-1 TEMPER BEAD WELDING AND WELD TEMPER BEAD REINFORCEMENT OF DISSIMILARMETAL WELDS OR BUTTERING |
87 | FIG. IWA-4633.2-1 AUTOMATIC OR MACHINE (GTAW) TEMPER BEAD WELDING OFDISSIMILAR METAL WELDS OR BUTTERING |
88 | IWA- 4650 BUTTER BEAD — TEMPER BEAD WELDING FOR CLASS MC AND FOR CLASS CC METALLIC LINERS |
91 | IWA- 4660 UNDERWATER WELDING |
93 | FIG. IWA-4652.4-2 ILLUSTRATION OF THE TEMPER BEAD TECHNIQUE FOR REINFORCEMENT OF EXISTINGFILLET WELDS |
94 | FIG. IWA-4655-1 WELDING TECHNIQUES FOR IMPROPER TEMPER BEAD SPACING |
95 | FIG. IWA-4655-2 EXAMPLE OF WELD UNDERCUT WELDING TECHNIQUE |
97 | TABLE IWA-4662.1-1DEPTH LIMITATIONS FOR UNDERWATER WELDINGQUALIFICATION |
98 | TABLE IWA-4662.1-2PROCEDURE AND PERFORMANCE QUALIFICATION — POSITION LIMITATIONS |
99 | IWA- 4700 HEAT EXCHANGER TUBING IWA- 4710 PLUGGING |
102 | FIG. IWA-4712.2-1 EXAMPLES OF EXTENSION AND RECESS OF TUBE AND PLUG |
104 | IWA- 4720 SLEEVING |
108 | ARTICLE IWA- 5000 SYSTEM PRESSURE TESTS IWA- 5100 GENERAL IWA- 5110 PERIODIC SYSTEM PRESSURE TESTS IWA- 5200 SYSTEM TEST REQUIREMENT IWA- 5210 TEST IWA- 5211 Test Description IWA- 5212 Pressure and Temperature IWA- 5213 Test Condition Holding Time |
109 | IWA- 5214 Preservice Test IWA- 5220 TEST PRESSURIZATION BOUNDARIES1 IWA- 5221 System Leakage Test Boundary IWA- 5222 System Hydrostatic Test Boundary IWA- 5240 VISUAL EXAMINATION IWA- 5241 Insulated and Noninsulated Components |
110 | IWA- 5244 Buried Components IWA- 5245 Elevated Temperature Tests IWA- 5250 CORRECTIVE ACTION IWA- 5251 Alternative Corrective Action for Leakage Identified at Bolted Connections |
111 | IWA- 5260 INSTRUMENTS FOR SYSTEM HYDROSTATIC TESTS IWA- 5261 Type IWA- 5262 Accuracy IWA- 5263 Calibration IWA- 5264 Ranges IWA- 5265 Location IWA- 5300 TEST RECORDS |
112 | ARTICLE IWA- 6000 RECORDS AND REPORTS IWA- 6100 SCOPE IWA- 6200 REQUIREMENTS IWA- 6210 RESPONSIBILITIES IWA- 6220 PREPARATION OF ABSTRACT OF EXAMINATION REQUIRED BY FORM NIS- 1 IWA- 6230 SUMMARY REPORT PREPARATION |
113 | IWA- 6240 SUMMARY REPORTS IWA- 6300 RETENTION IWA- 6310 MAINTENANCE OF RECORDS IWA- 6320 REPRODUCTION, DIGITIZATION, AND MICROFILMING IWA- 6330 CONSTRUCTION RECORDS IWA- 6340 INSERVICE INSPECTION RECORDS IWA- 6350 REPAIR/ REPLACEMENT ACTIVITY RECORDS |
114 | ARTICLE IWA- 9000 GLOSSARY |
119 | SUBSECTION IWB REQUIREMENTS FOR CLASS 1 COMPONENTS OF LIGHT- WATER COOLED PLANTS ARTICLE IWB-1000 SCOPE AND RESPONSIBILITY IWB- 1100 SCOPE IWB- 1200 COMPONENTS SUBJECT TO EXAMINATION IWB- 1210 EXAMINATION REQUIREMENTS IWB- 1220 COMPONENTS EXEMPT FROM EXAMINATION |
120 | ARTICLE IWB- 2000 EXAMINATION AND INSPECTION IWB- 2200 PRESERVICE EXAMINATION IWB- 2400 INSPECTION SCHEDULE IWB- 2410 INSPECTION PROGRAM |
121 | IWB- 2420 SUCCESSIVE INSPECTIONS IWB- 2430 ADDITIONAL EXAMINATIONS TABLES TABLE IWB-2411-1 INSPECTION PROGRA |
122 | IWB- 2500 EXAMINATION AND PRESSURE TEST REQUIREMENTS |
123 | TABLE IWB-2500-1 EXAMINATION CATEGORIES |
