C598-93(2008) Standard Test Method for Annealing Point and Strain Point of Glass by Beam Bending

Published By Publication Date Number of Pages
ASTM 2008 5
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method covers the determination of the annealing point and the strain point of a glass by measuring the rate of midpoint viscous bending of a simply loaded glass beam. However, at temperatures corresponding to the annealing and strain points, the viscosity of glass is highly time-dependent. Hence, any viscosities that might be derived or inferred from measurements by this procedure cannot be assumed to represent equilibrium structural conditions.

1.2 The annealing and strain points shall be obtained following a specified procedure after direct calibration of the apparatus using beams of standard glasses having known annealing and strain points such as those supplied and certified by the National Institute of Standards and Technology.

1.3 This test method, as an alternative to Test Method C 336 is particularly well suited for glasses that for one reason or another are not adaptable for flame working. It also has the advantages that thermal expansion and effective length corrections, common to the fiber elongation method, are eliminated.

1.4 The values stated in metric units are to be regarded as the standard. The values given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
Apparatus
FIG. 1
3 Preparation of Test Specimen
Calibration and Measurement with Standard Glass
Procedure
FIG. 2
4 Interpretation of Results
Report
Precision and Bias
FIG. 3
FIG. 4
5 X1. MOMENT OF INERTIA, Ic, FORMULAS FOR VARIOUS CROSS-SECTION GEOMETRIES
X2. VERIFICATION OF SPECIMEN STAND AND LOADING ROD
X2.1