D3382-07 Standard Test Methods for Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques

Published By Publication Date Number of Pages
ASTM 2007 8
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover two bridge techniques for measuring the energy and integrated charge of pulse and pseudoglow partial discharges:

1.2 Test Method A makes use of capacitance and loss characteristics such as measured by the transformer ratio-arm bridge or the high-voltage Schering bridge (Test Methods D 150). Test Method A can be used to obtain the integrated charge transfer and energy loss due to partial discharges in a dielectric from the measured increase in capacitance and tan with voltage. (See also IEEE 286 and IEEE 1434)

1.3 Test Method B makes use of a somewhat different bridge circuit, identified as a charge-voltage-trace (parallelogram) technique, which indicates directly on an oscilloscope the integrated charge transfer and the magnitude of the energy loss due to partial discharges.

1.4 Both test methods are intended to supplement the measurement and detection of pulse-type partial discharges as covered by Test Method D 1868, by measuring the sum of both pulse and pseudoglow discharges per cycle in terms of their charge and energy.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precaution statements are given in Section 7.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Methods
Significance and Use
Sources of Errors
3 Hazards
Procedure
Precision and Bias
Interferences
FIG. 1
4 Procedure
Calibration of Oscilloscope Coefficients
FIG. 2
FIG. 3
5 Calculation
Report
Precision and Bias
Keywords
A1. LIST OF SYMBOLS
6 A2. CIRCUIT COMPONENTS AND MEASUREMENT PROCEDURE FOR TEST METHOD B (SEE
A2.1 Apparatus
A2.2 High-Voltage Divider
A2.3 Oscilloscope
A2.4 High-Voltage Transformer
A2.5 Measurement Procedure
7 A3. ADDITIONAL MEASUREMENT ANALYSIS (TEST METHOD B)
A3.1
A3.2
A3.3
REFERENCES