ASTM-A275 2006
$40.63
A275/A275M-06 Standard Test Method for Magnetic Particle Examination of Steel Forgings
Published By | Publication Date | Number of Pages |
ASTM | 2006 | 7 |
ASTM A275/A275M-06
Historical Standard: Standard Test Method for Magnetic Particle Examination of Steel Forgings
ASTM A275/A275M
Scope
1.1 This test method covers a procedure for magnetic particle examination of steel forgings. The procedure will produce consistent results upon which acceptance standards can be based. This standard does not contain acceptance standards or recommended quality levels.
1.2 Only direct current or rectified alternating (full or half wave) current shall be used as the electric power source for any of the magnetizing methods. Alternating current is not permitted because its capability to detect subsurface discontinuities is very limited and therefore unsuitable.
1.2.1 Portable battery powered electromagnetic yokes are outside the scope of this test method.
Note 1āGuide E 709 may be utilized for magnetic particle examination in the field for machinery components originally manufactured from steel forgings.
1.3 The minimum requirements for magnetic particle examination shall conform to practice standards of Practice E 1444. If the requirements of this test method are in conflict with the requirements of Practice E 1444, the requirements of this test method shall prevail.
1.4 This specification and the applicable material specifications are expressed in both inch-pound units and SI units. However, unless the order specifies the applicable “M” specification designation [SI units], the material shall be furnished to inch-pound units.
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; hterefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
ICS Code
ICS Number Code 77.040.20 (Non-destructive testing of metals)
DOI: 10.1520/A0275_A0275M-06
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Basis of Application Personnel Requirements Stage of Inspection Magnetizing Apparatus Magnetic Particles Surface Preparation Methods of Magnetization |
3 | FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 |
4 | Application of Particles FIG. 7 |
5 | Demagnetization FIG. 8 |
6 | Interpretation and Evaluation of Indications Report of Indications Acceptance Standards |