ASTM-D92 2005
$40.63
D92-05 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 10 |
1.1 This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus.
Note 1The precisions for fire point were not determined in the current interlaboratory program. Fire point is a parameter that is not commonly specified, although in some cases, knowledge of this flammability temperature may be desired.
1.2 This test method is applicable to all petroleum products with flash points above 79C (175F) and below 400C (752F) except fuel oils.
Note 2This test method may occasionally be specified for the determination of the fire point of a fuel oil. For the determination of the flash points of fuel oils, use Test Method D 93. Test Method D 93 should also be used when it is desired to determine the possible presence of small, but significant, concentrations of lower flash point substances that may escape detection by Test Method D 92. Test Method D 1310 can be employed if the flash point is known to be below 79C (175F).
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 11.1.3, and 11.2.4.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Summary of Test Method Significance and Use Apparatus |
3 | FIG. 1 FIG. 2 FIG. 3 |
4 | Reagents and Materials Sampling Preparation of Apparatus Calibration and Standardization |
5 | Procedure |
6 | Calculations Report |
7 | Precision and Bias Keywords A1. CLEVELAND OPEN CUP TESTER A1.1 A1.2 A1.3 A1.4 A1.5 |
8 | A1.6 A2. VERIFICATION OF APPARATUS PERFORMANCE A2.1 A2.2 X1. TECHNIQUE TO PREVENT SURFACE SKIN FORMATION WHEN TESTING FLASH POINT OF ASPHALTS BY TEST METHOD D 92 X1.1 Introduction X1.2 Materials Required TABLE A2.1 |
9 | X1.3 Procedure FIG. X1.1 |