Shopping Cart

No products in the cart.

ASTM-E806 2008

$40.63

E806-08 Standard Test Method for Carbon Tetrachloride and Chloroform in Liquid Chlorine by Direct Injection (Gas Chromatographic Procedure)

Published By Publication Date Number of Pages
ASTM 2008 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM E806-08

Historical Standard: Standard Test Method for Carbon Tetrachloride and Chloroform in Liquid Chlorine by Direct Injection (Gas Chromatographic Procedure)

ASTM E806

Scope

1.1 This test method is designed for the determination of carbon tetrachloride (CCl4) and chloroform (CHCl3) in liquid chlorine. The lower limit of detection is dependent on the sample size and the instrument used; five ppm (w/w) is achievable.

1.2 Review the current material safety data sheet (MSDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7 and in 9.2.3.

Keywords

analysis; carbon tetrachloride; chlorine; chloroform; gas chromatography; liquid injection; Carbon tetrachloride content; Chlorine/chlorine-based compounds; Chloroform; Gas chromatography (GC)–chemicals; Liquid chlorine

ICS Code

ICS Number Code 71.060.10 (Chemical elements)

DOI: 10.1520/E0806-08

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Summary of Test Method
Significance and Use
Apparatus
2 Reagents and Materials
Hazards
FIG. 1
3 Sampling
Preparation of Standards for Calibration
4 Chromatographic Conditions
Preparation of Calibration Curve
TABLE 1
5 Procedure
Report
Precision and Bias
Keywords
X1. PREPARATION OF PORASIL/NaCl COLUMN PACKING
X1.1 Preparation of Inert Phase
X1.2 Loading the Inert Material
X1.3 Preparing the Column
6 X2. PROCEDURE FOR CLEANING CYLINDERS AND VALVES
X2.1 Summary
X2.2 New Cylinders and Valves
X2.3 Cylinders Previously in Chlorine Service
X2.4 Cylinders Previously in Other Services