Shopping Cart

No products in the cart.

ASTM-D876 2009

$44.96

D876-09 Standard Test Methods for Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation

Published By Publication Date Number of Pages
ASTM 2009 13
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C) nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation. For the purpose of these test methods nonrigid tubing shall be tubing having an initial elongation in excess of 100 % at break.

Note 1These test methods are similar but not identical to those in IEC 60684 2.

1.2 The values stated in inch-pound units are to be regarded as standard, except for temperature, which shall be expressed in degrees Celsius. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 The procedures appear in the following sections:

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.

1.5 For fire test caveats, see Section 15 .

15.1 This is a fire-test-response standard. The test procedure described measures the resistance of the tubing to ignition or the spread of flame after ignition when tested under the specified conditions.

15.2 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

15.3 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

25.1 The effect of elevated temperature is indicated by the changes in ultimate elongation and weight caused by exposure of the tubing to elevated temperatures for a specified time under controlled conditions of air circulation.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
Hazards
Sampling
Test Conditions
Significance and Use
Apparatus
Test Specimens
Procedure for Measuring Inside Diameter
3 Procedure for Measuring Outside Diameter
Report
Precision and Bias
Scope
Significance and Use
Apparatus
TABLE 1
4 Test Specimens
Procedure
Report
FIG. 1
5 Precision and Bias
Procedure
Report
Precision and Bias
Scope
Significance and Use
Apparatus
6 Test Specimens
Procedure
Report
Precision and Bias
Apparatus
Test Specimens
Procedure
Report
Precision and Bias
Significance and Use
Apparatus
7 Test Specimens
Procedure
Report
Precision and Bias
Significance and Use
Procedure
Precision and Bias
Significance and Use
Apparatus
8 Test Specimens
Procedure
Report
FIG. 2
9 Precision and Bias
Significance and Use
Apparatus
Test Specimens
Procedure
Report
Precision and Bias
Significance and Use
Dielectric Breakdown Voltage
Apparatus
Test Specimens and Conditioning
Procedure
10 Report
Precision and Bias
Procedure
Report
Precision and Bias
Significance and Use
Apparatus
Test Specimens
Procedure
Report
Precision and Bias
Significance and Use
11 Apparatus
Test Specimens and Conditioning
Procedure
FIG. 3
12 Report
Precision and Bias
Significance and Use
Apparatus
Test Specimens
Procedure
Report
Precision and Bias
Keywords
ASTM-D876 2009
$44.96