142 | FIG. IWB-2500-4 SHELL-TO-FLANGE WELD JOINT |
143 | FIG. IWB-2500-5 HEAD-TO-FLANGE WELD JOINT |
144 | FIG. IWB-2500-6 TYPICAL TUBESHEET-TO-HEAD WELD JOINTS |
145 | FIG. IWB-2500-7(a) NOZZLE IN SHELL OR HEAD |
146 | FIG. IWB-2500-7(b) NOZZLE IN SHELL OR HEAD |
147 | FIG. IWB-2500-7(c) NOZZLE IN SHELL OR HEAD |
148 | FIG. IWB-2500-7(d) NOZZLE IN SHELL OR HEAD |
149 | FIG. IWB-2500-8 SIMILAR AND DISSIMILAR METAL WELDS IN COMPONENTS, NOZZLES, AND PIPING |
151 | FIG. IWB-2500-9 PIPE BRANCH CONNECTION |
152 | FIG. IWB-2500-10 PIPE BRANCH CONNECTION |
153 | FIG. IWB-2500-11 PIPE BRANCH CONNECTION |
154 | FIG. IWB-2500-12 CLOSURE STUD AND THREADS IN FLANGE STUD HOLE |
155 | FIG. IWB-2500-13 WELDED ATTACHMENT |
156 | FIG. IWB-2500-14 WELDED ATTACHMENT |
157 | FIG. IWB-2500-15 WELDED ATTACHMENT |
158 | FIG. IWB-2500-18 CONTROL ROD DRIVE AND INSTRUMENT NOZZLE HOUSING WELDS |
159 | FIG. IWB-2500-20 EXTENT OF WELD EXAMINATION |
160 | ARTICLE IWB- 3000 ACCEPTANCE STANDARDS IWB- 3100 EVALUATION OF EXAMINATION RESULTS IWB- 3110 PRESERVICE VOLUMETRIC AND SURFACE EXAMINATIONS IWB- 3120 PRESERVICE VISUAL EXAMINATIONS |
161 | IWB- 3130 INSERVICE VOLUMETRIC AND SURFACE EXAMINATIONS IWB- 3140 INSERVICE VISUAL EXAMINATIONS |
162 | IWB- 3200 SUPPLEMENTAL EXAMINATIONS IWB- 3400 STANDARDS IWB- 3410 ACCEPTANCE STANDARDS |
163 | IWB- 3420 CHARACTERIZATION IWB- 3430 ACCEPTABILITY IWB- 3500 ACCEPTANCE STANDARDS IWB- 3510 STANDARDS FOR EXAMINATION CATEGORY B- A, PRESSURE RETAINING WELDS IN REACTOR VESSEL, AND EXAMINATION CATEGORY B- B, PRESSURE RETAINING WELDS IN VESSELS OTHER THAN REACTOR VESSELS IWB- 3510.1 Allowable Planar Flaws TABLES TABLE IWB-3410-1 ACCEPTANCE STANDARDS |
164 | TABLE IWB-3510-1ALLOWABLE PLANAR FLAWS TABLE IWB-3510-2ALLOWABLE LAMINAR FLAWS |
165 | TABLE IWB-3510-3ALLOWABLE LINEAR FLAWS1 TABLE IWB-3512-1ALLOWABLE PLANAR FLAWS |
166 | TABLE IWB-3512-2COMPONENT THICKNESS VS FLAW LOCATION |
167 | TABLE IWB-3514-1ALLOWABLE PLANAR FLAWS |
168 | TABLE IWB-3514-2ALLOWABLE LINEAR FLAWS TABLE IWB-3514-3ALLOWABLE LAMINAR FLAWS |
169 | TABLE IWB-3514-4ALLOWABLE LINEAR FLAWS |
170 | TABLE IWB-3515-1ALLOWABLE PLANAR FLAWS |
171 | TABLE IWB-3518-1ALLOWABLE PLANAR FLAWS |
172 | IWB- 3520 STANDARDS FOR EXAMINATION CATEGORY B- N- 1, INTERIOR OF REACTOR VESSEL, EXAMINATION CATEGORY B- N- 2, WELDED CORE SUPPORT STRUCTURES AND INTERIOR ATTACHMENTS TO REACTOR VESSELS, AND EXAMINATION CATEGORY B- N- 3, REMOVABLE CORE SUPPORT STRUCTURES IWB- 3520.1 Visual Examination, VT- 1. TABLE IWB-3518-2ALLOWABLE PLANAR FLAWS |
173 | IWB- 3600 ANALYTICAL EVALUATION OF PLANAR FLAWS IWB- 3610 ACCEPTANCE CRITERIA FOR FERRITIC STEEL COMPONENTS 4 in. ( 100 mm) AND GREATER IN THICKNESS |
174 | FIGURES FIG. IWB-3610-1 CHARACTERIZATION AND PROXIMITY RULES FOR ANALYTICALEVALUATION OF CLAD COMPONENTS |
176 | IWB- 3620 ACCEPTANCE CRITERIA FOR FERRITIC COMPONENTS LESS THAN 4 in. ( 100 mm) IN THICKNESS IWB- 3630 ACCEPTANCE CRITERIA FOR STEAM GENERATOR TUBING IWB- 3640 EVALUATION PROCEDURES AND ACCEPTANCE CRITERIA FOR FLAWS IN AUSTENITIC AND FERRITIC PIPING |
