ASTM-D1929:1996 Edition
$40.63
D1929-96 Standard Test Method for Determining Ignition Temperature of Plastics
Published By | Publication Date | Number of Pages |
ASTM | 1996 | 5 |
ASTM D1929-96
Historical Standard: Standard Test Method for Determining Ignition Temperature of Plastics
ASTM D1929
Scope
1.1 This fire test response test methodĀ² covers a laboratory determination of the flash ignition temperature and spontaneous ignition temperature of plastics using a hot-air furnace.
1.2 Caution-During the course of combustion, gases or vapors, or both, are evolved that may be hazardous to personnel. Adequate precautions should be taken to protect the operator.
1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazards or fire risk assessment of materials, products, or assemblies under actual fire conditions.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.2 and 1.4.
Note 1- This test method and ISO 871-1996 are identical in all technical details.
Keywords
flash ignition temperature; ignition temperature; spontaneous ignition temperature
ICS Code
ICS Number Code n/a
DOI: 10.1520/D1929-96