ASTM-C225 2004
$40.63
C225-85(2004) Standard Test Methods for Resistance of Glass Containers to Chemical Attack
Published By | Publication Date | Number of Pages |
ASTM | 2004 | 7 |
ASTM C225-85-Reapproved2004
Historical Standard: Standard Test Methods for Resistance of Glass Containers to Chemical Attack
ASTM C225
Scope
1.1 These test methods cover the evaluation of the resistance of glass containers to chemical attack. Three test methods are presented, as follows:
1.1.1 Test Method B-A covers autoclave tests at 121Ā°C on bottles partially filled with dilute acid as the attacking medium.
1.1.2 Test Method B-W covers autoclave tests at 121Ā°C on bottles partially filled with distilled water as the attacking medium.
1.1.3 Test Method P-W covers autoclave tests at 121Ā°C on powdered samples with pure water as the attacking medium.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
chemical attack; containers; durability; glass
ICS Code
ICS Number Code 81.040.30 (Glass products)
DOI: 10.1520/C0225-85R04
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Significance and Use |
2 | Purity of Reagents Apparatus Reagents and Materials |
3 | Preparation of Sample Procedure Calculation and Report Apparatus Reagents Preparation of Sample Procedure Calculation and Report Apparatus |
4 | Reagents FIG. 1 FIG. 2 |
5 | Preparation of Sample FIG. 3 |
6 | Procedure Calculation and Report FIG. 4 |
7 | Precision and Bias Keywords |