178 | IWB- 3730 FRACTURE TOUGHNESS CRITERIA FOR PROTECTION AGAINST FAILURE IWB- 3740 OPERATING PLANT FATIGUE ASSESSMENTS TABLE IWB-3663-1REACTOR VESSEL HEADPENETRATION NOZZLE ACCEPTANCE CRITERIA |
179 | ARTICLE IWB- 5000 SYSTEM PRESSURE TESTS IWB- 5200 SYSTEM TEST REQUIREMENTS IWB- 5210 TEST IWB- 5220 SYSTEM LEAKAGE TEST IWB- 5230 HYDROSTATIC TEST IWB- 5240 TEMPERATURE |
180 | SUBSECTION IWC REQUIREMENTS FOR CLASS 2 COMPONENTS OFLIGHT-WATER COOLED PLANTS ARTICLE IWC- 1000 SCOPE AND RESPONSIBILITY IWC- 1100 SCOPE IWC- 1200 COMPONENTS SUBJECT TO EXAMINATION IWC- 1210 EXAMINATION REQUIREMENTS IWC- 1220 COMPONENTS EXEMPT FROM EXAMINATION IWC- 1221 Components Within RHR, ECC, and CHR Systems or Portions of Systems1 |
181 | IWC- 1222 Components Within Systems or Portions of Systems Other Than RHR, ECC, and CHR Systems1 IWC- 1223 Inaccessible Welds |
182 | ARTICLE IWC- 2000 EXAMINATION AND INSPECTION IWC- 2200 PRESERVICE EXAMINATION IWC- 2400 INSPECTION SCHEDULE IWC- 2410 INSPECTION PROGRAM IWC- 2420 SUCCESSIVE INSPECTIONS TABLES TABLE IWC-2411-1 INSPECTION PROGRAM |
183 | IWC- 2430 ADDITIONAL EXAMINATIONS |
184 | IWC- 2500 EXAMINATION AND PRESSURE TEST REQUIREMENTS |
185 | TABLE IWC-2500-1 EXAMINATION CATEGORIES |
194 | FIGURES FIG. IWC-2500-1 VESSEL CIRCUMFERENTIAL WELDS |
195 | FIG. IWC-2500-2 TYPICAL TUBESHEET-TO-SHELL CIRCUMFERENTIAL WELDS |
196 | FIG. IWC-2500-3 NOZZLE-TO-VESSEL WELDS |
197 | FIG. IWC-2500-4 NOZZLE-TO-VESSEL WELDS |
200 | FIG. IWC-2500-5 WELDED ATTACHMENTS |
201 | FIG. |
202 | FIG. IWC-2500-7 WELDS IN PIPING |
203 | FIG. IWC-2500-9 BRANCH CONNECTION WELDS |
204 | FIG. IWC-2500-10 PIPE BRANCH CONNECTION |
205 | FIG. IWC-2500-11 PIPE BRANCH CONNECTION |
206 | FIG. IWC-2500-12 PIPE BRANCH CONNECTION |
207 | FIG. IWC-2500-13 PIPE BRANCH CONNECTION |
208 | ARTICLE IWC- 3000 ACCEPTANCE STANDARDS IWC- 3100 EVALUATION OF EXAMINATION RESULTS IWC- 3110 PRESERVICE VOLUMETRIC AND SURFACE EXAMINATIONS IWC- 3111 General IWC- 3112 Acceptance IWC- 3113 Repair/ Replacement Activity and Reexamination IWC- 3114 Review by Authorities IWC- 3120 INSERVICE VOLUMETRIC AND SURFACE EXAMINATIONS IWC- 3121 General IWC- 3122 Acceptance IWC- 3122.1 Acceptance by Examination. IWC- 3122.2 Acceptance by Repair / Replacement Activity. |
209 | IWC- 3122.3 Acceptance by Analytical Evaluation. IWC- 3124 Repair/ Replacement Activity and Reexamination IWC- 3125 Review by Authorities IWC- 3130 INSERVICE VISUAL EXAMINATIONS IWC- 3131 General IWC- 3132 Acceptance IWC- 3132.1 Acceptance by Supplemental Examina-tion. IWC- 3132.2 Acceptance by Corrective Measures or Repair/ Replacement Activity. IWC- 3132.3 Acceptance by Analytical Evaluation. IWC- 3133 Repair/ Replacement Activity and Reexamination IWC- 3134 Review by Authorities IWC- 3200 SUPPLEMENTAL EXAMINATIONS IWC- 3400 STANDARDS IWC- 3410 ACCEPTANCE STANDARDS |
