ASTM-D7203 2017

$44.96

D7203-11(2017) Standard Practice for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor

Published By Publication Date Number of Pages
ASTM 2017 14
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM D7203-11-Reapproved2017

Withdrawn Standard: Standard Practice for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor (Withdrawn 2022)

ASTM D7203

Scope

1.1 This practice describes procedures for screening media known to contain the halogenated volatile organic compound (HVOC), trichloroethylene (TCE). Procedure A is to be used for screening soil known to contain TCE and Procedure B is to be used for screening water known to contain TCE.

1.1.1 Both Procedures A and B involve measuring the TCE concentration in the headspace above a sample using a heated diode sensor device. From this measurement, an estimated concentration of TCE in the sample can be determined. Any TCE remaining in the sample is not measured. Any other HVOC present in the sample will be reported as TCE.

1.2 Procedure A can also be used for screening the headspace above a soil suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the soil. Procedure B can also be used for screening the headspace above a water suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the water. For both procedures, any HVOC contamination remaining in the soil or water is not detected by this practice.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3.1 Exceptionā€”Certain inch-pound units are provided for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

Note 1: The diode sensor is heated to temperatures ranging between approximately 600 and 1000 Ā°C (see 6.1.5) and as a result could be a source of ignition.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

field screening; halogenated volatile organic compounds (HVOCs); heated diode sensor; soils; trichloroethylene (TCE); water;

ICS Code

ICS Number Code 13.080.10 (Chemical characteristics of soil)

DOI: 10.1520/D7203-11R17