Shopping Cart

No products in the cart.

AWC SpanTables 2012

$49.40

Span Tables for Joists and Rafters

Published By Publication Date Number of Pages
AWC 2012 52
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
1 Cover
3 Title Page
5 TABLE OF CONTENTS
7 EXPLANATION OF TABLES
1. SCOPE
2. LUMBER DESIGN VALUES
3. LUMBER SIZES
4. MOISTURE CONTENT
5. SPAN MEASUREMENT
6. ROOF LOADS
8 7. LUMBER IDENTIFICATION
8. GENERAL REQUIREMENTS
9. REQUIRED COMPRESSION PERPENDICULAR TO GRAIN
9 Table 9.1 Required compression perpendicular to grain design values (Fcperp) in pounds per square inch for simple span joists and rafters with uniform load.
Table 9.2 Adjustment factors for alternate loading and spacing conditions for determining required compression perpendicular to grain design values (Fcperp) for joists and rafters.
10 SPAN TABLES
TABLE F-1 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 30psf, DL = 10psf
11 TABLE F-2 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 40psf, DL = 10psf
12 TABLE F-3 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 50psf, DL = 10psf
13 TABLE F-4 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 60psf, DL = 10psf
14 TABLE F-5 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 40psf, DL = 20psf
15 TABLE F-6 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 50psf, DL = 20psf
16 TABLE F-7 FLOOR JOISTS WITH L/360 DEFLECTION LIMITS – LL = 60psf, DL = 20psf
17 TABLE C-1 CEILING JOISTS WITH L/240 DEFLECTION LIMITS – LL = 10psf, DL = 5psf
18 TABLE C-2 CEILING JOISTS WITH L/240 DEFLECTION LIMITS – LL = 20psf, DL = 10psf
19 TABLE R-1 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 20psf, DL = 10psf
20 TABLE R-2 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 30psf, DL = 10psf
21 TABLE R-3 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 40psf, DL = 10psf
22 TABLE R-4 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 50psf, DL = 10psf
23 TABLE R-5 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 20psf, DL = 15psf
24 TABLE R-6 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 30psf, DL = 15psf
25 TABLE R-7 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 40psf, DL = 15psf
26 TABLE R-8 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 50psf, DL = 15psf
27 TABLE R-9 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 20psf, DL = 20psf
28 TABLE R-10 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 30psf, DL = 20psf
29 TABLE R-11 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 40psf, DL = 20psf
30 TABLE R-12 RAFTERS WITH L/240 DEFLECTION LIMITS – LL = 50psf, DL = 20psf
31 TABLE R-13 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 20psf, DL = 10psf
32 TABLE R-14 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 30psf, DL = 10psf
33 TABLE R-15 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 40psf, DL = 10psf
34 TABLE R-16 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 50psf, DL = 10psf
35 TABLE R-17 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 20psf, DL = 15psf
36 TABLE R-18 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 30psf, DL = 15psf
37 TABLE R-19 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 40psf, DL = 15psf
38 TABLE R-20 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 50psf, DL = 15psf
39 TABLE R-21 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 20psf, DL = 20psf
40 TABLE R-22 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 30psf, DL = 20psf
41 TABLE R-23 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 40psf, DL = 20psf
42 TABLE R-24 RAFTERS WITH L/180 DEFLECTION LIMITATION – LL = 50psf, DL = 20psf
43 APPENDIX A – COMMENTARY
A.1 Floor Joists
A.2 Ceiling Joists
44 A.3 Rafters
A.4 Compression Perpendicular to Grain Design Requirements
45 A.5 Lumber Design Values
A.6 Load Requirements
A.7 Support Requirements
A.8 Repetitive Member Use
A.9 Load Duration
A.10 Use of the Span Tables
46 Table A-1. FLOOR JOISTS WITH L/360 DEFLECTION LIMITATIONS
Table A-2. CEILING JOISTS WITH L/240 DEFLECTION LIMITATIONS
47 Table A-3. RAFTERS WITH L/240 DEFLECTION LIMITATIONS (Drywall ceiling attached to underside of rafter)
Table A-4. RAFTERS WITH L/180 DEFLECTION LIMITATIONS (No drywall ceiling attached to underside of rafter)
48 Figure A.10-1 Two-span floor joists overlap at interior span to double load carrying capacity of the floor system for the corridor.
49 Conversion Diagram for Rafters
52 Back Cover
AWC SpanTables 2012
$49.40