210 | IWC- 3410.1 Applications of Standards. IWC- 3420 CHARACTERIZATION IWC- 3430 ACCEPTABILITY IWC- 3500 ACCEPTANCE STANDARDS IWC- 3510 STANDARDS FOR EXAMINATION CATEGORY C- A, PRESSURE RETAINING WELDS IN PRESSURE VESSELS IWC- 3510.1 Allowable Planar Flaws IWC- 3510.2 Allowable Laminar Flaws. IWC- 3510.3 Conditionally Allowable Laminar Flaws IWC- 3510.4 Allowable Linear Flaws IWC- 3511 Standards for Examination Category C- B, Pressure Retaining Welds of Nozzles in Vessels IWC- 3511.1 Allowable Planar Flaws |
211 | TABLE IWC-3510-1ALLOWABLE PLANAR FLAWS TABLE IWC-3510-2ALLOWABLE LAMINAR FLAWS TABLE IWC-3510-3ALLOWABLE LINEAR FLAWS |
212 | IWC- 3511.2 Allowable Linear Flaws IWC- 3511.3 Allowable Laminar Flaws IWC- 3512 Standards for Examination Category C- C, Welded Attachments for Vessels, Piping, Pumps, and Valves IWC- 3512.1 Allowable Linear Flaws IWC- 3513 Standards for Examination Category C- D, Pressure Retaining Bolting Greater Than 2 in. ( 50 mm) in Diameter IWC- 3513.1 Allowable Flaws for Volumetric Exami-nations of Studs and Bolts IWC- 3513.2 Allowable Flaws for Surface Examina-tions of Studs and Bolts. IWC- 3514 Standards for Examination Category C- F- 1, Pressure Retaining Welds in Austenitic Stainless Steel or High Alloy Piping, and C- F- 2, Pressure Retaining Welds in Carbon or Low Alloy Steel Piping |
213 | TABLE IWC-3511-1ALLOWABLE PLANAR FLAWS TABLE IWC-3511-2ALLOWABLE LINEAR FLAWS1 TABLE IWC-3513-1ALLOWABLE PLANAR FLAWS |
214 | IWC- 3514.1 Allowable Planar Flaws IWC- 3514.2 Allowable Flaw Standards for Ferritic Piping. IWC- 3514.3 Allowable Flaw Standards for Austen-itic or High Alloy Piping IWC- 3514.4 Allowable Laminar Flaws for Austen-itic Piping. IWC- 3514.5 Allowable Linear Flaw Standards for Austenitic or High Alloy Piping IWC- 3514.6 Surface- Connected Flaws in Contact With the Reactor Coolant Environment That Are Detected by Preservice Examination in Materials Sus-ceptible to Stress Corrosion Cracking. IWC- 3516 Standards for Examination Category C- H, All Pressure Retaining Components IWC- 3600 ANALYTICAL EVALUATION OF PLANAR FLAWS IWC- 3610 ACCEPTANCE CRITERIA FOR FERRITIC COMPONENTS |
215 | TABLE IWC-3514-1ALLOWABLE PLANAR FLAWS |
216 | IWC- 3640 EVALUATION PROCEDURES AND ACCEPTANCE CRITERIA FOR FLAWS IN AUSTENITIC AND FERRITIC PIPING IWC- 3641 Evaluation Procedures IWC- 3642 Evaluation Procedures and Acceptance Criteria Based on Failure Mode Determination IWC- 3643 Evaluation Procedure and Acceptance Criteria Based on Use of a Failure Assessment Diagram IWC- 3644 Alternative Evaluation Procedure and Acceptance Criteria Based on Applied Stress |
217 | ARTICLE IWC- 5000 SYSTEM PRESSURE TESTS IWC- 5200 SYSTEM TEST REQUIREMENTS IWC- 5210 TEST IWC- 5220 SYSTEM LEAKAGE TEST IWC- 5221 Pressure IWC- 5222 Boundaries IWC- 5230 HYDROSTATIC TEST |
218 | IWC- 5240 TEMPERATURE |
