E2847-11 Standard Practice for  Calibration and Accuracy Verification of Wideband Infrared Thermometers

Published By Publication Date Number of Pages
ASTM 2011 16
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E2847-11

Historical Standard: Standard Practice for  Calibration and Accuracy Verification of Wideband Infrared Thermometers

ASTM E2847

Scope

1.1 This guide covers electronic instruments intended for measurement of temperature by detecting the intensity of thermal radiation exchanged between the subject of measurement and the sensor.

1.2 The devices covered by this guide are referred to as infrared thermometers in this document.

1.3 The infrared thermometers covered in this guide are instruments that are intended to measure temperatures below 1000°C, measure thermal radiation over a wide bandwidth in the infrared region, and are direct-reading in temperature.

1.4 This guide covers best practice in calibrating infrared thermometers. It addresses concerns that will help the user perform more accurate calibrations. It also provides a structure for calculation of uncertainties and reporting of calibration results to include uncertainty.

1.5 Details on the design and construction of infrared thermometers are not covered in this guide.

1.6 This guide does not cover infrared thermometry above 1000°C. It does not address the use of narrowband infrared thermometers or infrared thermometers that do not indicate temperature directly.

1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Keywords

accuracy verification; background radiation; blackbody; calibration; cavity radiation source; distance to size ratio; emissivity; field-of-view; flat-plate radiation source; handheld thermometer; infrared; infrared thermometer; radiation thermometer; reflected radiation; size-of-source effect; spot size; temperature measurement; thermal imager; thermal radiation source; thermometry; transfer standard; uncertainty

ICS Code

ICS Number Code 17.200.20 (Temperature-measuring instruments)

DOI: 10.1520/E2847-11

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Practice
Significance and Use
Sources of Uncertainty
Apparatus
TABLE 1
3 FIG. 1
4 FIG. 2
5 Preparation of Apparatus
Procedure
FIG. 3
6 FIG. 4
7 Uncertainty Budget
FIG. 5
8 FIG. 6
9 Report
Recordkeeping Requirements
Keywords
10 X1. SAMPLE UNCERTAINTY BUDGET
X1.1
X2. UNCERTAINTY CALCULATION
X2.1 General
X2.2 Sakuma-Hattori Equation (Planckian Form)
TABLE X1.1
TABLE X2.1
11 X2.3 Infrared Thermometer with a Fixed Emissivity Setting
X2.4 Emissivity Uncertainty
FIG. X2.1
12 X2.5 Reflected Temperature Uncertainty
X2.6 Atmospheric Absorption Uncertainty
FIG. X2.2
13 X3. DETECTOR TEMPERATURE DETERMINATION (
X3.1
X3.2
X3.3
X3.4
X3.5
X3.6
TABLE X2.2
14 X4. SAMPLE REPORT FOR AN INFRARED THERMOMETER
FIG. X4.1
15 REFERENCES
FIG. X4.1
ASTM-E2847 2011
$44.96