ASTM-C1484:2009 Edition

$40.63

C1484-09 Standard Specification for Vacuum Insulation Panels

Published By Publication Date Number of Pages
ASTM 2009 10
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM C1484-09

Historical Standard: Standard Specification for Vacuum Insulation Panels

ASTM C1484

Scope

1.1 This specification covers the general requirements for Vacuum Insulation Panels (VIP). These panels have been used wherever high thermal resistance is desired in confined space applications, such as transportation, equipment, and appliances.

1.2 Vacuum panels typically exhibit an edge effect due to differences between panel core and panel barrier thermal properties. This specification applies to composite panels whose center-of-panel apparent thermal resistivities (sec. 3.2.3) typically range from 87 to 870 m·K/W at 24°C mean, and whose intended service temperature boundaries range from 70 to 480°C.

1.3 The specification applies to panels encompassing evacuated space with: some means of preventing panel collapse due to atmospheric pressure, some means of reducing radiation heat transfer, and some means of reducing the mean free path of the remaining gas molecules.

1.4 Limitations

1.4.1 The specification is intended for evacuated planar composites; it does not apply to non-planar evacuated self-supporting structures, such as containers or bottles with evacuated walls.

1.4.2 The specification describes the thermal performance considerations in the use of these insulations. Because this market is still developing, discrete classes of products have not yet been defined and standard performance values are not yet available.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health specifications and determine the applicability of regulatory limitations prior to use. For specific safety considerations see Annex A1.

Keywords

adsorbent; effective thermal resistance (effective R-value); superinsulation; thermal conductivity; thermal resistance; vacuum insulation; Thermal insulating materials–specifications; Vacuum insulation panels

ICS Code

ICS Number Code 91.060.10 (Walls. Partitions. Facades)

DOI: 10.1520/C1484-09

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
FIG. 1
3 Ordering Information
Materials and Manufacture
4 Physical and Mechanical Properties
Dimensions and Tolerances
Workmanship and Finish
Sampling
Qualification Requirements
Test Methods
TABLE 1
5 Inspection
Rejection and Resubmittal
Packaging and Marking
6 Keywords
A1. ADDITIONAL SAFETY CONSIDERATIONS
A1.1
A1.2
A1.3
X1. PANEL AGING CALCULATIONS
X1.1
X1.2
X1.3
7 X1.4
X1.5
FIG. X1.1
8 X1.6
X1.7
X1.8
X2. ADDITIONAL TESTING
X2.1
X2.2
X2.3
9 X3. MEASUREMENT TECHNIQUE FOR PANEL BARRIER PERMEABILITY
X3.1
X3.2
X4. HISTORY OF THE SPECIFICATION
X4.1
10 REFERENCES
ASTM-C1484
$40.63