219 | SUBSECTION IWD REQUIREMENTS FOR CLASS 3 COMPONENTS OF LIGHT-WATER COOLED PLANTS ARTICLE IWD- 1000 SCOPE AND RESPONSIBILITY IWD- 1100 SCOPE IWD- 1200 COMPONENTS SUBJECT TO EXAMINATION IWD- 1210 EXAMINATION REQUIREMENTS IWD- 1220 COMPONENTS EXEMPT FROM EXAMINATION |
220 | ARTICLE IWD- 2000 EXAMINATION AND INSPECTION IWD- 2200 PRESERVICE EXAMINATION IWD- 2400 INSPECTION SCHEDULE IWD- 2410 INSPECTION PROGRAM IWD- 2420 SUCCESSIVE INSPECTIONS TABLES TABLE IWD-2411-1INSPECTION PROGRAM |
221 | IWD- 2430 ADDITIONAL EXAMINATIONS |
222 | IWD- 2500 EXAMINATION AND PRESSURE TEST REQUIREMENTS |
223 | TABLE IWD-2500-1EXAMINATION CATEGORIES |
225 | FIGURE FIG. IWD-2500-1 WELDED ATTACHMENTS |
226 | ARTICLE IWD- 3000 ACCEPTANCE STANDARDS IWD- 3100 EVALUATION OF EXAMINATION RESULTS IWD- 3110 PRESERVICE EXAMINATIONS IWD- 3120 INSERVICE EXAMINATIONS IWD- 3200 SUPPLEMENTAL EXAMINATIONS IWD- 3400 STANDARDS IWD- 3500 ACCEPTANCE STANDARDS IWD- 3600 ANALYTICAL EVALUATION OF PLANAR FLAWS IWD- 3610 ACCEPTANCE CRITERIA FOR FERRITIC COMPONENTS IWD- 3640 EVALUATION PROCEDURES AND ACCEPTANCE CRITERIA FOR FLAWS IN AUSTENITIC AND FERRITIC PIPING |
228 | ARTICLE IWD- 5000 SYSTEM PRESSURE TESTS IWD- 5200 SYSTEM TEST REQUIREMENTS IWD- 5210 TEST IWD- 5220 SYSTEM LEAKAGE TEST IWD- 5221 Pressure IWD- 5222 Boundaries IWD- 5230 HYDROSTATIC TEST |
229 | IWD- 5240 TEMPERATURE |
230 | SUBSECTION IWE REQUIREMENTS FOR CLASS MC AND METALLIC LINERS OF CLASS CC COMPONENTS OF LIGHT-WATER COOLED PLANTS ARTICLE IWE- 1000 SCOPE AND RESPONSIBILITY IWE- 1100 SCOPE IWE- 1200 COMPONENTS SUBJECT TO EXAMINATION IWE- 1210 EXAMINATION REQUIREMENTS IWE- 1220 COMPONENTS EXEMPTED FROM EXAMINATION IWE- 1230 ACCESSIBILITY FOR EXAMINATION |
231 | IWE- 1240 SURFACE AREAS REQUIRING AUGMENTED EXAMINATION |
232 | ARTICLE IWE- 2000 EXAMINATION AND INSPECTION IWE- 2100 GENERAL IWE- 2200 PRESERVICE EXAMINATION IWE- 2300 VISUAL EXAMINATION, PERSONNEL QUALIFICATION, AND RESPONSIBLE INDIVIDUAL IWE- 2310 VISUAL EXAMINATIONS IWE- 2311 General Visual Examinations IWE- 2312 VT- 3 Visual Examinations |
233 | IWE- 2313 VT- 1 Visual Examinations IWE- 2320 RESPONSIBLE INDIVIDUAL IWE- 2330 PERSONNEL QUALIFICATION IWE- 2400 INSPECTION SCHEDULE IWE- 2410 INSPECTION PROGRAM IWE- 2411 Inspection Program IWE- 2420 SUCCESSIVE INSPECTIONS TABLES TABLE IWE-2411-1INSPECTION PROGRAM |
234 | IWE- 2500 EXAMINATION AND PRESSURE TEST REQUIREMENTS IWE- 2600 CONDITION OF SURFACE TO BE EXAMINED |
235 | TABLE IWE-2500-1EXAMINATION CATEGORIES |
238 | FIGURE FIG. IWE-2500-1 EXAMINATION AREAS FOR MOISTURE BARRIERS |
239 | ARTICLE IWE- 3000 ACCEPTANCE STANDARDS IWE- 3100 EVALUATION OF EXAMINATION RESULTS IWE- 3110 PRESERVICE EXAMINATIONS IWE- 3111 General IWE- 3120 INSERVICE EXAMINATIONS IWE- 3121 General |
240 | IWE- 3130 INSERVICE VISUAL EXAMINATIONS IWE- 3200 SUPPLEMENTAL EXAMINATIONS IWE- 3400 STANDARDS IWE- 3410 ACCEPTANCE STANDARDS IWE- 3430 ACCEPTABILITY IWE- 3500 ACCEPTANCE STANDARDS IWE- 3510 STANDARDS FOR EXAMINATION CATEGORY E- A, CONTAINMENT SURFACES IWE- 3511 General Visual Examination of Coated and Noncoated Areas IWE- 3520 STANDARDS FOR EXAMINATION CATEGORY E- C, CONTAINMENT SURFACES REQUIRING AUGMENTED EXAMINATION IWE- 3521 Visual Examination, VT- 1 |
