Shopping Cart

No products in the cart.

ASTM-E1530:2006 Edition

$40.63

E1530-06 Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

Published By Publication Date Number of Pages
ASTM 2006 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E1530-06

Historical Standard: Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM E1530

Scope

1.1 This test method covers a steady-state technique for the determination of the resistance to thermal transmission (thermal resistance) of materials in thicknesses of less than 25 mm. For homogeneous opaque solid specimens of a representative thickness, thermal conductivity can be determined (see Note 0). This test method is useful for specimens having a thermal resistance in the range from 10 to 400 104 m 2K/W, which can be obtained from materials of thermal conductivity in the approximate range from 0.1 to 30 W/(mK) over the approximate temperature range from 150 to 600 K. It can be used outside these ranges with reduced accuracy for thicker specimens and for thermal conductivity values up to 60 W/(mK).

Note 0

A body is considered homogeneous when the property to be measured is found to be independent of specimen dimensions.

1.2 This test method is similar in concept to Test Method C 518, but is modified to accommodate smaller test specimens, having a higher thermal conductance. In addition, significant attention has been paid to ensure that the thermal resistance of contacting surfaces is minimized and reproducible.

1.3 The values stated in SI units are considered standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

heat flow meter; heat flux transducer; thermal conductance; thermal conductivity; thermal resistance; thin specimen

ICS Code

ICS Number Code 17.200.10 (Heat. Calorimetry)

DOI: 10.1520/E1530-06

PDF Catalog

PDF Pages PDF Title
1 Scope
Related Documents
Terminology
2 Summary of Test Method
Significance and Use
Apparatus
FIG. 1
3 Sampling and Conditioning
Test Specimen
Calibration
4 Procedure
TABLE 1
TABLE 2
5 Calculation
TABLE 3
6 FIG. 2
7 Report
Precision and Bias
Keywords
A1. TESTING OF THIN SPECIMENS LESS THAN 0.5 mm IN THICKNESS
A1.1
A1.2
A1.3
8 A1.4
A1.5
A2. TESTING OF LIQUIDS AND PASTES
A2.1
A2.2
A2.3
A2.4
A2.5
A3. SUMMARY OF INFORMATION FOR PRECISION AND BIAS STATEMENT
A3.1
A3.2
A3.3
TABLE A3.1
ASTM-E1530
$40.63