ASTM-D4566 2020(Redline)
$58.50
D4566-20 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable (Redline)
Published By | Publication Date | Number of Pages |
ASTM | 2020 | 54 |
ASTM D4566-20
Redline Standard: Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
ASTM D4566
Scope
1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product.
1.2 These test methods appear in the following sections of this standard:
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections 7 and 38.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
aging; attenuation; attenuation to crosstalk ratio far-end; attenuation to crosstalk ratio near-end; capacitance deviation; capacitance difference; capacitance unbalance pair-to-ground; capacitance unbalance pair-to-pair; capacitance unbalance pair-to-support wire; characteristic impedance; coaxial capacitance; conductor resistance; conductor resistance unbalance; continuity; conversion loss; crosses; crosstalk loss—far end; crosstalk loss—near end; dc proof test; equal level far-end crosstalk; equal level longitudinal conversion transfer loss (EL LCTL); equal level transverse conversion transfer loss (EL TCTL); equal level unbalance attenuation far-end; equal level unbalance attenuation near-end; fault rate test; humidity; insulation defect; insulation resistance; jacket voltage breakdown; longitudinal conversion loss (LCL); longitudinal conversion transfer loss (LCTL); mutual capacitance; mutual conductance; phase constant; phase delay; phase velocity; shorts test; spark test; structural return loss; transverse conversion loss (TCL); transverse conversion transfer loss (TCTL); unbalance attenuation far-end; unbalance attenuation near-end; voltage surge test ;
ICS Code
ICS Number Code 29.035.01 (Insulating materials in general)
DOI: 10.1520/D4566-20