D2303-97(2004) Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials
Published By | Publication Date | Number of Pages |
ASTM | 2004 | 10 |
ASTM D2303-97-Reapproved2004
Historical Standard: Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials (Withdrawn 2013)
ASTM D2303
Scope
1.1 These test methods cover the evaluation of the relative tracking and erosion resistance of insulating solids using the liquid-contaminant, inclined-plane test. The following test methods also can be used to evaluate the tracking resistance of materials: D 2132 (contaminants: dust and fog) and D 3638 (contaminant: conductive liquid drops).
1.2 Two tracking and one erosion test procedure are described:
1.2.1 A “variable voltage method” to evaluate resistance to tracking.
1.2.2 A “time-to-track method” to evaluate resistance to tracking.
1.2.3 A method for quantitative determination of erosion ().
1.3 While a particular contaminant solution is specified, other concentrations of the same contaminant, or different contaminants may be used to simulate different environmental or service conditions.
1.4 The values stated in inch-pound units are to be regarded as the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8.
Keywords
electrical; erosion; erosion resistance; inclined-plane; liquid contaminant; surface arcing; surface tracking; time-to-track method; track; tracking; tracking resistance; tracking voltage; voltage method; wet tracking
ICS Code
ICS Number Code 29.035.01 (Insulating materials in general)
DOI: 10.1520/D2303-97R04
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Significance and Use |
2 | Apparatus Sampling Test Specimens |
3 | Procedure FIG. 1 |
4 | TABLE 1 |
5 | FIG. 2 FIG. 3 |
6 | Initial Tracking Voltage Test Method Time-to-Track Test Method Report FIG. 4 FIG. 5 |
7 | Precision and Bias Keywords FIG. 6 |
8 | A1. EROSION TEST METHOD A1.1 A1.2 A1.3 FIG. 7 |
9 | A1.4 Report A2. DETAILS OF CONTAMINANT SOURCE AND ITS CALIBRATION A2.1 Outline A2.2 Components A2.3 Mechanical Details—Solenoid-Valve Air System |
10 | A2.5 Calibration Method A2.6 Maintenance and Diagnosis |