ASSE 1013 2011

$24.38

ASSE Standard #1013-2011 Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers

Published By Publication Date Number of Pages
ASSE 2011 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Standard applies to Reduced Pressure Principle Backflow Preventers (RP) and Reduced Pressure Principle Fire Protection Backflow Preventers (RPF). These assemblies consist of two (2) independently-acting check valves, internally force loaded to a normally closed position and separated by an intermediate chamber (or zone) in which there is a hydraulically operated relief means for venting to atmosphere, internally force loaded to a normally open position. These assemblies are designed to operate under continuous pressure conditions. This standard also applies to Manifold Reduced Pressure Principle Backflow Assemblies consisting of two (2) or more complete Reduced Pressure Principle Backflow Preventers in parallel.

PDF Catalog

PDF Pages PDF Title
11 Section I
1.0 General
1.1 Application
1.2 Scope
12 Table 1
13 1.3 Limitations on Design
14 1.4 Reference Standards
16 Section II
2.0 Test Specimens
2.1 Samples Submitted for Test
2.2 Samples Tested
2.3 Drawings
2.4 Rejection
2.5 Manifold Assembly
17 Section III
3.0 Performance Requirements and Compliance Testing
3.1 Independence of Components
3.2 Hydrostatic Test of Complete Assembly
3.3 Seat Leakage Test for Shut-off Valves
18 3.4 Hydrostatic Backpressure Test of Checks
3.5 Allowable Pressure Loss at Rated Flow
19 Figure 1
Figure 1A
20 3.6 Relief Valve Opening Test
21 3.7 Sensitivity of Differential Pressure Relief Valve Test
3.8 Drip Tightness of First Check
22 3.9 Drip Tightness of Second Check
3.10 Relief Valve Discharge Test with Atmospheric Supply Pressure
3.11 Relief Valve Discharge with Positive Supply Pressure
23 Table 2
24 3.12 Backpressure/Backsiphonage Test
3.13 Relief Valve vs. Supply Pressure Fluctuation Test for Type RPF Assemblies Only
3.14 Air Gap Device Backsiphonage Test
25 3.15 Deterioration at Manufacturer’s Extremes of Temperature and Pressure Ranges
26 Table 3
27 3.16 Cycle Test
28 3.17 Body Strength Test for Type RPF Assemblies
3.18 Seat Adhesion Test for Type RPF Assemblies
29 3.19 High Velocity Test for Type RPF Assemblies
3.20 Field Evaluation Test for RP and RPF Devices When Required by the Authority
Having Jurisdiction
31 Section IV
4.0 Detailed Requirements
4.1 Materials
32 4.2 Grooved Connections
4.3 Marking Instructions
4.4 Installation and Maintenance Instructions
33 Section V
5.0 Definitions
34 viii Reduced Pressure Principle Backflow Preventers and
Reduced Pressure Principle Fire Protection Backflow Preventers
ASSE 1013-2011
Appendix A – Installation Guidelines
A1.0 Recommended Installation Guidelines
A1.1 General
A1.2 Orientation
35 A1.3 Side Clearances