241 | IWE- 3530 STANDARDS2 FOR EXAMINATION CATEGORY E- G, PRESSURE-RETAINING BOLTING IWE- 3531 Visual Examination, VT- 1 |
242 | ARTICLE IWE- 5000 SYSTEM PRESSURE TESTS IWE- 5200 SYSTEM TEST REQUIREMENTS IWE- 5210 GENERAL IWE- 5220 TESTS FOLLOWING REPAIR/ REPLACEMENT ACTIVITIES IWE- 5221 General IWE- 5222 Personnel Qualification IWE- 5223 Pneumatic Leakage Test IWE- 5223.1 Pressure. IWE- 5223.2 Boundaries. IWE- 5223.3 Test Medium and Temperature IWE- 5223.4 Examination. IWE- 5223.5 Leakage. IWE- 5224 Bubble Test- Vacuum Box Technique IWE- 5240 VISUAL EXAMINATION IWE- 5250 CORRECTIVE ACTION |
243 | SUBSECTION IWF REQUIREMENTS FOR CLASS 1, 2, 3, AND MC COMPONENTS SUPPORTS OF LIGHT-WATER COOLED PLANTS ARTICLE IWF- 1000 SCOPE AND RESPONSIBILITY IWF- 1100 SCOPE IWF- 1200 COMPONENT SUPPORTS SUBJECT TO EXAMINATION AND TEST IWF- 1210 EXAMINATION REQUIREMENTS IWF- 1220 SNUBBER INSPECTION REQUIREMENTS1 IWF- 1230 SUPPORTS EXEMPT FROM EXAMINATION IWF- 1300 SUPPORT EXAMINATION BOUNDARIES |
244 | FIGURES FIG. IWF-1300-1 ILLUSTRATIONS OF TYPICAL SUPPORT EXAMINATION BOUNDARIES |
247 | ARTICLE IWF- 2000 EXAMINATION AND INSPECTION IWF- 2100 SCOPE IWF- 2200 PRESERVICE EXAMINATION IWF- 2210 INITIAL EXAMINATION IWF- 2220 ADJUSTMENT AND REPAIR/ REPLACEMENT ACTIVITIES IWF- 2400 INSPECTION SCHEDULE IWF- 2410 INSPECTION PROGRAM IWF- 2420 SUCCESSIVE INSPECTIONS TABLES TABLE IWF-2410-1INSPECTION PROGRAM |
248 | IWF- 2430 ADDITIONAL EXAMINATIONS IWF- 2500 EXAMINATION REQUIREMENTS |
249 | IWF- 2510 SUPPORTS SELECTED FOR EXAMINATION IWF- 2520 METHOD OF EXAMINATION |
250 | TABLE IWF-2500-1EXAMINATION CATEGORIES |
251 | ARTICLE IWF- 3000 STANDARDS FOR EXAMINATION EVALUATIONS IWF- 3100 EVALUATION OF EXAMINATION RESULTS IWF- 3110 PRESERVICE EXAMINATIONS IWF- 3111 General IWF- 3112 Acceptance IWF- 3112.1 Acceptance by Examination. IWF- 3112.2 Acceptance by Corrective Measures or Repair/ Replacement Activity. IWF- 3112.3 Acceptance by Evaluation or Test IWF- 3120 INSERVICE EXAMINATIONS IWF- 3121 General IWF- 3122 Acceptance IWF- 3122.1 Acceptance by Examination. IWF- 3122.2 Acceptance by Corrective Measures or Repair/ Replacement Activity. |
252 | IWF- 3122.3 Acceptance by Evaluation or Test IWF- 3200 SUPPLEMENTAL EXAMINATIONS IWF- 3400 ACCEPTANCE STANDARDS IWF- 3410 ACCEPTANCE STANDARDS — COMPONENT SUPPORT STRUCTURAL INTEGRITY |
253 | SUBSECTION IWL REQUIREMENTS FOR CLASS CC CONCRETE COMPONENTS OF LIGHT-WATER-COOLED PLANTS ARTICLE IWL- 1000 SCOPE AND RESPONSIBILITY IWL- 1100 SCOPE IWL- 1200 ITEMS SUBJECT TO EXAMINATION IWL- 1210 EXAMINATION REQUIREMENTS IWL- 1220 ITEMS EXEMPT FROM EXAMINATION |
