Shopping Cart

No products in the cart.

ASTM-D6056 2001

$40.63

D6056-96(2001) Standard Test Method for Determining Concentration of Airborne Single-Crystal Ceramic Whiskers in the Workplace Environement by Transmission Electron Microscopy

Published By Publication Date Number of Pages
ASTM 2001 8
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM D6056-96-Reapproved2001

Historical Standard: Standard Test Method for Determining Concentration of Airborne Single-Crystal Ceramic Whiskers in the Workplace Environement by Transmission Electron Microscopy

ASTM D6056

Scope

1.1 This test method covers the sampling methods and analysis techniques used to assess the airborne concentration and size distribution of single-crystal ceramic whiskers (SCCW), such as silicon carbide and silicon nitride, which may occur in and around the workplace where these materials are manufactured, processed, transported, or used. This test method is based on the filtration of a known quantity of air through a filter. The filter is subsequently evaluated with a transmission electron microscope (TEM) for the number of fibers meeting appropriately selected morphological and compositional criteria. This test method has the ability to distinguish among different types of fibers based on energy dispersive X-ray spectroscopy (EDS) analysis and selected area electron diffraction (SAED) analysis. This test method may be appropriate for other man-made mineral fibers (MMMF).

1.2 This test method is applicable to the quantitation of fibers on a collection filter that are greater than 0.5 µm in length, less than 3 &#956m in width, and have an aspect ratio equal to or greater than 5:1 (1). The data are directly convertible to a statement of concentration per unit volume of air sampled. This test method is limited by the amount of coincident interference particles.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

air monitors; sampling and analysis; silicon-carbide whiskers; single-crystal ceramic whiskers; transmission electron microscopy; workplace atmosphere

ICS Code

ICS Number Code 13.040.30 (Workplace atmospheres)

DOI: 10.1520/D6056-96R01

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Method
Significance and Use
Interferences
Apparatus and Reagents
3 Sample Collection
Transport of Samples
Specimen Preparation
4 Analysis Method
5 Quality Control
7 Calculations
Precision and Bias
8 Keywords
REFERENCES
ASTM-D6056 2001