Shopping Cart

No products in the cart.

ASTM-C783 2010

$27.50

C783-85(2010)e1 Standard Practice for Core Sampling of Graphite Electrodes

Published By Publication Date Number of Pages
ASTM 2010 2
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This practice was developed for electric-arc furnace graphite electrodes, and covers a procedure and equipment for obtaining core samples from electrodes in a manner that does not destroy the electrode nor prevent its subsequent use as originally intended. However, the minimum electrode diameter, for which extraction of a core sample using this practice does not influence subsequent use, is influenced by the particular application and must be determined by the user. Graphite electrodes for use in electric arc furnaces are usually solid cylinders of graphite with threaded sockets machined in each end.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1The following ASTM standards are noted as sources of useful information: Test Methods C559 , C611 , C651 , C747 , C1025 , and C1039 .

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Significance and Use
Apparatus
Procedure
2 Keywords
FIG. 1
ASTM-C783 2010
$27.50