Shopping Cart

No products in the cart.

ASTM-E220 2007

$44.96

E220-07 Standard Test Method for Calibration of Thermocouples By Comparison Techniques

Published By Publication Date Number of Pages
ASTM 2007 15
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM E220-07

Historical Standard: Standard Test Method for Calibration of Thermocouples By Comparison Techniques

ASTM E220

Scope

1.1 This test method describes the principles, apparatus, and procedure for calibrating thermocouples by comparison with a reference thermometer. Calibrations are covered over temperature ranges appropriate to the individual types of thermocouples within an overall range from approximately 195 to 1700 Ā°C (320 to 3100 F).

1.2 In general, this test method is applicable to unused thermocouples. This test method does not apply to used thermocouples due to their potential material inhomogeneity-the effects of which cannot be identified or quantified by standard calibration techniques. Thermocouples with large-diameter thermoelements and sheathed thermocouples may require special care to control thermal conduction losses.

1.3 In this test method, all values of temperature are based on the International Temperature Scale of 1990. See Guide E 1594.

This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Keywords

calibration; comparison techniques; thermocouple; thermoelement

ICS Code

ICS Number Code 17.200.20 (Temperature-measuring instruments)

DOI: 10.1520/E0220-07

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Method
Significance and Use
Interferences
Apparatus
5 Reference Thermometers
6 TABLE 1
TABLE 2
7 Sampling
General Procedures
8 Preparation of Thermocouples for Test
FIG. 1
FIG. 2
10 Calibration Procedures
Calculations
11 Report
Uncertainty
TABLE 3
12 Keywords
TABLE 4
13 X1. APPARATUS
X1.1 Wire-Wound Electric Tube Furnaces
X1.2 Ceramic Element Electric Tube Furnaces
X2. REFERENCE THERMOMETERS
X2.1 Standard Platinum Resistance Thermometers
TABLE 5
14 X2.2 Industrial Platinum Resistance Thermometers
X2.3 Measurement Instruments for Resistance Thermometers
X2.4 Liquid-in-Glass Thermometers
X2.5 Thermistors
X3. TEST FOR STRAY THERMALLY GENERATED EMFS IN COPPER CONNECTING WIRES
X3.1
X4. TEST FOR THERMOCOUPLE INHOMOGENEITY
X4.1
15 REFERENCES
ASTM-E220 2007