ASTM-D5464 2011

$44.96

D5464-11 Standard Test Method for pH Measurement of Water of Low Conductivity

Published By Publication Date Number of Pages
ASTM 2011 11
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method is applicable to determine the pH of water samples with a conductivity of 2 to 100 ? S/cm over the pH range of 3 to 11. pH measurements of water of low conductivity are problematic. Specifically, this test method avoids contamination of the sample with atmospheric gases and prevents volatile components of the sample from escaping. This test method provides for pH electrodes and apparatus that address additional considerations discussed in Annex A2. This test method also minimizes problems associated with the sample’s pH temperature coefficient when the operator uses this test method to calibrate an on-line pH monitor or controller (see Appendix X1).

1.2 This test method covers the measurement of pH in water of low conductivity with a lower limit of 2.0 ? S/cm, utilizing a static grab-sample procedure where it is not practicable to take a real-time flowing sample.

Note 1Test Method D5128 for on-line measurement is preferred over this method whenever possible. Test Method D5128 is not subject to the limited conductivity range, temperature interferences, potential KCl contamination, and time limitations found with this method.

1.3 For on-line measurements in water with conductivity of 100 ? S/cm and higher, see Test Method D6569 .

1.4 For laboratory measurements in water with conductivity of 100 ? S/cm and higher, see Test Method D1193 .

1.5 The values stated in SI units are to be regarded as standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Reagents
2 Summary of Test Method
Significance and Use
Interferences
3 Apparatus
Sampling and Sample Handling
Calibration
Procedure
4 Quality Control
Precision and Bias
Keywords
FIG. 1
5 A1. DISCUSSION OF THE CONDUCTIVITY RANGE FOR THIS TEST METHOD
A1.1
TABLE A1.1
6 A2. CONSIDERATIONS FOR THE REQUIREMENT OF SPECIALIZED pH MEASUREMENT APPARATUS
A2.1
A2.2
TABLE A1.2
7 X1. TEMPERATURE EFFECTS IN PURE WATER
X1.1
X1.2
X1.3
X1.4
TABLE X1.1
8 X1.5
X2. SUPPLEMENT FOR GRAB SAMPLE CALIBRATION (GSC) OF ON-LINE pH SENSORS
X2.1
X2.2
X2.3
TABLE X1.2
9 X2.4
X2.5
X3. EFFECTS OF CO2 ON pH MEASUREMENTS OF HIGH PURITY WATER
X3.1
10 FIG. X3.1
11 REFERENCES
TABLE X3.1
ASTM-D5464 2011