254 | ARTICLE IWL- 2000 EXAMINATION AND INSPECTION IWL- 2100 GENERAL IWL- 2200 PRESERVICE EXAMINATION IWL- 2210 EXAMINATION SCHEDULE IWL- 2220 EXAMINATION REQUIREMENTS IWL- 2220.1 Concrete IWL- 2220.2 Unbonded Post- Tensioning Systems. IWL- 2230 PRESERVICE EXAMINATION OF REPAIR/ REPLACEMENT ACTIVITIES IWL- 2300 VISUAL EXAMINATION, PERSONNEL QUALIFICATION, AND RESPONSIBLE ENGINEER IWL- 2310 VISUAL EXAMINATIONS IWL- 2320 PERSONNEL QUALIFICATIONS |
255 | IWL- 2330 RESPONSIBLE ENGINEER IWL- 2400 INSERVICE INSPECTION SCHEDULE IWL- 2410 CONCRETE |
256 | IWL- 2420 UNBONDED POST- TENSIONING SYSTEMS IWL- 2421 Sites With Multiple Plants IWL- 2500 EXAMINATION REQUIREMENTS IWL- 2510 SURFACE EXAMINATION IWL- 2511 Accessible Areas IWL- 2512 Inaccessible Areas |
257 | FIGURES TABLE IWL-2500-1EXAMINATION CATEGORIES |
258 | IWL- 2520 EXAMINATION OF UNBONDED POST- TENSIONING SYSTEMS IWL- 2521 Tendon Selection IWL- 2521.1 Exemptions. IWL- 2521.2 Tendons Affected by Repair/ Replacement Activities |
259 | TABLE IWL-2521-1NUMBER OF TENDONS FOR EXAMINAT TABLE IWL-2521-2AUGMENTED EXAMINATION REQUIREMENTS FOLLOWING POST-TENSIONING SYSTEM REPAIR/REPLACEMENT ACTIVITIES |
260 | IWL- 2522 Tendon Force and Elongation Measurements IWL- 2523 Tendon Wire and Strand Sample Examination and Testing IWL- 2523.1 Tendon Detensioning and Sample Removal. IWL- 2523.2 Sample Examination and Testing IWL- 2523.3 Retensioning IWL- 2524 Examination of Tendon Anchorage Areas IWL- 2524.1 Visual Examination. IWL- 2524.2 Free Water Documentation. IWL- 2525 Examination of Corrosion Protection Medium and Free Water IWL- 2525.1 Samples IWL- 2525.2 Sample Analysis IWL- 2526 Removal and Replacement of Corrosion Protection Medium |
261 | TABLE IWL-2525-1CORROSION PROTECTION MEDIUM ANALYSIS |
262 | ARTICLE IWL- 3000 ACCEPTANCE STANDARDS IWL- 3100 PRESERVICE EXAMINATION IWL- 3110 CONCRETE SURFACE CONDITION IWL- 3111 Acceptance by Examination IWL- 3112 Acceptance by Evaluation IWL- 3113 Acceptance by Repair/ Replacement Activity IWL- 3120 UNBONDED POST- TENSIONING SYSTEM IWL- 3200 INSERVICE EXAMINATION IWL- 3210 SURFACE CONDITION IWL- 3211 Acceptance by Examination IWL- 3212 Acceptance by Evaluation IWL- 3213 Acceptance by Repair/ Replacement Activity IWL- 3220 UNBONDED POST- TENSIONING SYSTEMS IWL- 3221 Acceptance by Examination IWL- 3221.1 Tendon Force and Elongation. IWL- 3221.2 Tendon Wire or Strand Samples. |
263 | IWL- 3221.3 Tendon Anchorage Areas. IWL- 3221.4 Corrosion Protection Medium. IWL- 3222 Acceptance by Evaluation IWL- 3223 Acceptance by Repair/ Replacement Activity IWL- 3300 EVALUATION IWL- 3310 EVALUATION REPORT |
264 | ARTICLE IWL- 4000 REPAIR/ REPLACEMENT ACTIVITIES IWL- 4100 GENERAL IWL- 4110 SCOPE IWL- 4120 REPAIR/ REPLACEMENT PROGRAM IWL- 4180 DOCUMENTATION IWL- 4200 REPAIR/ REPLACEMENT PLAN IWL- 4210 RESPONSIBLE ENGINEER IWL- 4220 CONCRETE |
265 | IWL- 4230 REINFORCING STEEL IWL- 4240 POST- TENSIONING SYSTEM IWL- 4300 EXAMINATION |
