ASTM-C223 2008
$35.75
C223-98(2008) Standard Specification for Asbestos-Cement Siding
Published By | Publication Date | Number of Pages |
ASTM | 2008 | 3 |
1.1 This specification covers asbestos-cement siding, including accessories, designed to provide the weather-exposed sidewall surfaces of buildings. Siding in the following forms is covered:
1.1.1 Siding Shingles Uniform thickness, generally rectangular in shape and having wavy, random, thatched, straight, or irregular butts.
1.1.2 Clapboards Uniform thickness, generally longer and narrower in shape than siding shingles, and usually with the exposed edge straight.
1.1.3 Sheets Uniform thickness, rectangular in shape, larger in unit sizes than shingles or clapboards.
Note 1For additional information, see Specification C 725 for Semidense Mineral Fiber Siding.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 Warning Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to Safe Use of Chrysotile: A Manual on Preventive and Control Measures.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Physical Requirements Dimensions, Mass, and Permissible Variations |
2 | Workmanship, Finish, and Appearance Nails and Fasteners Underlayment Sheet Composition Requirements Rejection and Retesting Inspection Packaging and Shipping TABLE 1 TABLE 2 |
3 | Keywords |