ASTM-D7237 2010

$40.63

D7237-10 Standard Test Method for Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection

Published By Publication Date Number of Pages
ASTM 2010 8
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method is used to establish the concentration of free cyanide in an aqueous wastewater or effluent. The test conditions of this method are used to measure free cyanide (HCN and CN ) and cyanide bound in the metal-cyanide complexes that are easily dissociated into free cyanide ions at the pH of 6. Free cyanide is determined at pH 6 at room temperature. The aquatic free cyanide can be determined by matching the pH to the water in the receiving environment in the range of pH 6 to 8. The extent of HCN formation is less dependent on temperature than the pH; however, the temperature can be regulated if deemed necessary for aquatic free cyanide to further simulate the actual aquatic environment.

1.2 The free cyanide method is based on the same instrumentation and technology that is described in standard test method D6888 , but employs milder conditions (pH 6-8 buffer versus HCl or H 2 SO 4 in the reagent stream), and does not utilize ligand displacement reagents.

1.3 The aquatic free cyanide measured by this procedure should be similar to actual levels of HCN in the original aquatic environment. This in turn may give a reliable index of toxicity to aquatic organisms.

1.4 This procedure is applicable over a range of approximately 2 to 500 ? g/L (parts per billion) free cyanide. Sample dilution may increase cyanide recoveries depending on the cyanide speciation; therefore, it is not recommended to dilute samples. Higher concentrations can be analyzed by increasing the range of calibration standards or with a lower injection volume. In accordance with Guide E1763 and Practice D6512 the lower scope limit was determined to be 9 ? g/L for chlorinated gold leaching barren effluent water.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 8.6 and Section 9 .

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Method
Significance and Use
Interferences
Apparatus
FIG. 1
3 Reagents and Materials
TABLE 1
4 Hazards
Sample and Sample Preservation
Elimination of Interferences
Calibration and Standardization
5 Procedure
Data Analysis and Calculations
Precision and Bias
Quality Assurance and Quality Control
TABLE 2
6 TABLE 3
TABLE 4
TABLE 5
TABLE 6
7 Keywords
TABLE 7
TABLE 8
TABLE 9
ASTM-D7237 2010
$40.63