266 | ARTICLE IWL- 5000 SYSTEM PRESSURE TESTS IWL- 5100 SCOPE IWL- 5200 SYSTEM TEST REQUIREMENTS IWL- 5210 GENERAL IWL- 5220 TEST PRESSURE IWL- 5230 LEAKAGE TEST IWL- 5250 TEST PROCEDURE AND EXAMINATIONS IWL- 5260 CORRECTIVE ACTION IWL- 5300 REPORT |
268 | MANDATORY APPENDICES MANDATORY APPENDIX I ULTRASONIC EXAMINATIONS |
276 | MANDATORY APPENDIX II OWNER’S REPORT FOR INSERVICE INSPECTIONS |
285 | MANDATORY APPENDIX III ULTRASONIC EXAMINATION OF VESSEL AND PIPING WELDS |
296 | MANDATORY APPENDIX IV EDDY CURRENT EXAMINATION |
307 | MANDATORY APPENDIX V SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE |
309 | MANDATORY APPENDIX VI QUALIFICATION OF PERSONNEL FOR VISUAL EXAMINATION ARTICLE VI- 1000 INTRODUCTION AND SCOPE |
315 | MANDATORY APPENDIX VII QUALIFICATION OF NONDESTRUCTIVE EXAMINATION PERSONNEL FOR ULTRASONIC EXAMINATION |
325 | MANDATORY APPENDIX VIII PERFORMANCE DEMONSTRATION FOR ULTRASONIC EXAMINATION SYSTEMS ARTICLE VIII- 1000 SCOPE |
353 | ARTICLE IX- 2000 DEFECT CHARACTERIZATION |
358 | MANDATORY APPENDIX X STANDARD UNITS FOR USE IN EQUATIONS |
359 | NONMANDATORY APPENDICES NONMANDATORY APPENDIX A ANALYSIS OF FLAWS |
382 | NONMANDATORY APPENDIX C EVALUATION OF FLAWS IN PIPING |
428 | NONMANDATORY APPENDIX D CONDITIONING OF CLASSES 1 AND 2 PIPING WELDS WHICH REQUIRE EXAMINATION |
431 | NONMANDATORY APPENDIX E EVALUATION OF UNANTICIPATED OPERATING EVENTS |
433 | NONMANDATORY APPENDIX G FRACTURE TOUGHNESS CRITERIA FOR PROTECTION AGAINST FAILURE |
444 | NONMANDATORY APPENDIX H EVALUATION PROCEDURES FOR FLAWS IN PIPING BASED ON USE OF A FAILURE ASSESSMENT DIAGRAM |
454 | NONMANDATORY APPENDIX J GUIDE TO PLANT MAINTENANCE ACTIVITIES AND SECTION XI REPAIR/ REPLACEMENT ACTIVITIES |
459 | NONMANDATORY APPENDIX K ASSESSMENT OF REACTOR VESSELS WITH LOW UPPER SHELF CHARPY IMPACT ENERGY LEVELS |
471 | NONMANDATORY APPENDIX L OPERATING PLANT FATIGUE ASSESSMENT L- 1100 SCOPE L- 1200 EVALUATION METHODS L- 1300 NOMENCLATURE |
479 | NONMANDATORY APPENDIX M APPLYING MATHEMATICAL MODELING TO ULTRASONIC EXAMINATION OF PRESSURE RETAINING COMPONENTS |
481 | NONMANDATORY APPENDIX N WRITTEN PRACTICE DEVELOPMENT FOR QUALIFICATION AND CERTIFICATION OF NDE PERSONNEL |
486 | NONMANDATORY APPENDIX O EVALUATION OF FLAWS IN PWR REACTOR VESSEL HEAD PENETRATION NOZZLES O- 1100 SCOPE O- 1200 PROCEDURE |
491 | NONMANDATORY APPENDIX P GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE |
494 | NONMANDATORY APPENDIX Q WELD OVERLAY REPAIR OF CLASSES 1, 2, AND 3 AUSTENITIC STAINLESS STEEL PIPING WELDMENTS |
499 | NONMANDATORY APPENDIX R RISK- INFORMED INSPECTION REQUIREMENTS FOR PIPING |
529 | NONMANDATORY APPENDIX S EVALUATING COVERAGE FOR SECTION XI NONDESTRUCTIVE EXAMINATION |
533 | NONMANDATORY APPENDIX T REPORTING OF CONTRACTED REPAIR/ REPLACEMENT ACTIVITIES ARTICLE T- 1000 INTRODUCTION |
538 | DIVISION 2 RULES FOR INSPECTION AND TESTING OFCOMPONENTS OF GAS-COOLED PLANTS |
540 | DIVISION 3 RULES FOR INSPECTION AND TESTING OF COMPONENTS OF LIQUID-METAL-COOLED PLANTS |
542 | INTERPRETATIONS Volume 60 |