Shopping Cart

No products in the cart.

ASME PTC 12.4 1992 R2014

$98.04

ASME PTC 12.4 Moisture Separator Reheaters (MSRs) – Reaffirmed: 2014

Published By Publication Date Number of Pages
ASME 1992 64
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Code provides the procedures, direction, and guidance for the accurate testing of Moisture Separator Reheaters (MSRs) which includes moisture separating and steam reheating components located between the high pressure and low pressure steam turbine. The purpose of the Code is to determine the performance of the MSR and to provide guidance in the evaluation of its performance effect on the turbine cycle heat with regard to: (a) Moisture Separator Outlet Quality; (b) Reheater Terminal Temperature Difference (TTD) per stage; (c) Cycle Steam pressure drop across applicable component(s); and (d) Excess heating steam flow. Requirements are specified by this Code for application on MSR testing in the following areas: (a) Pretest arrangements and agreements; (b) Instrumentation types and accuracies; (c) Instrumentation applications and methods of measurement; (d) Testing and calculation techniques; (e) Information contained in the report.

PDF Catalog

PDF Pages PDF Title
3 Foreword
4 Committee Roster
6 CONTENTS
8 0 Introduction
9 1 Object and Scope
1.1 Object
1.2 Scope
1.3 Expected Measurement Uncertainty
10 2 Definitions and Description of Terms
2.1 Nomenclature
2.2 Definitions
12 3 Guiding Principles
3.1 Preparation for the Test
13 3.2 General Test Requirements
3.3 Test Operating Conditions
14 3.4 Test Techniques
Tables
3.1Permissible Deviation of Variables.
16 Figures
3.1 Typical Test Point Locations
18 4 Instrumentation and Methods of Measurement
4.1 General Considerations
4.2 Measurement of Pressure
19 4.3 Measurement of Differential Pressure
4.1 Water Leg Determination..
20 4.4 Measurement of Temperature
21 4.5 Measurement of Steam Quality
4.6 Flow Rate Determinations
25 4.2 Injection and Sampling Point Locations – MSR Two-Pass Arrangement. .
26 4.3 Injection and Sampling Point Locations – MSR Four-Pass Arrangement.
27 4.4 Typical Installation of Injection and Sampling Points.
28 4.5 Oxygen Content of Sample
29 4.7 Measurement of Water Levels
30 5 Computation of Results
5.1 MSR Performance Computation
5.2 Component Pressure Drop
5.3 Terminal Temperature Difference
31 5.4 Moisture Separator Outlet Quality
32 5.1 Moisture Separator Reheater – Typical Data Point Locations.
33 5.5 Reference Values
5.6 Sensitivity of Deviation from the Reference Value
5.1 MSR Performance Computations
34 6 Test Report
6.1 Introduction
37 Appendices
A Sample Calculation
57 B Measurement.Uncertainty Calculations
ASME PTC 12.4 1992 R2014
$98.04