Shopping Cart

No products in the cart.

ASTM-E1421:2009 Edition

$44.96

E1421-99(2009) Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

Published By Publication Date Number of Pages
ASTM 2009 12
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM E1421-99-Reapproved2009

Historical Standard: Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

ASTM E1421

Scope

1.1 This practice describes two levels of tests to measure the performance of laboratory Fourier transform mid-infrared (FT-MIR) spectrometers equipped with a standard sample holder used for transmission measurements.

1.2 This practice is not directly applicable to Fourier transform infrared (FT-IR) spectrometers equipped with various specialized sampling accessories such as flow cells or reflectance optics, nor to Fourier transform near-infrared (FT-NIR) spectrometers, nor to FT-IR spectrometers run in step scan mode.

1.2.1 If the specialized sampling accessory can be removed and replaced with a standard transmission sample holder, then this practice can be used. However, the user should recognize that the performance measured may not reflect that which is achieved when the specialized accessory is in use.

1.2.2 If the specialized sampling accessory cannot be removed, then it may be possible to employ a modified version of this practice to measure spectrometer performance. The user is referred to Guide E 1866 for a discussion of how these tests may be modified.

1.2.3 Spectrometer performance tests for FT-NIR spectrometers are described in Practice E 1944.

1.2.4 Performance tests for dispersive MIR instruments are described in Practice E 932.

1.2.5 For FT-IR spectrometers run in a step scan mode, variations on this practice and information provided by the instrument vendor should be used.

Keywords

Fourier transform infrared; FT-IR; level one test; level zero test; performance test; spectrometers; Performance–spectrochemical equipment; FTIR analysis; Infrared spectrophotometry; Level one/zero; Level zero/one; Transform infrared spectrometer

ICS Code

ICS Number Code n/a

DOI: 10.1520/E1421-99R09

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Significance and Use
2 Test Conditions
Level Zero Tests
3 Level Zero Test Procedures
4 FIG. 1
FIG. 2
5 FIG. 3
6 Level One Tests
FIG. 4
FIG. 5
7 Level One Test Procedures
FIG. 6
8 FIG. 7
9 FIG. 8
10 Keywords
FIG. 9
11 A1. CENTER OF GRAVITY ALGORITHM FOR PEAK LOCATION DETERMINATION
A1.1
A1.2 Collection and Computation of Spectra
A1.3 Peak Location Computations
FIG. A1.1
12 FIG. A1.2
ASTM-E1421
$44.96