ASTM-C1290:2011 Edition

$35.75

C1290-11 Standard Specification for Flexible Fibrous Glass Blanket Insulation Used to Externally Insulate HVAC Ducts

Published By Publication Date Number of Pages
ASTM 2011 4
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM C1290-11

Historical Standard: Standard Specification for Flexible Fibrous Glass Blanket Insulation Used to Externally Insulate HVAC Ducts

ASTM C1290

Scope

1.1 This specification covers the composition, size, dimensions, and physical properties of flexible fiber glass blanket, ductwrap, used to externally insulate HVAC ducts used for the distribution of condition air within the temperature range of 35°F (1.7°C) and 250°F (121°C).

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 When the installation and use of thermal insulation materials, accessories, and systems may pose safety and health problems, the manufacturer shall provide the user appropriate current information regarding any known problems associated with the recommended use of the company’s products, and shall also recommend protective measures to be employed in their safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

1.4 The following safety hazards caveat pertains only to the test methods, Section 13, in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

blanket; ducts; fibrous glass; insulation; thermal resistance; Blanket thermal insulation; Ducts/duct liners; Fibrous glass materials/applications (specifications); Flexibility–insulation; Flexible thermal insulation; HVAC (heating/ventilation/air conditioning) systems; Thermal insulating materials–specifications; Thermal insulating materials (blanket); Thermal resistance/resistivity

ICS Code

ICS Number Code 27.220 (Heat recovery. Thermal insulation)

DOI: 10.1520/C1290-11

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Classification
2 Ordering Information
Materials and Manufacture
Physical Properties
Dimensional Tolerances
Sampling
Inspection
Qualification and Inspection Requirements
Workmanship and Finish
TABLE 1
3 Test Methods
Rejection and Rehearing
Certification
Product Marking
Packaging and Package Marking
Keywords
X1. INSULATION INSTALLATION STRETCH-OUT SCHEDULE
X1.1
X1.2
4 TABLE X1.1
ASTM-C1290